• Title/Summary/Keyword: 기능밸브

Search Result 136, Processing Time 0.025 seconds

Design Study of Automatic Cut-off Horizontal Valve for a LPG Cylinder (LP가스용 차단기능형 수평식 용기밸브에 대한 설계연구)

  • Kim, Chung Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.6
    • /
    • pp.80-84
    • /
    • 2015
  • In this paper, the valves for a LPG gas cylinder have been investigated on the body height and weight by comparing design data between typical automatic shut-off vertical and newly developed horizontal valves. The height of an automatic shut-off horizontal valve is radically reduced by 41~42% compared with that of a typical automatic shut-off vertical valve. And, the body weight of a horizontal valve is also reduced by 29~40% compared with that of a vertical shut-off valve. This result is just achieved by a structural design modification from typical vertical valve to horizontal arrangement of various valve components.

KSTAR 연료주입계 Piezoelectric Valve 및 제어기 개발

  • Song, Jae-In;Kim, Yeong-Ok;Kim, Gwang-Pyo;Chu, Yong;Park, Gap-Rae
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.205-205
    • /
    • 2012
  • Korea Superconducting Tokamak Advanced Research (KSTAR) 장치는 국내 유일의 초전도 자석을 이용한 핵융합 연구 장치로서 초고온의 플라즈마를 생성하여 차세대 에너지원인 핵융합 에너지를 획득하는 것을 목표로 두고 있다. 플라즈마를 생성부터 유지하기 위해서는 수소 동위원소를 토카막 내부로 공급해 주어야 하는데 이러한 수소동위원소를 "연료"라 부르며, 이 연료를 토카막 내부로 공급해 주는 시스템을 연료주입 시스템(Fueling System)이라고 한다. KSTAR에서는 토카막 내부로 고속의 연료 주입이 필요하고 정밀한 양의 연료를 공급하는 밸브를 사용하여야 하며, 이러한 밸브를 제어 할 수 있는 제어기를 필요로 한다. 위의 사항에 적합한 피에조 밸브(Piezoelectric Valve)는 2 msec 이내의 개폐시간과 500 Torr ${\ell}$/s 이상의 유량을 흘려줄 수 있는 피에조 밸브로 압전소자에 가해지는 전압(0~250 V)에 따라 변위의 양에 비례하여 연료가 진공용기 내로 유입된다. 압전소자의 변위는 최대 140 ${\mu}m$로 최적화되어 있어야 하며, 정전용량(Capacitance)는 30~40 nF이어야 한다. 또한 소자에 힘(Force)를 가해 최대 7 N으로 136 ${\mu}m$의 변위를 가진 소자를 사용해야 한다. 피에조 밸브의 특성으로는 아날로그 신호로 작동이 되어야 하며, 유량신호를 피드백하여 밸브의 구동 전압을 정밀하게 제어 되어야 한다. 피드백 제어를 위해 압력센서는 XCS-190 Series를 사용하여 낮은 유량에서도 민감하게 반응하도록 제작하였으며, 고전압이 유기 되었을 때 제어기를 보호하기 위한 정션박스를 설치하였다. 밸브 제어기는 피에조 밸브의 개방 속도를 높이기 위해 밸브 구동 전압을 순간적으로 높이는 POP 전압을 생성하는 기능과 유량 신호를 피드백해서 밸브 구동 전압을 정밀 제어 하는 기능을 가지고 있다. 제어장치는 아날로그 및 디지털 제어회로의 전원용 +15 V DC와 밸브 구동용 +250 V DC 출력용의 전원 공급 장치(Power supply unit), 펄스 및 트리거 신호를 생성하는 Master Programmer unit), Pop 전압과 피드백의 중요한 기능을 수행하는 Valve controller unit로 제작 되었다. 피에조 밸브와 제어기는 상호 작용하여 동작을 원활히 할 수 있도록 특성 실험을 진행하여야 하며, 진공상태에서 Lack의 유무를 확인하여야 한다. 현재 개발 제작된 밸브의 진공누설시험 및 특성실험을 진행하고 있으며, KSTAR 5차 캠페인에 적용할 계획이다.

  • PDF

Development of Hydrazine Thruster Latching Valve (하이드라진 추력기 래칭 밸브 개발)

  • Yoon Ho-Sung;Chae Heon-Jung;Lee Jae-Hun;Cho Nam-Kyung
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.363-367
    • /
    • 2005
  • Latching valves are operated like solenoid valves by open/close command and they maintain final open or close commend without electric power source, so they are widely used in propulsion system of satellite and launch vehicle requiring reliability and being subject of restriction of power. This paper present design and test procedure of latching valve using permanent magnet polarized solenoid, which is developed for 45N Hydrazine propulsion system, to estimate feasibility of design and manufacture of latching valve.

  • PDF

Finite Element Analysis on the Deformation Behavior Safety of a Gas Valve (가스밸브의 변형거동 안전성에 관한 유한요소해석)

  • Kim, Chung Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.4
    • /
    • pp.70-75
    • /
    • 2017
  • This paper presents the FEM analysis results on the deformation behavior safety of automatic cut-off horizontal and conventional vertical gas valves. Based on the FEM analysis, the primary maximum deformation of $4.4{\mu}m$ was formed on the right end side of a valve body when the internal gas pressure was supplied on the screw port and gas discharge port of an automatic cut-off horizontal gas valve. And the secondary maximum deformation of $2.9{\mu}m$ was formed on the end side of safety valve port. This small deformation of an automatic cut-off horizontal gas valve is strongly related to the balanced design of a horizontal gas valve main body, which is composed of a screw part, gas outlet port, port for a stem and spindle shaft assembly, and safety valve port. But, the primary maximum deformation of 0.076mm was formed on the upper part of a conventional automatic cut-off vertical gas valve when the internal gas pressure was supplied on the screw port and gas discharge port. And the secondary maximum deformation of 0.055mm was formed on the left end side of a gas outlet port. This may effect on the sealing clearance of o-ring that is inserted on the groove of an automatic cut-off unit. Thus, this paper recommends an automatic cut-off horizontal gas valve compared with that of a conventional gas valve for a gas leakage free mechanism of a LPG cylinder valve.

차단기능형 LPG용기용 밸브 문제점 및 건의사항

  • Korea LPGas Industry Association
    • LP가스
    • /
    • s.103
    • /
    • pp.8-10
    • /
    • 2006
  • 2006. 2. 6일자로 차단기능형 LPG용기용밸브 사용을 의무화하는 고법시행규칙이 개정 공포되었다. 이에 대한 문제점 및 건의사항을 우리협회와 관련업계 공동으로 제출했다.

  • PDF

Development of Rechargeable High-pressure Gas Valve (Capability of Valve to Drainage) (고압가스 충전용 밸브 개발(드레인밸브 기능포함))

  • Kwon, Kyung-Ok
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.3
    • /
    • pp.64-67
    • /
    • 2008
  • The valve applied air pressure type of high pressure packing is developed to prolong the lifetime and to enhance the airtight. The effective valve developed enables to get remove the remaining pressure through the part of valve in handle so that a separate valve to drain is no need. The character of valve developed in this experiment is high packing of valve through special form and having drain hole in stem that enables a drainage regardless the status of vale is closed or opened.

  • PDF

Auto Tuning of Position Controller for Proportional Flow Control Solenoid Valve (비례유량제어밸브 위치제어기 자동조정)

  • Jung, Gyu-Hong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.7
    • /
    • pp.797-803
    • /
    • 2012
  • Proportional solenoid valves are a modulating type that can control the displacement of valves continuously by means of electromagnetic forces proportional to the solenoid coil current. Because the solenoid-type modulating valves have the advantages of fast response and compact design over air-operated or motor-operated valves, they have been gaining acceptance in chemical and power plants to control the flow of fluids such as water, steam, and gas. This paper deals with the auto tuning of the position controller that can provide the proportional and integral gain automatically based on the dynamic system identification. The process characteristics of the solenoid valve are estimated with critical gain and critical period at a stability limit based on implemented relay feedback, and the controller parameters are determined by the classical Ziegler-Nichols design method. The auto-tuning algorithm was verified with experiments, and the effects of the operating point at which the relay control is activated as well as the relay amplitude were investigated.

Study of Valve Train Motion According to Valve Clearance (밸브 간극에 따른 밸브트레인 거동 연구)

  • Min, Sunki
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.10
    • /
    • pp.193-199
    • /
    • 2017
  • Mechanical tappet is used to reduce the cost and friction loss compared with hydraulic tappet. But the mechanical tappet doesn't have the ability to control the clearance between cams and valves and is selected by measuring the distance between valves and cams in order to minimize the clearance of valves by considering thermal expansion of valves. So, the valve clearance is nearly zero after fully warming-up periods, but there is valve clearance before warming-up. Especially at cold condition, the clearance is relatively large and can bring about some problems. In this study, the valve motions like lift, velocity, seating velocity and bouncing height were studied at various valve clearance conditions by experiment and analysis. As the valve clearance increases, the ramp area becomes shorten and it causes the valve train motion to have bad effects.

Measurement method for control valve noise (콘트롤 밸브의 소음 측정 방법)

  • Lee Y. B.;Yoon B. R.;Park K. A.;Lee D. H.;Yoo S. H.
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.515-518
    • /
    • 2002
  • 콘트롤밸브는 지역 냉${\cdot}$난방 및 APT, 대형 빌딩의 냉온수, 중온수 및 공조배관 시스템에 사용되어 유체적 바란스를 이루는데 사용된다. 이와같이 유체의 흐름을 조절하기 위하여 사용되는 콘트롤 밸브가 때로는 소음 문제를 일으키기도 한다. 최근 들어 밸브의 소음이 문제가 되는 경우가 빈번해 지고 있다. 밸브의 기본적 기능을 충족시키기 위해서는 영구적인 수두 손실이 필요하며 이러한 수두손실을 발생시키는 과정에서 유체 흐름에 의해 발생한 난류가 커다란 밸브 소음을 유발하게 된다. 본 연구에서는 콘트롤 밸브 소음 특성 평가 방법을 검토하였다. 밸브 및 배관으로 이루어진 시스템에서 발생되는 소음을 예측하는 절차를 살펴보았다. 밸브의 음향 파워레벨을 측정하고 유량 및 차압의 변화에 따른 소음 예측식을 결정 하였다. 본 연구에서 제시한 밸브 소음 측정 방법은 새로운 밸브의 소음특성 평가, 밸브 소음의 예측 그리고 서로 다른 밸브 사이의 성능비교 등에 사용될 수 있을 것이다.

  • PDF

Development of Turbine By-pass Valves Control for the Hadong Power Plant Simulator (하동화력발전소 시뮬레이터 터빈바이페스밸브제어 개발)

  • 마삼선
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 1999.10a
    • /
    • pp.46-46
    • /
    • 1999
  • 터빈 바이패스 밸브는 발전소의 사고시 발전기가 계통으로부터 분리될 때 터빈을 보호하기 위해 고온고압 에너지를 가진 증기를 안전하게 바이패스하여 발전소 신뢰도를 향상시키는 주요설비로써 신속하고 안전하게 제어가 되어야 한다. 이를 위해 증기온도 제어에 관측기를 가진 상태변수 제어기 등 고급제어가 사용되며 하동화력 시뮬레이터에 사용되는 터빈 바이패스 밸브제어의 개발과정을 서술한다. 디지털제어의 개발은 우선 제어모듈을 분석한 후 각 기능별 제어모듈을 개발하여 충분히 시험한 수 이것을 이용하여 제어로직을 모델링한다. 제어 모델링이 완료되면 발전소 다아나믹 모델과 연계를 위해 각 변수의 이출력(I/O)을 설정한다. I/O에 의해 제어로직과 발전소의 다이나믹 모델을 접속한 후 최종 튠닝(Turning)을 통하여 개발을 마무리하게 된다. 터빈 바이패스 밸브 바이패스 제어의 개발 의의를 살펴보면 각종 제어기능에 따른 모듈의 개발과 이의 적용을 통해서 실제 제어로직의 설계가 가능하며 또한 동적모델과 연계한 시뮬레이션을 통해 정확도를 높일 뿐만 아니라 확장된 제어의 개발도 가능하게 된다.

  • PDF