• Title/Summary/Keyword: 기기

Search Result 18,130, Processing Time 0.053 seconds

Assessment of Attenuation Correction Techniques with a $^{137}Cs$ Point Source ($^{137}Cs$ 점선원을 이용한 감쇠 보정기법들의 평가)

  • Bong, Jung-Kyun;Kim, Hee-Joung;Son, Hye-Kyoung;Park, Yun-Young;Park, Hae-Joung;Yun, Mi-Jin;Lee, Jong-Doo;Jung, Hae-Jo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.1
    • /
    • pp.57-68
    • /
    • 2005
  • Purpose: The objective of this study was to assess attenuation correction algorithms with the $^{137}Cs$ point source for the brain positron omission tomography (PET) imaging process. Materials & Methods: Four different types of phantoms were used in this study for testing various types of the attenuation correction techniques. Transmission data of a $^{137}Cs$ point source were acquired after infusing the emission source into phantoms and then the emission data were subsequently acquired in 3D acquisition mode. Scatter corrections were performed with a background tail-fitting algorithm. Emission data were then reconstructed using iterative reconstruction method with a measured (MAC), elliptical (ELAC), segmented (SAC) and remapping (RAC) attenuation correction, respectively. Reconstructed images were then both qualitatively and quantitatively assessed. In addition, reconstructed images of a normal subject were assessed by nuclear medicine physicians. Subtracted images were also compared. Results: ELEC, SAC, and RAC provided a uniform phantom image with less noise for a cylindrical phantom. In contrast, a decrease in intensity at the central portion of the attenuation map was noticed at the result of the MAC. Reconstructed images of Jaszack and Hoffan phantoms presented better quality with RAC and SAC. The attenuation of a skull on images of the normal subject was clearly noticed and the attenuation correction without considering the attenuation of the skull resulted in artificial defects on images of the brain. Conclusion: the complicated and improved attenuation correction methods were needed to obtain the better accuracy of the quantitative brain PET images.

Analysis of Heavy Metals in $[^{201}Tl]$TICI Injection Using Polarography (폴라로그래피를 이용한 $[^{201}Tl]$염화탈륨 주사액의 중금속 분석)

  • Chun, Kwon-Soo;Suh, Yong-Sup;Yang, Seung-Dae;Ahn, Soon-Hyuk;Kim, Sang-Wook;Choi, Kang-Hyuk;Lee, Dong-Hoon;Lim, Sang-Moo;Yu, Kook-Hyun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.4
    • /
    • pp.336-343
    • /
    • 2000
  • Purpose: Thallous-201 chloride produced at Korea Cancer Center Hospital(KCCH) is used in detecting cardiovascular disease and cancer. Thallium impurity can cause emesis, catharsis and nausea, so the presence of thallium and other metal impurities should be determined. According to USP and KP, their amounts must be less than 2 ppm in thallium and 5 ppm in total. In this study, the detection method of trace amounts of metal impurities in $[^{201}Tl]$TICI injection with polarography was optimized without environmental contamination. Materials and Methods: For the detection of metal impurities, Osteryoung Square Wave Stripping Voltammetry method was used in Bio-Analytical System (BAS) 50W polarograph. The voltammetry was composed of Dropping Mercury Electrode (DME) as a working electrode, Ag/AgCl as a reference electrode and Pt wire as a counter electrode. Square wave stripping method, which makes use of formation and deformation of amalgam, was adopted to determine the metal impurities, and pH 7 phosphate buffer was used as supporting electrolyte. Results: Tl, Cu and Pb in thallous-201 chloride solution were detected by scanning from 300 mV to -800 mV Calibration curves were made by using $TINO_3,\;CuSO_4\;and\;Pb(NO_3){_2}$ as standard solutions. Tl was confirmed at -450 mV peak potential and Cu at -50 mV Less than 2 ppm of Tl and Cu was detected and Pb was not detected in KCCH-produced thallous-201 chloride injection. Conclusion: Detection limit of thallium and copper is approximately 50 ppb with this method. As a result of this experiment, thallium and other metal impurities in thallous-201 chloride injection, produced at Korea Cancer Center Hospital, are in the regulation of USP and KP Polarograph could be applied for the determination of metal impurities in the quality control of radiopharmaceuticals conveniently without environmental contamination.

  • PDF

Survey of Current Status of Quality Control of Gamma Cameras in Republic of Korea (감마카메라 정도관리 실태 조사)

  • Choe, Jae-Gol;Joh, Cheol-Woo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.4
    • /
    • pp.314-322
    • /
    • 2008
  • Purpose: It is widely recognized that good quality control (QC) program is essential for adequate imaging diagnosis using gamma camera. The purpose of this study is to survey the current status of QC of gamma cameras in Republic of Korea for implementing appropriate nationwide quality control guidelines and programs. Methods: A collection of data is done for personnel, equipment and appropriateness of each nuclear medicine imaging laboratory's quality control practice. This survey is done by collection of formatted questionnaire by mails, emails or interviews. We also reviewed the current recommendations concerning quality assurance by international societies. Results: This survey revealed that practice of quality control is irregular and not satisfactory. The irregularity of the QC practice seems due partly to the lack of trained personnel, equipment, budget, time and hand-on guidelines. Conclusion: The implementation of QC program may cause additional burden to the hospitals, patients and nuclear medicine laboratories. However, the benefit of a good QC program is obvious that the hospitals can provide good quality nuclear medicine imaging studies to the patients. It is important to use least cumbersome QC protocol, to educate the nuclear medicine and hospital administrative personnel concerning QC, and to establish national QC guidelines to help each individual nuclear medicine laboratory.

Characteristics of the Differences between Significant Wave Height at Ieodo Ocean Research Station and Satellite Altimeter-measured Data over a Decade (2004~2016) (이어도 해양과학기지 관측 파고와 인공위성 관측 유의파고 차이의 특성 연구 (2004~2016))

  • WOO, HYE-JIN;PARK, KYUNG-AE;BYUN, DO-SEONG;LEE, JOOYOUNG;LEE, EUNIL
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.23 no.1
    • /
    • pp.1-19
    • /
    • 2018
  • In order to compare significant wave height (SWH) data from multi-satellites (GFO, Jason-1, Envisat, Jason-2, Cryosat-2, SARAL) and SWH measurements from Ieodo Ocean Research Station (IORS), we constructed a 12 year matchup database between satellite and IORS measurements from December 2004 to May 2016. The satellite SWH showed a root mean square error (RMSE) of about 0.34 m and a positive bias of 0.17 m with respect to the IORS wave height. The satellite data and IORS wave height data did not show any specific seasonal variations or interannual variability, which confirmed the consistency of satellite data. The effect of the wind field on the difference of the SWH data between satellite and IORS was investigated. As a result, a similar result was observed in which a positive biases of about 0.17 m occurred on all satellites. In order to understand the effects of topography and the influence of the construction structures of IORS on the SWH differences, we investigated the directional dependency of differences of wave height, however, no statistically significant characteristics of the differences were revealed. As a result of analyzing the characteristics of the error as a function of the distance between the satellite and the IORS, the biases are almost constant about 0.14 m regardless of the distance. By contrast, the amplitude of the SWH differences, the maximum value minus the minimum value at a given distance range, was found to increase linearly as the distance was increased. On the other hand, as a result of the accuracy evaluation of the satellite SWH from the Donghae marine meteorological buoy of Korea Meteorological Administration, the satellite SWH presented a relatively small RMSE of about 0.27 m and no specific characteristics of bias such as the validation results at IORS. In this paper, we propose a conversion formula to correct the significant wave data of IORS with the satellite SWH data. In addition, this study emphasizes that the reliability of data should be prioritized to be extensively utilized and presents specific methods and strategies in order to upgrade the IORS as an international world-wide marine observation site.

Analysis and Design of Profiling Adaptor for XML based Energy Storage System (XML 기반의 에너지 저장용 프로파일 어댑터 분석 및 설계)

  • Woo, Yongje;Park, Jaehong;Kang, Mingoo;Kwon, Kiwon
    • Journal of Internet Computing and Services
    • /
    • v.16 no.5
    • /
    • pp.29-38
    • /
    • 2015
  • The Energy Storage System stores electricity for later use. This system can store electricity from legacy electric power systems or renewable energy systems into a battery device when demand is low. When there is high electricity demand, it uses the electricity previously stored and enables efficient energy usage and stable operation of the electric power system. It increases the energy usage efficiency, stabilizes the power supply system, and increases the utilization of renewable energy. The recent increase in the global interest for efficient energy consumption has increased the need for an energy storage system that can satisfy both the consumers' demand for stable power supply and the suppliers' demand for power demand normalization. In general, an energy storage system consists of a Power Conditioning System, a Battery Management System, a battery cell and peripheral devices. The specifications of the subsystems that form the energy storage system are manufacturer dependent. Since the core component interfaces are not standardized, there are difficulties in forming and operating the energy storage system. In this paper, the design of the profile structure for energy storage system and realization of private profiling system for energy storage system is presented. The profiling system accommodates diverse component settings that are manufacturer dependent and information needed for effective operation. The settings and operation information of various PCSs, BMSs, battery cells, and other peripheral device are analyzed to define profile specification and structure. A profile adapter software that can be applied to energy storage system is designed and implemented. The profiles for energy storage system generated by the profile authoring tool consist of a settings profile and operation profile. Setting profile consists of configuration information for energy device what composes energy saving system. To be more specific, setting profile has three parts of category as information for electric control module, sub system, and interface for communication between electric devices. Operation profile includes information in relation to the method in which controls Energy Storage system. The profiles are based on standard XML specification to accommodate future extensions. The profile system has been verified by applying it to an energy storage system and testing charge and discharge operations.

Improvement of an Simultaneous Determination for Clenbuterol and Ractopamine in Livestock Products using LC-MS/MS (LC-MS/MS를 이용한 축산물 중 clenbuterol과 ractopamine의 동시 분석법 개선)

  • Cho, Yoon-Jae;Chae, Young-Sik;Kim, Jae-Young;Kim, Hyung-Soo;Kang, Ilhyun;Do, Jung-Ah;Oh, Jae-Ho;Kwon, Kisung;Chang, Moon-Ik
    • Korean Journal of Food Science and Technology
    • /
    • v.45 no.1
    • /
    • pp.25-33
    • /
    • 2013
  • Clenbuterol and ractopamine, which are ${\beta}$-agonists, have been misused as a growth promoting agent in meat producing animals. Clenbuterol was banned for veterinary drug in Korea because of its problems regarding safety. Due to their adverse effects, such as cardiovascular and central nervous diseases on human health proper control and monitoring should be conducted. The existing analytical method of clenbuterol and ractopamine in the Food code was improved through our present study. The bovine muscle samples were subjected to enzymatic hydrolysis, extracted with ethyl acetate and defatted by hexane-methanol partitioning. A molecular imprinted polymer (MIP) solid phase extraction cartridge was used for clean-up and LC-MS/MS was operated in positive multiple reaction monitoring (MRM). Clenbuterol-$d_9$ and ractopamine-$d_3$ were used as an internal standard. The renewed method was validated according to the CODEX guideline. The limits of quantitation for clenbuterol and ractopamine were 0.2 and 0.5 ${\mu}g/kg$, respectively. The mean recoveries ranged in 104.2-113.5% for clenbuterol and in 107.6-118.1% for ractopamine. The improved method was able to save both time and expenses.

Moving Distance of Laborer in the Kitchen for Systematic of the Korean Foods (한식(韓食)의 편의식화(便宜食化)를 위한 주방동선(?房動線)에 관한 연구)

  • Park, Hyung-Woo;Koh, Ha-Young;Kang, Tong-Sam
    • Journal of the Korean Society of Food Culture
    • /
    • v.2 no.1
    • /
    • pp.1-8
    • /
    • 1987
  • In order to develop a convenient Korean food service system in commercial kitchen, processing procedure and recipe of 10 kinds of Korean food to be served as a convenient foods were decided. Moving distance and required energy of laborer in the commercial and model restaurants which have the area of $62.8m^2$ and $32.4m^2$, respectively, were measured by arranging these machinery. The results obtained were summarized as follows. In case of restaurant with the area of $62.8m^2$, moving distance, working hours and required energy of laborers were 1,922m, 2,986min and 4,704kcal in C-store, 2,134m, 3,173min and 5,001.7kcal in T-store, and 1,704m, 2,808min and 4,414.5kcal in model restaurant, respectively. Therefore energy requirements of the model restaurant were less 289.5kcal (4.5%) and 587.2kcal (10.1%) than those of C and T store. In case of restaurant with the area of $32.4m^2$, moving distance, working hours and required energy of laborer in S store were 1,277m, 2,926min and 4,588kcal, 1,425m, 3,108min and 4,873.8kcal in H restaurant and 1,167m, 2,798min and 4,381.4kcal in model restaurant, respectively. Therefore energy requirements of the model restaurant were less 206.6kcal (4.7%) and 492.4kcal (11.2%) than those of S store and H restaurant. When 6 kinds of convenient foods and 4 kinds of direct cooking foods were produced, moving distance, working hours and required energy of laborer in S store were 554.7m, 972min and 1,586.0kcal, 684.7m, 991min and 1,579.2kcal in H restaurant, 523.1m, 938min and 1,479.5kcal in model restaurant. Therefore energy requirements of the model restaurant were less 99.7kcal(6.7%) and 106.5kcal(7.2%) than those of S store and H restaurant. In case of the energy saving system kitchen, moving distance and required energy were saved less by 42% and by 20.4% than those of model kitchen, respectively.

  • PDF

The Naturally Occurring Levels of Nitrate and Nitrite in Livestock Products (축산물 중 천연유래 질산염 및 아질산염 함유량 조사)

  • Choi, Jae-Chun;Park, So-Ra;Lim, Ho-Soo;Ko, Kyung-Yuk;Kim, Meehye
    • Journal of Food Hygiene and Safety
    • /
    • v.30 no.3
    • /
    • pp.265-271
    • /
    • 2015
  • This study was done in order to investigate the naturally occurring levels of nitrate and nitrite in livestock products. Total samples of 458 consisting of meats (n = 223), processed meat products (n = 51), raw milks (n = 30), processed milk products (n = 142), eggs (n = 5) and processed egg products (n = 7) were analyzed for contents of nitrate and nitrite by ion chromatography (IC). That methods showed good results in terms of linearity, limit of detection (LOD), limit of quantitation (LOQ), recovery, reproducibility and uncertainty. Nitrate and nitrite were detected in 167 and 40 samples, respectively. The nitrate levels (mg/kg) were not detected (ND)~40.23 for modified milks, ND~37.97 for sauce meats, ND~32.40 for process cheeses, ND~31.50 for processed egg products, ND~27.73 for dry milks, ND~24.76 for sausages, ND~22.45 for bacons, ND~21.55 for natural cheeses, ND~20.82 for hams and fermented milks, ND~13.57 for eggs, ND~12.77 for butters, ND~9.31 for milks and ND~3.88 for meats while the nitrite levels (mg/kg) were ND~17.35 for processed egg products and ND~1.92 for meats. In conclusion, the result of this study of nitrate and nitrite in livestock products could be used as one of scientific base datum to determine whether they are naturally occurring or not, including ingredients and their percentage, manufacturing processes, other papers relating to naturally occurring levels of them, and so on.

Evaluation of hazardous factors for the application of HACCP on production and transportation flow in home-delivered meals for the elderly (노인을 위한 가정배달급식의 생산 및 배송단계에 HACCP 적용을 위한 위해요인 분석 1)

  • 김혜영;류시현
    • Korean journal of food and cookery science
    • /
    • v.19 no.2
    • /
    • pp.195-209
    • /
    • 2003
  • The purpose of this study was to identify the hazard analysis critical control point on food production and transportation flow, applied to home-delivered meals for the elderly. To carry out this study, 1) pan-fried oak mushroom and meat, soy sauce glazed hair tail, and roasted dodok were selected as high nutrient and preferred foods for the elderly and 2) time, temperature, and microbiological quality(standard plate count, coliform, Salmonella spp, Vibrio parahaemolyticus, Staphylococcus spp., Escherichia coli O157:H7, and Listeria monocytogenes) were measured at various phases of the home-delivered meal production and its transportation flows. The results of this experiments are as follows: The temperature measured at cooling phases during the home-delivered meal production flows was 19.2 ∼ 20.0$^{\circ}C$ for the pan- fried oak mushroom and meat and the roasted dodok and was 24.0 ∼ 25.2$^{\circ}C$ for the soy sauce glazed hair tail. These temperature were in the potentially dangerous zone. Microbiological analysis showed that S. spp. was higher in the raw ingredients, including oak mushroom, hair tail, radish, and dodok, than the standard limit. SPC was lower than the standard limit from cooking to transportation phase, but SPC increased significantly during the cooling and packaging phase. The level of coliform detected was far lower than the standard limit and was not detected at all during the transportation phase. Few S. spp. was detected in the pan-fried oak mushroom and meat, but was found in above standards limit during the wrap packaging phase in the soy sauce glazed hair tail and roasted dodok. The level decreased rapidly during the holding and transportation phase. Sal. spp., V. parahaemolyticus, S. spp., E. coli O157:H7, and L. monocytogenes were not detected. For the pan-fried oak mushroom and meat, the critical control points were during the purchasing and receiving of raw ingredients, cooling, and packaging phases. For the soy sauce glazed hair tail and roasted dodok, the critical control points were during the purchasing and receiving of raw ingredients, preparation, cooling, and packaging phases.

The evaluation of color and color difference according to the layering placement of Incisal shade composites on the body composites of the indirect resin restoration (간접 수복용 복합레진의 Incisal 색상 적층 두께에 따른 표면 색상 및 색차의 평가)

  • Park, Su-Jung;Lee, Han-Young;Nah, Myong-Yun;Chang, Hoon-Sang;Hwang, Yun-Chan;Oh, Won-Mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.1
    • /
    • pp.37-49
    • /
    • 2011
  • Objectives: The aim of this study was to evaluate the surface color of indirect resin restoration according to the layering placement of different shade of incisal composite. Materials and Methods: In this study, CIE $L^*a^*b^*$ value of 16 Body composite of Tescera ATL (Bisco, Schaumburg IL,USA) was measured by spectrophotometer (NF999, Nippon Denshuku, Japan), and compared to CIE $L^*a^*b^*$ value of Vitapan shade guide. Nine shade Incisal composite of Tescera ATL were buildup to 1 mm thickness on Body composites inlay block, and CIE $L^*a^*b^*$ value was measured. Incisal composite was ground to 0.5 mm thickness and CIE $L^*a^*b^*$ value was re-measured. Color difference between Body composite and Incisal composites layered on Body composite was calculated as a function of thickness. Results: Color difference between corresponding shade of Tescera Body composite and Vitapan shade guide was from 6.88 to 12.80. $L^*$ and $b^*$ value was decreased as layering thickness of Incisal composite on Body composite was increased. But, $a^*$ value did not show specific change tendency. Conclusions: Surface color difference between Body composites and Incisal composites layered on Body composite was increased as the layering thickness of Incisal composite increased (p < 0.05).