• Title/Summary/Keyword: 기기

Search Result 18,163, Processing Time 0.054 seconds

Actual Condition of Quality Control of X-ray Imaging System in Primary Care Institution: focused on Gwangju Metropolitan City (1차 의료기관의 엑스선 발생장치 정도관리에 관한 현황조사:광주광역시 지역을 중심으로)

  • Dong, Kyung-Rae;Lee, Seun-Joo;Kweon, Dae-Cheol;Goo, Eun-Hoe;Jung, Jae-Eun;Lee, Kyu-Su
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.1
    • /
    • pp.34-42
    • /
    • 2010
  • With the expanded use of radiation in modern medical practices, the most important issue in regards to efforts to reduce individual exposure dose is quality assurance. Therefore in order to study the present condition of quality assurance, the Gwangju Metropolitan City area was divided into five districts each containing ten hospitals. Four experiments were conducted: a reproducibility experiment for kVp, mA, and examination time (sec) intensity of illumination; half-value layer (HVL) measurement; and beam perpendicularity test matching experiment. The tube voltage reproducibility experiment for all fifty hospitals resulted in a 95.33% passing rate and mA and examination time both resulted in a 77.0% passing rate. The passing rate for intensity of illumination was 86.0% and 52.0% for HVL, which was the lowest passing rate of all four factors. For the beam perpendicularity test matching experiment, generally the central flux is matched to within $1.5^{\circ}$. Of all fifty hospitals 30.0% were beyond $3^{\circ}$. The results of the survey showed that 58% responded that they knew about quality assurance cycle. All fifty respondents stated that they have not received any training in regards to quality assurance at their current place of employment. Although quality assurance is making relative progress, the most urgent issue is awareness of the importance of quality assurance. Therefore, the implementation of professional training focusing on safety management and accurate quality assurance of radiation will reduce the exposure to radiation for radiologists and patients and higher quality imaging using less dosage will also be possible.

Evaluation of Cleanness and Physical Properties of W/O Microemulsion (W/O Microemulsion 세정제의 물성 및 세정성 평가)

  • Lee, Myung Jin;Han, Ji Won;Lee, Ho Yeol;Han, Sang Won;Bae, Jae Heum;Park, Byeong Deog
    • Korean Chemical Engineering Research
    • /
    • v.40 no.6
    • /
    • pp.769-777
    • /
    • 2002
  • Using four components - nonionic surfactants, water, hydrocarbon oil and an alcohol as cosurfactant, 12 types of cleaning agents were prepared, and their physical properties such as surface tension, viscosity, electroconductivity and phase stability were measured. As the formulated cleaning agents have low surface tensions(30.5-31.1 dyne/cm) and low viscosities (1.6-7.2 c.p.), they are satisfied with the general physical properties of water-in-oil(W/O) microemulsions for their industrial use. They showed a tendency that their temperature range for stable one-phase microemulsion decreased in accordance with the increase of alcohol/surfactant(A/S) ratio in the formulations. However, the temperature range of one-phase microemulsion was much more affected by hydrophilic lipophillic balance(HLB) value of the nonionic surfactant which increased its temperature range and it increased in accordance with the higher HLB value in the formulations. And the maximum content of water which can keep stable one-phase W/O microemulsion was measured at each sample. In addition, their temperature range for stable one-phase microemulsion was also measured. It was confirmed that the selection of surfactant type was very important for formulating a cleaning agent, since the W/O microemulsion system with the nonionic surfactant of the lower HLB value showed better cleaning efficacy that of the higher HLB value for abietic acid as a soil, which was used for preparing a rosin-type flux. In the formulated cleaning agents with the increase of A/S ratio in the formulations, however, there was no significant difference in cleaning efficacy. It was investigated that the differences of their cleaning efficacy was affected by the change of the condition of temperature and sonicating frequency as important factors in the industrial cleaning. That is, the higher, their cleaning temperature and the lower, their sonicating frequency, the more increased, their cleaning efficacy. Furthermore, using optical instruments like UV/Visable Spectrophotometer and FT-IR Spectrometer, their cleaning efficacy for abietic acid was measured. The removal of soil from the contaminated rinse water was measured by gravity separation method in the rinse bath. As a result, the cleaning agent system having the nonionic surfactant of HLB value 6.4 showed over 85% water-oil separation efficacy at over $25^{\circ}C$. Therefore, it was demonstrated in this work that the formulating cleaning agents were very effective for cleaning and economical in the possible introduction of water recycling system.

Negative apparent resistivity in dipole-dipole electrical surveys (쌍극자-쌍극자 전기비저항 탐사에서 나타나는 음의 겉보기 비저항)

  • Jung, Hyun-Key;Min, Dong-Joo;Lee, Hyo-Sun;Oh, Seok-Hoon;Chung, Ho-Joon
    • Geophysics and Geophysical Exploration
    • /
    • v.12 no.1
    • /
    • pp.33-40
    • /
    • 2009
  • In field surveys using the dipole-dipole electrical resistivity method, we often encounter negative apparent resistivity. The term 'negative apparent resistivity' refers to apparent resistivity values with the opposite sign to surrounding data in a pseudosection. Because these negative apparent resistivity values have been regarded as measurement errors, we have discarded the negative apparent resistivity data. Some people have even used negative apparent resistivity data in an inversion process, by taking absolute values of the data. Our field experiments lead us to believe that the main cause for negative apparent resistivity is neither measurement errors nor the influence of self potentials. Furthermore, we also believe that it is not caused by the effects of induced polarization. One possible cause for negative apparent resistivity is the subsurface geological structure. In this study, we provide some numerical examples showing that negative apparent resistivity can arise from geological structures. In numerical examples, we simulate field data using a 3D numerical modelling algorithm, and then extract 2D sections. Our numerical experiments demonstrate that the negative apparent resistivity can be caused by geological structures modelled by U-shaped and crescent-shaped conductive models. Negative apparent resistivity usually occurs when potentials increase with distance from the current electrodes. By plotting the voltage-electrode position curves, we could confirm that when the voltage curves intersect each other, negative apparent resistivity appears. These numerical examples suggest that when we observe negative apparent resistivity in field surveys, we should consider the possibility that the negative apparent resistivity has been caused by geological structure.

Distribution Characteristics of Environmental Contaminant at Soil in an Industrial Complex Area (공단지역 토양 중 환경오염물질 농도 분포 특성)

  • Jung, Jong-Hyeon;Cho, Sang-Won;Lim, Hyun-Sul
    • Clean Technology
    • /
    • v.18 no.2
    • /
    • pp.200-208
    • /
    • 2012
  • This study was performed to prevent the health damage of environmental contaminants in Industrial Complex Area. And, this study aimed to identify the concentration levels and distribution characteristics of environmental contaminants and Polycyclic Aromatic Hydrocarbons (PAHs) at soil in Industrial Complex Area and control area. The concentration of the soil pollution standard such as the heavy metals in the soil, VOCs, PAHs, and PCB were measured and analyzed using the soil specimens in the Industrial Complex Area and control area. Soil specimens from the Industrial Complex Area (the direct exposure area) and the control area were surveyed. Songdo-dong, Haedo-dong and Jechul-dong, which are in the direct exposure area and near the emission source, showed relatively high concentrations of contaminant materials when compared with Jangki-myeon, which is far off and in the control area. The concentration of zinc was 20.8-58.9% of the level of concern (300 mg/kg) in the 1st region, which is a relatively high concentration. The concentration of fluoride was under the standard in every region, but it was about 74% of the level of concern (400 mg/kg) in the 1st region. It is recommended that controlling fluoride emissions is necessary. Levels of organic phosphate, phenol, and VOCs like benzene, toluene, ethylbenzene and xylene were under the detection limit of the analysis instruments. The concentration of TPH was high in Songdo-dong. The concentration of contaminants in Jechul-dong was high. In addition, it was observed that the level of soil contamination changed depending on the distance from the emission source. The concentration of PAH compounds in the soil was 18.71-1744.59 ng/g, and the concentration of six potential cancer-causing PAH materials was 6.54-695.94 ng/g. The highest concentration was in Songdo-dong. The PAH concentration in the direct exposure area near the complex was relatively high compared to the indirect exposure area.

Immune Cell Activation and Co-X-irradiation Effect of Eleutherococcus senticosus Maxim Root (가시오갈피 뿌리의 면역세포 활성 및 방사선 병용효과)

  • Kwon, Hyoung-Cheol;Park, Jeong-Seob;Choi, Dong-Seong
    • Radiation Oncology Journal
    • /
    • v.25 no.3
    • /
    • pp.185-191
    • /
    • 2007
  • Purpose: This study was performed to investigate the effects of immune cell activation and the antitumor effect for the combination of treatment with X-irradiation and E/eutherococcus senticosus Maxim Root (ESMR) on mouse tumor cells. Materials and Methods: ESMR (250g) was extracted with 80% methanol, concentrated under decompression and lyophilized. To determine whether ESMR is able to activate the immune cells or not, the proliferation of splenocytes in vitro and the number of B cells and T cells in splenic lymphocytes in ESMR-pretreated mice were evaluated. X-irradiation was given to the mouse fibrosarcoma tumor cells (FSa II) by 250 kv X-irradiation machine. The cytotoxicity of ESMR was evaluated from its ability to reduce the clonogenecity of FSa II cells. In X-irradiation alone group, each 2, 4, 6 and 8 Gy was given to FSa II cells. In X-irradiation with ESMR group, 0.2 mg/ml of ESMR was exposed to FSa II cells for 1 hour before X-irradiation. Results: The proliferation of cultured mouse splenocytes and thymocytes were enhanced by the addition of ESMR in vitro. The number of B cells and T cells in mouse splenic lymphocytes was significantly increased in ESMR pretreated mice in vivo. In FSa II cells that received a combination of 0.2 mg/ml of ESMR with X-irradiation exposure, the survival fraction with a dose of 2, 4 and 6 Gy was $0.39{\pm}0.005$, $0.22{\pm}0.005$ and $0.06{\pm}0.007$, respectively. For FSa II cells treated with X-irradiation alone, the survival fraction with a dose of 2, 4 and 6 Gy was $0.76{\pm}0.02$, $0.47{\pm}0.008$ and $0.37{\pm}0.01$. The difference in the survival fraction of the mouse FSa II cells treated with and without ESMR was statistically significant (p<0.05). Conclusion: Treatment with ESMR increased cell viability of mouse splenocytes in vitro and especially the subpopulation of B cells and T cells in splenocytes in ESMR-pretreated mice. However, treatment with ESMR did not increase the level of Th and Tc subpopulations in the thymocytes. Treatment with the combination of ESMR and X-irradiation was more cytotoxic to mouse tumor cells than treatment with X-irradiation alone; this finding was statistically significant.

Comparison of Ultrasound Histogram in Liver, Kidney and Spleen in Beagle Dogs (비글견에 있어서 간, 신장 및 비장의 초음파 히스토그램 비교)

  • Lee Kichang;Jung Joohyun;Oh Sunkyoung;Jeong Yucheol;Lim Changyun;Yoon Junghee;Choi Mincheol
    • Journal of Veterinary Clinics
    • /
    • v.22 no.3
    • /
    • pp.186-189
    • /
    • 2005
  • For the assessment of the clinical application of histogram on internal parenchymal organs, ultrasonography with a multi-frequency transducer was taken. We scanned in the region of right cranial abdomen for both liver and right kidney, and left cranial abdomen for liver, spleen and left kidney in 9 normal Beagle dogs. The data from histogram examined in a region of interest centered on each picture element of B-mode images at the same depth were compared among liver, renal cortex, spleen, cortex and medulla of each kidney. The right renal cortex showed significantly lower echogenicity than parenchyma of liver by $15{\%}$. Spleen was more echogenic than the cortex of the left kidney by $23{\%}$, and liver was more echogenic than the left renal cortex by $30{\%}$. Renal cortex was more echogenic than medulla by $47{\%}$ and $65{\%}$ on the right and left side, respectively (p<0.05). The mean (${\pm}SD$) values calculated echogenicity were $46.2{\pm}12.3\;(95\%$ confidential interval (CI), 41.0 to 55.0) and $53.4{\pm}12.1\;(95\%$ CI, 47.0 to 55.1) in in the right renal cortex and liver parenchyma, $65.0{\pm}11.8\;(95\%$ CI, 57.9 to 71.0) and $51.0{\pm}16.9\;(95\%$ CI, 42.8 to 54.1) in splenic parenchyma and renal cortex. And the mean values calculated echogenicity were $65.0{\pm}10.15\;(95\%$ CI, 60.1 to 71.5) and $52.0{\pm}9.4\;(95\$ CI, 43.8 to 60.3) in liver parenchyma and the left renal cortex, $54.5{\pm}18.3\;(95\%$ CI, 40.1 to 62.8) and $35.0{\pm}16.2\;(95\%$ CI, 24.2 to 43.6) in the left renal cortex and medulla. And the mean values calculated echogenicity were $55.0{\pm}14.4\;(95\%$ CI, 47.3 to 61.7) and $40.0{\pm}13.2\;(95\%$ CI, 34.3 to 46.7) in the right renal cortex and medulla, respectively. In addition, the echogenicity ratios were $0.86{\pm}0.11$ between the right renal cortex and liver parenchyma, $1.37{\pm}0.47$ between spleenic parenchyma and the left renal cortex, $1.30{\pm}0.19$ between liver parenchyma and the left renal cortex. All the values measured showed significant different (p<0.05). Ultrasound histogram is simple, useful and feasible to evaluate the sonographic architecture of the internal organs such as liver, spleen and kidney, quantitatively.

Pelvic MRI Application to the Dosimetric Analysis in Brachytherapy of Uterine Cervix Carcinoma (자궁경부암의 강내조사치료에 있어서 흠수선량평가시 골반강 자기공명사진의 응용)

  • Chung, Woong-Ki;Nah, Byung-Sik;Ahn, Sung-Ja
    • Radiation Oncology Journal
    • /
    • v.15 no.1
    • /
    • pp.57-64
    • /
    • 1997
  • Purpose : Before we report the results of curative radiotherapy in cervix cancer patients, we review the significance and safety of our dose specification methods in the brachytherapy system to have the insight of the potential Predictive value of doses at specified points. Matersials and Methods : We analyze the 리5 cases of cervix cancer patients treated with intracavitary brachytherapy in the lateral simulation film we draw the isodose curve and observe the absorbed dose rate of point A, the reference point of bladder(SBD) and rectum(SRD). In the sagittal view of Pelvic MRI film we demarcate the tumor volume(TV) and determine whether the prescription dose curve of point A covers the tumor volume adequately by drawing the isodose curve as correctly as possible. Also we estimate the maximum Point dose of bladder(MBD) and rectum(MRD) and calculate the inclusion area where the absorbed dose rate is higher than that of point A in the bladder(HBV) and rectum(HRV), respectively. Results : Of forty-five cases, the isodose curve of point A seems to cover tumor volume optimally in only 24(53%). The optimal tumor coverage seems to be associated not with the stage of the disease but with the tumor volume. There is no statistically significant association between SBD/SRD and MBD/MRD, respectively. SRD has statistically marginally significant association with HRV, while TV has statistically significant association with HBV and HRV. Conclusion : Our current treatment calculation methods seem to have the defect in the aspects of the nonoptimal coverage of the bulky tumor and the inappropriate estimation of bladder dose. We therefore need to modify the applicator geometry to optimize the dose distribution at the position of lower tandem source. Also it appears that the position of the bladder in relation to the applicators needs to be defined individually to define 'hot spots'.

  • PDF

Analysis of 236 Pesticides in Apple for Validation of Multiresidue Method using QuEChERS Sample Preparation and PTV-GC/TOFMS Analysis (QuEChERS법과 PTV-GC/TOFMS 이용 잔류농약 분석법 개발을 위한 사과시료 중 236종 농약의 동시분석)

  • Ju, Ok-Jung;Kwon, Hye-Young;Park, Byeong-Jun;Kim, Chan-Seob;Jin, Yong-Duk;Lee, Je-Bong;Yun, Seo-Hee;Son, Kyung-Ae;Hong, Su-Myeong;Im, Geon-Jae
    • The Korean Journal of Pesticide Science
    • /
    • v.15 no.4
    • /
    • pp.401-416
    • /
    • 2011
  • The recent trend for pesticide residue analysis in food involves fast cleanup and use of mass spectrometry to achieve quantitative and qualitative analysis at the same time. Recently, the QuEChERS (quick, easy, cheap, effective, rugged and safe) multi-reside method has received much attention as a fast extraction and cleanup method of pesticide residue analysis. Therefore, multi-residue analysis of 236 pesticides was tested with the QuEChERS method by concurrent use of PTV-GC/TOFMS (gas chromatography/ time-of-flight mass spectrometry with programmable temperature vaporizer). PTV condition was optimized and when the method was applied to apples, pesticide recovery rates (spiked at 400 ng/g) ranged from 80% to 120%, and RSD values were under 10% for most compounds. The results showed that the QuEChERS sample preparation and PTV-GC/TOFMS analysis can be applied to multi-residue analysis of pesticides in fruits and vegetables.

A Study on the Sanitary Status at Various Types of Restaurants in Changwon City (창원시 식품접객업소의 위생실태에 관한 조사연구)

  • 이경혜;류은순;이경연
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.30 no.4
    • /
    • pp.747-759
    • /
    • 2001
  • The sanitary status of 264 restaurants was investigated to develop a program of sanitary education at restaurants for improving sanitary levels of restaurant and consumers’ food safety. This investigation was performed through direct interviews on general items and sanitations for employees, facilities, equipments and food treatment. The restaurants are grouped into four different types according to the food served: Korean style food, Japanese style raw fish, roasted ribs, and western style food. It is found that sanitary education for employees are conducted at 66.5% of the total restaurants. The highest percentages are obtained by Korean style food restaurants (83.1%) and the lowest by western style food restaurants (55.6%).Washing facilities for employees are equipped at only 66.8% of the total restaurants. In the personal sanitation, 96.6% of the employees wash their hand after touching a dirty stuff, 77.5% after touching money and 57.1% after using telephone. It is also revealed that during food preparation shoes, overgarments, and caps are worn by 58.5%, 55.5%, and 20.6% of the employees, respectively. 73.5% of the restaurants are equipped with dish storages facilities while only 59.2% of restaurants have sterilizers for dishes. Also, chopping boards are sterilized more than once a week by 74.8% of them and knives everyday by 71.6%, 15.4% of restaurants sterilize their knives only once a week. 56.8% of restaurants check temperatures of the refrigerators and 26.2% of restaurants do not even sterilize the refrigerators. 31.8% of restaurants sterilize the kitchens with sodium hopochlorite after cooking. 93.3% of the restaurants store the raw food and the cooked foods separately. 49.8% of the restaurants refroze thawed food and 19.4% of the restaurants reuse leftovers. The frozen foods are thawed at room temperature by 49.4% of the total restaurants and 66.7% of the roasted rib restaurants.

  • PDF

The Inhibitory Effects of Pogostemon cablin Bentham Extract on Melanogenesis (광곽향 추출물의 멜라닌 생성 저해 효과)

  • Bae, Seong-Yun;Lee, Eung-Ji;Son, Rak-Ho;Lee, Yong-Hwa
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.35 no.1
    • /
    • pp.33-39
    • /
    • 2009
  • To develop a new natural whitening agent for cosmetics, we investigated the inhibitory effects of Pogostemon cablin Bentham extracts (PCE) and its active component on melanogenesis. PCE showed ROS scavenging activities in 1,1-diphenyl-2-picrylhydrazyl (DPPH) radical and xanthine/xanthine oxidase system with the $IC_{50}$ values of $24.2{\pm}2.85{\mu}g/mL$ and $IC_{50}=118{\pm}0.43{\mu}g/mL$, respectively. PCE reduced melanin contents of B16 melanoma cells in a dose-dependant manner and decreased to about 23 % at a concentration of $20{\mu}g/mL$ without cell cytotoxicity (below $100{\mu}g/mL$). And the PCE reduced intracellular tyrosinase activity about 18 % at concentration of $50{\mu}g/mL$. We purified one active compound from PCE and identified its structure. It was identified as patchouli alcohol, sesquiterpene family, by 1H-NMR, $13_C$-NMR, and Mass analysis. Patchouli alcohol also inhibited ROS scavenging activities in DPPH radical and xanthine/xanthine oxidase system with the $IC_{50}$ values of $3.14{\pm}0.12{\mu}g/mL$ and $49{\pm}3.24{\mu}g/mL$, respectively. Patchouli alcohol inhibited melanin synthesis in a dose dependent manner ($IC_{50}=3.9{\mu}g/mL$). And the patchouli alcohol reduced intracellular tyrosinase activity about 40 % at concentration of $10{\mu}g/mL$. Patchouli alcohol inhibited tyrosinase and TRP-2 expression at protein level. These results suggest that PCE and patchouli alcohol reduced melanin formation by the inhibited of tyrosinase activity and expression in B16 melanoma cells. Therefore, we suggest that PCE could be used as a useful whitening agent.