• Title/Summary/Keyword: 기기

Search Result 18,163, Processing Time 0.046 seconds

Measurements of Setup Error and Physiological Movement of Liver by Using Electronic Portal Imaging Device in Patients with Hepatocellular Carcinoma (간암환자에서 Electronic Portal Imaging Device(EPID)를 이용한 자세 오차 및 종양 이동 거리의 객관적 측정)

  • Keum Ki Chang;Lee Sang-wook;Shin Hyun Soo;Kim Gwi Eon;Sung Jinsil Seong;Lee Chang Geol;Chu Sung Sil;Chang Sei-Kyung;Suh Chang Ok
    • Radiation Oncology Journal
    • /
    • v.18 no.2
    • /
    • pp.107-113
    • /
    • 2000
  • Purpose : The goal of this study 닌as to improve the accuracy of three-dimensional conformal radiotherapy (3-D CRT) by measuring the treatment setup error and physiological movement of liver based on the analysis of images which were obtained by electronic portal imaging device (EPID). Materials and Methods : For 10 patients with hepatocellular carcinoma, 4-7 portal images were obtained by using EPID during the radiotherapy from each patient daiiy. We analyzed the setup error and physiological movement of liver based on the verification data. We also determined the safety margin of the tumor in 3-D CRT through the analysis of physiological movement. Results : The setup errors were measured as 3mm with standard deviation 1.70 mm in x direction and 3.7 mm with standard deviation 1.88 mm in y direction respectively. Hence, deviation were smaller than 5mm from the center of each axis. The measured range of liver movement due to the physiological motion was 8.63 mm on the average. Considering the motion of liver and setup error, the safety margin of tumor was at least 15 mm. Conclusion : EPID is a very useful device for the determination of the optimal margin of the tumor, and thus enhance the accuracy and stability of the 3-D CRT in patients with hepatocellular carcinoma.

  • PDF

Current Status and Future Prospect of Plant Disease Forecasting System in Korea (우리 나라 식물병 발생예찰의 현황과 전망)

  • Kim, Choong-Hoe
    • Research in Plant Disease
    • /
    • v.8 no.2
    • /
    • pp.84-91
    • /
    • 2002
  • Disease forecasting in Korea was first studied in the Department of Fundamental Research, in the Central Agricultural Technology Institute in Suwon in 1947, where the dispersal of air-borne conidia of blast and brown spot pathogens in rice was examined. Disease forecasting system in Korea is operated based on information obtained from 200 main forecasting plots scattered around country (rice 150, economic crops 50) and 1,403 supplementary observational plots (rice 1,050, others 353) maintained by Korean government. Total number of target crops and diseases in both forecasting plots amount to 30 crops and 104 diseases. Disease development in the forecasting plots is examined by two extension agents specialized in disease forecasting, working in the national Agricul-tural Technology Service Center(ATSC) founded in each city and prefecture. The data obtained by the extension agents are transferred to a central organization, Rural Development Administration (RDA) through an internet-web system for analysis in a nation-wide forecasting program, and forwarded far the Central Forecasting Council consisted of 12 members from administration, university, research institution, meteorology station, and mass media to discuss present situation of disease development and subsequent progress. The council issues a forecasting information message, as a result of analysis, that is announced in public via mass media to 245 agencies including ATSC, who informs to local administration, the related agencies and farmers for implementation of disease control activity. However, in future successful performance of plant disease forecasting system is thought to be securing of excellent extension agents specialized in disease forecasting, elevation of their forecasting ability through continuous trainings, and furnishing of prominent forecasting equipments. Researches in plant disease forecasting in Korea have been concentrated on rice blast, where much information is available, but are substan-tially limited in other diseases. Most of the forecasting researches failed to achieve the continuity of researches on specialized topic, ignoring steady improvement towards practical use. Since disease forecasting loses its value without practicality, more efforts are needed to improve the practicality of the forecasting method in both spatial and temporal aspects. Since significance of disease forecasting is directly related to economic profit, further fore-casting researches should be planned and propelled in relation to fungicide spray scheduling or decision-making of control activities.

SNR and ADC Value Change before and after the injection of contrast medium during DWI test on metastatic spinal cancer patients (전이성 척추암 환자의 확산강조영상 검사 시 조영제 주입 전.후 ADC값의 변화에 대한 고찰)

  • Kim, Eng-Chan;Kim, Ki-Hong;Park, Cheol-Soo;Lee, Sun-Yeob;Yoo, Heung-Joon;Cho, Jae-Hwan;Jang, Hyun-Cheol;Kim, Bo-Hui;Han, Man-Seok
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.1
    • /
    • pp.37-49
    • /
    • 2011
  • To examine the possible changes in the SNRs, CNRs, and ADC values for lumbar spines with metastasis based on the DW images before and after contrast agent injection taken from metastatic spinal cancer patients using a 1.5 T MR machine. The quantitative analysis revealed that in case of spinal cancer subjects, both SNRs and CNRs at all of those assessed locations significantly increased on the DWI after contrast agent injection compared to before, while on the ADC map images, SNRs significantly decreased. On the other hand, significantly decreased ADC values at all the assessed locations were found on the ADC map images. With reference to the normal group, significantly increased SNRs were found at all of the assessed locations on the DWI image after injection compared to before, while significantly decreased SNRs were found on the ADC map images. Also, significantly decreased ADC values at all the assessed locations were found on the ADC map images. For the qualitative analysis, after contrast agent injection, significantly increased signal intensities were found at the locations with spinal cancer on the DWI. In contrast, significantly decreased signal intensities were found on the ADC map images. The implication from the results showing that SNR and CNR significantly increased while ADC value significantly decreased at, above, and below the location of metastatic spinal cancer on DWI after contrast agent injection is that DWI obtained after contrast agent injection can be made available for wider application to vertebral disorders.

A Study on the Image Quality According to the Change of Flip Angle in Flow-Related Enhancement Magnetic Resonance Angiography (유속증강 자기공명혈관조영술에서 숙임각 변화에 따른 영상의 질 연구)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.2
    • /
    • pp.201-208
    • /
    • 2018
  • The purpose of this study was to investigate the optimal flip angle by measuring the SNR and CNR according to the angle of changes of the MRI technique using the Image J program. A total of 30 normal volunteers were assessed by using a 1.5T magnetic resonance imaging system (Philips, Medical System, Achieva). For the MRI angiography, we set the region of interest in four regions and evaluated the SNR and CNR. The statistical significance of SNR and CNR was calculated by one-way ANOVA using quantitative analysis at five different positions. The Bonferroni method was used for post-hoc analyzes. Statistical significance was determined by using ANOVA analysis at p<0.05 and Bonferroni method was used as a post-hoc analysis. The results of this study, the measurement values of ACA(SNR:$876.59{\pm}14.22$, CNR:$1999.7{\pm}12.5$), PCA(SNR:$863.48{\pm}13.29$, CNR:$1870.18{\pm}12.56$), ICA(SNR:$1116.87{\pm}08.34$, CNR:$2979.37{\pm}14.69$) and MCA(SNR:$848.66{\pm}15.25$, CNR:$2199.25{\pm}13.48$) were obtained with the high signal intensity at $25^{\circ}$(p<0.05). The values of a1, a2, a3, p1, p2, p3, m1, m2 and m3 were also the same (p<0.05). Post-hoc analysis results, There was a statistically significant difference (p=0.000) between $10^{\circ}$, $15^{\circ}$, $20^{\circ}$ on the $25^{\circ}$ reference for the flip angle, but no significant results were obtained with $30^{\circ}$(p<0.05). In concision, because the signal intensity decreased at $30^{\circ}$, this study revealed that the optimal flip angles were $25^{\circ}$ in cerebrovascular MR angiography.

Usefulness of Permeability Map by Perfusion MRI of Brain Tumor the Grade Assessment (뇌종양의 등급분류를 위한 관류 자기공명영상을 이용한 투과성영상(Permeability Map)의 유용성 평가)

  • Bae, Sung-Jin;Lee, Joo-Young;Chang, Hyuk-Won
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.325-334
    • /
    • 2009
  • Purpose : This study was conducted to assess how effective the permeability ratio and relative cerebral blood volume ratio are to tumor through perfusion MRI by measuring and reflecting the grade assessment and differential diagnosis and the permeability and relative cerebral blood volume of contrast media plunged from blood vessel into organ due to breakdown of blood-brain barrier in cerebral. Subject and Method : Subject of study was 29 patients whose diagnosis were confirmed by biopsy after surgery and 550 (11 slice$\times$50 image) perfusion MRI were used to make image of relative cerebral blood volume with the program furnished on instrument. The other method was to transmit to private computer and the image analysis was made additionally by making image of relative cerebral blood volume-reformulated singular value decomposition, rCBV-rSVD and permeability using IDL.6.2. In addition, Kruskal-wallis test tonggyein non numerical average by a comparative analysis of brain tumors Results : The rCBV ratio (Functool PF; GE Medical Systems and IDL 6.2 program by analysis) and permeability ratio of tumors were as follows; high grade glioma(n=4), (14.75, 19.25) 13.13. low grade astrocytoma(n=5) (14.80, 15.90) 11.60, glioblastoma(n=5) (10.90, 18.60), 22.00, metastasis(n=6) (11.00, 15.08). 22.33. meningioma(n=6) (18.58, 7.67), 5.58. oliogodendroglioma(n=3) (23.33, 16.33, 15.67. Conclusion : It was not easy to classify the grade with the relative cerebral blood volume ratio measured by using the relative cerebral blood image by type of tumors, however, permeability ratio measured by permeability image revealed that the higher the grade of tumor, the higher the measured permeability ratio, showing the assessment of tumor grade is more effective to differential diagnosis.

  • PDF

The Study on the Perceptions of Radiological Technologist in Medical Imaging Equipment Used by the Oriental Doctor (한의사의 의료영상장비 사용에 대한 방사선사의 인식도)

  • Choi, Jae-Ho;Kang, Gi-Bong;Kim, Sang-Hyun;Kim, Tae-Hee;Kim, Gyoo-Hyung;Lee, Mi-Hwa;Ahn, Jung-Seong;Hong, Seong-Wan;Lee, Jae-Seok;Kwon, Ick-Su;Park, Jae-Yoon
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.109-120
    • /
    • 2017
  • In order to examine how Radiological Technologists perceive the oriental doctor's use of Medical Imaging Equipment, surveys were conducted for the members of the Korean Radiological Technologists Association. The total number of respondents were 515 and 481, with 34 insincere responses removed caused of nonvalidated answer. The results of the analysis are as follows. Although there were no statistical significance in the difference in perception by location of residence, work place, and educational background, respondents with higher education showed a tendency to agree on the use of comprehensive medical imaging equipment, but tended to oppose the use of special medical imaging equipment. Differences in perception by gender showed a greater negative perception toward the oriental doctor's use of medical imaging equipment by women than men. In particular, women showed more negative tendency for oriental doctor's use of special medical imaging equipment such as MRI, CT, and ultrasound equipment compared to men, and this was statistically significant. The difference in perception by age showed that the oriental doctor's use of medical imaging equipment was negative in the 20~30s, neutral in the 40~50s, and positive in the 60s, which were statistically significant. The difference in perception by work experience showed that the longer the work experience was, the more positive it was toward oriental doctor's use of medical imaging equipment. Specifically, the most favorable tendency was found with work experience of more than 30 years, which was statistically significant. The results of this study revealed the Radiological Technologists' perceptions on the oriental doctor's use of Medical Imaging Equipment and this can contribute to the direction of public health promotion in the future.

A Study on Total Mercury and Methylmercury in Commercial Tuna, Billfish, and Deep-sea Fish in Seoul Metropolitan City (서울시 유통 다랑어류, 새치류 및 심해성 어류의 총수은 및 메틸수은 축적에 대한 고찰)

  • Kim, Jin-Ah;Yuk, Dong-Hyun;Park, Young-Ae;Choi, Hee-Jin;Kim, Youn-Cheon;Kim, Moo-Sang
    • Korean Journal of Food Science and Technology
    • /
    • v.45 no.3
    • /
    • pp.376-381
    • /
    • 2013
  • In this study, we monitored total mercury and methylmercury concentrations in tuna, billfish, and deep-sea fish distributed in Seoul city. With the acquired data, we carried out statistical analysis and an exposure assessment for intake. The mean concentrations (mg/kg) of total mercury and methylmercury were $0.32{\pm}0.31/0.20{\pm}0.20$ for tuna, $0.43{\pm}0.48/0.20{\pm}0.17$ for patagonian toothfish, $0.99{\pm}0.72/0.51{\pm}0.40$ for billfish and $1.20{\pm}0.70/0.95{\pm}0.51$ for sharks, respectively. We found that sharks, billfish, patagonian toothfish, and tuna were more contaminated with total mercury and methylmercury, in sequence, and that 66% of the total mercury concentration consisted of methylmercury, on average. Although the estimated weekly intakes of methylmercury from commercial deep-sea fish were lower than the weekly intakes recommended by the Joint FAO/WHO Expert Committee on Food Additives (JECFA), we identified that the total mercury and methylmercury concentrations in tuna, billfish, and deep-sea fish continued to increase with the passage of time. Therefore, we confirmed the necessity of continuous monitoring and comprehensive analysis for general safety.

Analytical Performance of Sensitivity and Specificity for Rapid Multiplex High Risk Human Papillomavirus Detection Kit: HPV ViroCheck (고위험군 HPV 검출을 위한 분석적 민감도와 특이도 성능평가)

  • Park, Sunyoung;Yoon, Hyeonseok;Bang, Hyeeun;Kim, Yeun;Choi, Seongkyung;Ahn, Sungwoo;Kim, Jungho;Lee, Suji;Yang, Ji Yeong;Lee, Dongsup
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.49 no.4
    • /
    • pp.446-454
    • /
    • 2017
  • Human papillomaviruses (HPVs) are major causes of cervical cancer. Sixteen high risk HPVs, including HPV 16, HPV 18, HPV31, HPV 33, HPV 35, HPV 39, HPV 45, HPV 51, HPV 52, HPV 53, HPV 56, HPV 58, HPV 59, HPV 66, HPV 68, and HPV 69 are found in cervical cancer. HPVs 16 and 18 are mainly presented in 70% of cervical cancer. Therefore, identifying the presence of these high-risk HPVs is crucial. The objective of this study is to establish the HPV ViroCheck for detecting 16 HR-HPVs and genotypes of HPVs 16 and 18, as well as to analyze the analytical performance of HPV ViroCheck. We performed the analytical sensitivity of HPV E6 / E7 genes of 16 high risk HPVs to confirm the limit of detection. Then, a cross reactivity of HPV ViroCheck with microorganisms and viruses related to the cervix were analyzed for analytical specificity. Analytical sensitivity of high risk HPV genotypes ranged from 1 to 100 copies when using cloned DNAs. The limit of detection was 10 cells for both SiHa and HeLa cells. Cervical-related microorganisms and viruses did not show cross-reactivity to HPV DNA. Moreover, the intra- and inter-assay coefficient variations (CVs) were below 5%. In conclusion, HPV Virocheck will be useful for the detection of 16 HR HPVs, as well as HPV 16 and HPV 18 genotypes rapidly.

Privacy protection of seizure and search system (압수수색과 개인정보 보호의 문제)

  • Kim, Woon-Gon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.20 no.5
    • /
    • pp.123-131
    • /
    • 2015
  • Bright development of information communication is caused by usabilities and another case to our society. That is, the surveillance which is unlimited to electronic equipment is becoming a transfiguration to a possible society, and there is case that was able to lay in another disasters if manage early error. Be what is living on at traps of surveillance through the Smart phones which a door of domicile is built, and the plane western part chaps, and we who live on in these societies are installed to several places, and closed-circuit cameras (CCTV-Closed Circuit Television) and individual use. On one hand, while the asset value which was special of enterprise for marketing to enterprise became while a collection was easily stored development of information communication and individual information, the early body which would collect illegally was increased, and affair actually very occurred related to this. An investigation agency is endeavored to be considered the digital trace that inquiry is happened by commission act to the how small extent which can take aim at a duty successful of the inquiry whether you can detect in this information society in order to look this up. Therefore, procedures to be essential now became while investigating affair that confiscation search regarding employment trace of a computer or the telephone which delinquent used was procedural, and decisive element became that dividing did success or failure of inquiry whether you can collect the act and deed which was these electronic enemy. By the way, at this time a lot of, in the investigation agencies the case which is performed comprehensively blooms attachment while rummaging, and attachment is trend apprehension to infringe discretion own arbitrary information rising. Therefore, a lot of nation is letting you come into being until language called exile 'cyber' while anxiety is exposed about comprehensive confiscation search of the former information which an investigation agency does. Will review whether or not there is to have to set up confiscation search ambit of electronic information at this respect how.

Analysis of 1,000 Cases of Abdominal Ultrasonography Performed by a Pediatrician (소아과 의사에 의해 시행된 복부 초음파 검사 1,000예에 대한 분석)

  • Bae, Sang-In;Park, Jae-Hong
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.10 no.1
    • /
    • pp.28-35
    • /
    • 2007
  • Purpose: The aim of this study was to evaluate the clinical usefulness of ultrasound examination of children performed by a pediatrician. Methods: One thousand children who presented with symptoms of a gastrointestinal disorder and underwent abdominal ultrasound evaluation in the Department of Pediatrics, between January 2003 and June 2006, were included in this study. We analyzed the patient's medical records and ultrasound results retrospectively. Results: Among the 1,000 patients, 58.4% were male and 41.6% were female. The mean age of the patients was $4.7{\pm}4.0$ years. The main reasons for ultrasound were abdominal pain (43.9%), vomiting (17.3%), elevated liver enzymes (11.8%), and jaundice (9.8%). Abnormal ultrasound findings were present in 57.9% of cases. The major abnormal findings were mesenteric lymphadenitis (29.2%), fatty liver (12.1%), hepatitis (6.4%), hepatosplenomegaly (6.2%), and acute appendicitis (4.8%). The time interval between the initial medical evaluation and the ultrasound evaluation was within 24 hours in most cases (78.5%). The main findings in children with abdominal pain were mesenteric lymphadenitis (32.6%), fatty liver (5.9%), intussusception (2.7%), and acute appendicitis (2.7%). The main findings in children with vomiting were mesenteric lymphadenitis (12.7%), hypertrophic pyloric stenosis (10.4%), and acute appendicitis (3.5%). The major ultrasound findings in children with urinary tract diseases were hydronephrosis (45.4%), urolithiasis (21.5%) and cystic renal disease (18.1%). Conclusion: Ultrasound examination played an important role as a non-invasive and prompt screening examination for detection of abdominal diseases. Ultrasound was an important tool for pediatricians to determine timely information for patient management.

  • PDF