• Title/Summary/Keyword: 기관회전수

Search Result 99, Processing Time 0.027 seconds

A Statistical Survey of Foreign Bodies in Air and Food Passage (Report V) (식도 및 기도이물의 통계적 고찰(제5보))

  • 김기령;홍원표;이춘근;이정권;박기현;김상기
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1979.05a
    • /
    • pp.6.2-6
    • /
    • 1979
  • Foreing bodies of the esophagus and tracheobronchus are likely to occur whenever a child places an inedible object in the mouth and are common in the older age group particularily in edentulous individuals or preexisting disease. Our department had already reported the statistical survey at first in 1954, successively in 1962, 1963 and 1968, respectively according to the age, sex, variety of foreign bodies, location and duration of the lodgement. Now, we have experienced the new 186 cases during the consecutive 5 year period from January 1973 to December 1977 and reported as a 5th report comparing with previous report. The results were as follows. 1. In the incidence of foreign bodies, coins were the most common and pointed metal, disc, bony fragment were followed in order in the esophagus while the peanut and corn were common in the air passage. 2) 79 cases (56.4%) were males and 61 cases (43.6%) were females in the esophagus, which was not a significant difference to note. But in the air passage, males accounted for 33 cases (71.7%) compared to 13 cases (28.3%) of females. 3) In the aspect of age incidence, child 10 years or under accounted for almost all cases in the esophagus as well as in the air passage. 4) In the location of foreign bodies in the esophagus, the first narrowing was the most common, while in the air passage right bronchus had a high incidence but the difference of incidence between right bronchus and left bronchus was not remarkable. 5) The duration of lodgement was 24 hours or less in more than half of the all cases. 6) In the aspect of kind of coin, 10 won coins accounted for majority of the cases (67.0%) but the incidence of 100 won coins were tend to increase gradually in these years.

  • PDF

A Study on Exhaust Gas Characteristics of Off-road Mechanical Diesel Engine According to EGR Map Application (Off-Road 기계식 디젤엔진의 EGR Map 적용에 따른 배출가스 특성 연구)

  • Kim, HoonMyung;Kang, JeongHo;Han, DaHye;Ha, HyeongSoo;Jung, HakSup;Pyo, SuKang;Ahn, JuengKyu
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.8
    • /
    • pp.665-670
    • /
    • 2014
  • Because reducing atmospheric pollution is becoming a serious issue, studies are actively focusing on exhaust gas reduction. This study was conducted to determine the emission characteristics when applying an EGR system, the main approach used for NOx reduction, to an off-road mechanical diesel engine. For the application of the EGR system, the emission characteristics in consideration of the engine conditions were analyzed. The optimum EGR ratio for NOx emission reduction was determined by applying variable EGR conditions for each engine speed condition. Considering the above process, the emission characteristics of the modified EGR condition are compared with those of other conditions (non-EGR and existing EGR condition) in the NRTC mode. Consequently, NOx emission was reduced by around 42 compared with the non-EGR condition when using the modified EGR map.

Estimation of Engine Output for Marine Diesel Engines (선박용 디젤엔진의 출력산정에 관한 연구)

  • Jung, Kyun-Sik;Lee, Jin-Uk;Jung, Jin-Ah;Choi, Jae-Sung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.4
    • /
    • pp.436-442
    • /
    • 2011
  • To obtain the engine output correctly is basically very important factor for estimating a engine performance. But, it has been reported that the IHP measured from electronic indicator such as MIPS(Mean Indication Pressure System) has a deviation compared to mechanical indicator. It was reported by authors that the uncertainty of crank angle for TDC position could be one of the reasons. In this paper, the uncertainty of crank angle for TDC position and its influence to engine output were investigated respectively about M/E and G/E for marine diesel engines. For the purpose, two sampling methods of pressure in cylinder were considered which were 'angle base sampling' and 'time base sampling'. Angle base sampling is real crank angle acquired from angle encoder which is attached to crank shaft and time base sampling is crank angle calculated by detected revolution with Z-pluse of encoder. Time base sampling is same method of MIPS. This paper concluded that time base sampling method is not suitable for obtaining the output of marine diesel engine on board because of instantaneous speed variation and load fluctuation. Also it is verified that the variation of engine speed by load fluctuation should be one of reasons additionally in case of M/E.

Evaluation of useful treatment which uses dual-energy when curing lung-cancer patient with stereotactic body radiation therapy (폐암 환자의 정위적방사선 치료 시 이중 에너지를 이용한 치료 방법의 유용성 평가)

  • Jang, Hyeong Jun;Lee, Yeong Gyu;Kim, Yeong Jae;Park, Yeong Gyu
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.2
    • /
    • pp.87-99
    • /
    • 2016
  • Purpose : This study will evaluate the clinical utility by applying clinical schematic that uses monoenergy or dual energy as according to the location of tumors to the stereotactic radiotherapy to compare the change in actual dose given to the real tumor and the dose that locates adjacent to the tumor. Materials and Methods : CT images from a total of 10 patients were obtained and the clinical planning were planned based on the volumetric modulated arc therapy on monoenergy and dual energy. To analyze the change factor in the tumor, Comformity Index(CI) and Homogeneity Index(HI) and maximum dose quantity were each calculated and comparing the dose distribution on normal tissues, $V_{10}$ and $V_5$, first ~ fourth ribs closest to the tumor ($1^{st}{\sim}4^{th}$ Rib), Spinal Cord, Esophagus and Trachea were selected. Also, in order to confirm the accuracy on which the planned dose distribution is really measured, the 2-dimensional ion chamber array was used to measure the dose distribution. Results : As of the tumor factor, CI and HI showed a number close to 1 when the two energies were used. As of the maximum dose, the front chest wall showed 2% and the dorsal tumor showed equivalent value. As of normal tissue, the front chest wall tumors were reduced by 4%, 5% when both energies were used in the adjacent rib and as of trachea, reduced by 11%, 17%. As of the dose in the lung, as of $V_{10}$, it reduced by 1.5%, $V_5$ by 1%. As of the rear chest wall, when both energies were used, the ribs adjacent to the tumors showed 6%, 1%, 4%, 12% reduction, and in the lung dose distribution, $V_{10}$ reduced by 3%, and $V_5$ reduced by 3.1%. The dose measurement in all energies were in accordance to the results of Gamma Index 3mm/3%. Conclusion : It is considered that rather than using monoenergy, utilizing double energy in the clinical setting can be more effectively applied to the superficial tumors.

  • PDF

Evaluation of the Usefulness of MapPHAN for the Verification of Volumetric Modulated Arc Therapy Planning (용적세기조절회전치료 치료계획 확인에 사용되는 MapPHAN의 유용성 평가)

  • Woo, Heon;Park, Jang Pil;Min, Jae Soon;Lee, Jae Hee;Yoo, Suk Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.115-121
    • /
    • 2013
  • Purpose: Latest linear accelerator and the introduction of new measurement equipment to the agency that the introduction of this equipment in the future, by analyzing the process of confirming the usefulness of the preparation process for applying it in the clinical causes some problems, should be helpful. Materials and Methods: All measurements TrueBEAM STX (Varian, USA) was used, and a file specific to each energy, irradiation conditions, the dose distribution was calculated using a computerized treatment planning equipment (Eclipse ver 10.0.39, Varian, USA). Measuring performance and cause errors in MapCHECK 2 were analyzed and measured against. In order to verify the performance of the MapCHECK 2, 6X, 6X-FFF, 10X, 10X-FFF, 15X field size $10{\times}10$ cm, gantry $0^{\circ}$, $180^{\circ}$ direction was measured by the energy. IGRT couch of the CT values affect the measurements in order to confirm, CT number values : -800 (Carbon) & -950 (COUCH in the air), -100 & 6X-950 in the state for FFF, 15X of the energy field sizes $10{\times}10$, gantry $180^{\circ}$, $135^{\circ}$, $275^{\circ}$ directionwas measured at, MapPHAN allocated to confirm the value of HU were compared, using the treatment planning computer for, Measurement error problem by the sharp edges MapPHAN Learn gantry direction MapPHAN of dependence was measured in three ways. GANTRY $90^{\circ}$, $270^{\circ}$ in the direction of the vertically erected settings 6X-FFF, 15X respectively, and Setting the state established as a horizontal field sizes $10{\times}10$, $90^{\circ}$, $45^{\circ}$, $315^{\circ}$, $270^{\circ}$ of in the direction of the energy-6X-FFF, 15X, respectively, were measured. Without intensity modulated beam of the third open arc were investigated. Results: Of basic performance MapCHECK confirm the attenuation measured by Couch, measured from the measured HU values that are assigned to the MAP-PHAN, check for calculation accuracy for the angled edge of the MapPHAN all come in a range of valid measurement errors do not affect the could see. three ways for the Gantry direction dependence, the first of the meter built into the value of the Gantry $270^{\circ}$ (relative $0^{\circ}$), $90^{\circ}$ (relative $180^{\circ}$), 6X-FFF, 15X from each -1.51, 0.83% and -0.63, -0.22% was not affected by the AP/PA direction represented. Setting the meter horizontally Gantry $90^{\circ}$, $270^{\circ}$ from the couch, Energy 6X-FFF 4.37, 2.84%, 15X, -9.63, -13.32% the difference. By-side direction measurements MapPHAN in value is not within the valid range can not, because that could be confirmed as gamma pass rate 3% of the value is greater than the value shown. You can check the Open Arc 6X-FFF, 15X energy, field size $10{\times}10$ cm $360^{\circ}$ rotation of the dose distribution in the state to look at nearly 90% pass rate to emerge. Conclusion: Based on the above results, the MapPHAN gantry direction dependence by side in the direction of the beam relative dose distribution suitable for measuring the gamma value, but accurate measurement of the absolute dose can not be considered is. this paper, a more accurate treatment plan in order to confirm, Reduce the tolerance for VMAT, such as lateral rotation investigation in order to measure accurate absolute isodose using a combination of IMF (Isocentric Mounting Fixture) MapCHEK 2, will be able to minimize the impact due to the angular dependence.

  • PDF

A Study on the Water Reuse Systems (중수도개발연구(中水道開發研究))

  • Park, Chung Hyun;Lee, Seong Key;Chung, Jae Chul
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.4 no.4
    • /
    • pp.113-125
    • /
    • 1984
  • Water supply has been mainly dependent on the construction of the dams in Korea. It is difficult, however, to continue to construct dams for many reasons, such as the decrease of construction sites, the increase of construction costs, the compensation of residents in flooded areas, and the environmental effects. Water demands have increased and are expected to continue increasing due to the concentration of people in the cities, the rise of the living standard, and rapid industrial growth. It is acutely important to find countermeasures such as development of ground water, desalination, and recycling of waste water to cope with increasing water demands. Recycling waste water includes all means of supplying non-potable water for their respective usages with proper water quality which is not the same quality as potable water. The usages of the recycled water include toilet flushing, air conditioning, car washing, yard watering, road cleaning, park sprinkling, and fire fighting, etc. Raw water for recycling is obtained from drainage water from buildings, toilets, and cooling towers, treated waste water, polluted rivers, ground water, reinfall, etc. The water quantity must be considered as well as its quality in selecting raw water for the recycling. The types of recycling may be classified roughly into closed recycle systems and open recycle systems, which can be further subdivided into individual recycle systems, regional recycle systems and large scale recycle system. The treatment methods of wastewater combine biochemical and physiochemical methods. The former includes activated sludge treatment, bio-disc treatment, and contact aeration treatment, and the latter contains sedimentation, sand filtration, activated carbon adsorption, ozone treatment, chlorination, and membrane filter. The recycling patterns in other countries were investigated and the effects of the recycling were divided into direct and indirect effects. The problems of water reuse in recycle patterns were also studied. The problems include technological, sanitary, and operational problems as well as cost and legislative ones. The duties of installation and administrative organization, structural standards for reuse of water, maintenance and financial disposal were also studied.

  • PDF

Bone Conduction Loss in Chronic Otitis Media (만성중이염에서의 골도장애)

  • 김종선;김시영
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1979.05a
    • /
    • pp.3.2-3
    • /
    • 1979
  • Bone conduction loss is one of the most common complication in chronic otitis media, and is mostly high frequency loss. Of 233 tympanomastoidectomy ears, 187 ears were considered eligible for this study. A histopathological change was examined in the natural otitis media of guinea pigs. It is our intention to analyze the pattern of bone conduction loss in chronic otitis media, and to correlate this findings with clinical and pathological changes in human and animal otitis media. l) In unilateral cases, a significant difference in bone conduction threshold was observed between normal and diseased ears, and between each frequency with significant interaction between 2KHz and 4KHz (p 0.01). 2) Using one way analysis of variance, mean bone conduction was compared with the duration of disease. We observed a significant difference (p 0.05) between each group of duration, except between 11-15 and 15-20 years group. 3) A comparison of bone conduction between stapes loss group and intact stapes group revealed significant t ratio (p 0.01) at each frequency. The effect of stapes loss on each frequency was evaluated, using one way analysis of variance. there were significant difference(p 0.05) between 250Hz and 500Hz. and between 2KHz and 4KHz. 4) A comparison of bone conduction between round window obliteration and nonobliteration group revealed significant t ratio (p 0.01) at each frequency. Using one way analysis of variance. the effect of round window obliteration was evaluated in each frequency. We observed significant difference (p 0.05) between 250Hz and 500Hz. and between 2KHz and 4KHz. 5) A comparison of bone conduction between cholesteatoma and non -cholesteatoma group revealed significant t ratio (p 0.01) only in 2KHz and 4KHz. No significant differency was observed in mean bone conduction. 6) In a histopathological study of natural otitis media in guinea pig, we observed inflammatory infiltration of the round window membrane, serofibrinous precipitate in the scala tympani, and degeneration of the organ of Corti most significant near the basal turn. These changes would explain high tone bone conduction loss in the process of chronic otitis media.

  • PDF

Ontogeny of the Digestive Organ during Early Life Stages of the Black Sea Bream, Acanthopagrus schlegeli(Teleostei: Sparidae) (감성돔(Acanthopagrus schiegeli)의 초기생활사 동안 소화기관 발달)

  • LEE Jung Sick;KIM Heung-Yun;BYUN Soon Gyu;KIM Jin Do;GO Chang Soon;CHIN Pyung
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.33 no.2
    • /
    • pp.129-136
    • /
    • 2000
  • Differentiation and development of the digestive organ of the black sea bream, AcanHepagus schlegeli were studied by means of histological methods. The hatched lawn if TL(total length) $2.0 mm (n=10)$ had a yolk sac of $1,000{\times}590 {\mu}m$ and simple straight digestive tract, which was composed of cuboidal epithelium. In the pre-larval stage of TL $3.5 mm$, digestive tract could be distinguished into esophagus, stomach and intestine, and the exocrine glands were appeared in the pancreas. In this stage mucosal folds, eosinophilic granule cells and brush border were observed in the posterior intestine. Yolky materials were completely absorbed and the brush border was recognized in the free surface of anterior intestine in TL $3.7 mm$. In the stomach mucosal folds began to appear from TL $4.0 mm$. In this time the zymogen granules were recognized in the cytoplasm of pancreatic exocrine cells. In the post-larval stage ranged from $4.5 to 5.0 mm$ in TL, hepatic cords started to develop, and the mucous secretory cells of PAS positivewere observed at esophagus and intestine. In the post-larval stage ranged from $6.3 to 7.0 mm$ in TL, histological layer of esophagus and intestine could be distinguished into serous membrane, muscular layer, submucosal layer and mucosal layer. From over TL $9.0 mm$, stomach could be distinguished into cardiac, fundic and pyloric portion, and the gastric gland began to appear at mucosal fold of fundic stomach. In the juvenile stage ranged from $10.0 to 11.0 mm$ in TL, histological structures of esophagus and intestine were similar to those of adult. From over TL $15.0 mm$, histological structures of stomach were similar to those of adult. Structural and functional digestive organ of black sea bream was present from the juvenile stage ranged from $15.0 to 17.0 mm$ in TL.

  • PDF

Analysis of the Spatial Dose Rates during Dental Panoramic Radiography (치과 파노라마 촬영에서 공간선량률 분석)

  • Ko, Jong-Kyung;Park, Myeong-Hwan;Kim, Yongmin
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.509-516
    • /
    • 2016
  • A dental panoramic radiography which usually uses low level X-rays is subject to the Nuclear Safety Act when it is installed for the purpose of education. This paper measures radiation dose and spatial dose rate by usage and thereby aims to verify the effectiveness of radiation safety equipment and provide basic information for radiation safety of radiation workers and students. After glass dosimeter (GD-352M) is attached to direct exposure area, the teeth, and indirect exposure area, the eye lens and the thyroid, on the dental radiography head phantom, these exposure areas are measured. Then, after dividing the horizontal into a $45^{\circ}$, it is separated into seven directions which all includes 30, 60, 90, 120 cm distance. The paper shows that the spatial dose rate is the highest at 30 cm and declines as the distance increases. At 30 cm, the spatial dose rate around the starting area of rotation is $3,840{\mu}Sv/h$, which is four times higher than the lowest level $778{\mu}Sv/h$. Furthermore, the spatial dose rate was $408{\mu}Sv/h$ on average at the distance of 60 cm where radiation workers can be located. From a conservative point of view, It is possible to avoid needless exposure to radiation for the purpose of education. However, in case that an unintended exposure to radiation happens within a radiation controlled area, it is still necessary to educate radiation safety. But according to the current Medical Service Act, in medical institutions, even if they are not installed, the equipment such as interlock are obliged by the Nuclear Safety Law, considering that the spatial dose rate of the educational dental panoramic radiography room is low. It seems to be excessive regulation.