• Title/Summary/Keyword: 기관지내 근접치료

Search Result 8, Processing Time 0.024 seconds

Remote Afterloading Hish Dose Rate (HDR) Endobronchia1 Brachytherapy (원격조정 고선량 기관지내 근접 치료)

  • Chang Hyesook;Choi Eun Kyung;Yi Byong Yong;Kim Won Dong;Kim Woo Sung;Koh Youn Suck
    • Radiation Oncology Journal
    • /
    • v.9 no.2
    • /
    • pp.227-232
    • /
    • 1991
  • Authors described the remote afterloading endobronchial brachytherapy (EBBT technique using the microSelectron HDR Ir-192 and the Asan Medical Center experience. Total 28 EBBT in 9 patients were performed since November 1989 and 24 EBBT in 8 patients were emploiyed for palliation and 3 EBBT in 1 patient was treated curatively. Authors observed a significant relief of obstructive symptom with tumor regression in 7 patients out of 8 who were treated palliatively but one of them died of pulmonary congestion in 3 weeks after EBBT One patient with prior therapy of extensive electrocautery expired within 1 day after 2nd EBBT procedure with massive hemorrhage from the lesion. EBBT procedure has been tolerable and can be performed as an outpatient.

  • PDF

The Palliative Effect of Endobronchial Brachytherapy for Previously Irradiated Patients with Lung Cancer (이전에 외부방사선치료를 받은 폐암 환자에서 기관지내 근접치료의 고식적 효과)

  • Park, Young-Je;Kim, Kwang-Taik;Yang, Dae-Sik;Lee, Suk;Kim, Chul-Yang
    • Radiation Oncology Journal
    • /
    • v.25 no.3
    • /
    • pp.177-184
    • /
    • 2007
  • Purpose: To evaluate the palliative effect of endobronchial brachytherapy (EBB) for patients with lung cancer that previously received external beam radiotherapy (EBRT). Materials and Methods: From July 1992 to May 2003, 29 patients with a recurrent or persistent lung cancer were treated with palliative EBB at our institute. EBB consisted of three fractions (once a week) of a dose of 5 Gy using the high dose-rate remote afterloader. Symptomatic improvement was assessed subjectively, and patients were divided into two groups according to whether symptoms were improved or not. Factors such as age, performance status, duration from EBRT to EBB and the location of the tumor were compared between the improved and unimproved groups of patients. Results: Overall symptomatic improvement was found in 27 out of 52 symptoms (52%). Improvement as to the type of symptoms was seen in 41 %, 50%, 82% and 33% of patients with cough, dyspnea, hemoptysis, and obstructive pneumonia respectively. The rate of improvement of hemoptysis was more than that of cough (p<0.05). The median time to symptom relapse was 5 months. The improved patient group (n=17, 59%) had a better performance status and longer duration from EBRT to EBB than the unimproved patient group (p<0.05). Lesions located in the distal trachea and/or main bronchus were found more frequently in the improved group of patients than in the unimproved group of patients, but the difference was not statistically significant (p=0.06). Fatal complications developed in two patients (7%), which were a hemoptysis and bronchopleural fistula respectively. Conclusion: Symptom improvement was found in 60% of patients after EBB and improvement was maintained for 5 months. Palliative EBB, even when EBRT was given previously, can be effective for a patient that has an endobronchial symptom, such as hemoptysis, and for a patient with good performance and a long duration from previous EBRT to EBB.

The Effects of High Dose Rate Brachytherapy in Recurrent Obstructive Bronchogenic Cancer after External Irradiation Therapy (외부 방사선 치료 조사후 재발한 기관지내 악성종양에서 고선량율 근접조사치료(High Dose Rate Brachytherapy)의 효과)

  • Cho, Jae-Youn;In, Kwang-Ho;Suh, Jung-Kyung;Kang, Sea-Yong;Shim, Jae-Jeong;Kang, Kyung-Ho;Kim, Kwang-Taak;Kim, Cheol-Yong;Yoo, Sa-Hwa
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.1
    • /
    • pp.68-76
    • /
    • 1998
  • Background: Patients with centrally recurred bronchogenic carcinoma make a complaint of many symptoms like hemoptysis, cough & dyspnea. At these conditions, the goal of treatment is only to relieve their symptoms. High dose rate brachytherapy(HDR-BT) is the palliative treatment modality of centrally located endobronchial tumor regardless of previous external irradiation(XRT) on the same site in symptomatic patients. Methods: We studied the effects of HDR-BT in 26 patients with symptomatic recurrent lung cancer. Patients(male: 24, mean age: 54yrs)were treated with HDR-BT underwent bronchoscopic placement of $^{192}Ir$ HDR after loading unit(Gammamed$^{(T)}$, Germany) to deliver 500cGY intraluminal irradiation at a depth of 1cm every lwk on 3 occasions. Evaluation at base line and 4wks after HDR brachytherapy included chest X-ray, bronchscopy, symptoms (Standadized Scale for dyspnea,cough,hemoptysis), and Karnofsky performance scale. Results: Endobronchial obstruction was improved in 11/26 patients(37%). Atelectasis in chest X-ray was improved in 5/15 patients(33%). Hemoptysis, dyspnea & cough were improved in 5/10 patients (50%), 5/8 patients (62%) & 10/18 patients (56%) respectively. Karnofsky performance status was changed from 76.4 scores in pretreatment to 77.6 scores after treatment. During HDR-BT, massive hemoptysis (2 patients) and pneumothorax(1 patient) were occurred as complications. Conclusion: We concluded that HDR-BT gave additional benefits for the control of symptoms and general performance and endobronchial obstruction & atelectasis. And HDR-BT will be an additional treatment for the recurrent and endobronchial obstructive lung cancer.

  • PDF

Remote Afterloading High Dose Rate Brachytherapy AMC EXPERIANCES (원격조정 고선량 근접 치료)

  • Park, Su-Gyeong;Chang, Hye-Sook;Choi, Eun-Kyong;Yi, Byong-Yong;Kim, Jae-Sung
    • Radiation Oncology Journal
    • /
    • v.10 no.2
    • /
    • pp.267-275
    • /
    • 1992
  • Remote afterloading high dose rate brachytherapy (HDRB) is a new technology and needs new biological principle for time and dose schedule. Here, authors attempt to evaluate the technique and clinical outcome in 116 patients, 590 procedures peformed at Asan Medical Center for 3 years. From Sep. 1989 to Aug 1992, 471 procedures of intracavitary radiation in 58 patients of cervical cancer and 26 of nasopharyngeal cancer,79 intraluminal radiation in 12 of esophageal cancer, 11 of endobronchial cancer and 1 Klatskin tumor and 40 interstitial brachytherapy in 4 of breast cancer, 1 sarcoma and 1 urethral cancer were performed. Median follow-up was 7 months with range $1\~31$ months. All procedures except interstitial were performed under the local anesthesia and they were all well tolerated and completed the planned therapy except 6 patients. 53/58 patients with cervical cancer and 22/26 patients with nasopharynx cancer achieved CR. Among 15 patients with palliative therapy, $80{\%}$ achieved palliation. We will describe the details of the technique and results in the text. To evaluate biologic effects of HDRB and optimal time/dose/fractionation schedule, we need longer follow-up. But authors feel that HDRB with proper fractionation schedule may yield superior results compared to the low dose rate brachytherapy considering the advantages of HDRB in safety factor for operator, better control of radiation dose and volume and patients comfort over the low dose brachytherapy.

  • PDF

Short-term Results of Endobronchial Brachytherapy for Malignant Airway Obstructions (악성 기도 폐쇄에 대한 기관내 근접 조사 방사선치료의 단기 임상 경험)

  • Ahn Yong Chan;Lim Do Hoon;Choi Dong Rak;Kim Moon Kyung;Kim Dae Yong;Huh Seung Jae;Kim Ho Joong;Chung Man Pyo;Kwon O Jung;Rhee Chong Heon
    • Radiation Oncology Journal
    • /
    • v.14 no.4
    • /
    • pp.299-306
    • /
    • 1996
  • Purpose : Respiratory symptoms related with malignant airway disease have been the main causes of lowered qualify of life and also sometimes may be life-threatening if not properly managed. The authors report the short-term experiences of endobronchial brachytherapy for symptomatic malignant airway obstruction using high dose rate after-loading brachytherapy unit. Materials and Methdos : Twenty-five Patients with symptomatic malignant airway obstruction were treated with endobronchial brachytherapy between the period of December 1994 and March 1996 at Department of Radiation Oncology of Samsung Medical Center Twenty-one ($84\%$) were patients with non-small cell lung cancer, three with tracheal malignancies, and one with recurrence of esophageal cancer. Twenty Patients were given elective external beam radiation therapy, while six were given endobronchial laser evaporation therapy on emergency bases in addition to endobronchial brachytherapy. Three procedures for each patient were planned and total of 70 procedures were completed. Results : Improvement rates of major respiratory symptoms after endobronchial brachytherapy procedures were $88\%$(22/25). $96\%$(22/23), $100\%$ (15/15), and $100\%$(9/9) for cough, dyspnea, hemoptysis and obstructive pneumonia, respectively. ECOG performance scores were improved in $56\%$ of total patients group, while there was no case with worsened ECOG score. Fifteen patients died and the median interval from the start of treatment to death was 4 months (range: $1\~17$ months), while that of ten survivors was 9 months (range $5\~19$ months). There were five patients with controlled intrathoracic disease, who have survived over one rear. All deaths were associated with uncontrolled local and/or distant disease. Four Patients died of massive fatal hemoptysis, three of who received emergency endobronchial laser evaporation therapy before the start of endobronchial brachytherapy. Conclusion : Endobronchial brachytherapy has been confirmed as an excellent palliative treatment modality improving respiratory symptoms as well as patients' general performance status. Based on the current observations, use of endobronchial brachytherapy in curative setting as a boost technique may be warranted.

  • PDF

A study on the accuracy of source position in HDR brachytherapy according to the curvature of Universal applicator transfer tube and applicator type (원격 후 장전치료기를 사용한 고선량률 근접치료시 기구의 형태와 선원 전달 도관의 곡률 변화에 따른 선원위치 정확성에 관한 고찰)

  • Shin, Hyeon Kyung;Lee, Sang Kyoo;Kim, Joo Ho;Cho, Jeong Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.123-129
    • /
    • 2015
  • Purpose : The goal of this study was to verify and analyze the source position according to the curvature of the universal applicator and 4 different angle applicators when using RALS(Remote After Loading System). Materials and Methods : An interval of 1 cm and 15 second dwell times in each source position were applied for plan. To verify the accuracy of source position, we narrowed the distance between MultiSource container and GAFCHROMIC$^{(R)}$ EBT3 film by 5 cm, 10 cm, 20 cm so that the universal applicator transfer tube had some curvature. Also 4 applicators(Intrauterine tube: $0^{\circ}$, $15^{\circ}$, $30^{\circ}$, Ovoid tube: $65^{\circ}$) were used in the same condition. The differences between desired and actual source position were measured by using Image J. Results : In case of using 4 different angles of applicator with the straight universal applicator transfer tube, the average error was the lowest for $0^{\circ}$ applicator, greatest for $65^{\circ}$ applicator. However, All average errors were within ${\pm}2mm$ recommended in TG-56. When MultiSource container was moved 5 cm, 10 cm, 20 cm towards the EBT3 film, the average errors were beyond ${\pm}2mm$. The first dwell position was relatively located in accuracy, while the second and third dwells were displaced by an increasing magnitude with increasing curvature of the transfer tube. Furthermore, with increasing the angle of applicators, the error of all other dwell positioning was increased. Conclusion : The results of this study showed that both the curvature of universal applicator transfer tube and the angle of applicators affect the source dwell position. It is recommended that using straight universal applicator transfer tubes is followed in all cases, in order to avoid deviations in the delivered source dwell position. Also, It is advisable to verify the actual dwell position, using video camera quality control tool prior to all treatments.

  • PDF

Bedside Estimation of the Length of Nares-Vocal Cord in Children (소아에서의 비공 - 성대간 거리에 관한 예측공식의 유도)

  • Lee, Young-Eun;Shin, Teo-Jeon;Kim, Chong-Chul;Lee, Sang-Hoon;Jang, Ki-Taeg;Kim, Jung-Wook;Kim, Youmg-Jae;Hyun, Hong-Keun;Han, Hyo-Jo;Kim, Hyun-Jeong;Seo, Kwang-Suk
    • Journal of The Korean Dental Society of Anesthesiology
    • /
    • v.11 no.2
    • /
    • pp.141-145
    • /
    • 2011
  • 배경: 협조가 불가능하거나 진정법 하 치과치료가 여의치 않을 경우 전신마취 하 치료를 계획하게 된다. 하지만 전신마취 하 치료시 기관내 삽관이 여의치 않은 경우를 종종 경험하게 된다. 이와같은 경우 기관지경을 이용한 기관내 삽관을 시행한다. 기관지 내시경을 환자의 성문에 근접하게 전진시킬 경우 기관지 내시경 하 시야확보가 용이한 점을 감안 시 비공 - 성대간 거리를 예측하는 것은 매우 유용할 것으로 생각된다. 또한 비공 - 성대간 거리를 추정하게 되면 맹목적 비강내 기관내 삽관을 하는데도 도움이 된다. 방법: 본 연구는 전신마취하 치과치료가 예정되어 있는 62명의 소아환자들을 대상으로 하여 신체변수와 비공 - 성대거리와의 관계를 확인해보고자 하였다. 선형회귀분석을 시행하여 다음과 같은 결론을 도출하였다. 결과: 소아환자들에 있어 비공 - 성대간 거리는 환아의 신장, 체중, 연령 등과 상관관계를 나타내었다. 비공 - 성대간 거리와 상관관계를 보인 변수들 중 에서 신장과의 상관계수가 가장 높았다. 선형회귀분석을 통해 비공 - 성대간 거리를 예측하는 다음과 같은 회귀식을 구하였다. 비공 - 성대간 거리 = (4.8 + 신장(cm)) ${\times}$ 0.07 고찰: 본 연구에서 구해진 회귀식을 이용하여 기도유지가 어려운 소아의 기도유지 하는데 큰 도움이 될 것으로 생각된다.

Optimization of Dose Distribution for High Dose Rate Intraluminal Therapy (고선량율 관내 방사선치료를 위한 종양선량분포의 최적화에 대한 연구)

  • Chu, Sung-Sil;Kim, Gwi-Eon;Loh, Juhn-Kyu
    • Radiation Oncology Journal
    • /
    • v.12 no.2
    • /
    • pp.243-252
    • /
    • 1994
  • The use of high dose rate remote afterloading system for the treatment of intraluminal lesions necessitates the need for a more accurate of dose distributions around the high intensity brachytherapy sources, doses are often prescribed to a distance of few centimeters from the linear source, and in this range the dose distribution is very difficult to assess. Accurated and optimized dose calculation with stable numerical algorithms by PC level computer was required to treatment intraluminal lesions by high dose rate brachytherapy system. The exposure rate from sources was calculated with Sievert integral and dose rate in tissue was calculated with Meisberger equation, An algorithm for generating a treatment plan with optimized dose distribution was developed for high dose rate intraluminal radiotherapy. The treatment volume becomes the locus of the constrained target surface points that is the specified radial distance from the source dwelling positions. The treatment target volume may be alternately outlined on an x-ray film of the implant dummy sources. The routine used a linear programming formulism to compute which dwell time at each position to irradiate the constrained dose rate at the target surface points while minimizing the total volume integrated dose to the patient. The exposure rate and the dose distribution to be confirmed the result of calculation with algorithm were measured with film dosimetry, TLD and small size ion chambers.

  • PDF