• Title/Summary/Keyword: 기계환기

Search Result 552, Processing Time 0.029 seconds

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2012 (설비공학 분야의 최근 연구 동향 : 2012년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwataik;Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Choi, Jong Min;Park, Jun-Seok;Kim, Sumin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.6
    • /
    • pp.346-361
    • /
    • 2013
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2012. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. The conclusions are as follows : (1) The research works on thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and valves, fuel cells and power plants, ground-coupled heat pumps, and general heat and mass transfer systems. Research issues are mainly focused on new and renewable energy systems, such as fuel cells, ocean thermal energy conversion power plants, and ground-coupled heat pump systems. (2) Research works on the heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer, and industrial heat exchangers. Researches on heat transfer characteristics included the results for natural convection in a square enclosure with two hot circular cylinders, non-uniform grooved tube considering tube expansion, single-tube annular baffle system, broadcasting LED light with ion wind generator, mechanical property and microstructure of SA213 P92 boiler pipe steel, and flat plate using multiple tripping wires. In the area of pool boiling and condensing heat transfer, researches on the design of a micro-channel heat exchanger for a heat pump, numerical simulation of a heat pump evaporator considering the pressure drop in the distributor and capillary tubes, critical heat flux on a thermoexcel-E enhanced surface, and the performance of a fin-and-tube condenser with non-uniform air distribution and different tube types were actively carried out. In the area of industrial heat exchangers, researches on a plate heat exchanger type dehumidifier, fin-tube heat exchanger, an electric circuit transient analogy model in a vertical closed loop ground heat exchanger, heat transfer characteristics of a double skin window for plant factory, a regenerative heat exchanger depending on its porous structure, and various types of plate heat exchangers were performed. (3) In the field of refrigeration, various studies were executed to improve refrigeration system performance, and to evaluate the applicability of alternative refrigerants and new components. Various topics were presented in the area of refrigeration cycle. Research issues mainly focused on the enhancement of the system performance. In the alternative refrigerant area, studies on CO2, R32/R152a mixture, and R1234yf were performed. Studies on the design and performance analysis of various compressors and evaporator were executed. (4) In building mechanical system research fields, twenty-nine studies were conducted to achieve effective design of mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, renewable energy systems, and lighting systems in buildings. New designs and performance tests using numerical methods and experiments provide useful information and key data, which can improve the energy efficiency of buildings. (5) In the fields of the architectural environment, studies for various purposes, such as indoor environment, building energy, and renewable energy were performed. In particular, building energy-related researches and renewable energy systems have been mainly studied, reflecting interests in global climate change, and efforts to reduce building energy consumption by government and architectural specialists. In addition, many researches have been conducted regarding indoor environments.

Effect of Intravenous Administration of Tramadol on the Minimum Alveolar Concentration of Isoflurane in Dogs (개에서 트라마돌의 정맥투여가 아이소플루란의 최소폐포농도에 미치는 영향)

  • Seok, Seong-Hoon;Park, Se-Jin;Lee, Seung-Yong;Jin, So-Young;Kim, Young-Ki;Hwang, Jae-Min;Lee, Hee-Chun;Yeon, Seong-Chan
    • Journal of Veterinary Clinics
    • /
    • v.32 no.4
    • /
    • pp.308-312
    • /
    • 2015
  • This study was aimed to evaluate the effects of tramadol hydrochloride on the minimum alveolar concentration of isoflurane ($MAC_{ISO}$) in dogs. Six healthy, female German shepherd dogs (aged 1-2 years) were used in this study. Anesthesia was induced by mask induction and maintained with isoflurane in oxygen. Mechanical ventilation maintained the end-tidal $CO_2$ partial pressure ($P_{ET}CO_2$) from 35 to 45 mmHg throughout the study. A baseline $MAC_{ISO}$ ($MAC_{ISO}B$) was determined starting 45 minutes after induction of anesthesia by clamping a pedal digit until gross purposeful movement was detected. After $MAC_{ISO}B$ determination, dogs received a tramadol loading dose of 3 mg/kg followed by a continuous rate infusion (CRI) of 2.6 mg/kg/h. The determination of $MAC_{ISO}$ after administration of tramadol ($MAC_{ISO}T$) began 20 min after the start of the CRI. Arterial blood pressure and heart rate were recorded continuously and arterial blood samples for blood gas analysis were collected at the end of the equilibration period. Mean ${\pm}$ SD values for the $MAC_{ISO}B$ and $MAC_{ISO}T$ were $1.33{\pm}0.04%$ and $1.23{\pm}0.04%$, respectively. The $MAC_{ISO}B$ decreased significantly by $7.5{\pm}0.2%$ (P < 0.05) after administration of tramadol. The mean heart rate and arterial blood pressure of six dogs were not changed significantly after tramadol administration. The blood gas levels remained constant during the study. In conclusion, tramadol could significantly reduce $MAC_{ISO}$ without depression of cardiorespiratory function. Thus, the use of tramadol on inhalation anesthesia with isoflurane in dogs can improve the stability of anesthesia and the quality of recovery.

Comparison of Seasonal Concentration of Ammonia and Hydrogen Sulfide in Swine House according to Pig's Growth Stage (돼지 생육 단계에 따른 계절별 암모니아와 황화수소의 돈사 내 농도 비교)

  • Kim, Ki Youn;Ko, Han Jong;Kim, Hyeon Tae
    • Journal of agriculture & life science
    • /
    • v.46 no.2
    • /
    • pp.163-168
    • /
    • 2012
  • The objective of this study is to quantify the levels of ammonia and hydrogen sulfide inmechanically ventilated slurry-pit swine house according to pig's growth stage and seasonal condition. Mean concentrations of ammonia and hydrogen sulfide in the housing room of gestation/farrowing pigs were 5.60 (${\pm}2.48$) ppm and 178.4 (${\pm}204.8$) ppb in spring, 2.51 (${\pm}3.08$) ppm and 86.6 (${\pm}112.5$) ppb in summer, 4.96 (${\pm}2.84$) ppm and 182.3 (${\pm}242.6$) ppb in autumn, and 6.82 (${\pm}3.42$) ppm and 206.3 (${\pm}356.8$) ppb in winter, respectively. Mean concentrations of ammonia and hydrogen sulfide in the housing room of nursery pigs were 7.18 (${\pm}3.26$) ppm and 486.0 (${\pm}190.2$) ppb in spring, 4.23 (${\pm}2.95$) ppm and 206.4 (${\pm}186.9$) ppb in summer, 7.02 (${\pm}2.65$) ppm and 465.4 (${\pm}156.8$) ppb in autumn, and 9.25 (${\pm}3.68$) ppm and 618.4 (${\pm}298.3$) ppb in winter, respectively. Mean concentrations of ammonia and hydrogen sulfide in the housing room of growing/fattening pigs were 9.26 (${\pm}3.02$) ppm and 604.4 (${\pm}186.8$) ppb in spring, 6.78 (${\pm}3.88$) ppm and 312.5 (${\pm}215.4$) ppb in summer, 9.34 (${\pm}2.14$) ppm and 578.2 (${\pm}248.1$) ppb in autumn, and 14.65 (${\pm}3.15$) ppm and 825.3 (${\pm}316.9$) ppb in winter, respectively. As a result, mean concentrations of ammonia and hydrogen sulfide in terms of pig's growth stage were highest in growing/fattening housing room followed by nursery housing room and gestation/farrowing housing room (p<0.05). The swine house showed the highest levels of ammonia and hydrogen sulfide in winter followed by spring, autumn and summer. However, there was no significant difference of ammonia and hydrogen sulfide among seasons (p>0.05).

Recent Progress in Air Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2006 (공기조화, 냉동 분야의 최근 연구 동향: 2006년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwa-Taik;Shin, Dong-Sin;Choi, Chang-Ho;Lee, Dae-Young;Kim, Seo-Young;Kwon, Yong-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.6
    • /
    • pp.427-446
    • /
    • 2008
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2006 has been accomplished. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environments. The conclusions are as follows. (1) The research trends of fluid engineering have been surveyed as groups of general fluid flow, fluid machinery and piping, etc. New research topics include micro heat exchanger and siphon cooling device using nano-fluid. Traditional CFD and flow visualization methods were still popular and widely used in research and development. Studies about diffusers and compressors were performed in fluid machinery. Characteristics of flow and heat transfer and piping optimization were studied in piping systems. (2) The papers on heat transfer have been categorized into heat transfer characteristics, heat exchangers, heat pipes, and two-phase heat transfer. The topics on heat transfer characteristics in general include thermal transport in a cryo-chamber, a LCD panel, a dryer, and heat generating electronics. Heat exchangers investigated include pin-tube type, plate type, ventilation air-to-air type, and heat transfer enhancing tubes. The research on a reversible loop heat pipe, the influence of NCG charging mass on heat transport capacity, and the chilling start-up characteristics in a heat pipe were reported. In two-phase heat transfer area, the studies on frost growth, ice slurry formation and liquid spray cooling were presented. The studies on the boiling of R-290 and the application of carbon nanotubes to enhance boiling were noticeable in this research area. (3) Many studies on refrigeration and air conditioning systems were presented on the practical issues of the performance and reliability enhancement. The air conditioning system with multi indoor units caught attention in several research works. The issues on the refrigerant charge and the control algorithm were treated. The systems with alternative refrigerants were also studied. Carbon dioxide, hydrocarbons and their mixtures were considered and the heat transfer correlations were proposed. (4) Due to high oil prices, energy consumption have been attentioned in mechanical building systems. Research works have been reviewed in this field by grouping into the research on heat and cold sources, air conditioning and cleaning research, ventilation and fire research including tunnel ventilation, and piping system research. The papers involve the promotion of efficient or effective use of energy, which helps to save energy and results in reduced environmental pollution and operating cost. (5) Studies on indoor air quality took a great portion in the field of building environments. Various other subjects such as indoor thermal comfort were also investigated through computer simulation, case study, and field experiment. Studies on energy include not only optimization study and economic analysis of building equipments but also usability of renewable energy in geothermal and solar systems.

Recent Progress in Air Conditioning and Refrigeration Research - A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2002 and 2003 - (공기조화, 냉동 분야의 최근 연구 동향 -2002년 및 2003년 학회지 논문에 대한 종합적 고찰 -)

  • Chung Kwang-Seop;Kim Min Soo;Kim Yongchan;Park Kyoung Kuhn;Park Byung-Yoon;Cho Keumnam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.12
    • /
    • pp.1234-1268
    • /
    • 2004
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 2002 and 2003 has been carried out. Focus has been put on current status of research in the aspect of heating, cooling, air-conditioning, ventilation, sanitation and building environment/design. The conclusions are as follows. (1) Most of fundamental studies on fluid flow were related with heat transportation in diverse facilities. Drop formation and rivulet flow on solid surfaces were interesting topics related with condensation augmentation. Research on micro environment considering flow, heat transfer, humidity was also interesting to promote comfortable living environment. It can be extended considering biological aspects. Development of fans and blowers of high performance and low noise were continuing research topics. Well developed CFD technologies were widely applied for analysis and design of various facilities and their systems. (2) Heat transfer characteristics of enhanced finned tube heat exchangers and heat sinks were extensively investigated. Experimental studies on the boiling heat transfer, vortex generators, fluidized bed heat exchangers, and frosting and defrosting characteristics were also conducted. In addition, the numerical simulations on various heat exchangers were performed and reported to show heat transfer characteristics and performance of the heat exchanger. (3) A review of the recent studies shows that the performance analysis of heat pump have been made by various simulations and experiments. Progresses have been made specifically on the multi-type heat pump systems and other heat pump systems in which exhaust energy is utilized. The performance characteristics of heat pipe have been studied numerically and experimentally, which proves the validity of the developed simulation programs. The effect of various factors on the heat pipe performance has also been examined. Studies of the ice storage system have been focused on the operational characteristics of the system and on the basics of thermal storage materials. Researches into the phase change have been carried out steadily. Several papers deal with the cycle analysis of a few thermodynamic systems which are very useful in the field of air-conditioning and refrigeration. (4) Recent studies on refrigeration and air-conditioning systems have focused on the system performance and efficiency enhancement when new alternative refrigerants are applied. Heat transfer characteristics during evaporation and condensation are investigated for several tube shapes and new alternative refrigerants including natural refrigerants. Efficiency of various compressors and performance of new expansion devices are also dealt with for better design of refrigeration/air conditioning system. In addition to the studies related with thermophysical properties of refrigerant mixtures, studies on new refrigerants are also carried out. It should be noted that the researches on two-phase flow are constantly carried out. (5) A review of the recent studies on absorption refrigeration system indicates that heat and mass transfer enhancement is the key factor in improving the system performance. Various experiments have been carried out and diverse simulation models have been presented. Study on the small scale absorption refrigeration system draws a new attention. Cooling tower was also the research object in the respect of enhancement its efficiency, and performance analysis and optimization was carried out. (6) Based on a review of recent studies on indoor thermal environment and building service systems, it is noticed that research issues have mainly focused on several innovative systems such as personal environmental modules, air-barrier type perimeterless system with UFAC, radiant floor cooling system, etc. New approaches are highlighted for improving indoor environmental conditions and minimizing energy consumption, various activities of building energy management and cost-benefit analysis for economic evaluation.

Monitoring of Working Environment Exposed to Particulate Matter in Greenhouse for Cultivating Flower and Fruit (과수 및 화훼 시설하우스 내 작업자의 미세먼지 노출현황 모니터링)

  • Seo, Hyo-Jae;Kim, Hyo-Cher;Seo, Il-Hwan
    • Journal of Bio-Environment Control
    • /
    • v.31 no.2
    • /
    • pp.79-89
    • /
    • 2022
  • With the wide use of greenhouses, the working hours have been increasing inside the greenhouse for workers. In the closed ventilated greenhouse, the internal environment has less affected to external weather during making a suitable temperature for crop growth. Greenhouse workers are exposed to organic dust including soil dust, pollen, pesticide residues, microorganisms during tillage process, soil grading, fertilizing, and harvesting operations. Therefore, the health status and working environment exposed to workers should be considered inside the greenhouse. It is necessary to secure basic data on particulate matter (PM) concentrations in order to set up dust reduction and health safety plans. To understand the PM concentration of working environment in greenhouse, the PM concnentrations were monitored in the cut-rose and Hallabong greenhouses in terms of PM size, working type, and working period. Compare to no-work (move) period, a significant increase in PM concentration was found during tillage operation in Hallabong greenhouse by 4.94 times on TSP (total suspended particle), 2.71 times on PM-10 (particle size of 10 ㎛ or larger), and 1.53 times on PM-2.5, respectively. During pruning operation in cut-rose greenhouse, TSP concentration was 7.4 times higher and PM-10 concentration was 3.2 times higher than during no-work period. As a result of analysis of PM contribution ratio by particle sizes, it was shown that PM-10 constitute the largest percentage. There was a significant difference in the PM concentration between work and no-work periods, and the concentration of PM during work was significant higher (p < 0.001). It was found that workers were generally exposed to a high level of dust concentration from 2.5 ㎛ to 35.15 ㎛ during tillage operation.

Clinicopathologic features of Acute Interstitial Pneumonia (급성 간질성 폐렴의 임상적 고찰)

  • Shim, Jae-Jeong;Park, Sang-Muyn;Lee, Sang-Hwa;Lee, Jin-Gu;Cho, Jae-Yun;Song, Gwan-Gyu;In, Kwang-Ho;Yoo, Se-Hwa;Kang, Kyung-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.1
    • /
    • pp.58-66
    • /
    • 1995
  • Background: Acute interstitial pneumonia is a relatively rare form of interstitial pneumonia, since the vast majority of interstitial pneumonia have a more chronic course. It corresponds to the lesion described by Hamman and Rich, as Hamman-Rich disease in 1944. Another name in the clinical literature is accelerated interstitial pneumonia, idiopathic acute respiratory distress syndrome (idiopathic ARDS), and the organizing stage of diffuse alveolar damage. Acute interstitial pneumonia differs from chronic interstitial pneumonia by clinical and pathologic features. Clinically, this disease is characterized by a sudden onset and a rapid course, and reversible disease. Method and Purpose: Five cases of pathologically proven acute interstitial pneumonia were retrospectively studied to define the clinical, radiologic, and pathologic features. Results: 1) The five cases ranged in age from 31 to 77 years old. The onset of illness was acute in all patients, it began with viral-like prodrome 6~40 days prior to shortness of breath, and respiratory failure eventually developed in all patients. In 2 cases, generalized skin rash was accompanied with flu-like symptoms. Etiologic agent could not be identified in any case. 2) All patients had leukocytosis and severe hypoxemia. Pulmonary function test of 3 available cases shows restrictive ventilatory defect, and one survived patient(case 5) has a complete improvement of pulmonary function after dismissal. 3) Diffuse bilateral chest infiltrates were present radiologically. Theses were the ground-glass, consolidation, and reticular densities without honeycomb fibrosis in all patients. The pathologic abnormalities were the presence of increased numbers of macrophages and the formation of hyaline membranes within alveolar spaces. There was also interstitial thickening with edema, proliferation of immature fibroblast, and hyperplasia of type II pneumocyte. In the survived patient(case5), pathologic findings were relatively early stage of acute interstitial pneumonia, such as hyaline membrane with mild interstitial fibrosis. 4) Of the 5 patients, four patients died of respiratory failure 14~90 days after onset of first symptom, and one survived and recovered in symptoms, chest X ray, and pulmonary function test Conclusion: These results emphasize that acute interstitial pneumonia is clinically, radiologically, and pathologically distinct form of interstitial pneumonia and should be separated from the group of chronic interstitial pneumonia. Further studies will be needed to evaluate the pathogenesis and the treatment of acute interstitial pneumonia.

  • PDF

Actual Conditions and Perception of Safety Accidents by School Foodservice Employees in Chungbuk (충북지역 학교급식 조리종사원의 안전사고 실태 및 인식)

  • Cho, Hyun A;Lee, Young Eun;Park, Eun Hye
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.43 no.10
    • /
    • pp.1594-1606
    • /
    • 2014
  • The purpose of this study was to examine safety accidents related to school foodservice, working and operating environments of school foodservice, status and awareness of safety education, educational needs, and information on qualitative improvement of school foodservice. The subjects in this study were 234 cooks in charge of cooking at elementary and secondary schools in Chungbuk. A survey was conducted from July 30 to August 8, 2012, and among 202 questionnaires gathered, 194 completed questionnaires were analyzed. Statistical analyses were performed on data utilizing the SPSS version 19.0. The main results of this study were as follows: 44.3% of workers experienced safety accidents. The most frequent safety accident was 'once' (60.5%), and most safety accidents took place between June and August (31.4%). The time at which most safety accidents happened was between 8 and 11 am. Most safety accidents happened during cooking (52.3%) and while using a soup pot or frying pot (52.4%). The most common accidents were 'burns', 'wrist and arm pain', and 'slips and falls'. Respondents who experienced safety accidents replied that 57.6% of employees dealt with injuries at their own expense, and only 35.3% utilized industrial accident insurance. In terms of the operating environment, the score for 'offering information and application' was highest (3.76 points), whereas that for 'security of budget' was lowest (1.77 points). As for accident education, employees received safety education approximately 3.45 times and 5.10 hours per year. Improving the working environment of school foodservice cooks requires administrative and financial support. Furthermore, educational materials and guidelines based on the working environment and safety accident status of school foodservice cooks are required in order to minimize potential risk factors and control safety accidents in school foodservice.

Clinical Analysis of Acute Respiratory Tract Infections by Influenza Virus in Children (인플루엔자 바이러스에 의한 소아 급성 호흡기 감염증의 유행 및 임상 양상)

  • Kwon, Min Kyoung;Kim, Mi Ran;Park, Eun Young;Lee, Kon Hee;Yoon, Hae Sun;Kim, Kwang Nam;Lee, Kyu Man
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.12
    • /
    • pp.1519-1527
    • /
    • 2002
  • Purpose : Although influenza virus is one of the most important causes of acute respiratory tract infections(ARTIs) in children, virus isolation is not popular and there are only a few clinical studies on influenza in Korea. We evaluated the epidemiologic and clinical features of ARTIs by influenza virus in children. Methods : From February 1995 to August 2001, nasopharyngeal aspirations were obtained and cultured for the isolation of influenza virus in children admitted with ARTIs. The medical records of patients with influenza virus infection were reviewed retrospectively. Results : Respiratory viruses were isolated in 997(22.0%) out of 4,533 patients examined, and influenza virus was isolated in 164 cases(3.6%). Influenza virus was isolated year after year mainly from December to April of next year. The ratio of male and female was 1.9 : 1 with a median age of 15 months. The most common clinical diagnosis of influenza virus infection was pneumonia, and fever and cough developed in most patients. There was no difference between influenza A and B infection in clinical diagnoses and symptoms. All patients recovered without receiving antiviral treatment except for one patient diagnosed with pneumonia who had underlying disease of Down syndrome with ventricular septal defect. Conclusion : ARTIs caused by influenza virus developed every winter and spring during the period of study. Because fatal complication can develop in the high risk group, prevention, early diagnosis and proper management of influenza should be emphasized.

Comparative analysis of status of safety accidents and importance-performance analysis (IPA) about precautions of safety accidents by employment type of industry foodservices in Jeonbuk area (전북지역 산업체급식소 조리종사자의 고용형태에 따른 안전사고 실태 및 안전사고 예방관리에 대한 중요도와 수행도 분석)

  • So, Hee;Rho, Jeong Ok
    • Journal of Nutrition and Health
    • /
    • v.50 no.4
    • /
    • pp.402-414
    • /
    • 2017
  • Purpose: The purpose of the study was to evaluate the status of safety accidents and importance-performance analysis (IPA) between regular and non-regular employees in industry foodservices. Methods: The participants were regular employees (n = 119) and non-regular employees (n = 163) in industry foodservices in the Jeonbuk area. Demographic characteristics, status of safety accidents, safety education, and importance and performance status were assessed using a self-administered questionnaire. Results: Approximately 66.4% of regular employees and 53.4% of non-regular employees experienced safety accidents (p < 0.05). Types of safety accidents of regular and non-regular employees were mostly burns, and causes were mostly from their own negligence. Approximately 98.3% of regular employees and 95.1% of non-regular employees experienced safety education. Approximately 88.9% of regular employees and 96.8% of non-regular employees received safety education from dietitians. Approximately 41.9% of regular employees and 50.0% of non-regular employees had difficulty applying the contents of safety education due to lack of time during work. As a result of IPA, regular and non-regular employees were aware of the importance of the following and performed them well: 'Clean the floor of the work place', 'Arrange in the work area', 'Wear safety shoes', 'Check for heater cord', and 'Safety cooking when using oil'. On the other hand, they were not aware of the importance of the following and performed them insufficiently: 'Check for the MSDS', 'Aware of chemical signs', 'Wear protection gloves etc.', 'Do stretching exercise', and 'Using ancillary tools'. Conclusion: Therefore, it is necessary to improve the consciousness of dietitians for effective application of safety education contents, development of contents, especially MSDS, and related things.