• 제목/요약/키워드: 급탕부하

검색결과 24건 처리시간 0.032초

지역난방 동절기 공동주택 온수급탕부하의 LS-SVM 기반 모델링 (LS-SVM Based Modeling of Winter Time Apartment Hot Water Supply Load in District Heating System)

  • 박영칠
    • 설비공학논문집
    • /
    • 제28권9호
    • /
    • pp.355-360
    • /
    • 2016
  • Continuing to the modeling of heating load, this paper, as the second part of consecutive works, presents LS-SVM (least square support vector machine) based model of winter time apartment hot water supply load in a district heating system, so as to be used in prediction of heating energy usage. Similar, but more severely, to heating load, hot water supply load varies in highly nonlinear manner. Such nonlinearity makes analytical model of it hardly exist in the literatures. LS-SVM is known as a good modeling tool for the system, especially for the nonlinear system depended by many independent factors. We collect 26,208 data of hot water supply load over a 13-week period in winter time, from 12 heat exchangers in seven different apartments. Then part of the collected data were used to construct LS-SVM based model and the rest of those were used to test the formed model accuracy. In modeling, we first constructed the model of district heating system's hot water supply load, using the unit heating area's hot water supply load of seven apartments. Such model will be used to estimate the total hot water supply load of which the district heating system needs to provide. Then the individual apartment hot water supply load model is also formed, which can be used to predict and to control the energy consumption of the individual apartment. The results obtained show that the total hot water supply load, which will be provided by the district heating system in winter time, can be predicted within 10% in MAPE (mean absolute percentage error). Also the individual apartment models can predict the individual apartment energy consumption for hot water supply load within 10% ~ 20% in MAPE.

축열식전기온돌 공급시간 자동제어시스템 개발 (Development of Automatic Control System for Midnight Electric Ondol)

  • 박석인;정봉만;유승원
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 2002년도 춘계 학술발표회 논문집
    • /
    • pp.29-33
    • /
    • 2002
  • 최근 전력부하 평준화를 통한 경영효율 증진을 위하여 난방 및 급탕에 사용되는 심야전력기기 보급을 정책적으로 적극 추진하고 있다. 현재 한전에서는 심야전력공급개시시간인 22:00부터 익일 08:00까지 심야전력을 공급하고 있으나 전국의 모든 심야전력기기가 22:00에 동시에 가동됨에 따라 한시간이 경과한 23:00에 심야전력 부하가 최대에 이르고 있으며, 이에 따라 심야전력기기에 의한 전력피크 발생 우려가 현실로 나타나고 있다.(중략)

  • PDF

빙축열 및 히트펌프시스템 전문회사 '그들에게는 뭔가 특별한 것이 있다.'

  • 에너지절약전문기업협회
    • ESCO지
    • /
    • 통권23호
    • /
    • pp.28-29
    • /
    • 2003
  • 폐열을 이용한 히트펌프시스템은 에너지절감효과는 냉방시 $45\%$, 난방시 $75\%$, 급탕부하시 $67\%$정도이어서 가히 타의추종을 불허한다. 한국적 상황을 고려한 국내 최초의 폐열이용 히트펌프시스템이 될 이 사업의 투자비회수기간은 2.5년에 불과해 향후 휴양 및 숙박시설 등지에 큰 관심을 끌 것으로 최사장은 기대하고 있다.

  • PDF

태양열 집열기 성능실험을 통한 공동주택 효율적 설치방안 연구 (A Study on the Effective Installation to the Apartment Through Solar Collector Performance Test)

  • 김미연;최병도;김형근;박진철
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.480-487
    • /
    • 2012
  • The application of solar energy in residential building is general and natural in today. And application methods of solar thermal energy is divided in two kind of form, single evacuated tube and flat-plate form. Then in this study, the efficiency of single evacuated tube and flat-plate system is compared by total and effective area considering the time receiving the solar radiation between 24 hours and the specific time(10:00~15:00). As a result of the experiment, single evacuated tube and flat-plate collector's efficiency is varied by the quantity of solar radiation. And especially, the flat-plate system is more affected by outdoor temperature. Therefore the application of solar thermal system should be considered the solar radiation and outdoor temperature.

  • PDF

6 kW급 태양열 온수급탕 시스템의 실증실험 및 분석(제2보 모델링 및 시뮬레이션) (Verification Experiment and Analysis for 6 kW Solar Water Heating System(Part 2 : Modelling and Simulation))

  • 최봉수;김진홍;강용태;홍희기
    • 설비공학논문집
    • /
    • 제16권6호
    • /
    • pp.556-565
    • /
    • 2004
  • We have experimented an actual solar water heating system acquiring real data for one year period. On the basis of the operation data, it is necessary to predict the system performance such as collector efficiency and solar fraction, and to analyze the economical efficiency for system optimal design. To estimate the performance of actual systems through simulation, valid modelling for components consisting of the system should be accompanied. The present study is focused on the modelling for load patterns and operating control conditions. We proposed two load models: concentration model which gathers real loads as a meaningful group and distribution model which disperses real loads with time. If grouping of the load distribution is suitable, the predicted values by the concentration model approaches to those by the distribution model close to actual load pattern apparently. As a result, both of them are in good agreement with those by experiment.

공동주택용 태양열원 급탕시스템의 운전성능 연구 (A Study on the Operating Performance of Solar Assisted Hot Water System for Apartment Houses)

  • 이윤규;황인주
    • 설비공학논문집
    • /
    • 제15권11호
    • /
    • pp.928-936
    • /
    • 2003
  • In the present study, feasibility investigation on the solar assisted hot water supply system for apartment houses was carried out by the review of service facility and heat load pattern. Also analysis and experiment of the small sized system model were performed. This hybrid system are consists of solar collector, heat storage tank, controller, and gas boiler using LPG as a secondary heat source. The analytical results showed a good agreement with experimental data. We found that this hybrid system could reduce the energy cost by 30% for hot water compared to typical boiler system in the apartment houses. Also we showed that this model could be used for the energy and economic analysis of the hybrid system.

흡수식을 이용한 에너지 장거리 수송/변환 기술

  • 강용태
    • 대한설비공학회지:설비저널
    • /
    • 제33권3호
    • /
    • pp.11-18
    • /
    • 2004
  • 흡수식 사이클을 이용한 에너지의 장거리수송 기술을 소개하고 경제성평가 결과를 제시한다. 현재 에너지수요 측면에서 가장 높은 증가율을 보이고 있는 것이 바로 대도시 및 산업단지의 냉$.$난방 및 급탕용 에너지이다. 냉$.$난방에 사용되는 에너지는 10$0^{\circ}C$미만의 저온으로서 고열원 에너지인 화석연료의 사용은 에너지사용 면에서 비효율적이다. 따라서 산업지 역에서 버려지는 폐열원등의 각종 미활용에너지를 이용하여 냉$.$난방부하를 충족시킬 수 있는 에너지 절약형 시스템의 개발이 매우 중요한 과제로 대두되고 있다. 일반적으로 미활용에너지 및 폐열에너지 공급지역은 소비지역으로부터 멀리 떨어져 있다. 지금까지 흡수식시스템은 냉동 및 냉방의 개념에서 기술개발 및 실용적운전이 이루어져 왔으나, 본 논문에서는 흡수식시스템을 이용한 에너지의 장거리수송 및 변환 기술을 소개하고자 한다.

  • PDF

봄철 태양열 하이브리드 시스템의 부하조건 변화에 따른 운전특성 연구 (Study on the Operating Characteristics with Load Condition in Hybrid Solar Heating System during Spring Season)

  • 표종현;김원석;조홍현;류남진
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1418-1423
    • /
    • 2009
  • This study describes experimental study on the performance characteristics with load condition in hybrid solar heating system during spring season. The room temperatures, the hot water conditions and the lower part temperatures of heat storage tank were changed to analyze the system performances. As a results, the hot water was significantly affected by the ambient temperature. The indoor setting temperature affected the solar fraction. When the low part temperature of the storage tank increased, the temperature of the hot water rose and the temperature of the hot water in morning was affected by the ambient temperature.

  • PDF

ZEB 활성화를 위한 부하기준 산정 방법 연구 (A Study on the Calculation Method of Load standard for ZEB activation)

  • 이항주;김인수
    • 에너지공학
    • /
    • 제26권4호
    • /
    • pp.92-99
    • /
    • 2017
  • 국내에서는 국토부 7대 신산업, 산업부 8대 신산업으로 제로에너지빌딩이 지정되었으며, 건물외피의 단열성능 극대화와 건물 기기 효율향상 및 신재생 보급 확대를 위해 부처간 융합을 통해 제로에너지빌딩 보급 활성화 달성을 목표로 하고 있다. 국내에서 시행 중인 제로에너지빌딩 인증제에 해당되는 건물에너지효율등급 1++이상이 되는 건축물들의 부하(냉방, 난방, 급탕, 조명, 환기)들의 에너지소요량을 분석하여 대략적인 부하들의 수준을 파악하고 제로에너지빌딩 인증제 고도화를 위한 기초 자료로 활용될 수 있도록 하는 목적이 있다. 제로에너지빌딩 인증에 해당되는 건축물은 2017년 기준 61개 가량 되는 것으로 파악되고 있으며, 패시브 측면과 액티브 측면을 고려하여 5대 부하별 대략적인 기준 값과 1차 에너지소요량을 산정하였다. 부하기준 산정을 위한 데이터의 표본이 적어 명확한 기준이 된다고 보기는 어려우나 앞으로 제로에너지빌딩 인증 기준을 고도화하기 위해 다양한 방법들을 적용하여 해석할 필요성이 있다고 판단된다.