• Title/Summary/Keyword: 급수공급계통

Search Result 7, Processing Time 0.024 seconds

Development of Engineering Program for APR1400 Feedwater Supplying System (APR1400 급수공급계통 엔지니어링 프로그램 개발)

  • Yeom, Dong Un;Ju, Tae Young;Hyun, Jin Woo
    • Journal of Energy Engineering
    • /
    • v.26 no.2
    • /
    • pp.12-22
    • /
    • 2017
  • Korea Hydro & Nuclear Power Co. (KHNP) has implemented engineering programs for operating nuclear power plants. Engineering programs are maintenance rule (MR), functional importance determination (FID), single point vulnerability (SPV) and functional equipment group (FEG). Recently, KHNP has developed engineering programs for APR1400 feedwater supplying system to establish the advanced engineering system and will verify the suitability of engineering programs through implementing in new nuclear power plant. Consequently, it is expected that the reliability of APR1400 feedwater supplying system will be improved by implementing engineering programs.

월성 2,3,4호기 비상급수계통 성능평가에 관한 연구

  • 오광석;김창호;이중섭;김선철;오종필
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.362-367
    • /
    • 1996
  • CANDU-6형 원자력발전소인 월성 2,3,4호기 비상급수계통의 성능을 평가하기 위하여 설계기능 수행과 관련된 변수로서 격납건물내 집수조(sump) 온도와 열수송계통으로 주입되는 냉각재온도를 사용한 분석을 수행하였다. 이 온도들은 NTU(Number of Transfer Unit)방법을 이용한 비상노심 냉각계통 열교환기의 열전달속도와 열전달계수의 해석을 열평형관계식과 함께 조합한 프로그램을 사용하여 계산하였다. 또한 증기발생기 급수량과 추후 수조에 공급되는 보충수에 대한 설계요건을 검토하였다. 이러한 변수와 설계요건은 비상급수계통이 발전소 정상 열제거기능 상실후 노심의 붕괴열제거에 유효한 열침원으로서의 기능을 수행함을 보여 주었다. 또 격납건물의 건전성 유지와 관련된 집수조내 최고온도가 허용치 이하로 유지되었다.

  • PDF

Mid-loop 운전중 RHR 기능 상실사고시 최대압력 및 보조급수 공급 여유시간 분석

  • 김원석;정영종;장원표
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.473-480
    • /
    • 1996
  • 영광 3/4호기 mid-loop 운전중 잔열제거(RHR) 기능 상실사고시 열수력적 현상을 최적 전산코드인 CATHARE2를 이용하여 해석하였다. 이러한 사고시 열수력적 현상은 일,이차측 냉각재 방출유로와 계통내 비응축성 가스의 거동에 의해 크게 영향을 받는다. 본 연구에서는 2개의 경우를 모의하였는데, 하나는 계통내 방출유로가 있는 경우이며 다른 하나는 방출유로가 없는 경우를 계산하였다. 이 때 사용된 가정은 다음과 같다. (가) 계통은 부분충수 운전 상태로 상부에 비응축성 가스나 증기로 가득 차 있다. (나) 증기발생기는 1대만이 이용 가능하고 이차측은 습식보관 상태이며, 보조급수는 공급되지 않고 이차측 압력은 대기압 상태이다 (다) 사고는 원자로 정지후 2일후 발생한다. 이와같은 조건하에서 사고시 계통 최대압력은 방출유로가 있는 경우 사고후 6,000 초에 0.27 MPa이며, 방출유로를 통한 유량은 총 2.4 kg/s이다. 이 방출유량을 외삽하여 계통수위가 고온관 바닦까지 도달하는데 걸린 시간은 사고후 약 5.67시간이다. 증기발생기 U-튜브를 통한 열전달에 의해 이차측 증기 발생으로 이차측 수위가 하락하면 증기발생기 reflux cooling은 제한을 받을 수 있다. 이 경우 이차측 수위가 U-튜브의 active 영역 상부까지 도달하는데 걸리는 시간은 사고후 약 10시간으로 계산되었다. 그러므로 이 경우 보조급수 공급 여유시간보다 노심 노출시간이 더 빨리 도달하여 노심을 손상시킨다. 사고시 수위지시계는 계통감압에 큰 영향을 주지 못하기 때문에 가능한 빨리 닫아 계통 inventory를 유지하는 것이 이차측 보조급수공급보다 우선한다.합한 설계방안으로 분석되었다.크다는 단점이 있다.TEX>$_2$O$_3$ 흡착제 제조시 TiO$_2$ 함량에 따른 Co$^{2+}$ 흡착량과 25$0^{\circ}C$의 고온에서 ZrO$_2$$Al_2$O$_3$의 표면에 생성된 코발트 화합물을 XPS와 EPMA로 부터 확인하였다.인을 명시적으로 설명할 수 있다. 둘째, 오류의 시발점을 정확히 포착하여 동기가 분명한 수정대책을 강구할 수 있다. 셋째, 음운 과 정의 분석 모델은 새로운 언어 학습시에 관련된 언어 상호간의 구조적 마찰을 설명해 줄 수 있다. 넷째, 불규칙적이며 종잡기 힘들고 단편적인 것으로만 보이던 중간언어도 일정한 체계 속에서 변화한다는 사실을 알 수 있다. 다섯째, 종전의 오류 분석에서는 지나치게 모국어의 영향만 강조하고 다른 요인들에 대해서는 다분히 추상적인 언급으로 끝났지만 이 분석을 통 해서 배경어, 목표어, 특히 중간규칙의 역할이 괄목할 만한 것임을 가시적으로 관찰할 수 있 다. 이와 같은 오류분석 방법은 학습자의 모국어 및 관련 외국어의 음운규칙만 알면 어느 학습대상 외국어에라도 적용할 수 있는 보편성을 지니는 것으로 사료된다.없다. 그렇다면 겹의문사를 [-wh]의리를 지 닌 의문사의 병렬로 분석할 수 없다. 예를 들어 누구누구를 [주구-이-ν가] [누구누구-이- ν가]로부터 생성되었다고 볼 수 없다. 그러므로 [-wh] 겹의문사는 복수 의미를 지닐 수 없 다. 그러면 단수 의미는 어떻게 생성되는가\

  • PDF

Analysis of Loss of HVAC for Nuclear Power Plant (원전의 공기조화설비(HVAC) 상실사고 분석방법)

  • Song, Dong-Soo
    • Journal of Energy Engineering
    • /
    • v.23 no.1
    • /
    • pp.90-94
    • /
    • 2014
  • Environmental qualification (EQ) for safety-related equipment is required to ensure that those equipment will perform their required function even under the harsh environment conditions arising from design basis accident in the nuclear power plant. As a part of EQ program, the room temperature analysis in case of a loss of Heating, Ventilation, and Air Conditioning(HVAC) system was carried out to ensure the operability of the safety-related equipment of a nuclear power plant randomly chosen among the Korean nuclear power plants. In this paper, this analysis was performed in the conservative perspective using GOTHIC code. The room temperature analysis includes selecting the rooms in which the safety related equipment are located but not supported by safety related HVAC and determining the temperature of the selected rooms. Target rooms for the analysis consist of W229/W237 (Aux. feedwater pump room), W232 (Aux. feedwater tank room) and W230 (Equipment passageway). The results showed the temperature range from $43^{\circ}C$ to $83^{\circ}C$, in 72 hours after a loss of HVAC. Those values are far below of generic EQ temperature($171^{\circ}C$). Therefore, it is satisfied with EQ requirement of temperature limits on safety related equipment.

Installation Design of Landscape-use Artificial Channel for Sustainable Management -Focusing on the Water Volume and Equipment System of Streamlet in Jeonju and Wanju Innovation City- (계류형 수경시설의 지속가능한 운영·관리를 위한 설치방안 - 전주·완주 혁신도시 실개천 용량과 설비계통을 중심으로 -)

  • Oh, Chang-Song
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.49 no.2
    • /
    • pp.113-127
    • /
    • 2021
  • Although planning techniques linking parks, green areas, and waterways have become common, there are frequent disruptions in the operation and management of landscape-use artificial channels (LuAC). Therefore, this study examined a design to promote the sustainable management and operation of a LuAC using rainwater for the streamlets of the Jeonju-Wanju Innovative City. In order to accomplish the purpose of this study, scenarios were set up by dividing the design into waterhead and waterway portions. First, the scenario regarding the waterhead was analyzed to calculate the water supply and storage required for the waterway and waterhead. The analysis showed that the waterway requires a water supply of 676.8 tons/months, 3,018 tons to 5,512 tons of storage space, and a water depth of 0.75 m to 1.37 m considering the ecological and landscape aspects. The second scenario is to select an effective system of facilities for the operation and management of the LuAC. To accomplish this, a single-circulation system (SCS), which transports water to a highland location was compared to a multi-circulation system (MCS), which supplied water separately to each water space and operated independently. The results showed that the MCS, which was operated independently by small power units, was more effective owing to the vast difference in water supply operation times.

Development of Optimal Network Model for Conjunctive Operation of Water Supply System with Multiple Sources (다수원 상수도시스템 연계운영을 위한 최적 네트워크 모형 구축)

  • Ryu, Tae-Sang;Ha, Sung-Ryong;Cheong, Tae-Sung
    • Journal of Korea Water Resources Association
    • /
    • v.44 no.12
    • /
    • pp.1001-1013
    • /
    • 2011
  • Development of an optimal water supply system considering water quantity, quality, and economical efficiency is needed to decide optimal available area by combine water supply systems in overlapped area where are more than 2 water sources. The EPAnet and the KModSim were coupled to develop optimal network model. The developed network model was calibrated by measured data from water supply system in Geoje City, Korea in 2007 which have three water sources such as Sadeong booster pumping station, Guchun dam reservoir and Yoncho dam reservoir. The optimum network model was validated by operating results of 2011 to assess the economically optimized service area and optimal pump combination under the given hydraulic operating rules developed in this study. The developed model can be applied into designing water supply systems and operating rules for the conjunctive operation since the model can give the optimal solution satisfied with water quantity, economical efficiency and quality.

Analysis of water quality smart meter data using dynamic time warping (Dynamic Time Warping을 이용한 수질 스마트미터 데이터 분석)

  • Lim, Soyeon;Jung, Donghwi
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.173-173
    • /
    • 2021
  • 현재까지 상수도관망 내 수질적 거동에 대한 분석은 (1) 네트워크 수질 모델(EPANET 수질모의 등)에 기반한 방법과 (2) 시공간적 저해상도 데이터에 기반한 데이터 분석법이 주를 이루었다. 그러나 현존 네트워크 수질 모델은 수질 사고의 복잡한 물리·화학적 거동을 상세히 모의하기 어렵다. 반면 계측 및 통신기술의 발달로 고해상도 수질 데이터의 실시간 수집이 가능해지면서 사고의 사전감지, 발생시 즉각적 탐지 및 대응을 위한 데이터 분석법에 관심이 증가하고 있다. 서울 문래동, 인천, 포항의 경우에서도 알 수 있듯이, 수질사고 발생 시 원인물질의 시공간적 이송 또는 전파에 대한 정보는 사고대응에 유용하게 활용된다. 본 연구는, 비정상적인 수질변화의 계통 내 전달 시간을 계산하기 위해 고해상도 수질 스마트 미터 데이터에 기반한 데이터 분석법을 개발하였다. 물공급 하류방향의 수질변화 전달 시간 정량화를 위해 화음탐색법 기반 동적시간워핑(Dynamic time warping; DTW) 기술을 이용하였고, 원데이터의 전처리를 위해 이동평균필터링을 수행하였다. 개발된 분석법은 A시 생산 및 배·급수과정의 감시지점에서 10초 단위로 계측된 다양한 수질변수(pH, 탁도, 잔류염소, 전기전도도, 수온 등)의 공간적 변이 전파시간을 결정하기 위해 적용되었다. 분석에 활용한 데이터는 데이터 통신 및 측정 기기에 의한 이상값과 운영상황의 변화에 따라 변동한 값을 처리하기 이전의 데이터이다. 데이터 품질에 의한 영향을 배제하기 위해 이상값이 발생하지 않은 기간을 파악한 후, 그 기간에 대하여 분석하였다. 계통 내 위계에 따라 두 지점의 측정값의 전파시간을 정량화한 결과, 지점에 따라 전파시간이 다르게 나타났다. 또한, 같은 두 지점에 적용한 결과라도 DTW를 적용하는 기간과 이동평균필터링의 크기에 따라 수질변화 전달 시간이 다르게 나타나는 것을 확인할 수 있었다. 본 연구에서 개발된 분석법은 다변량 수질변수 간의 영향관계를 파악하는데 확장 적용이 가능하다. 또한, 이 방법의 실시간 적용을 통해 동적으로 변화하는 전달시간을 주기적, 공간적으로 갱신하여 관망 수질 변화 모니터링이 가능하다.