• Title/Summary/Keyword: 급내 상관계수법

Search Result 7, Processing Time 0.029 seconds

Development of The New Instrument for Measuring of Trunk-Hip Forward Flexion (새로운 체전굴 측정 방법의 개발)

  • Lee, Gun-Bum
    • Korean Journal of Applied Biomechanics
    • /
    • v.12 no.2
    • /
    • pp.245-257
    • /
    • 2002
  • The purpose of this study was to develop a simple, valid, and reliable instrument for measuring forward flexion of trunk-hip joint. The subject included 44 females for sports major of volunteers at D. Women's University. In establishing the validity, objectivity the reliability of the new flexibility test(NF-test) for trunk-hip joint, Takei- flexometer(modified Leighton flexometer) was administered as the reference instrument, and test-retest method was utilized with the best scores. Intraclass correlation coefficient was obtained to use two way-mixed effect model and this value was average measure. The Pearson product correlation coefficient of L in this study were; the new flexibility test and Takei-flexometer as the reference tool correlated r = .962 in the first test, r = .960 in the second test. The intraclass correlation coefficient of the new flexibility test between in the initial test and in the retest were R = .994 for L, R =.993 for Y, and the intraclass correlation coefficient of the new flexibility test between L and Y were R =.985 in the initial test, and R =.986 in the retest. Based on the above findings, the following conclusions are presented. It was found the new flexibility test (NF test) was a valid, reliable, objective tool for measuring forward flexion of trunk-hip joint, and possible to be recommended as he test for measuring trunk-hip flexibility in the field.

Accuracy of dental model based on the state-of-the-art manufacturing technique (첨단 제조기술 기반으로 제작된 치과용 모형의 정확도에 관한 연구)

  • Kim, Jae-Hong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.11
    • /
    • pp.693-700
    • /
    • 2020
  • This study compared the accuracy and reliability of definitive casts fabricated from a digital impression and conventional impression technique. A master model with the prepared upper full-arch tooth was used. Samples of ten plaster models and ten polyurethane models were duplicated using a selected standard master model. Six linear measurements were recorded between the landmarks, directly on each of the stone models and the polyurethane models on two occasions by a double examiner. The Wilcoxon signed-rank test, interclass correlation coefficient (ICC), measurement error (MSE), and limit of agreement (LoA) were used for statistical analysis. The ICC ranged from 0.76 to 0.99 when comparing the stone models and polyurethane models. The mean difference between the stone models and polyurethane models ranged from 0.09mm to 0.20mm, suggesting that stone models might be slightly larger than polyurethane models. Based on this study, the accuracy of the polyurethane models in evaluating the performance of an oral scanner and subtractive technology was acceptable. Further studies will be needed on patient subjects under clinical conditions that may involve missing or malpositioned teeth and fixed dental prostheses because this study was limited to use a standard master model and duplicated sample models in a laboratory setting.

A Short form of the Gray-Wheelwright Test (단축형 그레이-휠라이트 검사)

  • Ju-Kab Lee;Sung-Hyun Kim;Yong-Wook Shin
    • Sim-seong Yeon-gu
    • /
    • v.33 no.1
    • /
    • pp.61-80
    • /
    • 2018
  • We investigated whether the 81 items of the Gray-Wheelwright test correctly measure the concept of Jung's typology and aimed to refine the test. Participants (n=431) completed the Gray-Wheelwright test, and the results were analyzed using factor analysis with the varimax rotation and the maximum likelihood extraction method. A pair of opposing attitudes, introversion/extroversion, or one of the two pairs of opposing functional types, thinking/feeling or intuition/sensation, was labeled to the extracted factor according to the majority type of the items in the factor. The minority items or items not included in any factors were excluded from making a short form of the Gray-Wheelwright test with 45 items. We used intraclass correlation (ICC) coefficient and Cronbach's alpha for the test-retest reliability and internal consistency of the test, respectively. The newly developed short form of the Gray-Wheelwright test measured the Jung's personality types well, which was comparable to the original one while reducing time and effort required for the testing.

Comparison of Batch Assay and Random Assay Using Automatic Dispenser in Radioimmunoassay (핵의학 체외 검사에서 자동분주기를 이용한 Random Assay 가능성평가)

  • Moon, Seung-Hwan;Lee, Ho-Young;Shin, Sun-Young;Min, Gyeong-Sun;Lee, Hyun-Joo;Jang, Su-Jin;Kang, Ji-Yeon;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.4
    • /
    • pp.323-329
    • /
    • 2009
  • Purpose: Radioimmunoassay (RIA) was usually performed by the batch assay. To improve the efficiency of RIA without increase of the cost and time, random assay could be a choice. We investigated the possibility of the random assay using automatic dispenser by assessing the agreement between batch assay and random assay. Materials and Methods: The experiments were performed with four items; Triiodothyronine (T3), free thyroxine (fT4), Prostate specific antigen (PSA), Carcinoembryonic antigen (CEA). In each item, the sera of twenty patients, the standard, and the control samples were used. The measurements were done 4 times with 3 hour time intervals by random assay and batch assay. The coefficient of variation (CV) of the standard samples and patients' data in T3, fT4, PSA, and CEA were assessed. ICC (Intraclass correlation coefficient) and coefficient of correlation were measured to assessing the agreement between two methods. Results: The CVs (%) of T3, fT4, PSA, and CEA measured by batch assay were 3.2$\pm$1.7%, 3.9$\pm$2.1%, 7.1$\pm$6.2%, 11.2$\pm$7.2%. The CVs by random assay were 2.1$\pm$1.7%, 4.8$\pm$3.1%, 3.6$\pm$4.8%, and 7.4$\pm$6.2%. The ICC between the batch assay and random assay were 0.9968 (T3), 0.9973 (fT4), 0.9996 (PSA), and 0.9901 (CEA). The coefficient of correlation between the batch assay and random assay were 0.9924(T3), 0.9974 (fT4), 0.9994 (PSA), and 0.9989 (CEA) (p<0.05). Conclusion: The results of random assay showed strong agreement with the batch assay in a day. These results suggest that random assay using automatic dispenser could be used in radioimmunoassay.

The Study About Intra-Familial Transmission of the Neurological Soft Signs in Schizophrenia (정신분열병에서 연성 신경학적 징후의 가족내 전달에 관한 연구)

  • Yoo, Sujung;Choi, Yongrak;Lee, Sangick;Shin, Chuljin;Kim, Siekyeong;Son, Jungwoo
    • Korean Journal of Biological Psychiatry
    • /
    • v.15 no.2
    • /
    • pp.83-91
    • /
    • 2008
  • Objectives : Neurological soft signs have been regarded as endophenotypes associated with the genetic basis of schizophrenia. This study was to investigate the intra-familial correlations of the neurological soft signs according to their genetic loading. Methods : Schizophrenic patients(N=14) were included, who had one parent with a family history of schizophrenia and the other without it. Genetic loading was determined by the patient's family history of schizophrenia using the Family Interview for Genetic Studies(FIGS). These parents were subdivided into two groups. The first group was designated as 'presumed carriers'(N=9) of genetic loading, who had one or more schizophreic firstor second-degree relatives. The second group was designated as 'presumed non-carriers'(N=11) of genetic loading, who had no schizophrenic first- or second-degree relatives. Normal controls(N=12) consisted of people without schizophrenic relatives. NSS were evaluated using the Neurological Evaluation Scale-Korean Version (NES-K), and the intra-familial correlations of NSS were tested using the Intra-Class Coefficients(ICC) method. Results : The scores of Motor Coordination subdimension of NES-K were significantly correlated between the patients and their presumed carriers(ICC=.804, p=.016), but not significantly correlated between the patients and their presumed noncarriers. In other subdimensions of NES-K, no significant correlation were found between the patients and their parents regardless of the genetic loading. But, there were no statistically significant differences in the scores of Motor Coordination subdimension of NES-K between the patients and controls. Conclusion : This study did not prove that the neurological soft signs might be an endophenotype of schizophrenia that cosegregate with the genetic loading. The future study using more subjects than this would be needed.

  • PDF

Surface Topographic Measurement Method for Assessing Lower Extremity Alignment: Examination on a novel clinical and research Tool (하지 정렬 평가를 위한 체표면 토포그래피를 이용한 측정법: 새로운 임상 및 연구 도구에 대한 검토)

  • Yim, Ji-Young;Yim, Hyun-Seung;Park, Dae-Sung;Lee, Na-Kyung;Lee, Na-Kyung
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.10 no.1
    • /
    • pp.37-45
    • /
    • 2016
  • The purpose of this study was to assess the intra-rater, inter-rater and test-retest reliability and validity of frontal plane lower extremity alignment estimated from a rasterstereographic method using ABW-Mapper. Eighteen subjects participated in this study. The S angle (stereographic angle-frontal plane lower extremity alignment estimated from a rasterstereographic method) in standing was measured throughout the two sessions with one week interval by two different readers. In the first session, a reader measured S angle twice per subject with a short break in-between. The Q-angle (quadriceps angle) was measured using a standard goniometer from a photography taken through digital camera with the participant standing in the same position as in the S angle measurement. The HKA(hip-knee-ankle) angle was measured from a computer based digital radiograph with the computerized measurement software. Reliability was tested using intraclass correlation coefficients(ICC). Validity was tested using a Pearson's correlation coefficient. Excellent intra-rater(ICC=0.956~0.974), inter-rater(ICC=0.962), test-retest reliability (ICC=0.945) were demonstrated. There were strong negative correlations between S angle and Q-angle (r=-0.739), and between S angle and HKA angle (r=-0.702). Therefore, the S angle measured using a rasterstereographic mapper may be used to as a preliminary or supplementary tool to evaluate and study LE alignment in the frontal plane in relation to HKA angle or Q-angle.

Assessment of children with developmental delay: Korean infant and child development test (KICDT) and Korean Bayley scale of infant development-II (K-BSID-II) (발달 지연아에서 한국형 영유아 발달 검사와 베일리 영유아 발달 검사의 비교 분석)

  • Kim, Ji-Hoon;Yum, Mi-Sun;Jeong, Soo-Jin;Ko, Tae-Sung
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.7
    • /
    • pp.772-777
    • /
    • 2009
  • Purpose : We aimed to compare the effectiveness of 2 developmental tests-Korean Infant and Child Development Test (KICDT) and Korean Bayley Scale of Infant Development-II (K-BSID-II)-in the assessment of children with developmental delay. Methods : Twenty-eight children with suspected developmental delay, who visited the Department of Pediatrics in Asan Medical Center from February 2007 to June 2008 were enrolled. They were examined using both KICDT and K-BSID-II. The results of the tests were compared on the basis of 2 parameters: age group of the children and detection of organic brain lesion on magnetic resonance imaging (MRI). The correlation between the results of the 2 tests was analyzed using SPSS. Further, intraclass correlation coefficient was calculated using SAS to examine consistency between the results of the 2 tests. Results : The mental developmental index of K-BSID-II showed significant correlation with every KICDT score (P<0.01). The psychomotor developmental index of K-BSID-II was also significantly correlated with every KICDT score except the fine motor score (P<0.01). The mental developmental index of K-BSID-II showed significant correlation [Editor20] with the KICDT gross motor, fine motor, and language scores (P<0.05). Further, there was significant correlation between the psychomotor developmental index of K-BSID-II and the KICDT gross motor score (P<0.05). Conclusion : There was significant [Editor21]correlation between the results of KICDT and K-BSID-II for infants and children with developmental delay. Although our results suggest that KICDT is useful in assessing developmental delay, further research would be needed to standardize this test.