Metal Artifact Caused by Magnetic Field Strength and Sequence on T1WI-MRI (자기공명영상에서 자장세기와 시퀀스에 따른 아티팩트 변화)

  • Ko, Seong-Jin
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.9
    • /
    • pp.302-308
    • /
    • 2010
  • In MRI, the Ferromagnetic artifact is generated by the metalization within in which the before inspection removal is impossible and the distortion of an image is brought. The distortion measure according to the steel for each sequence of T1 image and magnetic field intensity are analyzed and minimized method is looked into. We used SIEMENS 1.5T and 3.0T MRI for experiment equipment. First, it places within the Phantom making a metalization(Ti+Al, Stainless, Nitinol) on 1.5T, 3.0T MRI and the T1 weighted image for each Sequence is acquired. The distortion of an image and about adjacent portion change of the metal material were compared through the obtained image, we analyzed. In all metalizations, a distortion was generated and a distortion was few in particularly, and Titanium-Aluminium alloy. And the extent of a distortion was worse image in the Turbo spin Echo. The use of the Titanium-Aluminium alloy the inserted in an internal material of the metalization is recommend. and, equipment of 1.5T the patient inserting a metal in an internal is used in an inspection than equipment of 3.0T. Also, the sequence is suitable when it obtains the optimum T1 weighted image of an impersonate to use the Turbo spin Echo.

Evaluation of Artifact and Noise in the Standard and MAR Algorithms with Variation of Examination Conditions of CT (Standard와 MAR 알고리즘에서 CT 검사조건 변화에 따른 인공물과 노이즈 평가)

  • Kim, Young-kuen;Yang, Sook;Wang, Tae-uk
    • Journal of radiological science and technology
    • /
    • v.43 no.2
    • /
    • pp.79-85
    • /
    • 2020
  • The influence of metal artifact in CT image depends on the type of metal materialsm, the reconstruction algorithm, and scan parameters. The presence of metal artifacts was quantitatively evaluated by applying the standard and MAR algorithms through the phantom study. In the change of tube voltage applied the standard algorithm, metal artifact decreased to 44.9% for 80 vs 120 kVp, 24% for 100 vs 120 kVp, while the image taken at 140 kVp increased the artifact by 19% compared to 120 kVp. When the tube current was increased from 100 to 300 mA, there was no significant difference in the CT value and noise. Black band and white strike artifacts occurred up to 65.9% in the adjacent ROI of the metal driver, whereas titanium screw produced lesser metal artifact than that of the metal driver. The combination of 120kVp or higher tube voltage-standard algorithm was effective in removing black band artifacts as well as white streak by high density materials. However, MAR reconstruction algorithm was useful in improving image quality under the environment of low kVp and high density materials, without increase of radiation exposure.