• Title/Summary/Keyword: 금속인공물

Search Result 77, Processing Time 0.03 seconds

Influence of porcelain re-firing on the formation of surface bubble and on the change in shade of metal-ceramic crown exposed to artificial saliva (인공타액에 노출되었던 금속도재관의 재소성이 색조와 표면기포 형성에 미치는 영향에 관한 연구)

  • Park, Ji-Hyun;Yeo, In-Sung;Kim, Sung-Hun;Han, Jung-Suk;Lee, Jai-Bong;Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.2
    • /
    • pp.161-167
    • /
    • 2011
  • Purpose: The purpose of this study was to evaluate the influence of porcelain re-firing on the formation of surface bubble and on the change in shade of metal-ceramic crown exposed to artificial saliva. Materials and methods: Thirty disk-shaped specimens were made in 10 mm diameter with 0.5 mm metal core thickness and 1 mm ceramic thickness. A spectroradiometer was used to determine the CIE Lab coordinates. The number and size of surface bubble were observed with a stereomicroscope. After the exposure to artificial saliva for 7 days, re-firing was performed at glazing temperature. After re-firing, the CIE Lab were calculated, and the number and size of surface bubble were observed again. The change in shade was expressed with ${\Delta}E$. Statistical analysis was done with paired t-test for the change in the number of surface bubble and student t-test for the change in the size of surface bubble (${\alpha$}=0.05). Results: Shade difference was calculated 2.14 ${\Delta}E$ units. The mean number of surface bubble was $1.33{\pm}1.49$ before re-firing, $3.27{\pm}2.90$ after re-firing. After re-firing, the number of surface bubble was significantly increased (P<.05). The mean size of surface bubble was $81.97{\pm}32.03\;{\mu}m$ before re-firing, $142.94{\pm}47.40\;{\mu}m$ after re-firing. After re-firing, the size of surface bubble was significantly increased (P<.05). Conclusion: Shade change after re-firing was perceptible (${\Delta}E$ < 2.0) and clinically acceptable (${\Delta}E$ < 3.7). The number and size of surface bubble was significantly increased after re-firing. Further investigation to decrease the surface bubble on the extra oral repair of metal-ceramic crown, will be needed in future study.

Development and Application of a Novel Mammalian Cell Culture System for the Biocompatibility and Toxicity of Polymer Films and Metal Plate Biomaterials (고분자필름과 금속막 의료소재에 대한 생체적합성 및 독성 평가를 위한 새로운 세포배양시스템의 개발 및 적용)

  • Kwak, Moon Hwa;Yun, Woo Bin;Kim, Ji Eun;Sung, Ji Eun;Lee, Hyun Ah;Seo, Eun Ji;Nam, Gug Il;Jung, Young Jin;Hwang, Dae Youn
    • Journal of Life Science
    • /
    • v.26 no.6
    • /
    • pp.633-639
    • /
    • 2016
  • Biomaterials including polymer, metal, ceramic, and composite have been widely applied for medical uses as medical fibers, artificial blood vessels, artificial joints, implants, soft tissue, and plastic surgery materials owing to their physicochemical properties. However, the biocompatibility and toxicity for film- and plate-form biomaterials is difficult to measure in mammalian cells because there is no appropriate incubation system. To solve these problems, we developed a novel mammalian cell culture system consisting of a silicone ring, top panel, and bottom panel and we applied two polymer films (PF) and one metal plate (MP). This system was based on the principal of sandwiching a test sample between the top panel and the bottom panel. Following the assembly of the culture system, SK-MEL-2 cells were seeded onto Styela Clava Tunic (SCT)-PF, NaHCO3-added SCT (SCTN)-PF, and magnesium MP (MMP) and incubated at 37℃ for 24 hr and 48 hr. An MTT assay revealed that cell viability was maintained at a normal level in the SCT-PF culture group at 24 or 48 hr, although it rapidly decreased in the SCTN-PF culture group at 48 hr. Furthermore, the cell viability in the MMP culture group was very similar to that of the control group after incubation for 24 hr and 48 hr. Together, these results suggest the sandwich-type mammalian culture system developed here has the potential for the evaluation of the biocompatibility and toxicity of cells against PF- and MP-form biomaterials.

Accurate Localization of Metal Electrodes Using Magnetic Resonance Imaging (자기공명영상을 이용한 금속전극의 정확한 위치 결정)

  • Joe, Eun-Hae;Ghim, Min-Oh;Ha, Yoon;Kim, Dong-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.15 no.1
    • /
    • pp.11-21
    • /
    • 2011
  • Purpose : Localization using MRI is difficult due to susceptibility induced artifacts caused by metal electrodes. Here we took an advantage of the B0 pattern induced by the metal electrodes by using an oblique-view imaging method. Materials and Methods : Metal electrode models with various diameters and susceptibilities were simulated to understand the aspect of field distortion. We set localization criteria for a turbo spin-echo (TSE) sequence usingconventional ($90^{\circ}$ view) and $45^{\circ}$ oblique-view imaging method through simulation of images with various resolutions and validated the criteria usingphantom images acquired by a 3.0T clinical MRI system. For a gradient-refocused echo (GRE) sequence, which is relatively more sensitive to field inhomogeneity, we used phase images to find the center of electrode. Results : There was least field inhomogeneity along the $45^{\circ}$ line that penetrated the center of the electrode. Therefore, our criteria for the TSE sequence with $45^{\circ}$ oblique-view was coincided regardless of susceptibility. And with $45^{\circ}$ oblique-view angle images, pixel shifts were bidirectional so we can detect the location of electrodes even in low resolution. For the GRE sequence, the $45^{\circ}$ oblique-view anglemethod madethe lines where field polarity changes become coincident to the Cartesian grid so the localization of the center coordinates was more facilitated. Conclusion : We suggested the method for accurate localization of electrode using $45^{\circ}$ oblique-view angle imaging. It is expected to be a novelmethodto monitoring an electrophysiological brain study and brain neurosurgery.

Study on the calibration phantom and metal artifacts using virtual monochromatic images from dual energy CT (듀얼 에너지 CT의 가상 단색 영상을 이용한 영상 교정 팬텀과 금속 인공음영에 관한 연구)

  • Lee, Jun seong;Lee, Seung hoon;Park, Ju gyung;Lee, Sun young;Kim, Jin ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.1
    • /
    • pp.77-84
    • /
    • 2017
  • Purpose: To evaluate the image quality improvement and dosimetric effects on virtual monochromatic images of a Dual Source-Dual Energy CT(DS-DECT) for radiotherapy planning. Materials and Methods: Dual energy(80/Sn 140 kVp) and single energy(120 kVp) scans were obtained with dual source CT scanner. Virtual monochromatic images were reconstructed at 40-140 keV for the catphan phantom study. The solid water-equivalent phantom for dosimetry performs an analytical calculation, which is implemented in TPS, of a 10 MV, $10{\times}10cm^2$ photon beam incident into the solid phantom with the existence of stainless steel. The dose profiles along the central axis at depths were discussed. The dosimetric consequences in computed treatment plans were evaluated based on polychromatic images at 120 kVp. Results: The magnitude of differences was large at lower monochromatic energy levels. The measurements at over 70 keV shows stable HU for polystyrene, acrylic. For CT to ED conversion curve, the shape of the curve at 120 kVp was close to that at 80 keV. 105 keV virtual monochromatic images were more successful than other energies at reducing streak artifacts, which some residual artifacts remained in the corrected image. The dose-calculation variations in radiotherapy treatment planning do not exceed ${\pm}0.7%$. Conclusion: Radiation doses with dual energy CT imaging can be lower than those with single energy CT imaging. The virtual monochromatic images were useful for the revision of CT number, which can be improved for target coverage and electron densities distribution.

  • PDF

A Study on the Treatment of the Acid Mine Drainage using the Steel Mill Slag (제강 슬래그를 애용한 산성광산배수(AMD)의 처리에 관한 연구)

  • 권순동;김선준
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.6 no.4
    • /
    • pp.206-212
    • /
    • 1999
  • In order to evaluate the applicability of steel mill slag as a AMD (Acid Mine Drainage) neutralizer and to compare capacity of slag with that of limestone lab scale experiments were conducted. The fixed treatment experiments of AMD with slag and limestone separately for 24 hours under the stagnant condition showed that slag has higher capacity of pH increase and removal of Fe. Al and other trace elements. During the 10 days continuous step experiment the pH has been maintained and any decrease in the removal capacity of Fe and Al has not bun observed. In the trace element removal experiment slag showed higher capacity for removal of Ni, Co. Cu and Zn than limestone. The removal of trace element was more effective in AMD than in distilled water that the pH was adjusted to the same level of AMD (synthetic acid solution). It means that Fe and Al in AMD adsorbed trace elements during or after precipitation as oxide forms. In the size effect experiment, the slag of the smaller size with larger specific surface area exhibited higher capacity of pH increase and removal efficiencies of Fe. Al and other trace elements.

  • PDF

타이타늄 소재의 치과용 임플란트 표면처리 기술

  • Kim, Myeong-Deok
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.05a
    • /
    • pp.20.1-20.1
    • /
    • 2011
  • 타이타늄의 내부식 특성은 분해하기 어려운 산화물의 보호피막을 형성 함으로서 무독성의 생체친화적 성질을 가지고 있어 심장밸브, 인공 뼈 등 신체 조직의 이식에 사용될 만큼 인체에 무해한 금속으로 의료용으로 많이 응용되고 있다. 본 강연에서는 생체재료로써 의료용 타이타늄의 적용현황을 소개하고, 이를 통해 타이타늄의 가치를 다시 한번 재고하고자 한다. 타이타늄 임플란트에서 그 표면과 골사이의 골유착(osseointegration)은 성공적인 임상결과를 얻기 위한 중요한 요소 중의 하나이다. 1960년대에는 기계가공 된 매끈한 형태의 타이타늄 표면을 시작으로 골유착을 얻고자 하였다. 이러한 시도를 통해 임플란트가 점차 대중화 되면서 1980년대 부터 타이타늄 표면과 골과의 유착을 조기에 실현하고, 골유착 강도를 강화하기 위해 다양한 표면기술이 개발 되기 시작하였다. 크게는 1. 표면적 증대 기술, 2. 화학적 방식을 통한 표면기술, 3. 생체활성 유도형 표면기술, 4. 서방출 등을 응용한 골유도 및 활성 조절형 표면기술 등이 개발되어 제품화 되거나 그 연구가 진행 중에 있다. 다양한 표면기술에 대한 흐름을 이해하고 이에 대한 장, 단점을 이해함으로써 앞으로 기술적으로 극복해 나가야 할 과제를 제시하고자 한다. 또한 다양한 표면기술에 대한 유효성과 그에 대한 중, 장기 안전성에 대한 중요성을 이해하고 이를 평가하기 위한 여러 가지 절차와 방법 소개를 통해 신뢰성 있는 연구개발이 될 수 있기 바란다.

  • PDF

Reduction Kinetics of Zinc Oxide in EAF Dust (전기로 분진중 아금산화물의 환원속도)

  • Moon Seok Min;Kim Tae Wook;Min Dong Joon
    • Resources Recycling
    • /
    • v.11 no.4
    • /
    • pp.37-43
    • /
    • 2002
  • As the consumption of galvanized steels in cans and automobiles and the quantity of scraps increase, the recycling problems of EAF dust become a important problem. Valuable metals such as Fe, Zn, Pb are of continued interest to metallurgists. To recover the valuable metal and to remove the toxicity of EAF dust, high temperature smelting process is or researching as a pilot scale. The Reduction kinetics of Zn in EAF dust is so important in a view of the economic consideration of the process. In this study, the kinetics behavior of Zn in EAF dust were measured as a point of application in high temperature smelting process. The rate control step in ZnO and franklinite is revealed to be chemical reaction on the reaction surface.

Automatic defect detection using intensity and shape information in industrial CT (산업용 CT 영상에서 밝기값 및 형태 정보를 이용한 기공 결함 자동 검출)

  • Ji, Hye-Rim;Hong, Helen
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2012.06c
    • /
    • pp.415-417
    • /
    • 2012
  • 본 논문에서는 산업용 CT 영상에서 다중 해상도 기반의 밝기값 정보와 형태 정보를 이용하여 내부 기공결함을 정확하고 빠르게 검출하는 기법을 제안한다. 첫째, 대용량 CT 데이터에서 계산량을 줄이기 위하여 1/2 해상도로 변환 후 관심영역을 자동 산정하고, 링 또는 금속 인공물 등의 잡음을 제거하기 위해 비등방성 확산 필터링을 수행한다. 둘째, 기공 결함 후보군을 검출하기 위해 밝기값 기반의 결함 검출 기법을 제안한다. 셋째, 결함 검출의 민감도를 향상시키기 위해 형태 정보를 이용한 기공 결함 검출 기법을 제안한다. 넷째, 수행시간 가속화를 위하여 다중 해상도 영상 처리 및 Open MP를 적용한다. 제안방법의 평가를 위하여 육안평가와 정확성 평가, 수행시간을 측정하였다. 정확성 평가는 실제 기공 결함과 제안방법 적용 후 결함 간 중복 픽셀 수로 측정하였다. 실험 결과 평균 중복 픽셀 비율은 91%로 측정되었고, 가장 큰 비율은 99%, 가장 작은 비율은 80%로 측정되었다. 다중 해상도 기법 및 Open MP를 적용함으로써 해상도 데이터 수행시간보다 90% 가속화되었다.

The Effects of a MR Torso Coil on CT Attenuation Correction for PET (PET/CT 검사에 있어서 MR Torso Coil의 CT 감쇄보정에 대한 영향 평가)

  • Lee, Seung Jae;Bahn, Young Kag;Oh, Shin Hyun;Gang, Cheon-Gu;Lim, Han Sang;Kim, Jae Sam;Lee, Chang Ho;Seo, Soo-Hyun;Park, Yong Sung
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.81-86
    • /
    • 2012
  • Purpose : Combined MR/PET scanners that use the MRI for PET AC face the challenge of absent surface coils in MR images and thus cannot directly account for attenuation in the coils. To make up for the weak point of MR attenuation correction, Three Modality System (PET/CT +MR) were used in Severance hospital. The goal of this work was to investigate the effects of MR Torso Coil on CT attenuation correction for PET. Materials and Methods : PET artifacts were evaluated when the MR Torso Coil was present of CTAC data with changing various kV and mA in uniformity water phantom and 1994 NEMA cylinderical phantom. They evaluated and compared the following two scenarios: (1) The uniform cylinder phantom and the MR Torso Coil scanned and reconstructed using CT-AC; (2) 1994 NEMA cylinderical phantom and the MR Torso Coil scanned and reconstructed using CT-AC. Results : Streak artifacts were present in CT images containing the MR Torso Coil due to metal components. These artifacts persisted after the CT images were converted for PET-AC. CT scans tended to over-estimate the linear attenuation coefficient when the kV and mA is increasing of the metal components when using conventional methods for converting from CT number. Conclusion : The presence of MR coils during PET/CT scanning can cause subtle artifacts and potentially important quantification errors. Alternative CT techniques that mitigate artifacts should be used to improve AC accuracy. When possible, removing segments of an MR coil prior to the PET/CT exam is recommended. Further, MR coils could be redesigned to reduce artifacts by rearranging placement of the most attenuating materials.

  • PDF

Effect of Freshwater Discharge on the Seawater Quality (Nutrients, Organic Materials and Trace Metals) in Cheonsu Bay (여름철 천수만 해수에서 담수 대량 방류에 따른 영양염, 유기물 및 미량금속의 변화)

  • LEE, JI-YOON;CHOI, MAN-SIK;SONG, YUNHO
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.24 no.4
    • /
    • pp.519-534
    • /
    • 2019
  • When the fresh water from the artificial lakes (Ganwolho and Bunamho) were discharged to Cheonsu Bay in summer to prevent the flood over the reclaimed farmland near the lakes, the impact on water qualities (nutrients, organic matters, trace metals) within the bay was investigated through four surveys (June, July, August and October, 2011). Dissolved inorganic nitrogen (DIN) increased about as much as 3-4 times over the whole water column when the freshwater was discharged. And the main species composition of DIN changed from ammonia to nitrate. Dissolved inorganic phosphorus (DIP) decreased as much as 2 times in surface waters, but increased as much as 1.5 times in deep waters, and also silicate concentrations increased as much as 3-4 times in deep waters of the inner bay. The N/P ratios in Chunsu bay seawaters were much higher (2 to 7 times) than the Redfield ratio when the freshwaters were discharged, which indicated the phosphorus limiting in the phytoplankton growth. Dissolved organic carbon (DOC) and nitrogen (DON) increased as much as about 2 times. In addition, particulate organic matters (POC, PON, POP, Bio-Si) increased as much as above 2 times in the surface waters of the inner bay. Trace metals (Fe, Mn, Co, Ni, Cu) increased in the surface waters of the inner bay, but dissolved Cd concentrations decreased as much as 2 times. Therefore, when the contaminated fresh waters from the artificial lakes were discharged into the bay, nutrients, organic matters and trace metals generally increased compared to normal period. Since the phytoplankton bloom occurred in the surface waters of the inner bay, dissolved oxygens at the surface waters were oversaturated and hence hypoxic in the deep waters. Highly enriched nutrients concentrations were found in deep waters of the inner bay, which was accompanied with the hypoxic condition. Finally, the water quality in the inner bay of the Chunsu bay was deteriorated from less than grade 3 in normal periods to grade 5 when the freshwaters from the artificial lakes were discharged in summer.