• Title/Summary/Keyword: 금속쐐기필터

Search Result 4, Processing Time 0.018 seconds

Dose Evaluation at The Build Up Region Using by Wedge Filter (쐐기필터 사용에 따른 선량증가 영역에서 선량평가)

  • Kim, Yon-Lae;Moon, Seong-Kong;Suh, Tae-Suk;Chung, Jin-Beom;Kim, Jin-Young;Lee, Jeong-Woo
    • Journal of radiological science and technology
    • /
    • v.37 no.4
    • /
    • pp.341-348
    • /
    • 2014
  • Wedge filter could use to increase the dose distribution at the hot dose regions. We evaluated dose discrepancy at surface and build region in the infield and outfield that Metal Wedge (MW) and Enhance Dynamic Wedge (EDW) were interact with photon. In this paper, we used Gafchromic EBT3 film that had excellent spatial resolution, composed the water equivalent materials and changed the optical density without development. The set up conditions of linear accelerator were fixed 6 MV photon, 100 cm SSD, $10{\times}10cm^2$ field size and were irradiated 400 cGy at Dmax. The dose distribution and absorbed dose were evaluated when we compared the open field with $15^{\circ}$, $30^{\circ}$, $45^{\circ}$ metal wedge and enhanced dynamic wedge. A $15^{\circ}$ metal wedge could increase the surface and build up region dose than using a $15^{\circ}$ enhanced dynamic wedge. A $30^{\circ}$ metal wedge could decrease the surface and build up region dose than using a $30^{\circ}$ enhanced dynamic wedge. A $45^{\circ}$ metal wedge could decrease by large deviation the surface and build up region dose than using a $15^{\circ}$ enhanced dynamic wedge. The dose of penumbra region at outfield were increased on the thick side but were decreased on the thin side. It could be decrease the surface dose and build up region dose, if the metal wedge filters were properly used to make a good dose distribution and not closed the distance of surface.

Dose Distribution According to the Tissue Composition Using Wedge Filter by Radiochromic Film (쐐기필터 사용 시 레디오크로믹 필름을 이용한 조직에 따른 선량분포 연구)

  • Kim, Yon-Lae;Lee, Jeong-Woo;Park, Byung-Moon;Jung, Jae-Yong;Park, Ji-Yeon;Suh, Tae-Suk
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.157-164
    • /
    • 2012
  • The purpose of this study is to analyze the dose distribution when wedge filter is used in the various tissue electron density materials. The dose distribution was assessed that the enhanced dynamic wedge filter and physical wedge filter were used in the solid water phantom, cork phantom, and air cavity. The film dosimetry was suitable simple to measure 2D dose distribution. Therefore, the radiochromic films (Gafchromic EBT2, ISP, NJ, USA) were selected to measure and to analyze the dose distributions. A linear accelerator using 6 MV photon were irradiated to field size of $10{\times}10cm^2$ with 400 MUs. The dose distributions of EBT2 films were analyzed the in-field area and penumbra regions by using dose analysis program. In the dose distributions of wedge field, the dose from a physical wedge was higher than that from a dynamic wedge at the same electron density materials. A dose distributions of wedge type in the solid water phantom and the cork phantom were in agreements with 2%. However, the dose distribution in air cavity showed the large difference with those in the solid water phantom or cork phantom dose distributions. Dose distribution of wedge field in air cavity was not shown the wedge effect. The penumbra width, out of the field of thick and thin, was observed larger from 1 cm to 2 cm at the thick end. The penumbra of physical wedge filter was much larger average 6% than the dynamic wedge filter. If the physical wedge filter is used, the dose was increased to effect the scatter that interacted with photon and physical wedge. In the case of difference in electron like the soft tissue, lung, and air, the transmission, absorption, and scattering were changed in the medium at high energy photon. Therefore, the treatment at the difference electron density should be inhomogeneity correction in treatment planning system.

Dose Distribution of Wedge filter by Dose Rate in LINAC (선형가속기의 선량율에 따른 쐐기필터의 선량분포)

  • Gwon, Taehyeong;Kim, Seunguk;Yoon, Yonghak;Won, Doyeon;Jeong, Kyeonghwan;Jung, Jaeeun;Cho, Juneho
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.5
    • /
    • pp.323-329
    • /
    • 2015
  • This study is aimed at assessing whether dynamic wedge filters are appropriate to be used instead of physical wedge filters. The X-ray energy generated from linear accelerator is commercialize 6 MV and 10 MV. $15^{\circ}$, $30^{\circ}$, $45^{\circ}$, and $60^{\circ}$ of physical wedge filter was irradiated by dose rate 100, 200, 300, 400, 500, and 600 MU/min for each angle and for comparison with a dynamic wedge filter, irradiate 96 times under the same conditions. The measurement conditions are as 100 cm source-film distance and $10{\times}10cm$ irradiated surface. A developed film was scanned and analyzed after a calibration through a dose analysis program and the dose rate was compared after calculating the standard deviation. Dynamic wedge filters make dose, scattered rays and treatment time reduced and very useful due to less irradiated doses to patients. The errors at each dose rate under the same conditions were irrelevant. Thus, treatment based on a high dose rate depending on the patient is expected to be feasible.

고선량율 근접조사치료용 이리듐-192 방사성동위원소의 교정방법 비교 ${\cdot}$ 연구

  • Heo, Hyeon-Do;Park, Seong-Yong;Lee, Re-Na;Sin, Dong-O;Gwon, Su-Il;No, Jun-Gyu;Choe, Jin-Ho
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2004.11a
    • /
    • pp.78-80
    • /
    • 2004
  • 본 연구에서는 쐐기형태의 선량분포를 구현할 수 있도록 고안된 미국 Varian사 동적쐐기(EDW ; Enhanced Dynamic Wedge)의 표면선량(surface dose)과 주변선량(peripheral dose) 특성을 분석하였다. 쐐기각도 15${\circ}$, 30${\circ}$, 45${\circ}$, 50${\circ}$를 대상으로 금속쐐기를 사용했을 경우와 동적쐐기를 사용했을 경우에 대해 해당 선량특성을 비교, 분석하였다. 표면선량 측정 결과, 동적쐐기가 금속쐐기보다 더 높은 선량 분포를 보였으며, 주변선량의 경우, 금속쐐기가 동적쐐기보다 더 높은 선량분포를 보였다. 이는 금속쐐기의 빔 필터링에 의한 빔 경화(hardening) 현상과 광자선과의 산란 현상에 기인한 결과로 방사선치료 계획 시 동적쐐기의 적용에 있어 고려해야 할 주요 특성이라 사료된다.

  • PDF