• Title/Summary/Keyword: 금속실리콘

Search Result 450, Processing Time 0.039 seconds

Development and Application of a Novel Mammalian Cell Culture System for the Biocompatibility and Toxicity of Polymer Films and Metal Plate Biomaterials (고분자필름과 금속막 의료소재에 대한 생체적합성 및 독성 평가를 위한 새로운 세포배양시스템의 개발 및 적용)

  • Kwak, Moon Hwa;Yun, Woo Bin;Kim, Ji Eun;Sung, Ji Eun;Lee, Hyun Ah;Seo, Eun Ji;Nam, Gug Il;Jung, Young Jin;Hwang, Dae Youn
    • Journal of Life Science
    • /
    • v.26 no.6
    • /
    • pp.633-639
    • /
    • 2016
  • Biomaterials including polymer, metal, ceramic, and composite have been widely applied for medical uses as medical fibers, artificial blood vessels, artificial joints, implants, soft tissue, and plastic surgery materials owing to their physicochemical properties. However, the biocompatibility and toxicity for film- and plate-form biomaterials is difficult to measure in mammalian cells because there is no appropriate incubation system. To solve these problems, we developed a novel mammalian cell culture system consisting of a silicone ring, top panel, and bottom panel and we applied two polymer films (PF) and one metal plate (MP). This system was based on the principal of sandwiching a test sample between the top panel and the bottom panel. Following the assembly of the culture system, SK-MEL-2 cells were seeded onto Styela Clava Tunic (SCT)-PF, NaHCO3-added SCT (SCTN)-PF, and magnesium MP (MMP) and incubated at 37℃ for 24 hr and 48 hr. An MTT assay revealed that cell viability was maintained at a normal level in the SCT-PF culture group at 24 or 48 hr, although it rapidly decreased in the SCTN-PF culture group at 48 hr. Furthermore, the cell viability in the MMP culture group was very similar to that of the control group after incubation for 24 hr and 48 hr. Together, these results suggest the sandwich-type mammalian culture system developed here has the potential for the evaluation of the biocompatibility and toxicity of cells against PF- and MP-form biomaterials.

Comparative evaluation of marginal and internal fit of metal copings fabricated by various CAD/CAM methods (다양한 CAD/CAM 방식으로 제작한 금속하부구조물 간의 변연 및 내면 적합도 비교 연구)

  • Jeong, Seung-Jin;Cho, Hye-Won;Jung, Ji-Hye;Kim, Jeong-Mi;Kim, Yu-Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.211-218
    • /
    • 2019
  • Purpose: The purpose of the present study was to compare the accuracy of four different metal copings fabricated by CAD/CAM technology and to evaluate clinical effectiveness. Materials and methods: Composite resin tooth of the maxillary central incisor was prepared for a metal ceramic crown and duplicated metal die was fabricated. Then scan the metal die for 12 times to obtain STL files using a confocal microscopy type oral scanner. Metal copings with a thickness of 0.5 mm and a cement space of $50{\mu}m$ were designed on a CAD program. The Co-Cr metal copings were fabricated by the following four methods: Wax pattern milling & Casting (WM), Resin pattern 3D Printing & casting (RP), Milling & Sintering (MS), Selective laser melting (SLM). Silicone replica technique was used to measure marginal and internal discrepancies. The data was statistically analyzed with One-way analysis of variance and appropriate post hoc test (Scheffe test) (${\alpha}=.05$). Results: Mean marginal discrepancy was significantly smaller in the Group WM ($27.66{\pm}9.85{\mu}m$) and Group MS ($28.88{\pm}10.13{\mu}m$) than in the Group RP ($38.09{\pm}11.14{\mu}m$). Mean cervical discrepancy was significantly smaller in the Group MS than in the Group RP. Mean axial discrepancy was significantly smaller in the Group WM and Group MS then in the Group RP and Group SLM. Mean incisal discrepancies was significantly smaller in the Group RP than in all other groups. Conclusion: The marginal and axial discrepancies of the Co-Cr coping fabricated by the Wax pattern milling and Milling/Sintering method were better than those of the other groups. The marginal, cervical and axial fit of Co-Cr copings in all groups are within a clinically acceptable range.

Blood Lead, Manganese, Aluminium and Silicon Concentrations in Korean Adults (한국인의 연, 망간, 알루미늄 및 실리콘의 혈중 농도)

  • Kim, Jung-Man;Ahn, Jung-Mo;Kim, Won-Sul;Kim, Jung-Il;Shin, Hai-Rim;Jung, Kap-Yeol;Kim, Joon-Youn
    • Journal of Preventive Medicine and Public Health
    • /
    • v.33 no.2
    • /
    • pp.157-164
    • /
    • 2000
  • Objectives : This study was peformed to determine the reference values of blood lead, manganese, aluminium, and silicon in healthy adults. Methods : The subjects were 132 (67 male and 65 female), and classified to three age groups $(\leq39,\;40\sim49,\;and\;50\leq)$. Blood lead, manganese and aluminium were analyzed by atomic absorption spectrophotometer, and blood silicon was analyzed by direct current plasma optical emission spectrometer. Results : Blood lead levels(geometric mean, S.D) were (3.49, 1.70) ${\mu}g/dL$ in male and (3.04, 1.65) ${\mu}g/dL$ in female, but the difference is not significant, and there was no significant difference between age groups. Mean blood manganese level was $0.99{\pm}0.41{\mu}g/dL$, and there was no significant difference between sex or age groups. Mean blood aluminium level was $0.59{\pm}0.35{\mu}g/dL$, and there was no significant difference between sex or age groups. Mean blood silicon level was $54.41{\pm}27.64{\mu}g/dL$ in male and $43.34{\pm}23.51{\mu}g/dL$ in female, and the level in male was significantly higher than that in female (p<0.05). There was significant difference between age groups, and the oldest showed the highest level in male (p<0.05), but no significant difference between age groups in female. Conclusions : Authors hope that this study would provide basic data for determining reference values and evaluating health effects.

  • PDF

Transition Metal Dichalcogenide Nanocatalyst for Solar-Driven Photoelectrochemical Water Splitting (전이금속 디칼코제나이드 나노촉매를 이용한 태양광 흡수 광화학적 물분해 연구)

  • Yoo, Jisun;Cha, Eunhee;Park, Jeunghee;Lim, Soo A
    • Journal of the Korean Electrochemical Society
    • /
    • v.23 no.2
    • /
    • pp.25-38
    • /
    • 2020
  • Photoelectrochemical water splitting has been considered as the most promising technology for generating hydrogen energy. Transition metal dichalcogenide (TMD) compounds have currently attracted tremendous attention due to their outstanding ability towards the catalytic water-splitting hydrogen evolution reaction (HER). Herein, we report the synthesis method of various transition metal dichalcogenide including MoS2, MoSe2, WS2, and WSe2 nanosheets as excellent catalysts for solar-driven photoelectrochemical (PEC) hydrogen evolution. Photocathodes were fabricated by growing the nanosheets directly onto Si nanowire (NW) arrays, with a thickness of 20 nm. The metal ion layers were formed by soaking the metal chloride ethanol solution and subsequent sulfurization or selenization produced the transition metal chalcogenide. They all exhibit excellent PEC performance in 0.5 M H2SO4; the photocurrent reaches to 20 mA cm-2 (at 0 V vs. RHE) and the onset potential is 0.2 V under AM1.5 condition. The quantum efficiency of hydrogen generation is avg. 90%. The stability of MoS2 and MoSe2 is 90% for 3h, which is higher than that (80%) of WS2 and WSe2. Detailed structure analysis using X-ray photoelectron spectroscopy for before/after HER reveals that the Si-WS2 and Si-WSe2 experience more oxidation of Si NWs than Si-MoS2 and Si-MoSe2. This can be explained by the less protection of Si NW surface by their flake shape morphology. The high catalytic activity of TMDs should be the main cause of this enhanced PEC performance, promising efficient water-splitting Si-based PEC cells.

Effects of primers on the microtensile bond strength of resin cements to cobalt-chromium alloy (레진 시멘트와 코발트 크롬 합금의 미세인장결합강도에 다양한 프라이머들이 미치는 영향)

  • Jung, Hong-Taek;Campana, Shiela A.;Park, Jin-Hong;Shin, Joo-Hee;Lee, Jeong-Yol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.2
    • /
    • pp.95-101
    • /
    • 2019
  • Purpose: The aim of this study is to evaluate the effects of various primers on the microtensile bond strength (${\mu}TBS$) of resin cements to cobalt-chromium (Co-Cr) dental casting alloy. Materials and methods: Four adhesive primers (Universal primer, Metal primer II, Alloy primer, and Metal/Zirconia primer) and two resin cements (Panavia F2.0, G-CEM LinkAce) were tested. One hundred fifty Co-Cr beams were prepared from Co-Cr ingots via casting ($6mm\;ength{\times}1mm\;width{\times}1mm\;thick$). The metal beams were randomly divided into ten groups according to the adhesive primers and resin cements used; the no-primer groups served as the control (n = 15). After sandblasting with aluminum oxide ($125{\mu}m$ grain), the metal and resin cements were bonded together using a silicone mold. Prior to testing, all metal-resin beams were examined under stereomicroscope, and subjected to the ${\mu}TBS$ test. The mean value of each group was analyzed via one-way ANOVA with Tukey's test as post hoc (${\alpha}=.05$) using SPSS software. Results: The mean ${\mu}TBS$ of all groups was ranged from 20 to 28 MPa. There is no statistically significant difference between groups (P > .05). Mixed failure, which is the combination of adhesive and cohesive failures, is the most prevalent failure mode in both the Panavia F2.0 and G-Cem LinkAce groups. Conclusion: The ${\mu}TBS$ of all tested groups are relatively high; however, the primers used in this study result in no favorable effect in the ${\mu}TBS$ of Panavia F2.0 and G-Cem LinkAce resin cement to Co-Cr alloy.

Fabrications and Analysis of Schottky Diode of Silicon Carbide Substrate with novel Junction Electric Field Limited Ring (새로운 전계 제한테 구조를 갖는 탄화규소 기판의 쇼트키 다이오드의 제작과 특성 분석)

  • Cheong Hui-Jong;Han Dae-Hyun;Lee Yong-Jae
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.7
    • /
    • pp.1281-1286
    • /
    • 2006
  • We have used the silicon-carbide(4H-SiC) instead of conventional silicon materials to develope of the planar junction barrier schottky rectifier for ultra high breakdown voltage(1,200 V grade). The substrate size is 2 inch wafer, Its concentration is $3*10^{18}/cm^{3}$ of $n^{+}-$type, thickness of epitaxial layer $12{\mu}m$ conentration is $5*10^{15}cm^{-3}$ of n-type. The fabticated devices are junction barrier schottky rectifier, The guard ring for improvement of breakdown voltage is designed by the box-like impurity of boron, the width and space of guard ring was designed by variation. The contact metals to rectify were used by the $Ni(3,000\:{\AA})/Au(2,000\:{\AA})$. As a results, the on-state voltage is 1.26 V, on-state resistance is $45m{\Omega}/cm^{3}$, maximum value of improved reverse breakdown voltage is 1180V, reverse leakage current density is $2.26*10^{-5}A/CM^{3}$. We had improved the measureme nt results of the electrical parameters.

Growth and Characterization of Catalyst-Free InAs Nanowires on Si (111) by MBE

  • Hwang, Jeong-U;Park, Dong-U;Ha, Jae-Du;An, Heung-Bae;Kim, Jin-Su;Kim, Jong-Su;No, Sam-Gyu;Kim, Yeong-Heon;Lee, Sang-Jun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.353-353
    • /
    • 2012
  • InAs nanowires (NWs)는 나노소자스케일의 전자소자나 광전자소자를 위한 기본 단위(building block)로 사용될 수 있고, 1차원적 나노구조를 가지면서 나타나는 특별한 전기적, 광학적 특성으로 인해 전계효과 트랜지스터, 레이저, 광발광 다이오드, 가스 검출 센서 등의 많은 응용소자로 활용을 위한 연구가 진행되 있으며 주로 실리콘, 갈륨비소 기판 위에 금속유기기상 증착(MOCVD) 또는 분자선 증착 (MBE)을 이용하여 선택적 수직배열 성장 조절을 위한 연구와 특성 평가 연구가 주로 이뤄지고 있다. 본 연구에서는 InAs NWs를 MBE 장치를 이용하여 Si(111) 기판 위에 Au와 같은 촉매를 사용하지 않고 Si과 InAs의 큰 격자 불일치로 인하여 성장되는 Volmer-weber 성장 모드를 이용 하였다. InAs NW 성장모드는 Si ($5.4309{\AA}$)과 InAs ($6.0584{\AA}$) 사이에 큰 격자상수 차이를 이용하게 되는데 촉매를 사용하여 성장하는 일반적인 이종 화합물 반도체 성장 모드와 달리 액상상태가 존재하지 않고 바로 In과 As이 Si 기판 위를 이동하여 수직방향으로 성장이 이루어지는 vaporsolid(VS) 모드이다. InAs NW V-S 성장 모드는 Si 기판과의 격자 상수차에 의한 스트레스를 이용해야 하므로 Si기판 위에 존재하는 native oxide는 완벽히 제거되어야 한다. InAs NW 최적 성장 조건을 찾기위해 V/III raitio, 성장 온도, 기판표면처리 등의 성장 변수를 변화 시켜가며 실험을 수행하였다. Native oxide를 제거하기 위하여 HF와 buffered oxide etchant (BOE)를 사용하였다. InAs NWs 성장조건은 Indium flux를 고정 시키고 V/III ratio는 50~400까지 변화를 주었다. V/III ratio를 200으로 고정을 시키고 성장온도를 $375{\sim}470^{\circ}C$에서 성장 하였다. 이 때 InAs NWs는 $430^{\circ}C$에서 가장 높은 밀도와 aspect ratio를 얻을 수 있었다. Arsenic flux에 대해서는 많을 수록 좋은 aspect ratio를 얻을 수 있었다. 하지만 InAs 구조의 절대 부피는 거의 같다는 것을 확인 할 수 있었고 이는 온도와 V/III ratio가 Indium adatom의 surface migration length에 대하여 중요한 요소로 작용되는 것을 알 수 있었다.

  • PDF

Minimally Invasive Marsupialization for Treating Odontogenic Cysts: Case Reports (최소 침습적 조대술을 이용한 치성낭종의 치료 증례 보고)

  • Ryu, Jiyeon;Shin, Teo Jeon;Hyun, Hong-Keun;Kim, Youngjae;Kim, Jungwook;Kim, Chong-Chul;Jang, Ki-Taeg;Lee, Sang-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.44 no.2
    • /
    • pp.235-242
    • /
    • 2017
  • Marsupialization and decompression constitute a well-established procedure for treating cavitary bone lesions of the jaw. The technique can be a primary treatment option, especially for pediatric patients with large cysts or lesions involving vital anatomical structures, such as a developing tooth germ. In this procedure, a decompression stent, such as a customized acrylic obturator or space-maintaining appliance, silicone tube, or nasal cannula, is inserted to maintain the patency of the cyst. However, this may cause clinical problems, such as irritation or trauma to the adjacent tissues, as well as discomfort to the patient, or failure of the stent due to cyst shrinkage. It can also be a reason for patient noncompliance. In the cases described here, a minimally invasive marsupialization technique using a metal tube made from a 16-gauge needle was used for odontogenic cysts in pediatric patients associated with unerupted teeth. Through this method, the lesions were removed, with patient cooperation, and the cyst-associated teeth erupted spontaneously.

Variation of Discharge in Length of Hard Micro-path of Drip Hose (점적 호스의 경질 미로 길이에 대한 유량의 변화)

  • Kim, J.H.;Woo, M.H.;Song, N.S.;Kim, D.E.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.57-57
    • /
    • 2017
  • Water line은 UV 처리된 호스의 내부에 압력보상 기능이 첨부된 경질의 미로 튜브를 끼워 사용하도록 제작되어 있다. 점적 호스의 외경은 15.8mm이며 대부분 0.5~2.5bar 사이의 압력에 1.5~3.0 L/hr의 유량을 공급한다. 따라서 전적 호스의 내부에 위치한 경질 미로 튜브의 설계는 유량의 압력보상에 밀접한 관계가 있다. 본 연구에서는 경질 미로 튜브를 통과하는 작은 돌기의 수가 압력과 유량에 어떤 영향을 미치는지에 대한 기초적인 실험을 수행하였으며 경질 미로의 압력과 유량 특성에 따른 이론적 해석과의 비교분석을 통하여 새로운 미로의 형상 설계에 활용할 기초적 연구를 수행하고자 하였다. 점적 호스의 성능은 길이(보통 300~400m)에 대한 유량의 균등성을 유지하는 것이며 균등성은 압력보상에 의해 이루어진다. 원통형 미로는 점적 호스의 내부에 삽입되어 원통 부분에 형성된 미로의 길이에 따른 유량의 균등성을 유지하도록 설계되어 있다. 점적 호스의 원통 주변에는 8개의 미로로 구성되어 있으며 미로의 길이를 금속 평면으로 금형 제작하여 투명판에서 미로의 형상을 보이게 하였다. 또한 입구부분에 물을 공급하고 미로의 각 위치별 배출구를 설치하여 압력에 따른 유출량을 전자저울에 측정하여 압력별 유량의 균등성에 대한 데이터를 측정하였다. 유입구의 압력을 0.5, 1.5, 2.5, 3.0bar로 각각 공급하였으며 유출량은 미로의 8개 구간에 따라 측정하였다. 경질 미로의 유출량은 미로의 길이가 짧을수록, 압력이 커질수록 유출량이 높게 나타났다. 또한 미로의 길이가 짧을 경우에는 유출량의 차이가 비교적 크게 나타났으나 미로의 길이가 길수록 압력에 대한 유출량에 대한 차이가 크지 않음을 알 수 있었다. 따라서 경질 미로에서 미로의 길이를 길게 할 경우에는 유출량을 비교적 균일하게 할 수 있음을 보여주고 있다. 반면에 미로의 길이가 길어질수록 압력변화에 따른 유출량이 지수적으로 감소함을 나타내고 있다. 미로의 길이가 7번과 8번에서는 상당히 균일한 성능을 보여주므로 경질 미로의 배출구를 전체적으로 모두 활용함으로써 압력보상을 비교적 균일하게 할 수 있음을 보여주고 있다. 압력보상은 탄성을 가진 실리콘과 미로로 구성될 경우에 가장 큰 효과를 나타내지만 점적 호스와 같이 경질 미로만으로 압력보상을 해야 할 경우에는 경질 미로의 길이가 매우 중요하다.

  • PDF

Design of Metal-Slit Fresnel Lens for Enhanced Coupling Efficiency (광 결합 및 집속도 향상을 위한 금속 슬릿 프레넬 렌즈의 설계)

  • Park, Dong-Won;Jung, Young-Jin;Koo, Suk-Mo;Yu, Sun-Kyu;Park, Nam-Kyoo;Jhon, Young-Min;Lee, Seok
    • Korean Journal of Optics and Photonics
    • /
    • v.20 no.1
    • /
    • pp.1-5
    • /
    • 2009
  • Recently, much research has been done for to realizeing nano-scale photonic circuits based on photonic crystal, plasmonics and silicon photonics in order to overcome fundamental limits of electronic circuits. These limits include such as bottleneck of speed, and size that cannot be reduced. Even though several kinds of coupling schemes have been reported, coupling structures are still large when it is compared with the nano-scale optical circuit. In this paper, we proposed using a very thin Fresnel lens while shortening the focal length of the Fresnel lens as much as possible. We proposed, for the first time, to utilize metal slits that are able to use the optical coupling system between a nano-scale optical circuit and the standard single mode optical fiber for overcoming the limitation of focal length shortening of the Fresnel lens. Comparative study has been carried out with a FDTD simulation between normal and metal slit assisted Fresnel lens. From the result of simulation, we can achieve 65% coupling efficiency for the metal-slit Fresnel lens when the focal length of metal-slit Fresnel lens is just $4{\mu}m$. On the other hand, the coupling efficiency of the normal Fresnel lens is about 43%.