• Title/Summary/Keyword: 근전도 측정

Search Result 222, Processing Time 0.023 seconds

Gait Phases Detection from EMG and FSR Signals in Walkingamong Children (근전도와 저항 센서를 이용한 보행 단계 감지)

  • Jang, Eun-Hye;Chi, Su-Young;Lee, Jae-Yeon;Cho, Young-Jo;Chun, Byung-Tae
    • Science of Emotion and Sensibility
    • /
    • v.13 no.1
    • /
    • pp.207-214
    • /
    • 2010
  • The aim of this study was to investigate upper and lower limb muscle activity using EMG(electromyogram) sensors while walking and identify normal gait pattern using FSR(force sensing resistor) sensor. Fifteen college students participated in this study and their EMG and FSR signal were measured during stopping and walking trials. EMG signals from upper(pectoralis major and trapezius) and lower limbs(rectus femoris, biceps femoris, vastus medialis, vastus lateralis, semimembranosus, semitendinosus, soleus, peroneus longus, gastrocnemius medialis, and gastrocnemius lateralis) were obtained using the surface electrodes. FSR measured pressures on 8 areas of the sole of the foot during walking. EMG results showed that all muscle activities except for vastus lateralis and semimembranosus during walking had higher amplitudes than stopping. Additionally, muscle activities associated with stance and swing phase during walking were identified. Results on FSR showed that stance and swing phases were detected by FSR signals during a gait cycle. Eight gait phases-initial contact, loading response, mid stance, terminal stance, pre swing, initial swing, mid swing, and terminal swing- were classified.

  • PDF

The Virtual Robot Arm Control Method by EMG Pattern Recognition using the Hybrid Neural Network System (혼합형 신경회로망을 이용한 근전도 패턴 분류에 의한 가상 로봇팔 제어 방식)

  • Jung, Kyung-Kwon;Kim, Joo-Woong;Eom, Ki-Hwan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.10
    • /
    • pp.1779-1785
    • /
    • 2006
  • This paper presents a method of virtual robot arm control by EMG pattern recognition using the proposed hybrid system. The proposed hybrid system is composed of the LVQ and the SOFM, and the SOFM is used for the preprocessing of the LVQ. The SOFM converts the high dimensional EMG signals to 2-dimensional data. The EMG measurement system uses three surface electrodes to acquire the EMG signal from operator. Six hand gestures can be classified sufficiently by the proposed hybrid system. Experimental results are presented that show the effectiveness of the virtual robot arm control by the proposed hybrid system based classifier for the recognition of hand gestures from EMG signal patterns.

The Effect of Head Posture on Muscle Activity of Upper Trapezius During Computer Work (컴퓨터 작업시 머리자세가 상부 승모근의 근 활성도에 미치는 영향)

  • Jung, Do-Young;Koh, Eun-Kyung;Kim, Young;Kwon, Oh-Yun;Lee, Jun;Lee, Kyoung-Joung
    • Physical Therapy Korea
    • /
    • v.9 no.4
    • /
    • pp.53-59
    • /
    • 2002
  • 본 연구는 컴퓨터 작업시 머리자세가 상부 승모근의 근전도 활성도에 미치는 영향에 대해 알아보기 위해 실시하였다. 대상자는 상지에 근골계질환이 없는 대학생 5명을 대상으로 하였으며, 표면근전도(MP100WS)를 이용하여 근 활성도를 측정하였다. 실험은 10분 동안 머리를 중립자세로 모니터를 보고 컴퓨터 작업을 수행하는 것과 문서걸이(copy holder)를 보기 위해 머리를 $45^{\circ}$ 회전하고 컴퓨터 작업을 하는 두 가지 조건을 $%RVC_{RMS}$를 이용하여 비교 분석하였다. 머리를 중립자세로 했을 때 평균 $%RVC_{RMS}$ 값이 높았으나 머리를 $45^{\circ}$ 회전하여 작업시에는 시간이 지남에 따라 $%RVC_{RMS}$가 지속적으로 증가함을 보여주었다. 따라서 컴퓨터 작업시 문서는 모니터로부터 가까이 하여 머리회전을 최소화시키는 것이 근육의 피로나 부작용을 줄일 수 있을 것이다.

  • PDF

Isolated Activation of the Upper Trapezius in Three Manual Muscle Testing Position : Convergence Study (세 가지 도수근력 검사 자세에서 상부 승모근의 독립적 수축 : 융합적 연구)

  • Ha, Sungmin
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.1
    • /
    • pp.83-88
    • /
    • 2020
  • The purpose of this study was to investigate the optimal position among three manual muscle tested positions for upper trapezius in which to obtain an isolated upper trapezius EMG signal for the normalization of upper trapezius muscle EMG activity. A total of 28 healthy adult men participated in the experiment. The UT (upper trapezius) and LS (levator scapulae) muscle activities were measured using the TeleMyo 2400T and analyzed using MyoResearch software. The muscle activity of the US and LS was measured by performing three manual muscle test positions for the upper trapezius. The UT/LS ratio during the S-MVIC was 80.25 and was significantly higher than that during the T-MVIC (76.50; p = 0.011) and the C-MVIC (60.95; p < 0.001). And, the UT/LS ratio during the T-MVIC and was significantly higher than that during the C-MVIC (p < 0.001). Based on the results of present study, we suggest a switch from T-MVIC to S-MVIC for the independent normalization reliability of upper trapezius EMG activity. The UT muscle strength or normalization test using S-MVIC will be able to measure muscle strength or activity of UT compared to previous measurement methods.

A Study of Relationship Between EMG Activation of Thigh Muscle(Rectos Femoris, Vastus Iateralis Muscles) and Knee Angle During Bicycle Exercise (대퇴근활성화에 대한 자전거 운동 시 근전도와 슬관절 각도와의 상관관계 연구)

  • Jang, Won-Seuk;Kim, Sung-Min;Kang, Seung-Ho;Kim, Nam-Hyun
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.46 no.4
    • /
    • pp.77-83
    • /
    • 2009
  • In this study, we investigated relationship of muscular activity in thigh muscle and knee joint angle from bicycle exercise. The EMG signals of 16 persons were measured from rectus femoris and vastus lateralis muscles. The experiment was performed in 5 steps according to saddle distance and 60RPM/200W loads were applied for 1 minute at each step. EMG activation of rectus femoris and vastus lateralis muscles and knee joint angle were recorded using surface EMG and motion analysis system, respectively. Experimental results of inter relationship between EMG activation of thigh muscles and knee joint angle showed high correlation from Step 1. The unified EMG activation of two muscles and knee joint angle showed negative correlation(-0.97).

The Study of Muscle Fatigue Index Searching in terms of Median Frequency Analysis of EMG Signals during Isotonic Exercise (등장성운동 시 근전도 신호의 중앙주파수 분석을 통한 근피로지수 검출에 관한 연구)

  • 홍수용;이성호;윤형로;조상현
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.3
    • /
    • pp.175-181
    • /
    • 2003
  • Studies of muscle fatigue have mostly been checked under isometric exercise. However EMG signals from isotonic exercise generate uncontrollable noise, so there were difficulties in gathering reliable median frequency and muscle fatigue index if frequency analysis was equally applied in isometric exercise. This study tried to compare the differences of muscle fatigue determinant variables in terms of median frequency searching methods of EMG signal, which was estimated in isotonic exercise. To accomplish this, we determined median frequency by using different FFT intervals and overlapping ration of consecutive FFT sections under the same EMG signal, and then searched for a linear regression line, and compared initial median frequency, slope, and muscle fatigue index which were variables under the linear regression line. In result of comparison, initial median frequency was more elevated as FFT exercise interval became larger. The slope of the linear regression line showed distinguishable decreasing tendency as FFT intervals were larger and overlapping sections were smaller. Significant tendency of muscle fatigue index in FFT interval was shown by high muscle fatigue index in specific FFT intervals.

A study on upper extremity muscle fatigue changes of train driver (기관사 상지 근육의 피로도 변화에 대한 연구)

  • Jang, Hye-Yoen;Lee, Yung-Gi;Jang, Jae-Ho;Kim, Tae-Sik;Hong, Sung-Jun;Han, Chang-Soo;Han, Jung-Soo;Ahn, Jae-Yong
    • Journal of the Korean Society for Railway
    • /
    • v.10 no.5
    • /
    • pp.576-581
    • /
    • 2007
  • The purpose of this study is to investigate changes in the forearm-muscle fatigue of a train driver operating the MasCon by using EMG (electromyogram) measurement technique. Train drivers usually use their forearm 4hours/day for normal operation. Accordingly, few different EMG signals of deltoid, biceps brachii, brachioradialis, flexor carpi ulnaris muscle of upper extremity have been measured and analyzed. The raw EMG Signals have been converted into median frequency using spectrum analysis. As the result, 80% of 10 subjects (real train drivers) showed that median frequency value of all four muscles has been reduced after 30 minutes of train operation. This results demonstrated that operating MasCon for 30 minutes could induce muscle fatigue.

Effects on stability of handedness and footedness preference after rotation in place (선호손과 발에 따른 제자리 회전 후 안정성에 미치는 영향)

  • Park, Jun-Sung;Woo, Byung-Hoon
    • Journal of the Korean Applied Science and Technology
    • /
    • v.39 no.4
    • /
    • pp.507-516
    • /
    • 2022
  • The purpose of this study was to investigate the effect of rotational preference on body stability based on COP and EMG analysis in an quiet standing after turn in the left and right directions. The subjects of this study were 16 subjects with a high lateral preference for the right hand and foot. The subjects of this study were 16 subjects with high unilateral preference for the right hand and foot, and three rotational direction conditions (QS: quiet standing, LT: 10 turns on the left, RT: 10 turns on the right) were performed. In order to evaluate the stability in an quiet standing after turning, the results were derived and analyzed using a COP plate and an EMG. As a result of the study, LT and RT were larger than QS for all COP variables, but there was no difference according to the direction of turning. In EMG, RT showed larger muscle activity than the QS according to the rotational direction in left and right gastrocnemius. In conclusion, although all subjects had a high right lateral preference, there was no effect of rotational preference in COP, and gastrocnemius showed the effect of rotational preference.

Development of EMG-Triggered FES System and Optimal Electrode Location for Chronic Hemiplegic Patients (편마비 환자를 위한 근전도 유발 기능적 전기자극기의 개발과 이상적인 전극부착 위치)

  • 박병림;안상호;정호춘;진달복;김성곤;이상세;김영기
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.2
    • /
    • pp.151-156
    • /
    • 2004
  • The purpose of this study was to develop EMG triggered FES system for restoration of upper extremity function in chronic hemiplegic patients and to identify the optimal location of electrode application for the EMG triggered FES system which produces effective muscle contraction and detects EMG activity for extension in the wrist and finger joints. The stimulus system was composed of EMG measuring component, constant current component and the program for muscle contraction by EMG triggered FES and passive FES. Parameter of electrical stimulation was 35 ㎐ in frequency, 150 ${\mu}\textrm{s}$ in pulse width and symmetric bi-phasic wave. In 15 hemiplegic patients, EMG triggered FES was applied to the proximal half of forearm which was divided into 12 areas. The most sensitive area for measuring EMG activities during extension of the wrist and fingers was area 4, 5 and the optimal location of electrical stimulation for producing extension of the wrist and fingers was area 4, 5, 7, 8. These results suggest that the area 4 and 5 was considered as the most optimal location of electrode application for measuring EMG activities as well as producing extension of the wrist and fingers by EMG triggered FES system.