• 제목/요약/키워드: 근전도계

Search Result 36, Processing Time 0.031 seconds

The Effects of Low-Frequency Electrical Stimulation on Abdominal Core Muscle Activity and Thickness (저주파 전기자극이 복부 중심근육 활성도 및 두께에 미치는 영향)

  • Lee, H.J.;Lee, J.Y.;Tae, K.S.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.7 no.2
    • /
    • pp.85-90
    • /
    • 2013
  • Core muscle is the most crucial for rehabilitation of patients with musculoskeletal and nervous problem, there is pain, imbalance and functional movement disorder of upper and lower extremities. In this study, low-frequency electrical stimulator was developed for the purpose increasing the activity of rectus abdominis (RA) and the thickness of transverse abdominis (TrA), internal obliquus abdominis (IO), and external obliquus abdominis (EO). Fifteen female in their 20's was divided into a experiment groups (traditional electrical stimulation group, developed electrical stimulation group) and control group. Low-frequency electrical stimulation was performed in experimental groups for 4 times a week, 4 weeks. The muscle activities (RA) by EMG and muscle thickness (TrA, IO, EO) by Ultrasonogrphy imaging were measured, respectively. In the result, the muscle activity of RA and muscle thickness of TrA and EO were significantly increased at developed electrical stimulation group (p<.05). Therefore, the developed low-frequency electrical stimulation is useful for rehabilitation with CNS and PNS subjects.

  • PDF

A Study on the Gesture Based Virtual Object Manipulation Method in Multi-Mixed Reality

  • Park, Sung-Jun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.26 no.2
    • /
    • pp.125-132
    • /
    • 2021
  • In this paper, We propose a study on the construction of an environment for collaboration in mixed reality and a method for working with wearable IoT devices. Mixed reality is a mixed form of virtual reality and augmented reality. We can view objects in the real and virtual world at the same time. And unlike VR, MR HMD does not occur the motion sickness. It is using a wireless and attracting attention as a technology to be applied in industrial fields. Myo wearable device is a device that enables arm rotation tracking and hand gesture recognition by using a triaxial sensor, an EMG sensor, and an acceleration sensor. Although various studies related to MR are being progressed, discussions on developing an environment in which multiple people can participate in mixed reality and manipulating virtual objects with their own hands are insufficient. In this paper, We propose a method of constructing an environment where collaboration is possible and an interaction method for smooth interaction in order to apply mixed reality in real industrial fields. As a result, two people could participate in the mixed reality environment at the same time to share a unified object for the object, and created an environment where each person could interact with the Myo wearable interface equipment.

Total Intravenous Anesthesia with Alfaxalone and Remifentanil in Dogs Premedicated with Xylazine or Acepromazine (개에서 Alfaxalone과 Remifentanil의 병용 지속주입 마취법 비교 평가)

  • Hong, Young-Ok;Yun, Sung-Ho;Lee, Hyun;Kwon, Young-Sam;Jang, Kwang-Ho
    • Journal of Veterinary Clinics
    • /
    • v.30 no.6
    • /
    • pp.428-434
    • /
    • 2013
  • The combinations of alfaxalone and remifentanil constant rate infusion in dogs premedicated with xylazine or acepromazine were compared. Ten beagle dogs were used and assigned randomly into 2 groups (5 dogs for each group). In group AAR, dogs were premedicated with 0.02 mg/kg of intravenous acepromazine at 15 min before induction. In group XAR, 1.1 mg/kg of intravenous xylazine was premedicated at 5 min before induction. In both groups, anesthesia was induced with alfaxalone and maintained with the combination of alfaxalone (6 mg/kg/hr, IV) and remifentanil (0.05 ${\mu}g/kg/min$, IV). bispectral index score was decreased after induction of anesthesia compared with baseline in both groups and no steep increase was observed during anesthesia. Bispectral index scores and electromyographs in group XAR were significant decreased compared with those in group AAR. Although the pulmonary depression in group XAR and tachycardia in group AAR should be considered to use these regimes, the combinations of alfaxalone and remifentanil constant rate infusion in dogs premedicated with xylazine or acepromazine provided adequate analgesia and anesthesia in this study.

Analysis Characteristic the Using Surface Electromyography of Head Neck and Around of Shoulder Muscles Express Scaling Working of the Dental Hygienist (치과위생사의 스켈링 작업 시 발현되는 두경부 및 견부 주위 근육들의 표면 근전도를 이용한 특성 분석)

  • Jeon, Eun-Suk;Nam, Kun-Woo;Ha, Mi-Sook
    • Journal of dental hygiene science
    • /
    • v.12 no.4
    • /
    • pp.437-442
    • /
    • 2012
  • The current research examines the aching part and the muscle activity that happens during scaling practice subject to 20 dental hygienic students and therefore propose a basic data according to the working attitude of the Dental Hygienist. During the scaling we used the free EMG (BTS Inc., Milan, Italy) to measure the muscle activity, and in order to check the musculoskeletal pain area we used the Nordic-style questionnaire, and the measured research results are as following: At the moment of scaling according to posture the occurrence of the pain showed no difference among the groups elbow, back, leg, knee, ankle/foot but in the neck, shoulder, wrist/hand, waist showed a high difference in the degree of pain according to posture. Results from measuring the muscular activity according to posture, in the group that had a good posture, the trapezius and brachial muscles showed a change according to time, and in the group that had a bad posture a high muscle activity was shown in larynx, trapezius and brachial muscles. In the muscle activity, the changing aspect between the two parts, the group that fulfilled a scaling in a good posture showed a low muscle activity, but in the group that fulfilled the scaling in a bad posture the muscle activity increased excessively. Therefore we examined that when fulfilling a scaling maintaining a bad posture can help in using more effectively the activity of the muscle, in the future I think there is a need to raise the office efficiency by subjecting to dental hyginiest that are in the clinics and performing experiments.

Effects of Height of the Shoe Heel in a Static Posture on Muscle Activity of the Rectus Abdominis, Erector Spinae, Rectus Femoris and Hamstring (구두 굽의 높이가 한다리 서기 자세에서 배곧은근, 척추세움근, 넙다리곧은근, 뒤넙다리근의 근활성도에 미치는 영향)

  • Lee, Won-Hwee;Lee, Hyeon-Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.3
    • /
    • pp.224-230
    • /
    • 2016
  • The purpose of this study was to examine the effects of height of the shoe heel in a one leg standing posture on the muscle activity of the rectus abdominis, erector spinae, hamstring, and rectus femoris. Twenty healthy female subjects were asked to perform a one leg standing posture with three types of shoes, which had different heights of shoe heel, 0cm, 3cm, and 7cm. Surface electromyography was used to evaluate the activities of the right rectus abdominis, erector spinae, hamstring, and rectus femoris muscles. The data was analyzed by repeated one-way ANOVA and the muscle activities among three heights of shoe heel were compared. The results showed that the muscle activities of the erector spinae and rectus femoris increased significantly according to increase height of shoe heel (p<0.05). The activity of the rectus abdominis and hamstring were not significantly different among the three height of shoe heel (p>0.05). These results suggest that the height of shoe heel affects the lumbo-pelvic alignment and center of mass; therefore, high-heeled shoes lead to musculoskeletal pain in the lumbopelvic, hip, and knee areas.

The Effects of Biofeedback Fusion Postural Control Training using Functional Electrical Stimulation on the Muscle Activity and Balance Ability of the Stroke Patient (기능적 전기 자극을 이용한 생체되먹임 융합 자세조절 훈련이 뇌졸중 환자의 근활성도와 균형 능력에 미치는 영향)

  • Kim, Je-Ho;Uhm, Yo-Han
    • Journal of Digital Convergence
    • /
    • v.17 no.12
    • /
    • pp.319-327
    • /
    • 2019
  • The muscle activity and balance ability of the acute stroke patient has been checked by the functional electrical stimulation using biofeedback fusion postural control training in this study. Functional electrical stimulation using biofeedback fusion postural control training have been implemented on 15 trainees and general biofeedback fusion postural control training have been implemented on another 15 trainees for 30 minutes at 5 times per week during 8 weeks, and vastus lateralis, vastus medialis, rectus femoris and biceps femoris have been measured using the biceps femoris to evaluate the muscle activity of the lower extremity. The moving surface area, whole path length and limited of stability have been measured using biorecue to measure the balance ability. There was statistically meaningful difference on the vastus lateralis, vastus medialis, rectus femoris and biceps femoris in the muscle activity of the lower extremity and there was statistically meaningful difference on surface area, whole path length and limited of stability in the balancing ability. Based on above, it is realized that the functional electrical stimulation using biofeedback fusion postural control training is more effective than the general biofeedback fusion postural control training on the improvement of the muscle activity of the lower extremity and the balance ability.