• Title/Summary/Keyword: 근골격계 모델

Search Result 46, Processing Time 0.029 seconds

인체 근골격계 모델의 소개 및 연구 동향

  • Jeong, Ji-Yeong;Kim, Pan-Gwon;Lee, Hui-Jeong;Sin, Chung-Su
    • Journal of the KSME
    • /
    • v.53 no.8
    • /
    • pp.28-33
    • /
    • 2013
  • 이 글에서는 생체 내 근력과 관절 모멘트, 관절 접촉역학 분석에 이용되는 근골격계 생체역학 모델을 소개하고 그 연구 동향에 대해 소개하고자 한다.

  • PDF

Development of a Musculoskeletal Model for Functional Electrical Stimulation - Noninvasive Estimation of Musculoskeletal Model Parameters at Knee Joint - (기능적 전기자극을 위한 근골격계 모델 개발 - 무릎관절에서의 근골격계 모델 특성치의 비침습적 추정 -)

  • 엄광문
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.3
    • /
    • pp.293-301
    • /
    • 2001
  • A patient-specific musculoskeletal model, whose parameters can be identified noninvasively, was developed for the automatic generation of patient-specific stimulation pattern in FES. The musculotendon system was modeled as a torque-generator and all the passive systems of the musculotendon working at the same joint were included in the skeletal model. Through this, it became possible that the whole model to be identified by using the experimental joint torque or the joint angle trajectories. The model parameters were grouped as recruitment of muscle fibers, passive skeletal system, static and dynamic musculotendon systems, which were identified later in sequence. The parameters in each group were successfully estimated and the maximum normalized RMS errors in all the estimation process was 8%. The model predictions with estimated parameter values were in a good agreement with the experimental results for the sinusoidal, triangular and sawlike stimulation, where the normalized RMS error was less than 17%, Above results show that the suggested musculoskeletal model and its parameter estimation method is reliable.

  • PDF

동시획득 T1/T2 강조 경사자장 펄스열을 이용한 근골격계에서의 종양 관류 영상: 예비보고

  • 허용민;서진석;김대용;김은주
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.137-137
    • /
    • 2002
  • 목적: 동시획득 T1/T2 강조 경사자장 펄스열을 이용하여 근골격계의 종양 관류 평가를 하고자 한다. 대상 및 방법: 근골격계 양성 및 악성 종양을 대상으로 동시획득 T1/T2 강조 경사자장 펄스열을 이용하여 시간해상도를 1.2초로 하여 1000회(약20분)를 반복하여 역동적 영상을 얻는다. 각각의 TR/TE1/TE2는 10/2/8 msec이다. 각 시기에서 서로 다른 TE를 가지고 있는 두 개의 영상을 이용하여, 수학적으로 분리하여 T1과 T2 값을 얻고, 이를 시간에 따라 배열한다. 이를 통하여, T2의 경우에는 일차효과를 이용하여 조직관류량(tissue blood volume)을 측정하고, T1에서는 2구획모델을 이용하여 투과도(permeability)를 측정한다.

  • PDF

Analysis on the Effect of Lordosis Changes at Lumbar Joint using 3-dimensional Musculoskeletal Model (근골격계 모델을 이용한 요추전만 각도 변화가 요추 관절에 미치는 영향 분석)

  • Bae, Tae-Soo;Kim, Shin-Ki;Ryu, Je-Chung;Mun, Mu-Seong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.10
    • /
    • pp.116-121
    • /
    • 2009
  • It is important to consider lumbar lordotic angle for setup of training program in field of sports and rehabilitaton to prevent unexpected posture deviation and back pain. The purpose of this study was to analyze the biomechanical impact of the level of lumbar lordosis angle during isokinetic exercise through dynamic analysis using a 3-dimensional musculoskeletal model. We made each models for normal lordosis, excessive lordosis, lumbar kyphosis, and hypo-lordosis according to lordotic angle and inputted experimental data as initial values to perform inverse dynamic analysis. Comparing the joint torques, the largest torque of excessive lordosis was 16.6% larger and lumbar kyphosis was 11.7% less than normal lordosis. There existed no significant difference in the compressive intervertebral forces of each lumbar joint (p>0.05), but statistically significant difference in the anterioposterior shear force (p<0.05). For system energy lumbar kyphosis required the least and most energy during flexion and extension respectively. Therefore during the rehabilitation process, more efficient training will be possible by taking into consideration not simply weight and height but biomechanical effects on the skeletal muscle system according to lumbar lordosis angles.

A Musculoskeletal Model of a Human Lower Extremity and Estimation of Muscle Forces while Rising from a Seated Position (인체 하지부 근골격계 모델 및 의자에서 일어서는 동작 시 근력 예측)

  • Jo, Young-Nam;Yoo, Hong-Hee
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.6
    • /
    • pp.502-508
    • /
    • 2012
  • An analytical model for a human body is important to predict muscle and joint forces. Because it is difficult to estimate muscle or joint forces from a human body, the objective of this study is the development of a reliable analytical model for a human body to evaluate the lower extremity muscle and joint forces. The musculoskeletal system of the human lower extremity is modeled as a multibody system employing the Hill-type muscle model. Muscle forces are determined to minimize energy consumption, and we assume that motion is constrained in the sagittal plane. Muscle forces are calculated through an equilibrium analysis while rising from a seated position. The musculoskeletal model consists of four segments. Each segment is a rigid body and connected by frictionless revolute joints. Muscles of the lower extremity are simplified to seven muscles with those that are not related to the sagittal plane motion are ignored. Muscles that play a similar role are combined together. The results of the present study are compared with experimental results to validate the lower extremity model and the assumptions of the present study.

Pressure Analysis of the Plantar Musculoskeletal Fascia Using a Fine Finite-Element Model (인체 족부 근골격계 상세 유한요소모델링을 통한 족저압 해석)

  • Jeon, Seong-Mo;Kim, Cheol
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.10
    • /
    • pp.1237-1242
    • /
    • 2011
  • The A detailed 3D finite-element analysis model of a human foot has been developed by converting CT scan images to 3D CAD models in order to analyze the distribution of plantar pressure. The 3D foot model includes all muscles, bones, and skin. On the basis of this model and the pressure distribution results, shoes for diabetes patients, which can make the plantar pressure distribution uniform, may be designed through finite-element contact analysis.

The Anisotropic and Viscoelastic Properties of Bone Tissue (근골격계의 골조직이 가지는 이방성 및 점탄성 특성)

  • Kim, Jin-Sung;Kwon, Jung-Sik;Roh, Jin-Ho;Lee, Soo-Yong
    • Composites Research
    • /
    • v.25 no.1
    • /
    • pp.9-13
    • /
    • 2012
  • In this research, biomechanical characteristics of the bone tissue are experimentally investigated. By using specimens of the bovine bone, the mechanical properties are obtained through tension and shear tests. In experiments, non-homogeneous and anisotropic properties with respect to longitudinal and transversal directions are observed. Moreover, the viscoelastic behavior in which modulus and strength properties are dependent on strain rates is analyzed. It is expected that a numerical damage model of the bone be efficiently established based on the results.