• Title/Summary/Keyword: 극한 영향길이

Search Result 56, Processing Time 0.029 seconds

Hydraulic Design of Natural Gas Transmission Pipeline in the Artic Area (극한지 장거리 천연가스 배관의 유동 설계)

  • Kim, Young-Pyo;Kim, Ho-Yeon;Kim, Woo-Sik
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.2
    • /
    • pp.58-65
    • /
    • 2016
  • Hydraulic analysis of the natural gas transmission pipeline is to determine whether adequate flow can be sustained throughout the design life of pipeline under all expected flow conditions. Many factors have to be considered in the hydraulic design of long-distance pipelines, including the nature, volume, temperature and pressure of fluid to be transported, the length and elevation of pipeline and the environment of terrain traversed. This study reviewed the available gas operation data provided by pipeline construction project in the arctic area and discussed the gas properties such as viscosity and compressibility factor that influence gas flow through a pipeline. Pipeline inside diameter was calculated using several flow equations and pipeline wall thickness was calculated from Barlow's equation applying a safety factor and including the yield strength of the pipe material. The AGA flow equation was used to calculate the pressure drop due to friction, gas temperature and pipeline elevation along the pipeline. The hydraulic design in this study was compared with the report of Alaska Pipeline Project.

Drag Coefficient of Water Flow in Gravel Porous Media (자갈 매질 내 흐름의 항력계수)

  • Kim, Yong Hyun;Son, Sang Jin;Na, Raksmey;Park, Sang Deog
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.388-388
    • /
    • 2021
  • 하천에서 호안이나 교량의 교각 등은 홍수 시 주변 하상의 세굴에 의한 피해가 많이 발생한다. 하상보호를 위해서 하천 수공구조물 주변 하상에 자갈, 호박돌, 전석 등을 깔기도 한다. 이 재료들은 다공성 집단을 이루며 유수에 의한 소류력과 항력이 작용한다. 다공성 집단체 공극의 흐름에 의한 항력은 외부 흐름이 가하는 소류력에 비해 작으나 집단의 안정성에 큰 영향을 미칠 수 있다. 집단체에 작용하는 항력은 공극 내의 흐름의 유속과 항력계수를 이용하여 구할 수 있다. 본 연구에서는 다공성 매질 내 흐름에 대한 항력계수를 조사하기 위하여 수리실험을 이용하여 자갈 매질의 공극을 흐르는 물이 일으킨 항력과 동수경사를 측정하였다. 수리실험을 위한 대공극 매질은 상업용 연마 자갈을 사용하여 크기에 따라 작은 자갈(5~10mm), 중간자갈(15~25mm), 큰 자갈(25~50mm)로 구분하였다. 대표입경 D50은 작은 자갈 8.0 mm, 중간 자갈 17.6 mm, 큰 자갈 32.2 mm이고, 형상계수는 각각 0.28~0.74, 0.29~0.58, 0.38~0.68의 범위였다. 자갈 매질의 공극율은 각각 0.405~0.422이었다. 매질 내의 흐름 길이는 24.2cm로 하였다. 실험결과 자갈 매질 내 흐름의 입자 레이놀즈수 Rep에 따른 내부항력 FD와 항력계수 CD는 Fig. 1 및 Fig. 2와 같다. 실험에서 Rep는 31.5~3,175.4였다. 자갈 매질의 내부항력은 Rep가 증가하면 비선형적으로 증가하였으며 입자가 클수록 작았다. 항력계수는 작은 자갈과 중간 자갈 매질에 차이가 거의 없었으나 큰 자갈의 경우 작은 것으로 나타났다.

  • PDF

Flexural Experiment of PSC-Steel Mixed Girders and Evaluation for Analyses on Tangentional Stiffness of Connection (프리스트레스트 콘크리트-강 혼합거더의 휨 실험 및 경계면 수평계수 분석)

  • Kim, Kwang-Soo;Jung, Kwang-Hoe;Sim, Chung-Wook;Yoo, Sung-Won
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.2
    • /
    • pp.231-237
    • /
    • 2008
  • This study was performed to evaluate joint behavior of prestressed concrete(PSC)-steel mixed girders through the flexural test of 14 beams according to embedded length, amount of reinforcing steel, stud arrangement, and prestressing force. All test beams were failed by turns of desertion of reinforcing steel, stud, and steel plate. From test results, prestressing force was more effective on performance of connection than stud arrangement and reinforcing steel. And the spacing of stud is also more effective than embedding length. This paper also presented 3D nonlinear analysis considering the slip of composite section as well as the static load tests of PSC-steel mixed girders. According to the slip modulus, the nonlinear analysis showed that the behavior of hybrid girders could be divided into three parts as full-composite, partial-composite and non-composite. However, the experimental results showed that the PSC-steel hybrid girders with shear connectors took the part of partial composite action in ultimate load stage. In addition, it was founded that stud shear connectors and welded reinforcements were contributed to improve the ultimate strength of hybrid girders for about 20%.

Evaluation of the Effect of Coupler on the Ductility of Rebar by Uniaxial Tensile Test (1축 인장시험을 통한 커플러가 철근 연성도에 미치는 영향 평가)

  • Woo, Tae-Ryeon;Lee, Jong-Han;Cheung, Jin-Hwan;Jung, Chi-Young
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.1
    • /
    • pp.90-98
    • /
    • 2018
  • Recently, various reinforced concrete joints have been used in reinforced concrete structures. Therefore, it is important to grasp the tensile properties of the spliced rebar. In this study, uniaxial tensile tests were conducted on Grade 60 D22(#7), D29(#9), and two kinds of couplers manufactured according to ASTM A615 standard for evaluating ductility of coupler joints. The strain was measured using an image processing method more accurate and capable of measuring at various points freely. As the result of uniaxial tensile test, it was possible to calculate the stress-strain relationship and the longitudinal strain distribution according to the stress stages and it was founded that the average strain becomes lower as more occupying the coupler joint portions in the same gauge length. In addition, the empirical equations are proposed to account for the effect of the length of the coupler on the ultimate strain and the rupture strain.

고출력 펨토초 레이저와 플라즈마의 상호작용을 통한 극고속 X선 펄스의 발생

  • Jeong, Sang-Yeong;Hwang, Seok-Won;Lee, Hae-Jun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.38-38
    • /
    • 2010
  • 낮은 세기의 레이저와 정지한 전자가 반응하면 전자는 레이저 전기장 세기에 비례하여 가속되며 레이저의 파장과 같은 파장의 빛을 낸다. 반면, 레이저의 세기가 일정 수준을 넘으면 전자의 속도가 빛의 속도에 가까워지게 되어 가속이 둔화되는 현상이 나타나며, 더 이상 전기장의 세기와 가속도가 비례하지 않게 된다. 이러한 비선형적인 전자의 운동이 레이저 기본 파장의 조화파(harmonic)를 발생시키는데, 이를 상대론적 비선형 톰슨 산란(relativistic nonlinear Thomson scattering, RNTS)이라고 한다. 단일 전자를 가정한 경우 RNTS에 의해 아토초($10^{-18}$ 초) 길이의 X선 펄스가 발생하는 것이 시뮬레이션 연구를 통해 잘 알려졌다. [1] 그러나, 실제 실험에서 적용할 수 있는 것은 단일 전자가 아니라 고체, 플라즈마, 전자 빔 등의 전자 덩어리이다. 전자덩어리를 구성하는 각각의 전자가 아토초 펄스를 발생시더라도 각각의 펄스 간에 결맞음(coherence) 조건이 맞지 않으면 아토초 펄스는 발생되지 않는다. 또한, 강한 세기의 펄스를 얻는데도 결맞음은 중요하다. 이 연구에서는 결맞음 조건으로 얇은 타깃에 대한 거울 반사 조건, 즉 레이저가 얇은 타깃에 입사되며 거울의 반사 조건을 만족하는 위치에 검출기(detector)를 위치시키는 방법을 제안하였다. 박막이 충분히 얇을 경우 각각의 전자에 대하여 레이저가 발사되어 타깃에 맞고 검출되기까지의 시간이 거의 일치하게 된다. 거울 반사 조건에 의한 아토초 펄스 발생은 particle-in-cell 방법을 통한 시뮬레이션으로 검증되었다. 결맞음 조건을 위한 얇은 타깃으로는 박막과 나노선 배열(nanowire array)을 사용하였다. 전자들 간의 쿨롱(Coulomb) 힘은 결맞음이 유지되는 것을 방해하는데, 박막에 비해 나노선 배열이 쿨롱 힘의 영향을 적게 받기 때문에 결맞음이 더 잘 유지된다.

  • PDF

Model Testing on the Behavior of Laterally Loaded Pile in NC Clay Soils (정규압밀 점토 지반에서 매입말뚝의 수평거동에 관한 모형 실험 연구)

  • Kim, Byeong-Tak;Lee, Sang-Ung;Kim, Yeong-Su
    • Geotechnical Engineering
    • /
    • v.14 no.5
    • /
    • pp.39-52
    • /
    • 1998
  • The pupose of the present paper is to estimate the effects of constraint condition of pile head, ground condition(dry unit weight. $\gamma_4$) and embedded pile lengths on the behavior of single pile which is embedded in normally consolidated clay. BBperiment functions can be quantified to these effects obtained from the results of model teats. The ground of model tests is normally consolidated( NC ) clay under three kinds of effective vertical stress. The results of the model tests using the steel pile of two different embedded pile length and of free-head and fired-head show that the lateral load-deflection relationship is to be elasto plastic behavior below $\gamma_d/\gamma_{dmax}$: 0.84 and that the reduction of lateral load of beyond maximum lateral load($Q_{max}$) at each model test is significantly time-dependent. In this study, it is shown that the displacement relationship can be fitted to exponential function of time by model best results. The effect of ground conditions on the ultimate and yield lateral load is fitted to exponential function including the ratio of dry unit weight to maximum dry unit weight. When tests by results are compared with those from Broms and Budhu et at., the predicted results are over-estimated about 27-87 ayo. In effectivity of constraint condition of pile head on the lateral load-deflection response, the $Q_{fixed}/Q_{gree}-y/D$ relationship is highly non-linear and fitted to parabolic function.

  • PDF

Model Tests on the Lateral Behavior of Steel Pipe Piles(I) in the Nak -dong River Sand (강관말뚝의 수평거동에 대한 모형실험 연구(I) -대구지역 낙동강 모래에 대하여)

  • 김영수;허노영
    • Geotechnical Engineering
    • /
    • v.13 no.5
    • /
    • pp.59-74
    • /
    • 1997
  • This paper shows the results of a series of model bests on the behavior of single steel pipe pile which is subjected to lateral load in Nak-dong river sand. The purpose of the present paper is to estimate the effect of Non -homogeneous soil, constraint condition of pile head, lateral load velocity, relative density of soil, embedded pile length, and flexural stiffness of pile on the behavior of single pile which is embedded in Nak-dong river strand. These effects can be quantined only by the results of model tests. The nonlinear responses of lateral loadieflection relationships are fitted to 2nd polynomial equations by model tests results. Also, the lateral load of a deflection, yield and ultimate lateral load max. bending moment, and yield bending moment can be expressed as exponential function in terms of relative density and deflection ratio. By comparing Brom's results with model results on the lateral ultimate load, it is found that short and long pile show the contrary results with each other. The contrary results are due to the smaller assumed soil reaction than the soil reaction of the Nakiong river sand at deep point. By comparing lateral behavior on the homogeneous soil with non-homogeneous soil, it is shown that lateral loadieflection relationship is very dependent on the upper relative density. This phenomenon is shown remarkably as the difference between upper and lower relative density increases.

  • PDF

Effective Strength of 3-Dimensional Concrete Strut (3차원 콘크리트 스트럿의 유효강도)

  • Yun, Young Mook
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.2
    • /
    • pp.403-413
    • /
    • 2014
  • For the reliable design of the structural concrete by the strut-tie model approaches of current design codes, the effective strengths of concrete struts must be determined with sufficient accuracy. Many values and equations for the effective strengths have been suggested until now. As those are for the two-dimensional concrete struts, however, it is inappropriate to employ them in the strut-tie model designs of three-dimensional structural concretes. In this study, an approach, that determines the effective strengths of three-dimensional concrete struts consistently and accurately by reflecting the state of 3-dimensional stresses, the 3-dimensional failure criteria of concrete, the degree of cracks (or tensile strains of reinforcing bars crossing the struts), the strut's longitudinal length, the deviation angle between strut orientation and compressive principal stress flow, compressive strength of concrete, and the degree of concrete confinement by reinforcing bars, is proposed. To examine the validity of the proposed approach, the ultimate strength analyses of 115 reinforced concrete pile caps tested to failure by previous investigators were conducted by the ACI 318-11's strut-tie model approach with the existing and proposed effective strengths of concrete struts.

Experimental Evaluation of Effective Flexural Rigidity in Reinforced Concrete Beams Considering Tension Stiffening Effect (인장증강효과를 고려한 철근콘크리트 보의 유효휨강성 평가)

  • Lee Seung-Bea;Jang Su-Youn;Kim Sang-Sik;Lee Jin-Seop
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.6 s.90
    • /
    • pp.1033-1042
    • /
    • 2005
  • Until recently tensile stresses in concrete have not been considered, since it does not affect the ultimate strength of reinforced concrete flexural members significantly However, to verify the load-deflection relationship, the effect of tensile stresses between reinforcing bars and concrete, so-called tension stiffening effect must be taken into account. Main parameters of the tension stiffening behavior are known as concrete strength, and bond between concrete and reinforcing bars. In this study total twenty specimens subjected to bending were tested with different concrete strength, coverage, and de-bonding length of longitudinal bars. The effects of these parameters on the flexural rigidity, crack initiation and propagation were carefully checked and analyzed.

Dynamic Behavior Characteristics of Group Piles with Relative Density in Sandy Soil (건조 모래지반의 상대밀도에 따른 무리말뚝의 동적거동특성)

  • Heungtae Kim;Hongsig Kang;Kusik Jeong;Kwangkuk Ahn
    • Journal of the Korean GEO-environmental Society
    • /
    • v.24 no.9
    • /
    • pp.33-40
    • /
    • 2023
  • The lateral load which is applied to the pile foundation supporting the superstructure during an earthquake is divided into the inertia force of the upper structure and the kinematic force of the ground. The inertia force and the kinematic force could cause failure to the pile foundation through different complex mechanisms. So it is necessary to predict and evaluate interaction of the ground-pile-structure properly for the seismic design of the foundation. The interaction is affected by the lateral behavior of the structure, the length of the pile, the boundary conditions of the head, and the relative density of the ground. Confining pressure and ground stiffness change accordingly when the relative density changes, and it results that the coefficient of subgrade reaction varies depending on each system. Horizontal bearing behavior and capacity of the pile foundation vary depending on lateral load condition and relative density of the sandy soil. Therefore, the 1g shaking table tests were conducted to confirm the effect of the relative density of the dried sandy soil to dynamic behavior of the group pile supporting the superstructure. The result shows that, as the relative density increases, maximum acceleration of the superstructure and the pile cap increases and decreases respectively, and the slope of the p-y curve of the pile decreases.