• Title/Summary/Keyword: 그라프트

Search Result 233, Processing Time 0.02 seconds

Synthesis and Characterization of Collagen Peptide Based Copolymer from Shaving Scrap (셰이빙 스크랩으로부터 콜라겐 펩타이드계 공중합체 합성과 특성)

  • Park, Min Seok;Shin, Soo Beom;Kim, Ho Soo;Kim, Min Soo;Kim, Ha Sun;Jang, Jae Hyeok;Lee, Jin Kye;Lee, Dong Kuk
    • Applied Chemistry for Engineering
    • /
    • v.33 no.6
    • /
    • pp.581-587
    • /
    • 2022
  • The leather industry generates a large amount of hazardous leather waste of various types every year. Among them, shaving scrap is difficult to recycle because it contains chromium ions. Many studies in recent years have shown that shaving scraps can be processed into various types of valuable products, such as adsorbent, filler, and poultry feed. In this study, collagen peptides were extracted from shaving scraps and structurally modified to be developed as new materials with improved physicochemical properties. First, the chromium ions contained in the shaving scraps were removed using a sodium hydroxide solution, and purified through concentration and low-temperature crystallization. The purified collagen peptide was used to prepare the powder using a spray dryer. The extracted collagen peptides were structurally modified by introducing double bonds by reacting with methacrylic anhydride (MAA), and the product was confirmed by 1H NMR spectroscopy. Next, a copolymer was prepared by redox polymerization of the modified collagen peptide (MCP) and 2-ethylhexyl acrylate (2-EHA). The structure of the copolymer was qualitatively confirmed by FT-IR. In conclusion, this study confirmed that collagen peptides can be extracted from shaving scrap and converted into new eco-friendly materials through certain treatments.

Delayed Bilateral Common Femoral Pseudoaneurysm after Percutaneous Access with Interventional Management: A Case Report (경피적 접근을 통한 시술 후에 발생한 지연성 양측 총대퇴 가성동맥류 및 인터벤션 치료: 증례 보고)

  • Sang Hoon Lee;Doo Ri Kim;Jeong Sub Lee;In Chul Nam;Su Yeon Ko
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.3
    • /
    • pp.705-712
    • /
    • 2023
  • Common femoral artery pseudoaneurysm is a potentially serious complication of peripheral angiography. There have been few prior reports of simultaneous pseudoaneurysm in both common femoral arteries after percutaneous access. Here we report the case of a 58-year-old male patient who presented with phlegmon or abscess a few days after bilateral femoral access, after which newly developed bilateral femoral pseudoaneurysm with wide neck was observed on CT angiography 2 months after infection treatment. Because the patient refused surgery for pseudoaneurysm, a stent-graft was inserted in the left side, and percutaneous thrombin injection under US guidance with balloon occlusion was performed for the right side. Most pseudoaneurysms occur immediately after the causative procedure. However, there have been some cases in which pseudoaneurysms may occur several weeks or months later; it is therefore necessary to check the risk factors and to carefully observe the hemostasis site.

Experimental Study on the Adhesion and Performance Evaluation of Joints for Modified Polyethylene Coated Steel Pipes (개질 폴리에틸렌 코팅 강관의 부착 및 체결부 성능 평가 연구)

  • Myung Kue Lee;Sanghwan Cho;Min Ook Kim
    • Composites Research
    • /
    • v.37 no.3
    • /
    • pp.238-245
    • /
    • 2024
  • In this study, as part of the development of a monitoring system for the efficient maintenance of steel pipes, an experimental study was conducted to evaluate the performance of steel pipes treated with modified polyethylene coating. In the case of the conventional mechanical pre-coating method, there was a deterioration in polyethylene adhesion during expansion testing, which led to the application of a chemical pre-treatment process using a calcium-mixed phosphate zinc film to resolve this issue. SEM and EDX analyses showed that the densest structure was observed at a Zn/Ca ratio of 1.0, and improved heat resistance compared to the conventional method was confirmed. Additionally, to prevent coating detachment during expansion, an evaluation of adhesion and elongation was conducted on steel pipes with modified polyethylene coating, incorporating materials such as elastomers based on maleic anhydride grafting, metal oxides, blocking agents, and slip agents. Experimental results showed that the specimen (S4) containing all modified materials exhibited more than a 25% performance improvement compared to the specimen (S2) containing only metal oxides. Lastly, the development and performance evaluation of wedge-shaped socketing and pressing wheels, which are part of the pipe fixing accessories, were conducted to prevent surface coating damage on the completed pipes.