• Title/Summary/Keyword: 균일 화질

Search Result 70, Processing Time 0.023 seconds

Coater Die Design and Coating Quality Evaluation in the Machine Direction of Slot Coating Through Computer Simulation (컴퓨터 해석을 통한 Slot 코팅공정에서 운전방향의 코팅품질 평가 및 다이 설계)

  • Kim, T.H.;Lee, D.Y.;Sung, D.J.;Lyu, M.Y.
    • Elastomers and Composites
    • /
    • v.48 no.4
    • /
    • pp.282-287
    • /
    • 2013
  • Slot coating has been widely spread in photo resist coating on glass for flat display monitor. High quality of coating is required as high quality of image in display is needed. Coating quality in the slot coating is divided into nozzle direction quality and machine direction quality. Nozzle direction quality is related to flow uniformity inside the die whereas machine direction quality is related to die lip design and operational conditions. In this study coating uniformity in the machine direction of slot coating has been investigated through computer simulation. Die lip angle and die lip length were considered as outside die geometry and coating speed was considered as operational condition. Coating behavior has been analyzed and coating quality has been evaluated through computer simulation. Coating thickness decreased and coating uniformity increased as coating speed increased. However, the stability of meniscus formation was reduced and subsequently coating stability was reduced as coating speed increased. Coating thickness deviation decreased as die lip angle increased in down stream die. Coating thickness decreased and time to reaching steady state increased as increased die lip length in down stream die.

Development of the Full color LED displays using the control algorithm of histogram distribution (히스토그램 분포 제어가 가능한 풀칼라 LED 디스플레이장치 개발)

  • Ha, Young-Jae;Jin, Byung-Yun;Kim, Sun-Hyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.7
    • /
    • pp.1708-1714
    • /
    • 2010
  • In this paper, the full color LED billboard or a general quality improvement methods of quality gamma correction, brightness, and brightness adjustment, etc., regardless of the overall color of images uniformly bright or dark have been taken care of. The video itself, but simply expressed as a uniform brightness of a certain size, how to adjust the brightness of input video signal does not reflect the characteristics of the entire screen with just a lighter or darker line is only feeling was brought. So, unlike conventional video transmission system with new LED display technology in the histogram analysis of image data is input by the input image data by determining the luminance values of the attributes are reflected, as appropriate based on the histogram of the distribution of brightness values By controlling the LED display is expressed in the uniform image can improve the brightness control, histogram distribution of the image as full color billboards driven processing technology is proposed.

Image Resolution Enhancement by Improved S&A Method using POCS (POCS 이론을 이용한 개선된 S&A 방법에 의한 영상의 화질 향상)

  • Yoon, Soo-Ah;Lee, Tae-Gyoun;Lee, Sang-Heon;Son, Myoung-Kyu;Kim, Duk-Gyoo;Won, Chul-Ho
    • Journal of Korea Multimedia Society
    • /
    • v.14 no.11
    • /
    • pp.1392-1400
    • /
    • 2011
  • In most digital imaging applications, high-resolution images or videos are usually desired for later image processing and analysis. The image signal obtained from general imaging system occurs image degradation during the process of image acquirement caused by the optics, physical constraints and the atmosphere effects. Super-resolution reconstruction, one of the solution to address this problem, is image reconstruction technique that produces a high-resolution image from several low-resolution frames in video sequences. In this paper, we propose an improved super-resolution method using Projection onto Convex Sets (POCS) method based on Shift & Add (S&A). The image using conventional algorithms is sensitive to noise. To solve this problem, we propose a fusion algorithm of S&A and POCS. Also we solve the problem using BLPF (Butterworth Low-pass Filter) in frequency domain as optical blur. Our method is robust to noise and has sharpness enhancement ability. Experimental results show that the proposed super-resolution method has better resolution enhancement performance than other super-resolution methods.

The Effects of Reducing a Dose on the Genital Gland at a CT Scan on the Whole Abdomen According to the Shielding Material (Whole Abdomen CT촬영 시 차폐 재료에 따른 생식선 선량 감쇠 효과)

  • Gang, Eun Bo;Park, Cheol Woo
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.6
    • /
    • pp.419-425
    • /
    • 2016
  • The purpose of this study is to produce a shielding material to reduce a dose on the genital gland, one of the superficial organs, at a CT scan on the whole abdomen and hardly affect picture quality and examine its utility. This research made 22 mm silicone and 7.3 mm aluminum having the similar material quality and effect of previous bismuth. By using the non-shield, bismuth, 22 mm silicone, and 7.3 mm aluminum shielding materials, this author conducted a comparative experiment measuring the decay rate of the genital gland's exposure to radiation, change of the CT number and noise in the image, and the CT number, noise, and uniformity in the AAPM phantom. According to the results, exposure to radiation is reduced in bismuth as 29.96%, silicone 22 mm as 13.10%, and 7.3 mm aluminum as 18.27%. In bismuth, however, the image's CT number varies a lot, and uniformity is measured to be inappropriate in the AAPM phantom scan; therefore, it indicates great change in terms of picture quality in superficial organs like the genital gland. Concerning superficial organs like the genital gland, if 22 mm silicone and 7.3 mm aluminum are used as shielding materials, it will be helpful in reducing variation in picture quality and also decreasing radiation exposure to radiation.

A Feedback Buffer Control Algorithm for H.264 Video Coding (H.264 동영상 부호기를 위한 Feedback 버퍼 제어 방식)

  • Son Nam Rye;Lee Guee Sang
    • The KIPS Transactions:PartB
    • /
    • v.11B no.6
    • /
    • pp.625-632
    • /
    • 2004
  • Since the H.264 encoding adopts both forward prediction and hi-direction prediction modes and exploits Variable Length Coding(VLC), the amount of data generated from video encoder varies as Flaying time goes by. The fixed bit rate encoding system which has limited transmission channel capacity uses a buffer to control output bitstream It's necessary to control the bitstream to maintain within manageable range so as to protect buffer from overflow or underflow. With existing bit amount control algorithms, the $\lambda_{MODE}$ which is relationship between distortion value and quantization parameter often excesses normal value to end up with video error. This paper proposes an algorithm to protect buffer from overflow or underflow by introducing a new quantization parameter against distortion value of H.264 video data. The test results of 6 exemplary data show that the proposed algorithm has the same PSNR as and up to 8% reduced bit rate against existing algorithms.

Grid Acceleration Structure for Efficiently Tracing the Secondary Rays in Dynamic Scenes on Mobile Platforms (모바일 환경에서의 동적 장면의 효율적인 이차 광선 추적을 위한 격자 가속 구조)

  • Seo, Woong;Choi, Byeongjun;Ihm, Insung
    • Journal of KIISE
    • /
    • v.44 no.6
    • /
    • pp.573-580
    • /
    • 2017
  • Despite the recent remarkable advances in the computing power of mobile devices, the heat and battery problems still restrict their performances, particularly compared to PCs. Therefore, in the application of the ray-tracing technique for high-quality rendering, the consideration of a method that traces only the secondary rays while the effects of the primary rays are generated through rasterization-based OpenGL ES rendering is worthwhile. Given that most of the rendering time is for the secondary-ray processing in such a method, a new volume-grid technique for dynamic scenes that enhances the tracing performance of the secondary rays with a low coherence is proposed here. The proposed method attempts to model all of the possible spatial secondary rays in a fixed number of sampling rays, thereby alleviating the visitation problem regarding all of the cells along the ray in a uniform grid. Also, a hybrid rendering pipeline that speeds up the overall rendering performance by exploiting the mobile-device CPU and GPU is presented.

An Estimate of Image Quality and Radiation Doses of Coronary Artery in MDCT Using Prospective and Retrospective ECG Gating Scan Mode (MDCT 관상동맥 조영 검사에서 전향적 동조화 및 후향적 동조화 기법의 화질과 선량 관계)

  • Oh, Jong-Kap
    • Journal of radiological science and technology
    • /
    • v.34 no.4
    • /
    • pp.315-321
    • /
    • 2011
  • The goal of this study is to reduce patient exposure dose by providing image quality and radiation dose according to inspection methods. Volume Computed Tomography Dose Index(CTDIvol) and Dose Length Product(DLP) of prospective and retrospective ECG gating snapshot segment of Coronary CT angiography(CTA) were measured each snapshot segment methods. CT number, noise, uniformity, and resolution were also measured using phantom under the same condition of coronary CTA. The results showed that CT number, noise, uniformity and resolution are similar to each other. In terms of CTDIvol and DLP, however, measurement dose of prospective ECG gating snapshot segment was lower than the retrospective case by 37.5% and 40.3%. Therefore, it is highly recommended that in the coronary CTA, prospective ECG gating scan mode should be chosen to reduce patient dose.

Optimization of Parallel-Hole Collimator for Small Gamma Camera Based on Pixellated Crystal Array (배열형 섬광결정을 이용한 소형 감마카메라의 평행구멍형 조준기 최적화 연구)

  • Chung, Yong-Hyun;Beak, Cheol-Ha;Lee, Seung-Jae;Park, Jin-Hyung
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.291-297
    • /
    • 2008
  • The purpose of this study is to optimize a parallel-hole collimator for small gamma camera having the pixellated crystal array and evaluate the effect of crystal-collimator misalignment on the image quality using a simulation tool GATE (Geant4 Application for Tomographic Emission). The spatial resolution and sensitivity were measured for the various size of hexagonal-hole and matched square-hole collimators with a Tc-99m point source and the uniformity of flood image was estimated as a function of the angle between crystal array and collimator by misalignment. The results showed that the spatial resolution and sensitivity were greatly improved by using the matched collimator and the uniformity was reduced by crystal-collimator misalignment.

  • PDF

Effect of Lactobacillus pentosus-Fermented Artemisiae Argi Folium on Nitric Oxide Production of Macrophage impaired with Various Toxicants (유산균발효애엽이 독성물질들로 유발된 대식세포의 일산화질소생성 감소에 미치는 영향)

  • Park, Wan-Su
    • Journal of Pharmacopuncture
    • /
    • v.12 no.4
    • /
    • pp.89-96
    • /
    • 2009
  • Objectives : The purpose of this study is to investigate the effect of Water Extract from Lactobacillus pentosus-fermented ARTEMISIAE ARGI FOLIUM (AFL) on nitric oxide production of mouse macrophage Raw 264.7 cells impaired by various toxicants such as gallic acid, EtOH, nicotine, acetaminophen, and acetaldehyde. Methods : ARTEMISIAE ARGI FOLIUM was fermented with Lactobacillus pentosus and extracted by water. Nitric oxide production of mouse macrophage Raw 264.7 cells was measured by Griess reagent assay. Examined concentrations of AFL were 10, 50, 100, 200, 400 ug/mL. Results : The results of the experiment are as below. 1. AFL at the concentration of 400 ug/mL significantly recovered nitric oxide production which was reduced by gallic acid (100 uM) in Raw 264.7 cells. 2. AFL at the concentration of 200, 400 ug/mL significantly recovered nitric oxide production which was reduced by EtOH (100 uM) in Raw 264.7 cells. 3. AFL at the concentration of 400 ug/mL significantly recovered nitric oxide production which was reduced by nicotine (1mM) in Raw 264.7 cells. 4. AFL at the concentration of 200, 400 ug/mL significantly recovered nitric oxide production which was reduced by acetaminophen(2 mM) in Raw 264.7 cells. 5. AFL at the concentration of 200, 400 ug/mL significantly recovered nitric oxide production which was reduced by acetaldehyde (200 uM) in Raw 264.7 cells. Conclusions : AFL could be supposed to have the immune-enhancing activity related with nitric oxide production of macrophage impaired by various toxicants.

A New High-Efficient Energy-Recovery Circuit for Plasma Display Panel (새로운 에너지 회수 방식을 채용한 고효율 PDP 구동 회로)

  • 韓 翔 圭;李 俊 榮;文 建 又;尹 明 重;朴 昌 培;丁 南 聲;朴 正 泌
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.2
    • /
    • pp.121-128
    • /
    • 2002
  • A new high-efficient energy-recovery circuit is proposed to drive a plasma display panel (PDP) and compared with the conventional circuit. The proposed circuit uses only two inductors and no auxiliary circuit to recover the energy stored in the equivalent intrinsic capacitance of PDP. Therefore it features a simpler structure, less mass, lower cost of production, higher efficiency, and fewer power devices. The very stable and uniform light emitted from PDP proves the high quality of screen. It is suitable for wall-hanging color TVs. The proposed circuit, operating at 200kHz, is verified to be applicable on a 42-inch PDP by experimental results.