• Title/Summary/Keyword: 균열제어

Search Result 450, Processing Time 0.023 seconds

A Numerical Study on the Characteristics of Plastic Shrinkage Cracking on Concrete Slab with Sequential Placement (분할타설되는 콘크리트 슬래브의 소성수축균열 특성에 대한 해석적 연구)

  • Kwak, Hyo-Gyoung;Ha, Soo-Jun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.4A
    • /
    • pp.795-808
    • /
    • 2006
  • In this paper, an analytical method which can predict the occurrence of plastic shrinkage cracking on concrete slabs with sequential placement is proposed on the basis of the numerical model introduced in the previous study. The influence of many design variables on plastic shrinkage cracking such as the number of layers and the time interval between layers is quantitatively analyzed through parametric studies using the analytical method. In advance, two equations are introduced to take into account the effect of sequential placement on the plastic shrinkage cracking of concrete slab; The first one is to calculate the time at which the surface of concrete slab begins to dry, and the second one is to determine the critical time interval to prevent the surface drying of previously placed concrete layers. The timing of curing and the sequence of concrete placement, which are important for the prevention of plastic shrinkage cracking, can be effectively planned using the introduced both equations without any rigorous analysis.

Application of High-Performance Steels to Enhance the Punching Shear Capacity of Two-Way Slabs (2방향 슬래브의 펀칭전단성능 향상을 위한 고성능 철근의 적용)

  • Yang, Jun Mo;Shin, Hyun Oh;Lee, Joo Ha;Yoon, Young Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.2
    • /
    • pp.161-169
    • /
    • 2011
  • Two-way slabs reinforced with high-performance steels, which have several practical advantages of a reduction of congestion in heavily reinforced members, savings in the cost of labor and repair, the higher corrosion resistance, and a reduction of construction time, were constructed and tested. The influences of the flexural reinforcement ratio, concentrating the reinforcement in the immediate column region, and using steel fiber-reinforced concrete (SFRC) in the slab on the punching shear resistance and post-cracking stiffness were investigated, and compared with the punching shear test results of the slabs reinforced with conventional steels and GFRP bars. In addition, the strain distribution of flexural reinforcements and crack control were investigated, and the effective width calculating method for the average flexural reinforcement ratio was estimated. The use of high-performance steel reinforcement increased the punching shear strength of slabs, and decreased the amount of flexural reinforcements. The concentrating the top mat of flexural reinforcement increased the post-cracking stiffness, and showed better strain distribution and crack control. In addition, the use of SFRC showed beneficial effects on the punching shear strength and crack control. It was suggest that the effective width should be changed to larger than 2 times the slab thickness from the column faces.

Effect on the Crack Resistance of Fiber Reinforced Concrete using Incinerated Paper Mill Sludge Ash (제지(製紙) 슬러지 소각재(燒却滓)를 활용(活用)한 섬유보강(纖維補强)콘크리트의 균열(龜裂) 억제(抑制) 효과(效果))

  • Kim, Nam-Wook
    • Resources Recycling
    • /
    • v.17 no.4
    • /
    • pp.10-20
    • /
    • 2008
  • This study was intended to use an incinerated paper mill sludge ash as cement alternatives in order to derive a method of utilizing the incinerated paper mill sludge ash of low utilization rate in large quantities. Also, the utilization possibility of incinerated paper mill sludge ash as the cement alternative was examined by mixing a polypropylene fiber and cellulose fiber and by considering its control effect for shrinkage cracks caused by an increase of absorption rate and hydration heat, as a weakness shown at the alternation of incinerated paper mill sludge ash.

Brittle rock property and damage index assessment for predicting brittle failure in underground opening (지하공동의 취성파괴 예측을 위한 암석물성 및 손상지수 평가)

  • Lee, Kang-Hyun;Bang, Joon-Ho;Kim, Jin-Ha;Kim, Sang-Ho;Lee, In-Mo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.11 no.4
    • /
    • pp.327-351
    • /
    • 2009
  • Laboratory tests are performed in this paper to investigate the brittle failure characteristics of over-stressed rocks taken in deep depth. Also, numerical simulation performed using that the so-called CWFS(Cohesion Weakening Frictional Strengthening) model is known to predict brittle failure phenomenon reasonably well. The most typical rock types of Korean peninsula - granite and gneiss - were used for testing. Results of uniaxial compression tests showed that the crack initiation stress was about 41 % to 42% of the uniaxial compressive strength regardless of rock types, where as, the crack damage stress of granite was about 75%, and that of gneiss was about 97%. Through the damage-controlled test, strength parameters of each rock were obtained as a function of damage degree. After the peak, the crack damage stress and the maximum stress were decreased, The cohesion was decreased and the friction angle was increased with increase of rock damage. Before reaching the peak, the elastic modulus was slightly increased, while decreased after the peak. Poisson's ratio was increased as the damage of rock proceeds. Comparison of uniaxial compression tests and damage-controlled tests shows the crack initiation stress estimated from the damage-controlled test fluctuated within the range of crack initiation stress obtained from the uniaxial compression test; the crack damage stress was less than that estimated from the uniaxial compression test. In order to predict the critical depth that brittle failure occurs, numerical simulations using the CWFS model were performed for an example site. Material parameters obtained from the laboratory tests mentioned above were used for CWFS simulation. Comparison between the critical depth predicted from the numerical simulation using the CWFS model and that predicted by using the damage index proposed by Martin et al.(l999), showed that critical depth cannot be reasonably predicted by the currently used damage index except for circular tunnels. A modified damage index was proposed by the author which takes the shape of tunnels other than circular into account.

An Enhanced Max-Min Neural Network using a Fuzzy Control Method (퍼지 제어 기법을 이용한 개선된 Max-Min 신경망)

  • Kim, Kwang-Baek;Woo, Young-Woon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.8
    • /
    • pp.1195-1200
    • /
    • 2013
  • In this paper, we proposed an enhanced Max-Min neural network by auto-tuning of learning rate using fuzzy control method. For the reduction of training time required in the competition stage, the method was proposed that arbitrates dynamically the learning rate by applying the numbers of the accuracy and the inaccuracy to the input of the fuzzy control system. The experiments using real concrete crack images showed that the enhanced Max-Min neural network was effective in the recognition of direction of the extracted cracks.

Characteristic of Microcracks with Mixing Proportional Properties of Concrete (미세균열이 콘크리트의 염소이온 침투에 미치는 영향 III; 배합조건 특성에 따른 미세균열의 특성)

  • Yoon, In-Seok;Kim, Young-Geun;Park, Ki-Bong
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.4
    • /
    • pp.469-475
    • /
    • 2008
  • It is obvious that chloride penetration through cracks can threaten the durability of concrete substantially, according to the previous studies of author. It was proposed that crack depth corrseponded with critical crack width from the surface is a crucial factor in view of durability design of concrete structures. It is now necessary to deal with chloride penetration through microcracks characterized with the mixing features of concrete. The purpose of this study is examining the effect of mix proportional features of concrete such as coarse aggregate, high strengtherize of concrete and reinforcement of steel fiber on chloride penetration through cracks. Although small size of coarse aggregate can lead to many microcracks in concrete, the cracks should not impact on chloride penetration directly. On the contrary, chloride should penetrate through cracks easily in concrete with a large size of coarse aggregate because mixrocracks are connected to each other. Second, high strength concrete has an excellent performance to resist with chloride penetration. However, for cracked high strength concrete, its performance is reduced upto the level of ordinary concrete. Finally, steel fiber reinforcement is effective to reduce chloride penetration through cracks because steel fiber reinforcement can lead to reduce crack depth significantly.

Reasonable Minimum Reinforcement for Crack Control of Concrete Shrinkage (콘크리트 건조수축 균열제어를 위한 합리적인 최소철근량)

  • 김수만;오민호
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.441-444
    • /
    • 1999
  • The crack width of concrete structures subjected to shrinkage depend on a great number of parameters whose effects are restrain condition, the number and spacing of crack and the amounts of reinforcements. Through suitable reinforcement it is possible to make the individual cracks exceedigly small. This paper is to present the amount of reasonable reinforcement for crack control through a rational analysis of forces occuring in significantly restrained concrete structures due to the shrinkage. Also the analysis results from this paper are compared with the provisions for shrinkage and temperture reinforcement in the KCI concrete strucural design code.

  • PDF

Crack Control of the Precast Decks in Negative Moment Region using External Tendon (외부강선을 이용한 부모멘트부 바닥판의 균열제어)

  • 김영신;정철헌;홍민기;박세진;김철영;이병주
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.291-296
    • /
    • 2002
  • In order to apply precast decks to the continuous composite bridges, several experiments and analytical studies were performed. For the continuous composite bridges, special attention should be paid to the transverse joints in negative moment region. Judging from the results, combination of longitudinal internal prestressing tendon and the external tendon can be effectively used for the prevention of cracking in the negative moment region of precast decks.

  • PDF

Control of Crack and Enhanced Durability Performance of Face Slab Concrete (차수벽 콘크리트의 균열제어 및 성능향상에 관한 연구)

  • 임정열;정우성;김완영;원종필
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.537-540
    • /
    • 2003
  • The effects of substituting cement with fly ash(10%, 15%, 20%) and different fiber addition(polypropylene, cellulose, poly vinyl alcohol), on the control of microcrack and enhanced durability performance of face slab concrete in CFRD was studied experimentally It was conducted experiments of plastic shrinkage of mortar and concrete, and drying shrinkage of concrete. Also, durability test were carried out the chloride permeability, abrasion resistance and freeze-thaw repetition. Through the experimental results, it was concluded that ploy vinyl alcohol fiber containing concrete was the most effective mixture in control of cracking and durability.

  • PDF