• Title/Summary/Keyword: 균열저항

Search Result 543, Processing Time 0.036 seconds

A Study on Corrosion Potential of Cracked Concrete Beam According to Corrosion Resistance Assessment (부식 저항성 평가에 따른 균열 콘크리트 보의 부식전위 연구)

  • Song, Ha-Won;Lee, Chang-Hong;Lee, Kewn-Chu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.1 s.53
    • /
    • pp.97-105
    • /
    • 2009
  • Development and use of blended cement concrete is gaining more importance in the construction industry with reference to durability mainly due to the pore refinement and reduction in permeability. Cracks play a major role on important parameters like permeability, rate of chloride ingress, compressive strength and thus affect the reinforcement corrosion protection. Furthermore, when a crack occurs in the cover concrete, the corrosion of the steel reinforcement may be accelerated because the deterioration causing factors can pass through the crack. In recent years the effect of cracking on the penetration of concrete has been the subject of numerous investigations. Therefore assessing the service life using blended concrete becomes obviously in considering the durability. In the present study, the corrosion assessment of composite concrete beams with and without crack with of 0.3mm using OPC, 30% PFA, 60% GGBS, 10% SF was performed using half cell potential measurement, galvanic potential measurement, mass loss of steel over a period of 60days under marine environmental conditions and the results were discussed in detail.

An Analysis of Crack Growth Rate Due to Variation of Fatigue Crack Growth Resistance (피로균열전파저항의 변동성에 의한 균열전파율의 해석)

  • Kim, Seon-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.23 no.7 s.166
    • /
    • pp.1139-1146
    • /
    • 1999
  • Reliability analysis of structures based on fracture mechanics requires knowledge on statistical characteristics of the parameter C and m in the fatigue crack growth law, $da/dN=C({\Delta}K)^m$. The purpose of the present study is to investigate if it is possible to predict fatigue crack growth rate by only the fluctuation of the parameter C. In this study, Paris-Erdogan law is adopted, where the author treat the parameter C as random and m as constant. The fluctuation of crack growth rate is assumed only due to the parameter C. The growth resistance coefficient of material to fatigue crack growth (Z=1/C) was treated as a spatial stochastic process, which varies randomly on the crack path. The theoretical crack growth rates at various stress intensity factor range are discussed. Constant ${\Delta}K$ fatigue crack growth tests were performed on the structural steel, SM45C. The experimental data were analyzed to determine the autocorrelation function and Weibull distributions of the fatigue crack growth resistance. And also, the effect of the parameter m of Paris' law due to variation of fatigue crack growth resistance was discussed.

The Formation of Serrated Grain Boundaries and Its Influence on Boron Segregation and Liquation Behavior (파형 결정립계 생성이 보론 편석 및 액화거동에 미치는 영향)

  • Hong, H.U.;Kim, I.S.;Choi, B.G.;Yoo, Y.S.;Jo, C.Y.
    • Proceedings of the KWS Conference
    • /
    • 2010.05a
    • /
    • pp.73-73
    • /
    • 2010
  • 합금원소가 다량 첨가된 고합금강, 스테인리스강, Ni기 초내열합금 등은 용접시 혹은 후열처리 동안 열영향부 (HAZ: heat-affected-zone)에서 결정립계를 따라서 액화균열이 종종 발생한다. 이러한 액화균열은 급속한 가열시 HAZ의 결정립계가 국부적으로 용융되어 액상필름을 형성하고, 냉각시 수축으로 인한 인장구속응력에 의해 필름을 따라서 균열이 발생하여 생성된다. HAZ 결정립계 액화는 탄화물, 황화물, 인화물, 보론계 화합물 등이 급가열시 기지와의 반응에 의해 표피 액상을 형성하는 조성적 액화 (constitutional liquation)에 의한 액상의 결정립계 침투로 설명되거나, 결정립계 자체의 용융점을 상당량 낮추는 보론(B), 인(P), 황(S)등의 편석에 의한 국부적 입계 용융으로 주로 연관 지어 해석한다. HAZ 액화균열은 고온 입계균열 현상이므로, 결정립계의 특성에 따라 크게 영향을 받으며 결정립계 character 설계에 의해 액화균열 저항성을 개선시킬 수 있음을 유추할 수 있다. 한편, 본 연구자들은 최근 Ni기 초내열합금에 있어 입계 serration 현상을 새롭게 발견하였으며, 이론적 접근법을 통해 serration을 위한 특별한 열처리 방법을 개발하였다. 형성된 파형입계는 결정학적인 관점에서 조밀 {111} 입계면을 갖도록 분해 (dissociation)되어 낮은 계면에너지를 갖게 됨을 확인하였으며, 입계형상 변화뿐만 아니라 탄화물 특성변화까지 유도하여 크리프 수명을 기존대비 약 40% 정도 향상시킴을 확인하였다. 본 연구에서는 이러한 직선형 입계 대비 'special boundary'로 간주되는 파형입계가 도입될 경우, 보론 편석 및 HAZ 액화거동에 미치는 영향을 고찰하고자 하였다. SIMS (secondary ion mass spectrometry)를 이용하여 열처리 직후 결정립계 보론편석 정도를 비교하였다. 파형입계 시편의 경우, 일반직선형 시편에 비해 결정립계에 보론편석 저항성이 우수함을 확인할 수 있었다. 재현 HAZ 열사이클 시험을 통해 미세조직을 정량적으로 분석하였다. 파형입계 시편 및 일반직선형 시편 모두 최고온도 $1060^{\circ}C$이상부터 입계 탄화물이 기지내로 완전 용해되고 입계가 액화되기 시작하였다. 최고온도별로 입계액화비율을 정량적으로 비교한 결과, 파형입계가 직선입계 대비 훨씬 낮음을 확인할 수 있었으며, 때때로 액화된 필름이 입계를 따라 전파되지 않고 부분적으로 단락되어 있음이 관찰되었다. 액화시험 후 투과전자현미경을 이용한 EDS (energy dispersive spectrometry) 분석을 통해 결정립계 액화의 주요원인은 입계 $M_{23}C_6$의 조성적 액화반응 보다는 보론 편석 (원자 및 $M_{23}(CB)_6$)으로 인한 결정립계 국부용융이 더 유력함을 유추할 수 있었다. 따라서 상기 결과로부터 입계구조가 안정되어 계면에너지가 낮은 파형입계가 보론편석에 대한 저항성이 우수하였으며, 이러한 결과는 액화 저항성에 대응되어 영향을 미침을 알 수 있었다. 게다가 파형입계에 액상 필름이 생성되더라도 낮은 계면에너지에 의해 비롯된 상대적으로 낮은 적심성 (wettability)에 의해 필름이 쉽게 전파되지 않음을 'Smith 입계 wetting 이론'을 이용하여 해석할 수 있었다.

  • PDF

Shear Resistance of Unreinforced Cast-In-Place Anchors in Uncracked and Cracked Concrete by Seismic Qualification Tests (지진모의실험에 의한 비균열 및 균열콘크리트에 매입된 비보강 선설치앵커의 전단 저항강도 평가)

  • Park, Yong Myung;Kim, Tae Hyung;Kim, Dong Hyun;Jo, Sung Hoon;Lee, Jong Han
    • Journal of Korean Society of Steel Construction
    • /
    • v.27 no.3
    • /
    • pp.347-357
    • /
    • 2015
  • In this study, an experimental study was performed to evaluate the concrete breakout strength of unreinforced cast-in-place anchors by seismic qualification test under shear loading. The CIP anchors tested herein were 30mm in diameter with an edge distance of 150mm and an embedment depth of 240mm in uncracked and cracked concrete. The cracked specimen consisted of orthogonal and parallel crack to the loading direction, respectively. The dynamic loading sequence during the seismic qualification test was determined based on CSA N287.2, ACI 355.2 and ETAG 001 codes. After the dynamic loading, the static loading was applied until failure occurs. The shear resistance by seismic qualification tests showed almost the same strength as that obtained from the static tests in uncrcaked and cracked concrete, respectively. Meanwhile, the breakout depth did not reach $8d_0$, therefore the modified strength equation of ACI 318-11 could estimate properly the concrete breakout strength, which does not consider effective bearing length.

DCPD법에의한 316LN 스테인레스강의 고온 피로균열진전특성

  • Maeng, Wan-Young;Nam, Ho-Yun;Kang, Young-Hwan;Cho, Man;Kim, Mun-Hwan;Kwon, Hyuk-Mu;Nam, Tae-Woon
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.05b
    • /
    • pp.36-41
    • /
    • 1997
  • 액체금속로는 고온 하중 효과(피로, 크립, 크립-피로)를 고려한 내열응력설계가 중요하다. 최근에는 액금로 후보재료로서 종래의 스테인레스강에 질소를 첨가하여 고온강도를 계량한 316LN 스테인레스강이 개발되었다. 본 연구에서는 액체금속로 재료의 가장 지배적인 손상 기구로 인식되고 있는 피로-크립 파손에 대한 설계자료를 확보하기 위해 DCPD(Direct Current Potential Drop)법에 의한 고온피로균열 측정 시스템을 개발하고 316L 및 스테인레스강인 316LN 스테인레스강에 대한 고온 피로균열진전시험을 수행하였다. 본 연구에 의해 개발된 피로균열진전속도 측정 시스템에 의하면 25$\mu\textrm{m}$ 이하의 분해능으로 균열길이를 측정할 수 있다. 한편 316L 스테인레스강에 질소를 적당량 첨가하면 상온에서 $600^{\circ}C$사이의 온도에서 피로균열진전에 대한저항성이 증가하는 것을 확인하였다.

  • PDF

The Improvement of Electrical Characteristics of Inkjet-printed Cu films with Stress Relaxation during Thermal Treatment (잉크젯 프린팅된 Cu 박막의 응력해소를 통한 전기적 특성 개선)

  • Yi, Seol-Min;Joo, Young-Chang
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.21 no.4
    • /
    • pp.57-62
    • /
    • 2014
  • Using flexible bismaleimide-triazine co-polymer as a substrate, inkjet-printed Cu films were also investigated for low-cost and process feasibility of flexible electronics. After annealing at $200^{\circ}C$ for 1 h under various reducing ambient, surface color was changed to red and electrical resistivity was decreased to the level of conductor under formic acid ambient. However, its resistivity was much higher than conventional copper films due to surface crack. In order to reduce the residual film stress after annealing, additional isothermal treatment was inserted before anneal hiring the stress relaxation applied in processes of amorphous materials. As a result, no surface crack was observed and electrical resistivity of $3.4{\mu}{\Omega}cm$ was measured after annealing at $230^{\circ}C$ with stress relaxation while electrical resistivity of $7.4{\mu}{\Omega}cm$ was observed after normal annealing without relaxation. The effect of stress relaxation was also confirmed by observing surface crack after decreasing the relaxation time to 0 min.

Flexural Performance and Cracking Resistance of Continuous Composite Slab using Micro Steel Fibers (마이크로 강섬유 콘크리트를 적용한 연속 합성슬래브의 휨 및 균열 저항성능)

  • Hwang, Hyeon-Jong;Park, Hong-Gun;Hong, Geon-Ho;Kim, Gap-Deug;Choi, Se-Jin
    • Journal of the Korea Concrete Institute
    • /
    • v.27 no.4
    • /
    • pp.387-397
    • /
    • 2015
  • In the present study, to enhance the constructability, a composite slab system using deck plate and micro steel fiber concrete was studied. In the proposed slab system, on-situ re-bar placement is not required. Steel fibers replace the temperature reinforcement. The present study focused on the crack control at the slab top in the continuous composite slab without spliced bars. Eight continuous slabs with various parameters were tested under vertical loading. The test parameters were the amount and types of micro steel fibers, types of deck plate, and the use of top bars in the continuous slab. To evaluate the crack resistance of the slabs, crack widths were measured in the continuous slabs. The test results showed that although the top spliced bars were not used, cracking were restrained by large flexural stiffness of the composite sections.

The Effect Of Electrical Output Of PV Module According to Mechanical Stress (기계적 스트레스가 태양전지모듈의 전기적 출력에 미치는 영향)

  • Kong, Ji-Hyun;Ji, Yang-Geun;Kang, Gi-Hwan;Kim, Kyung-Su;Jung, Tae-Hee;Shin, Jun-Oh;Kim, Tae-Bum;Yu, Gwon-Jong;Ahn, Hyung-Guen;Han, Deuk-Young
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1126_1127
    • /
    • 2009
  • 태양전지모듈에 물리적 하중이 가해지면 전면유리의 연신율에 따라 모듈이 휘어지게 되고 이에 따라 내부에 열 봉합되어 있는 태양전지에 미세한 균열이 발생한다. 이 균열이 태양전지모듈의 단락전류 및 개방전압의 출력을 떨어뜨리는데 이는 균열로 인한 저항성분의 증가로 인한 것이다. 모듈내의 특정한 셀에서 미세균열(Micro-crack)의 발생은 출력의 저하, 셀 출력 Mismatch로 인한 모듈 내의 Hot-Spot발생, 균열로 인한 저항성분으로서의 열 발생과 같은 전체 태양전지모듈의 내구성을 저하시키는 요소로 작용한다. 본 연구에서는 결정질 태양전지 모듈의 출력에 영향을 미치는 요소 가운데 기계적 스트레스에 의한 미세균열(Micro-crack)이 전기적 출력에 미치는 영향에 대해 본 논문에서 알아보고자 한다.