• Title/Summary/Keyword: 권고기준

Search Result 429, Processing Time 0.028 seconds

Sugar Contents Analysis of Retort Foods (레토르트식품에 함유되어 있는 당 함량 분석)

  • Jeong, Da-Un;Im, Jun;Kim, Cheon-Hoe;Kim, Young-Kyoung;Park, Yoon-Jin;Jeong, Yoon-Hwa;Om, Ae-Son
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.44 no.11
    • /
    • pp.1666-1671
    • /
    • 2015
  • The purpose of this study was to provide trustworthy nutritional information by analyzing sugar contents of commercial retort foods. A total of 70 retort food samples were collected, which included curry (n=21), blackbean- sauce (n=16), sauce (n=17), and meat (n=16) from markets in Seoul and Gyeonggi-do. Contents of sugars such as glucose, fructose, sucrose, maltose, and lactose were analyzed in retort foods by using a high performance liquid chromatography-refractive index detector and compared to their assigned values on nutritional information labels. Analyzed sugar contents of curries, black-bean-sauces, sauces, and meats ranged from 1.05~4.63 g/100 g, 1.76~5.16 g/100 g, 0.35~25.44 g/100 g, and 1.98~11.07 g/100 g, respectively. Sauces were found to contain the highest amounts of total sugar. These analysis values were equivalent to the reference values indicated on nutrition labels, which were 40~119.5% for curries, 29~118% for black-bean-sauces, 18~118% for sauces, and 70~119.8% for meats. Therefore, this study provides reliable analytical values for sugar contents in retort foods.

Salinity Monitoring of Soups of The Institutions Enrolled at Center for Children's Foodservice Management (어린이급식관리지원센터 등록 시설 국물음식의 염도 모니터링)

  • Park, Hyun Nae;Kim, Soon Mi
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.26 no.6
    • /
    • pp.507-516
    • /
    • 2016
  • The salinity of soups of institutions enrolled at the Center for Children's Foodservice Management was monitored to reduce sodium intake of children by continuously managing salinity of soups provided by children food service. Monitoring of salinity was conducted by a salinity meter (SB-1500H, HM digital) three times in 2016 by patrolling children's institutions for the instruction of public health. The average salinity of soups provided by total children's institution showed a significant decrease in salinity - $1^{st}$ 0.45%, $2^{nd}$ 0.41% and $3^{rd}$ 0.39% - as monitoring was proceeded (p<0.01). When salinity of soups was analyzed according to the type of children's institution, the salinity of national and public institutions showed no significant decrease. In contrast, the salinity of private institutions decreased significantly (p<0.05). Depending on the enrollment of the food service, there was no significant difference in average salinity of soups between large food services, which have over 50 children, and small food services, which have less than 50 children. However, all food services showed a salinity decrease from the $1^{st}$ monitoring to the $3^{rd}$ monitoring. Salinity according to the type of soup showed that salinity of clear soup, miso soup, and stew except beef soup decreased from the $1^{st}$ monitoring to $3^{rd}$ monitoring. However, there was no significant difference in salinity according to the type of soup which can be attributed to a large difference in salinity among the same type of soup. The individual soup showing the biggest difference between maximum and minimum salinity of soup was egg soup (0.62%), potato soup (0.54%), and mushroom soup (0.64%). The present average salinity of soup provided by children's institutions was less than 0.5% which is the recommended standard of the Ministry of Food and Drug Safety. However, the salinity of soups should be managed within a certain range including the minimum salinity regarding the taste education of children.

Evaluation on Organ Dose and Image Quality of Lumbar Spine Radiography Using Glass Dosimeter (유리선량계를 이용한 요추검사의 장기선량 및 영상의 평가)

  • Kim, Jae-Kyeom;Kim, Jeong-Koo
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.1-11
    • /
    • 2016
  • The purpose of this study was to provide resources for medical exposure reduction through evaluation of organ dose and image resolution for lumbar spine around according to the size of the collimator in DR system. The size of the collimator were varied from $8^{\prime\prime}{\times}17^{\prime\prime}$ to $14^{\prime\prime}{\times}17^{\prime\prime}$ by 1" in AP and lateral projection for the lumbar spine radiography with RANDO phantom. The organ dose measured for liver, stomach, pancreas, kidney and gonad by the glass dosimeter. The image resolution was analyzed using the Image J program. The organ dose of around lumbar spine were reduced as the size of the collimator is decreased in AP projection. There were no significant changes decreasing rate whenever the size of the collimator were reduced 1" in the gonad. The organ dose showed higher on liver and kidney near the surface in lateral projection. There were decreasing rate of less than 5% in liver and kidney, but decreasing rate was 24.34% in the gonad whenever the size of the collimator were reduced 1". Organ dose difference for internal and external of collimator measured $549.8{\mu}Gy$ in the liver and $264.6{\mu}Gy$ in the stomach. There were no significant changes organ dose difference that measured $1,135.1{\mu}Gy$ in the gonad. Image Quality made no difference because SNR and PSNR were over than 30 dB when the collimator size is less than $9^{\prime\prime}{\times}17^{\prime\prime}$ on AP projection and $10^{\prime\prime}{\times}17^{\prime\prime}$ on lateral projection. Therefore, we are considered that the recommendations criterion for control of collimator were suggested in order to reduce unnecessary X-ray exposure and to obtain good image quality because lumbar spine radiography contains a lot of peripheral organs rather than other area radiography.

Development of NQ-E, Nutrition Quotient for Korean elderly: item selection and validation of factor structure (노인 대상 영양지수 개발 : 평가항목 선정과 구성 타당도 검증)

  • Chung, Min-Jae;Kwak, Tong-Kyung;Kim, Hye-Young;Kang, Myung-Hee;Lee, Jung-Sug;Chung, Hae Rang;Kwon, Sehyug;Hwang, Ji-Yun;Choi, Young-Sun
    • Journal of Nutrition and Health
    • /
    • v.51 no.1
    • /
    • pp.87-102
    • /
    • 2018
  • Purpose: The purpose of this study was to develop a valid instrument for measuring the dietary quality and behaviors of Korean elderly. Methods: The development of the Nutrition Quotient for Elderly (NQ-E) was conducted in three steps: item generation, item reduction, and validation. The 41 items of the NQ-E checklist were derived from a systematic literature review, expert in-depth interviews, statistical analyses of the fifth Korean National Health and Nutrition Examination Survey data, and national nutrition policies and recommendations. Pearson's correlation was used to determine the level of agreement between the questionnaires and nutrient intake level, and 24 items were selected for a nationwide survey. A total of 1,000 nationwide elderly subjects completed the checklist questionnaire. The construct validity of the NQ-E was assessed using confirmatory factor analysis, LISREL. Results: The nineteen checklist items were used as final items for NQ-E. Checklist items were composed of four-factors: food behavior (6 items), balance (4 items), diversity (6 items), and moderation (3 items). The standardized path coefficients were used as the weights of the items. The NQ-E and four-factor scores were calculated according to the obtained weights of the questionnaire items. Conclusion: NQ-E would be a useful tool for assessing the food behavior and dietary quality of the elderly.

An Optimization Method of Measuring Heart Position in Dynamic Myocardial Perfusion SPECT with a CZT-based camera (동적 심근관류 SPECT에서 심장의 위치 측정방법에 대한 고찰)

  • Seong, Ji Hye;Lee, Dong Hun;Kim, Eun Hye;Jung, Woo Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.75-79
    • /
    • 2019
  • Purpose Cadmium-zinc-telluride (CZT) camera with semiconductor detector is capable of dynamic myocardial perfusion SPECT for coronary flow reserve (CFR). Image acquisition with the heart positioned within 2 cm in the center of the quality field of view (QFOV) is recommended because the CZT detector based on focused multi-pinhole collimators and is stationary gantry without rotation. The aim of this study was to investigate the optimal method for measuring position of the heart within the center of the QFOV when performing dynamic myocardial perfusion SPECT with the Discovery NM 530c camera. Materials and Methods From June to September 2018, 45 patients were subject to dynamic myocardial perfusion SPECT with D530c. For accurate heart positioning, the patient's heart was scanned with a mobile ultrasound and marked at the top of the probe where the mitral valve (MV) was visible in the parasternal long-axis view (PLAX). And, the marked point on the patient's body matched with the reference point indicated CZT detector in dynamic stress. The heart was positioned to be in the center of the QFOV in rest. The coordinates of dynamic stress and rest were compared statistically. Results The coordinates of the dynamic stress using mobile ultrasound and those taken of the rest were recorded for comparative analysis with regard to the position of the couch and analyzed. There were no statistically significant differences in the coordinates of Table in & out, Table up & down, and Detector in & out (P > 0.05). The difference in distance between the 2 groups was measured at $0.25{\pm}1.00$, $0.24{\pm}0.96$ and $0.25{\pm}0.82cm$ respectively, with no difference greater than 2 cm in all categories. Conclusion The position of the heart taken using mobile ultrasound did not differ significantly from that of the center of the QFOV. Therefore, The use of mobile ultrasound in dynamic stress will help to select the correct position of the heart, which will be effective in clinical diagnosis by minimizing the image quality improvement and the patient's exposure to radiation.

Revision of Nutrition Quotient for Elderly in assessment of dietary quality and behavior (식사의 질과 식행동 평가를 위한 노인영양지수 개정 연구)

  • Lim, Young-Suk;Lee, Jung-Sug;Hwang, Ji-Yun;Kim, Ki-Nam;Hwang, Hyo-Jeong;Kwon, Sehyug;Kim, Hye-Young
    • Journal of Nutrition and Health
    • /
    • v.55 no.1
    • /
    • pp.155-173
    • /
    • 2022
  • Purpose: This study was undertaken to update the Nutrition Quotient for Elderly (NQ-E), which reflects dietary quality and behavior among Korean older adults. Methods: The first 29 items of the measurable food behavior checklist were obtained from a previous NQ-E checklist, recent literature reviews, and national nutrition policies and recommendations. One-hundred subjects (50 men and 50 women) aged ≥ 65 years living in the Seoul Metropolitan Area, including Gyeonggi Province, completed a pilot survey from March to April 2021. Based on the results of the pilot study, we conducted factor analysis and frequency analysis to determine whether the items of the survey were properly organized and whether the distribution of answers for each evaluation item was properly distributed. As a result, we reduced the number of items on the food behavior checklist and used 23 items for the national survey. Nationwide, 1,000 subjects (472 men and 528 women) aged > 65 years, completed the checklist survey, which was applied using a face-to-face survey method from May to August 2021. The construct validity of the NQ-E 2021 was assessed using confirmatory factor analysis, LISREL. Results: Seventeen food behavior checklist items were selected for the final NQ-E 2021. Checklist items addressed three factors: balance (8 items), moderation (2 items), and practice (7 items). Standardized path coefficients were used as the weights of items to determine nutrition quotients. NQ-E and three-factor scores were calculated according to the weights of questionnaire items. Conclusion: The updated NQ-E 2021 produced by structural equation modelling provides a suitable tool for assessing the dietary quality and behavior of Korean older adults.

Monitoring and risk assessment of 1,4-Dioxane in Nakdong river (낙동강 수계 중 1,4-dioxane의 모니터링 및 위해성 평가)

  • Lee, Ji-Young;Kim, Joung-Hwa;Kim, Hyun-Koo;Choi, Jong-Ho;Kim, Seungki;Pyo, Heesoo
    • Analytical Science and Technology
    • /
    • v.21 no.5
    • /
    • pp.383-391
    • /
    • 2008
  • International Agency for Research on Cancer (IARC) has classified it as a possible carcinogen and World Health Organization (WHO) has suggested 50 ng/mL as a guideline value for 1,4-dioxane. Considering the toxicity of 1,4-dioxane and ingestion rate of drinking water, the monitoring of 1,4-dioxane in drinking water in Nakdong river is very important. We analyzed 1,4-dioxane four times per year for the 12 samples of treated water and 4 samples of raw water in Nakdong river in Korea from 2000 to 2007 and surveyed the trend of concentrations of 1,4-dioxane. As a results of analysis, 1,4-dioxane was detected from 0.24 to 240.2 ng/mL in treated water and from 0.39 to 81.9 ng/mL in raw water from 2000 to 2007. The average concentrations are 22.68 ng/mL and 19.15 ng/mL in treated water and raw water, respectively. The detected concentrations was decreased but frequency of detection was not changed since establishment of regulation in 2004. Results of comparison of 95 percentile excessive cancer risk of 1,4-dioxane in treated and raw water were each $6.63{\times}10^{-6}$, $3.17{\times}10^{-6}$ before 2004 and $2.10{\times}10^{-6}$, $1.22{\times}10^{-6}$ after 2004. Also, comparing the detected concentration and frequency for each season, these were more detected the concentration and frequency for 1,4-dioxane in treated and raw water from winter to spring.

The Effect of Recombinant Human Epidermal Growth Factor on Cisplatin and Radiotherapy Induced Oral Mucositis in Mice (마우스에서 Cisplatin과 방사선조사로 유발된 구내염에 대한 재조합 표피성장인자의 효과)

  • Na, Jae-Boem;Kim, Hye-Jung;Chai, Gyu-Young;Lee, Sang-Wook;Lee, Kang-Kyoo;Chang, Ki-Churl;Choi, Byung-Ock;Jang, Hong-Seok;Jeong, Bea-Keon;Kang, Ki-Mun
    • Radiation Oncology Journal
    • /
    • v.25 no.4
    • /
    • pp.242-248
    • /
    • 2007
  • Purpose: To study the effect of recombinant human epidermal growth factor (rhEGF) on oral mucositis induced by cisplatin and radiotherapy in a mouse model. Materials and Methods: Twenty-four ICR mice were divided into three groups-the normal control group, the no rhEGF group (treatment with cisplatin and radiation) and the rhEGF group (treatment with cisplatin, radiation and rhEGF). A model of mucositis induced by cisplatin and radiotherapy was established by injecting mice with cisplatin (10 mg/kg) on day 1 and with radiation exposure (5 Gy/day) to the head and neck on days $1{\sim}5$. rhEGF was administered subcutaneously on days -1 to 0 (1 mg/kg/day) and on days 3 to 5 (1 mg/kg/day). Evaluation included body weight, oral intake, and histology. Results: For the comparison of the change of body weight between the rhEGF group and the no rhEGF group, a statistically significant difference was observed in the rhEGF group for the 5 days after day 3 of. the experiment. The rhEGF group and no rhEGF group had reduced food intake until day 5 of the experiment, and then the mice demonstrated increased food intake after day 13 of the of experiment. When the histological examination was conducted on day 7 after treatment with cisplatin and radiation, the rhEGF group showed a focal cellular reaction in the epidermal layer of the mucosa, while the no rhEGF group did not show inflammation of the oral mucosa. Conclusion: These findings suggest that rhEGF has a potential to reduce the oral mucositis burden in mice after treatment with cisplatin and radiation. The optimal dose, number and timing of the administration of rhEGF require further investigation.

Packing effects on the intracavitary radiation Therapy 3-Dimension plan of the uterine cervix cancer (자궁경부암 강내조사 3차원 치료계획 시 Packing의 유용성 분석)

  • Si, Chang-Keun;Jo, Jung-Kun;Lee, Du-Hyun;Kim, Sun-Yeung;Kim, Tae-Yoon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.1
    • /
    • pp.1-8
    • /
    • 2005
  • Purpose : An effect of a packing to uterine treatment of a cervical cancer using a dose-volume histogram for a point dose and a volume dose of the bladder and the rectum was analyzed by establishing a three-dimensional treatment plan using a CT image. Materials and methods : Reference points of the bladder and the rectum were marked, respectively at a treatment plan device (plato brachytherapy V14.2.4) by photographing CT(marconi, USA) when the packing was used and removed under the same condition and a treatment plan was performed to Apoint depending on ICRU38. However, in case of the rectum, a maximum point was looked up and compared with the above point because the point presented from the ICRU is not proper as a representative value of a rectum point dose. Further, the volume dose depending on volume of $50\%,\;80\%,\;and\;100\%$ point doses of the rectum and the bladder was measured. The measured values were used to analyze the effect of the packing through a Wilcoxon Signed Rank Test (a SAS statistical analysis process program). Result : The reference points at the bladder and rectum doses when the packing was removed were $116.94\;35.42\%$ and $117.59\;21.08\%$, respectively. The points when the packing was used were $107.08\;38.12\%$ and $95.19\;21.32\%$, respectively. After the packing was used, the reference points at the bladder and the rectum were decreased by $9.86\%$ and $22.4\%$, respectively. When the packing was removed, the maximum points at the bladder and the rectum were $164.51\;50.89\%,\;128.81\;33.05\%$, respectively. When the packing was used, the maximum points at the bladder and the rectum were $142.31\;44.79,\;110.08\;37.03\%$, respectively. After the packing was used, the maximum points at the bladder and the rectum were decreased by $22.2\%$ and $18.73\%$, respectively. When the packing was removed, the bladder volume at $50\%,\;80\%,\;and\;100\%$ point doses of the rectum and the bladder were $48.62{\pm}18.09\%,\;16.12{\pm}11.15\%,\;and\;7.51{\pm}6.63\%$, respectively and its rectum volume were $23.41{\pm}14.44\%,\;6.27{\pm}4.28\%,\;2.79{\pm}2.27\%$, respectively. When the packing was used, the bladder volume at $50\%,\;80\%,\;and\;100\%$ point doses of the rectum and the bladder were $40.33{\pm}16.72,\;11.63{\pm}8.72,\;and\;4.87{\pm}4.75\%$, respectively and its rectum volume were $18.96{\pm}8.37\%,\;4.75{\pm}2.58\%,\;and\;1.58{\pm}1.06\%$, respectively. After the packing was used, the bladder volume at $50\%,\;80\%,\;and\;100\%$ point doses of the rectum and the bladder were decreased by $8.29\%,\;4.49\%,\;and\;2.64\%$, respectively and its bladder volume were decreased by $4.45\%,\;1.52\%,\;and\;1.21\%$, respectively. Conclusion : Values at Reference point doses of the bladder and the rectum recommended from the ICRU 38 were 0.0781 and 0.0781, respectively and values of their maximum point doses were 0.0156 and 0.0156, respectively, as a result of which an effect of the packing using at the uterine intracavitary treatment of an uterine cervical cancer through the three-dimensional treatment plan used CT were measured. That is, the values at reference point doses and the values at maximum point doses show similar difference. However, P value was 0.15 at over $50\%,\;80\%,\;and\;100\%$ volume doses and the value shows no similar difference. In other words, the effect of the packing looks like having a difference at the point dose, but actually shows no difference at the volume dose. The reason is that the volume of the bladder and the rectum are wide but the volume of the packing is only a portion. Therefore, the effect of decreasing the point dose was not great. Further, the farer the distance is, the more weak the intensity of radiation is because the intensity of radiation is proportional to inverse square of a distance. Therefore, the effort to minimize an obstacle of the bladder and the rectum by using the packing should be made.

  • PDF