• Title/Summary/Keyword: 굽힘제한

Search Result 30, Processing Time 0.027 seconds

Characteristic Validation of High-damping Printed Circuit Board Using Viscoelastic Adhesive Tape (점탄성 테이프를 적용한 고댐핑 적층형 전자기판의 기본 특성 검증)

  • Shin, Seok-Jin;Jeon, Su-Hyeon;Kang, Soo-Jin;Park, Sung-Woo;Oh, Hyun-Ung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.5
    • /
    • pp.383-390
    • /
    • 2020
  • Wedge locks have been widely used for spaceborne electronics for mounting or removal of a printed circuit board (PCB) during integration, test and maintenance process. However, it can basically provide a mechanical constraint on the edge of the board. Thus, securing a fatigue life of solder joint for electronic package by limiting board deflection becomes difficult as the board size increases. Previously, additional stiffeners have been applied to reduce the board deflection, but the mass and volume increases of electronics are unavoidable. To overcome the aforementioned limitation, we proposed an application of multi-layered PCB sheet with viscoelastic adhesive tapes to implement high-damping capability on the board. Thus, it is more advantageous in securing the fatigue life of package under launch environment compared with the previous approach. The basic characteristics of the PCB with the multi-layered sheet was investigated through free-vibration tests at various temperatures. The effectiveness of the proposed design was validated through launch vibration test at qualification level and fatigue life prediction of electronic package based on the test results.

Flexibility of resin splint systems for traumatized teeth (외상성 치아모형에서의 레진 스플린트 시스템의 유연성 비교연구)

  • Park, Jin-Hong;Shin, Joo-Hee;Ryu, Jae-Jun;Lee, Jeong-Yol;Shin, Sang Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.4
    • /
    • pp.389-393
    • /
    • 2017
  • Purpose: The aim of this study is to evaluate the flexural strength of flexible resins and the flexibility of different resin splint (RS) systems in comparison with resin wire splint (RWS) system. Materials and methods: Three different resin materials (G-aenial flo, GA, GC; Superbond, SB, Sun medical; G-fix, GF, GC) were tested flexural strength test in accordance with ISO-4049:2000. For the flexibility test of splint systems, a artificial model with resin teeth was used to evaluate three types of resin splint systems (GA, SB, and GF) and one resin wire splint system. The left central incisor was simulated 'injured teeth' with third degree mobility. Three consecutively repeated measurements of periotest value were taken in horizontal direction, before and after splinting to access tooth mobility. The splinting effect was calculated through the periotest value. Differences were evaluated through One-way Anova and Tukey HDS post-hoc tests for pair-wise comparison (${\alpha}=.05$). Results: Although GA group showed significant higher flexural strength than SB and GF groups, all of three different resin splint systems produced a significantly higher and rigid splinting effect compared with 016" resin-wire splint system (P < .05). Conclusion: Within the limits of an in vitro study, it can be stated that resin splint systems are too rigid and may not be acceptable to treat tooth avulsion.

The Effect of SNAGs and Biofeedback Training on the Integrative Propriocepcion and Function of the Patients with Cervical Disorder (목의 기능장애 환자들에게 SNAGs기법과 바이오피드백 훈련이 통합적 고유수용성 감각과 목의 기능에 미치는 효과)

  • Lee, Eun Sang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.1
    • /
    • pp.284-290
    • /
    • 2020
  • This study was undertaken to determine the effects of SNAGs (sustained natural apophyseal glides) and visual convergence biofeedback on the proprioception and neck disability of patients with chronic neck dysfunction. A total of 31 patients with neck dysfunction were assigned to either SNAGs (n = 16) or biofeedback (n = 15). The groups were assessed for proprioception and neck disability, before and after the intervention. The SNAGs were performed using belt with flexion, extension and right-left rotation, whereas biofeedback training included visual feedback training with deep neck flexor. Intervention was implemented for 20 minutes, twice a week for 4 weeks. Biofeedback training a showed significant effect on the joint position sense (left and right rotation) as compared to the SNAGs group (p< 0.05), whereas neck disability index was significantly effective for SNAGs (p< 0.05). Ed. Notes: The previous statement lacked clarity. I have suggested the edit as per my understanding. Please review and revise appropriately, if required. Therefore, the SNAGs technique is effective for neck function, and biofeedback training is a positive intervention method for enhancing the proprioceptive sensation. In future studies on patients with neck pain, it may be possible to select an intervention method based on the characteristics of the disease.

Basic Characteristic Verification of High-damping Laminated Solar Panel with Viscoelastic Adhesive Tape for 6U CubeSat Applications (점탄성 테이프를 적용한 6U 큐브위성용 고댐핑 적층형 태양전지판의 기본 특성 검증)

  • Kim, Su-Hyeon;Kim, Hongrae;Oh, Hyun-Ung
    • Journal of Aerospace System Engineering
    • /
    • v.15 no.1
    • /
    • pp.86-94
    • /
    • 2021
  • PCB-based deployable solar panel is mainly used for CubeSat due to its lightweight and easy of electrical connection. However, as the size of solar panel increases, there is a limit to ensuring the structural safety of solar cells due to excessive dynamic displacement under launch vibration environment. In previous mechanical designs, for the minimization of dynamic deflection, panel stiffness is increased by applying additional stiffeners made of various materials such as aluminum or composite. However, it could have disadvantages for CubeSat design requirements due to limited mass and volumes. In this study, a high-damping 6U solar panel was proposed. It had superior damping characteristic with a multi-layered stiffener laminated with viscoelastic acrylic tapes. Basic characteristics of this solar panel were measured through free-vibration tests. Design effectiveness of the solar panel was validated through qualification-level launch vibration test. Based on test results, vibration characteristics of a typical PCB solar panel and the high-damping laminated solar panel were predicted and a comparative analysis was performed.

Active Vibration Control of a Cantilever Beam Using Fuzzy Control Scheme and PID Controller (퍼지 기법과 PID 제어기를 이용한 외팔보의 능동 진동 제어)

  • 최수영;김진태;박기헌
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.40 no.1
    • /
    • pp.1-10
    • /
    • 2003
  • This paper is concerned with the fuzzy control scheme and PID controller for the vibration suppression control of a cantilever beam equipped with a laser sensor and an electromagnetic actuator. The PID controller is being widely used in industrial applications. However, it is difficult to determine the appropriate PID gains in nonlinear systems and systems with time variant characteristic and so on. In this paper, we design the fuzzy based PID controller of which output gains are adjusted automatically and the designed controller is applied to active vibration control of a cantilever beam using electromagnetic actuator with strong nonlinearity. The tuning PID parameters of proposed controller are determined by using Fuzzy algorithm. Effectiveness and performance of the designed controller are verified by both simulation and experiment results. Experimental results demonstrate that better control performance can be achieved in comparison with the PID cotroller.

Effects of Limited Dorsiflexion Range of Motion on Movement Strategies during Landing (발등굽힘 관절가동범위 제한이 착지 시 움직임 전략에 미치는 영향)

  • Inje Lee;Donggun Kim;Hyeondeukje Kim;Hyunsol Shin;Jiwon Lee;Yujin Jang;Myeongwoo Pi
    • Korean Journal of Applied Biomechanics
    • /
    • v.33 no.4
    • /
    • pp.147-154
    • /
    • 2023
  • Objective: This study aimed 1) to compare the Landing Error Scoring System (LESS) score and movement patterns during landing of the lesser dorsiflexion range of motion (LDFROM) group to that with the greater dorsiflexion range of motion group, and 2) to identify the correlation between the weight-bearing dorsiflexion range of motion (WBDF ROM), LESS score, and movement patterns during landing. Method: Fifty health adults participated in this study. WBDF ROM was measured using the weight bearing lunge test while movement patterns during landing was assessed using the LESS. The joint angles of the ankle, knee and hip joints during landing were analyzed using the 2D video analysis. After mean value of WBDF ROM was calculated, participants were divided into two groups (GDFROM and LDFROM) based on the mean value. The Mann-Whiteny 𝒰 test was used to identify differences in movement strategies during landing between two groups and the Pearson's correlation analysis was performed to determine relationships between WBDF ROM and movement strategies. Results: The LDFROM group showed the poorer LESS score and stiffer landing kinematics during landing compared to the GDFROM group (p<0.05). In addition, DFROM was significantly related to the LESS score and landing kinematics (p<0.05) except for total hip excursion (p=0.228). Conclusion: Our main findings showed that the LDFROM group had poorer landing quality and stiffer landing movements compared to the GDFROM group. In addition, increase of WBDF ROM significantly improved landing quality and soft-landing movements. To reduce shock during landing such as ground reaction forces, individuals need to better utilize WBDF ROM and lower extremity movements based on our findings. Therefore, intervention programs for safer landings should include exercises that increase WBDF ROM and utilize eccentric contraction.

Comparison of the Effects of Applying Muscle Energy Techniques Versus Stretching Techniques to the Ankle Joint on Ankle Joint Range of Motion, Balance Ability and Gait Ability of Chronic Stroke Patients with Limited Ankle Dorsiflexion (근에너지 기법과 스트레칭 기법의 발목관절 적용이 발등굽힘 제한이 있는 만성 뇌졸중 환자의 발목 관절가동범위, 균형 능력, 보행 능력에 미치는 영향 비교)

  • Tae-hyeon Heo;Suhn-yeop Kim
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.19 no.1
    • /
    • pp.69-79
    • /
    • 2024
  • PURPOSE: This study compared the effect of the muscle energy technique (MET) and stretching technique on ankle dorsiflexion passive range of motion, balance, and gait ability of stroke patients with limited ankle dorsiflexion. METHODS: Forty-four post-stroke patients participated. The participants were randomized into the MET group (METG; n = 22) and the stretching group (STG; n = 22). The METG was subjected to the MET to relax the dorsiflexion, while the STG was subjected to the dorsiflexion stretching technique. Both groups completed standard neurological physical therapy for 30 min per session. The intervention was conducted five times a week over 3 weeks for a total of 15 times. All participants underwent ankle dorsiflexion passive range of motion measurement and Berg Balance Scale score determination and completed a 10-m walking test and the timed up and go test before and after the intervention. RESULTS: After the 3-week intervention, both groups showed significant improvement after the intervention (p < .05). METG participants showed greater improvements in ankle dorsiflexion passive range of motion and 10-m walking test results compared to STG participants (p < .05). CONCLUSION: Both interventions improved ankle dorsiflexion passive range of motion, balance, and gait ability in stroke patients with limited ankle dorsiflexion. Moreover, the MET was superior to ankle dorsiflexion passive range of motion on the 10-m walking test.

Analysis of the Flexural Vibrations for the Rotating Cantilevered Rectangular Plates (회전하는 외팔 사각판의 굽힘진동 해석)

  • 이종민;이영신
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1992.10a
    • /
    • pp.59-64
    • /
    • 1992
  • 터빈 블레이드와 같이 회전하는 구조물의 파단은 공진 근처에서 진동이 발 생할 때에 이에 기인하는 피로에 의하여 발생한다. 그러므로 이와 같은 파단 을 피하기 위해서는 설계 단계에서 이론적인 계산에 의하여 구조물의 고유 진동수를 결정하는 것이 상당히 중요하다. 판이 회전을 받게 되면 원심력에 의하여 판의 강성이 증가하므로 고유진동수가 회전하지 않는 판의 고유진동 수보다는 상당히 증가하게 된다. 이에 대한 연구가 국내외에서 상당수 행하 여졌지만, 연구의 대부분이 회전의 영향을 고려하지 않은 정지판(stationary plate)에 대한 것이며 뢰전을 고려한 연구는 극히 제한되어 있다. 또한 회전 의 영향을 고려한 연구의 대부분이 해석 대상을 보로서 단순화 시켰고 해법 으로는 유한요소법과 Ritz법 등을 사용하였다. 이는 블레이드가 지니고 있는 기하학적인 형상과 진동 특성이 해석적인 방법으로 해결하는 데에는 상당한 어려움이 있기 때문이다. 실제적으로는 터빈 블레이드와 같은 회전체의 진동 특성이 설치각이나 비틀림각, 판의 형상비, 회전속도 등의 변화에 의하여 영 향을 받기 때문에 보와 같은 진동 거동을 보이기보다는 판이나 셀과 같은 진동 거동을 보이므로 보다 정확한 해석을 수행하기 위해서는 해석 대상을 판이나 셀로서 취급하는 것이 타당하다. 따라서 본 연구에서는 위와 같은 이 유 때문에 해석 대상을 등방성 사각판과 직교이방성 복합재료 사각판으로 선택하였으며, 구조물의 고유진동수에 영향을 미치는 다음과 같은 인자들을 해석에 고려하였다. 1. 회전속도 (rotational speed) 2. 설치각 (setting angle) 3. 허브의 반경 (hub radius) 4. 판의 형상비 (aspect ratio) 5. 적층순서 (stacking sequence)구조물에 대한 동적실험(dynamic test)을 통하여 단기간에 동적특성을 결정하고 SDM(structure dynamic modification)이나 FRS(force response simulation)를 수행하여 임의의 좌표 공간에 대한 진동수준을 해석적으로 예측할 뿐만 아니라 구조물의 진동제어 를 위한 동적인자를 변경시킬 수 있는 정보를 제공하며 장비를 방진할 경우 신뢰성 있는 전달률을 결정할 수 있다. 실험적으로 철교, 교량이나 건물의 철골구조 및 2층 바닥 등 대,중형의 복잡한 구조물에 대항 동특성을 나타내 는 모빌리티를 결정할 경우 충격 가진 실험이 사용되는 실험장비 측면에서 나 실험을 수행하는 과정이 대체적으로 간편하다. 그러나 이 경우 대상 구조 물을 충분히 가진시킬수 있는 용량의 대형 충격기(large impact hammer)가 필요하게 된다. 이러한 동적실험은 약 길이 61m, 폭 16m의 4경간 교량에 대 하여 동적실험을 수행하여 가능성을 확인하였다. 여기서는 실험실 수준의 평 판모델을 제작하고 실제 현장에서 이루어질 수 있는 진동제어 구조물에 대 한 동적실험 및 FRS를 수행하는 과정과 동일하게 따름으로써 실제 발생할 수 있는 오차나 error를 실험실내의 차원에서 파악하여 진동원을 있는 구조 물에 대한 진동제어기술을 보유하고자 한다. 이용한 해마의 부피측정은 해마경화증 환자의 진단에 있어 육안적인 MR 진단이 어려운 제한된 경우에만 실제적 도움을 줄 수 있는 보조적인 방법으로 생각된다.ofile whereas relaxivity at high field is not affected by τS. On the other hand, the change in τV does not affect low field profile but stron

  • PDF

A Study on Residual Strength Assessment of Damaged Oil Tanker by Smith Method (Smith법에 의한 손상 유조선의 잔류강도 평가 연구)

  • Ahn, Hyung-Joon;Baek, Deok-Pyo;Lee, Tak-Kee
    • Journal of Navigation and Port Research
    • /
    • v.35 no.10
    • /
    • pp.823-827
    • /
    • 2011
  • The present Common Structural Rules for double hull oil tanker is not included the residual strength, which is one of the functional requirements in design part of Goal-based new ship construction standards (GBS). The GBS will be enforced after July 1, 2016. The requirement related residual strength has the goal to build safe ship even if she has the specified damages due to marine accidents including collision and grounding. In order to assess the residual strength based on risk for structural damages according to GBS, tons of nonlinear FE analysis work taking into account various types of damage will be needed. The Smith's method, a kind of simplified method for the strength analysis is very useful for this purpose. In this paper, the residual strength assessments based on ultimate strength using Smith's method were carried out. The objected ship is VLCC with stranding damage in bottom structures. Also, the results were compared with that of nonlinear FE analysis using three cargo hold model.

The fracture resistance of heat pressed ceramics with wire reinforcement (금속선 강화에 따른 열 가압 도재의 파절저항)

  • Jo, Deuk-Won;Dong, Jin-Keun;Oh, Sang-Chun;Kim, Yu-Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.191-198
    • /
    • 2009
  • Statement of problem: Ceramics have been important materials for the restoration of teeth. The demands of patients for tooth-colored restorations and the availability of various dental ceramics has driven the increased use of new types of dental ceramic materials. Improved physical properties of theses materials have expanded its use even in posterior crowns and fixed partial dentures. However, ceramic still has limitation such as low loading capability. This is critical for long-span bridge, because bridge is more subject to tensile force. Purpose: The wire reinforced ceramic was designed to increase the fracture resistance of ceramic restoration. The purpose of this study was to evaluate the fracture resistance of wire reinforced ceramic. Material and methods: Heat pressed ceramic(ingot No.200 : IPS Empress 2, Ivoclar Vivadent, Liechtenstein) and Ni-Cr wire(Alfa Aesar, Johnson Matthey Company, USA) of 0.41 mm diameter were used in this study. Five groups of twelve uniform sized ceramic specimens(width 4 mm, thickness 2 mm, length 15 mm) were fabricated. Each group had different wire arrangement. Wireless ceramic was used as control group. The experimental groups were divided according to wire number and position. One, two and three strands of wires were positioned on the longitudinal axis of specimen. In another experimental group, three strands of wires positioned on the longitudinal axis and five strands of wires positioned on the transverse axis. Three-point bending test was done with universal testing machine(Z020, Zwick, Germany) to compare the flexural modulus, flexural strength, strain at fracture and fracture toughness of each group. Fractured ceramic specimens were cross-sectioned with caborundum disc and grinded with sandpaper to observe interface between ceramic and Ni-Cr wire. The interface between ceramic and Ni-Cr wire was analyzed with scanning electron microscope(JSM-6360, JEOL, Japan) under platinum coating. Results: The results obtained were as follows: 1. The average and standard deviation in flexural modulus, flexural strength and fracture toughness showed no statistical differences between control and experimental groups. However, strain was significantly increased in wire inserted ceramics(P<.001). 2. Control group showed wedge fracture aspects across specimen, while experimental groups showed cracks across specimen. 3. Scanning electron microscopic image of cross-sectioned and longitudinally-sectioned specimens showed no gap at the interface between ceramic and Ni-Cr wire. Conclusion: The results of this study showed that wire inserted ceramics have a high strain characteristic. However, wire inserted ceramics was not enough to use at posterior area of mouth in relation to flexural modulus and flexural strength. Therefore, we need further studies.