• Title/Summary/Keyword: 굽힘거동

Search Result 239, Processing Time 0.024 seconds

Smart Structural Health Monitoring Using Carbon Nanotube Polymer Composites (탄소나노튜브 고분자 복합체 기반 스마트 구조건전성 진단)

  • Park, Young-Bin;Pham, Giang T.;Wang, Ben;Kim, Sang-Woo
    • Composites Research
    • /
    • v.22 no.6
    • /
    • pp.1-6
    • /
    • 2009
  • This paper presents an experimental study on the piezoresistive behavior of nanocomposite strain sensors subjected to various loading modes and their capability to detect structural deformations and damages. The electrically conductive nanocomposites were fabricated in the form of a film using various types of thermoplastic polymers and multi-walled carbon nanotubes (MWNTs) at various loadings. In this study, the nanocomposite strain sensors were bonded to a substrate and subjected to tension, flexure, or compression. In tension and flexure, the resistivity change showed dependence on measurement direction, indicating that the sensors can be used for multi-directional strain sensing. In addition, the sensors exhibited a decreasing behavior in resistivity as the compressive load was applied, suggesting that they can be used for pressure sensing. This study demonstrates that the nanocomposite strain sensors can provide a pathway to affordable, effective, and versatile structural health monitoring.

Estimation of Fatigue Crack Growth Behavior of Cracked Specimen Under Mixed-mode Loads (혼합모드 하중을 받는 균열시편의 피로균열진전거동 평가)

  • Han, Jeong Woo;Woo, Eun Taek;Han, Seung Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.7
    • /
    • pp.693-700
    • /
    • 2015
  • To estimate the fatigue crack propagation behavior of compact tension shear (CTS) specimen under mixed-mode loads, crack path prediction theories and Tanaka's equation were applied. The stress intensity factor at a newly created crack tip was calculated using a finite element method via ANSYS, and the crack path and crack increment were then obtained from the crack path prediction theories, Tanaka's equation, and the Paris' equation, which were preprogrammed in Microsoft Excel. A new method called the finite element crack tip updating method (FECTUM) was developed. In this method, the finite element method and Microsoft Excel are used to calculate the stress intensity factors and the crack path, respectively, at the crack tip per each crack increment. The developed FECTUM was applied to simulate the fatigue crack propagation of a single-edge notched bending (SENB) specimen under eccentric three-point bending loads. The results showed that the number of cycles to failure of the specimen obtained experimentally and numerically were in good agreement within an error range of less than 3%.

Study on Evaluation of Plastic Deformation Zone at Crack Tip for the Multi-Passed Weld Region of the Pressure Vessel Steel Using Nondestructive Method (비파괴법에 의한 압력용기 강 다층용접부의 균열선단에서 소성변형 역성장거동 평가에 관한 연구)

  • Na, Eui-Gyun;Lee, Sang-Guen
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.5
    • /
    • pp.473-478
    • /
    • 2009
  • The purpose of this study is to evaluate the behaviour of the plastic deformed zone at crack tip on the standard Charpy specimens which were taken from the multi-passed weld block of the pressure vessel steel. Notch was machined on the standard Charpy test specimens and pre-crack which was located around the fusion line was made under the repeat load. Four point bend and acoustic emission tests were carried out simultaneously. The size of plastic region at crack tip was calculated using stress intensity factor. Relationships between characteristics of acoustic emission and plastic zone size at crack tip were discussed through the cumulative AE energy. Regardless of the specimens, AE signals were absent within the elastic region almost and most of AE signals were produced at the plastic deformation region from yield point to the mid-point between yield and maximum load. More AE signals for the weldment were produced compared with the base-metal and PWHT specimen. Relations between plastic deformed zones at crack tip and cumulative AE energy for the weldment and PWHT specimen were different quietly from the base-metal. Besides, number of AE counts for the weldment was the larger than those of the base-metal and PWHT specimen.

Nonlinear Dynamic Analysis on Low-Tension Towed Cable by Finite Difference Method (유한차분법을 이용한 저장력 예인케이블의 비선형 동적해석)

  • Han-Il Park;Dong-Ho Jung
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.39 no.1
    • /
    • pp.28-37
    • /
    • 2002
  • In this study nonlinear dynamic behaviors of towed tow-tension cables are numerically analysed. In the case of a taut cable analysis, a bending stiffness term is usually neglected due to its minor effect but it plays an important role in a low-tension cable analysis. A low-tension cable may experience large displacements due to relatively small restoring forces and thus the effects of fluid and geometric non-linearities become predominant. The bending stiffness and non-linearity effects are considered in this work. In order to obtain dynamic behaviors of a towed low-tension cable, three-dimensional nonlinear dynamic equation is described and discretized by employing a finite difference method. An implicit method and Newton-Raphson iteration are adopted for the time integration and nonlinear solutions. For the calculation of huge size of matrices. block tri-diagonal matrix method is applied, which is much faster than the well-known Gauss-Jordan method in two point boundary value problems. Some case studies are carried out and the results of numerical simulations are compared with those of a in-house program of WHOI Cable with good agreements.

Analysis of the Flexural Vibrations for the Rotating Cantilevered Rectangular Plates (회전하는 외팔 사각판의 굽힘진동 해석)

  • 이종민;이영신
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1992.10a
    • /
    • pp.59-64
    • /
    • 1992
  • 터빈 블레이드와 같이 회전하는 구조물의 파단은 공진 근처에서 진동이 발 생할 때에 이에 기인하는 피로에 의하여 발생한다. 그러므로 이와 같은 파단 을 피하기 위해서는 설계 단계에서 이론적인 계산에 의하여 구조물의 고유 진동수를 결정하는 것이 상당히 중요하다. 판이 회전을 받게 되면 원심력에 의하여 판의 강성이 증가하므로 고유진동수가 회전하지 않는 판의 고유진동 수보다는 상당히 증가하게 된다. 이에 대한 연구가 국내외에서 상당수 행하 여졌지만, 연구의 대부분이 회전의 영향을 고려하지 않은 정지판(stationary plate)에 대한 것이며 뢰전을 고려한 연구는 극히 제한되어 있다. 또한 회전 의 영향을 고려한 연구의 대부분이 해석 대상을 보로서 단순화 시켰고 해법 으로는 유한요소법과 Ritz법 등을 사용하였다. 이는 블레이드가 지니고 있는 기하학적인 형상과 진동 특성이 해석적인 방법으로 해결하는 데에는 상당한 어려움이 있기 때문이다. 실제적으로는 터빈 블레이드와 같은 회전체의 진동 특성이 설치각이나 비틀림각, 판의 형상비, 회전속도 등의 변화에 의하여 영 향을 받기 때문에 보와 같은 진동 거동을 보이기보다는 판이나 셀과 같은 진동 거동을 보이므로 보다 정확한 해석을 수행하기 위해서는 해석 대상을 판이나 셀로서 취급하는 것이 타당하다. 따라서 본 연구에서는 위와 같은 이 유 때문에 해석 대상을 등방성 사각판과 직교이방성 복합재료 사각판으로 선택하였으며, 구조물의 고유진동수에 영향을 미치는 다음과 같은 인자들을 해석에 고려하였다. 1. 회전속도 (rotational speed) 2. 설치각 (setting angle) 3. 허브의 반경 (hub radius) 4. 판의 형상비 (aspect ratio) 5. 적층순서 (stacking sequence)구조물에 대한 동적실험(dynamic test)을 통하여 단기간에 동적특성을 결정하고 SDM(structure dynamic modification)이나 FRS(force response simulation)를 수행하여 임의의 좌표 공간에 대한 진동수준을 해석적으로 예측할 뿐만 아니라 구조물의 진동제어 를 위한 동적인자를 변경시킬 수 있는 정보를 제공하며 장비를 방진할 경우 신뢰성 있는 전달률을 결정할 수 있다. 실험적으로 철교, 교량이나 건물의 철골구조 및 2층 바닥 등 대,중형의 복잡한 구조물에 대항 동특성을 나타내 는 모빌리티를 결정할 경우 충격 가진 실험이 사용되는 실험장비 측면에서 나 실험을 수행하는 과정이 대체적으로 간편하다. 그러나 이 경우 대상 구조 물을 충분히 가진시킬수 있는 용량의 대형 충격기(large impact hammer)가 필요하게 된다. 이러한 동적실험은 약 길이 61m, 폭 16m의 4경간 교량에 대 하여 동적실험을 수행하여 가능성을 확인하였다. 여기서는 실험실 수준의 평 판모델을 제작하고 실제 현장에서 이루어질 수 있는 진동제어 구조물에 대 한 동적실험 및 FRS를 수행하는 과정과 동일하게 따름으로써 실제 발생할 수 있는 오차나 error를 실험실내의 차원에서 파악하여 진동원을 있는 구조 물에 대한 진동제어기술을 보유하고자 한다. 이용한 해마의 부피측정은 해마경화증 환자의 진단에 있어 육안적인 MR 진단이 어려운 제한된 경우에만 실제적 도움을 줄 수 있는 보조적인 방법으로 생각된다.ofile whereas relaxivity at high field is not affected by τS. On the other hand, the change in τV does not affect low field profile but stron

  • PDF

Effect of TESPT Silane Coupling Agent on Mechanical Properties of Precipitated Silica Filled NBR Compound for Oil Seal (TESPT 실란커플링제가 침전 실리카로 보강된 오일씰용 NBR복합소재의 기계적 물성에 미치는 영향)

  • Lee, Young-Seok;Hwang, Ki-Seob;Lee, Jong-Cheol;Kim, Tae-Geun;Ha, Ki-Ryong
    • Elastomers and Composites
    • /
    • v.46 no.1
    • /
    • pp.45-53
    • /
    • 2011
  • The effect of the silane coupling agent, bis(triethoxysilypropyl)tetrasulfide (TESPT), on mechanical properties of a silica-filled NBR compound for oilseal was investigated. Curing behavior and crosslinking density of the compounds were measured using ODR (oscillating disk rheometer) and swelling ratio in toluene. UTM (universal testing machine) and shore A hardness tester were used in order to study the characteristics of mechanical properties of original vulcanizates and aged ones with heated air and ASTM No. 3. oil. Recovery of elasticity which influences the performance and service life of oilseal was investigated by giving bending deformation to vulcanizates in aging condition. After bending aging test, recovery distance was measured and calculated angle of recovery from it. TR (temperature retraction) test was performed on these vulcanizates to determine the low temperature recovery behavior. Wear resistance was measured by Taber type abrasion tester. In addition, SEM was used to characterize the morphology of the worn surface of vulcanizates. The result showed that addition of TESPT into silica-filled compound improves not only compound flow-ability, interaction between NBR and silica and crosslinking density, but also hardness, 100% modulus, recovery of elasticity, wear resistance, heat resistance and ASTM No.3 oil resistance of vulcanizates.

Wear Characteristics According of Heat Treatment of Si3N4 with Different Amounts of SiO2 Nano-Colloid (SiO2 나노 콜로이드 량이 다른 Si3N4의 열처리에 따른 마모 특성)

  • Ahn, Seok Hwan;Nam, Ki Woo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.10
    • /
    • pp.1117-1123
    • /
    • 2014
  • This study sintered $Si_3N_4$ with different amounts of $SiO_2$ nano-colloid. The surface of a mirror-polished specimen was coated with $SiO_2$ nano-colloid, and cracks were healed when the specimen was treated at a temperature of 1273 K for 1 h in air. Wear specimen experiments were conducted after heat treatments for 10 min at 1073, 1273, and 1573 K. The heat-treated surface that was coated with the $SiO_2$ nano-colloid was slightly rougher than the noncoated surface. The oxidation state of the surface according to the heat treatment temperature showed no correlation with the surface roughness. Moreover, the friction coefficient, wear loss, and bending strength were not related to the surface roughness. $Si_3N_4$ exhibited an abrasive wear behavior when SKD11 was used as an opponent material. The friction coefficient was proportional to the wear loss, and the bending strength was inversely proportional to the friction coefficient and wear loss. The friction coefficient and wear loss increased with increasing amounts of the $SiO_2$ nanocolloid. In addition, the friction coefficient was slightly increased by increasing the heat treatment temperature.

Comparison of Mechanical Properties of Electrospun Nanofiber Web Layered Systems and Conventional Breathable Waterproof Fabrics (전기방사한 나노섬유 웹 처리소재와 상용 투습방수소재의 역학적 특성 비교)

  • Youn, Bo-Ram;Lee, Seung-Sin
    • Science of Emotion and Sensibility
    • /
    • v.13 no.2
    • /
    • pp.391-402
    • /
    • 2010
  • In this study, breathable waterproof materials were prepared by electrospinning. Five kinds of electrospun nanofiber web layered systems with different levels of nanofiber web density, as well as different substrates and layer structures were fabricated, and their mechanical properties (tensile, bending, shear, compression, surface, and thickness & weight) were measured by the KES-FB system and compared with those of conventional breathable waterproof fabrics (densely woven fabric, PTFE laminated fabric and PU coated fabric). The KES-FB measurements demonstrate that the lab-scale nanofiber web layered systems are more flexible and fuller than commercial nanofiber web layered systems, which have a more compact structure than the lab-scale nanofiber web layered systems. Densely woven fabrics and lab-scale nanofiber web layered systems showed lower values of tensile linearity (LT), bending stiffness (B), and shear stiffness (G) than those of PU coated and PTFE laminated fabric. These results indicate that they are more flexible and have less resistance to the shearing movement, corresponding to a more pliable material having a better drape, than PU coated fabrics and PTFE laminated fabrics.

  • PDF

Analysis of Compression Behavior on Intervertebral Disc L4-5 in Pedicle Screw System Instrumented Lumbar Spine under Follower Load (척추경 나사못을 이용한 척추 유합술에서 고정범위에 따른 인접 추간판의 압축 거동 분석)

  • Ahn, Myun-Whan;Ahn, Jong-Chul;Lee, Su-Ho;Chung, Il-Sub;Lee, Choon-Yeol;Lee, Jang-Woo
    • Journal of Yeungnam Medical Science
    • /
    • v.20 no.2
    • /
    • pp.160-168
    • /
    • 2003
  • Background: Confirm the stability of intervertebral disc sustaining each fused lumbar spine cases, comparing vertical compression, A-P shear force and rotational moment on intervertebral disc of instrumented lumbar spine with simple vertical compression load and follower load using finite element analysis. Materials and Methods: We analyze the stability of intervertebral disc L4-5 supporting fused lumbar spine segments. After performing finite element modelling about L1-L5 lumbar vertebral column and L1-L4 each fusion level pedicle screw system for fused lumbar spine fine element model. Intervertebral discs with complex structure and mechanical properties was modeled using spring element that compensate stiffness and tube-to-tube contact element was employed to give follower load. Performing geometrical non-linear analysis. Results: The differences of intervertebral disc L4-5 behavior under the follower compression load in comparision with vertical compression load are as follows. Conclusion: As a result of finite element interpretation of instrumented lumbar spine, the stability of L4-5 sustaining fused lumbar segment, the long level fused lumbar spine observed hing stability under follower load. This research method can be the basis tool of effects prediction for instrumentation, a invention of a more precious finite element interpretation model which consider the role of muscle around the spine is loaded.

  • PDF

A Study on Inelastic Lateral-Torsional Buckling of Stepped I-Beams Subjected to Pure Bending (균일모멘트를 받는 계단식 I형보의 비탄성 횡-비틀림 좌굴에 관한 연구)

  • Kim, Jong Min;Kim, Seung Jun;Park, Jong Sup;Kang, Young Jong
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.2
    • /
    • pp.237-246
    • /
    • 2008
  • The cross-sections of continuous multi-span beams sometimes suddenly increase, or become stepped, at the interior supports of continuous beams to resist high negative moments. The three-dimensional finite-element program ABAQUS (2006) was used to analytically investigate the inelastic lateral-torsional buckling behavior of stepped beams subjected to pure bending moment and resulted in the development of design equations. The flanges of the smaller cross-section were fixed at 30.48 by 2.54 cm, whereas the width and/or thickness of the flanges of the larger cross-section varied. The web thickness and height of beam was kept at 1.65 cm and 88.9 cm, respectively. The ratios of the flange thickness, flange width, and stepped length of beams are considered analytical parameters. Two groups of 27 cases and 35 cases, respectively, were analyzed for double and single stepped beams. The combined effects of residual stresses and geometrical imperfection on inelastic lateral-torsional buckling of beams are considered. First, the distributions of residual stress of the cross-section is same as shown in Pi, etc (1995), and the initial geometric imperfection of the beam is set by central displacement equal to 0.1% of the unbraced length of beam. The new proposed equations definitely improve current design methods for the inelastic LTB problem and increase efficiency in building and bridge design. The proposed solutions can be easily used to develop new design equation for inelastic LTB resistance of stepped beams subjected to general loading condition such as a concentrated load, a series of concentrated loads or uniformly distributed load.