• Title/Summary/Keyword: 굴절이상 변화

Search Result 191, Processing Time 0.026 seconds

The differences of tear film for young Korean of a day indoor space (실내 공간 내에서 한국인 청년의 하루 중 눈물층 변화)

  • Oh, Hyun Jin;Lee, Ji-Young
    • Journal of Digital Convergence
    • /
    • v.10 no.11
    • /
    • pp.535-540
    • /
    • 2012
  • This study is to research the differences of tear film for young people in of a day in a restricted indoor space. The subjects are 58 eyes volunteers for twice preliminary inspection and tear test of a day. 58 healthy individuals with no eye disease, no body disease, orthophoria, corrective visual acuity more than 0.8, binocular spherical equivalence difference over 0.50 diopter, the flattest corneal curvature in horizontal meridian and the steepest corneal curvature in vertical meridian were tested. The uncorrective visual acuity, refractive error, corneal curvature, schirmer test and tear break up test were performed in the morning and afternoon. Schirmer test were $16.0{\pm}7.0mm$ in the morning and $14.1{\pm}7.1mm$ in the afternoon. TBUT were $11.3{\pm}0.6$ sec in the morning and $12.1{\pm}0.9$ sec in the afternoon. They have no significant differences.

A study of myopia progression status for a diverse school group (초·중·고 학생들의 근시진행정도에 대한 고찰)

  • Shim, Hyun-Seog;Shim, Moon-Sik;Jung, Ju-Hyun;Ju, Seok-Hui
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.1
    • /
    • pp.29-33
    • /
    • 2003
  • There are reports that the myopia progression have been difference according to myopia degree and age. In this studies, we divided into three investigated groups. The A group is the lower elementary school(50), the B group is the high elementary school(50), the C group is the junior high school(50) and the D group is the high school students(50). The myopia progression have been compared with each group and most variable terms have been investigated. We have analyzed the refraction inspection record that were investigated to put on spectacles in three years(visiting three times or more). The subject of study were 200 persons(men 100, women 100), 1. The distribution of equivalence with ages : A group -2.72D, B group -2.90D, C group -3.53D, D group -3.96D. 2. The pupillary distance have been 57.4mm(A), 59.9mm(B), 61.6mm(C), 63.4mm(D). 3. On a monthly variation : -0.02D(A), -0.045(B), -0.050D(C), -0.025(D) in men, and -0.06D(A), -0.06D(B), -0.045(C), -0.04D(D) in women. 4. After due considering monthly variation and suppose that the variatting times of spectacles degress were time of refracting inspection. The result : 3.6 month for A group, 4.8 month for B group, 5.3 month for C group and 7.7 month for D group.

  • PDF

DC pulse sputter로 제작한 단열필름 컬러화에 대한 연구

  • Lee, Dong-Hun;Park, Eun-Mi;Seo, Mun-Seok;Kim, Hye-Jin;Ha, In-Ho;Jo, Eun-Seon;Han, Geon-Hui
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.167.2-167.2
    • /
    • 2016
  • 태양에너지는 전자기파로써 파장에 따라 여러 부분으로 나뉜다. 파장이 780nm 이상인 부분의 영역을 IR (infra Red) 즉 적외선으로 불린다. 이 부분이 열선에 해당하는 부분인데 대부분의 창문에 설치된 커튼이나 vertical 등은 빛을 차단하는 수단일 뿐, 유입되는 열 (적외선)을 차단시킬 수는 없다. 열은 결국 실내의 온도를 높이기 때문에 난방비 등 에너지 손실을 막긴 어렵다. 단열필름은 커튼이나 vertical과 달리 실내로 유입되는 열 (적외선)을 다시 실외로 반사시켜 실내로 유입되는 열을 최소화 한다. 본 연구는 IR 차폐를 목적으로 연구 되었고, 거기서 한 발 나아가 실내 분위기 등을 고려하여 소비자의 구호에 맞는 제품에 더 맞추기 위해 연구되었다. 기존 제품들과 차별된 점은 색상을 위한 추가적인 작업없이 굴절률과 두께 factor 등을 변화시켜 바로 7가지 색을 구현한다는 장점을 가지고 있다. 따라서 가격 경쟁력에서도 우위를 점 할 수 있는 중요한 기술이라 할 수 있겠다. 박막제조 장비로는 DC pulse In-line Sputter를 사용하였으며, 굴절률과 광학적인 두께 측정을 위한 ellipsometer, 그리고 UV-vis 를 통한 Transmittance 측정으로 제품 능력을 확인하였다.

  • PDF

A Study on the Current Measurement Using Spun Fiber (Spun 광섬유를 이용한 전류 측정에 관한 연구)

  • Kwon, Won-Hyun;Jeon, Suk-Hee;Kim, Young-Soo;Kim, Yo-Hee;Park, Han-Kyu
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.25 no.10
    • /
    • pp.1158-1165
    • /
    • 1988
  • In this paper, the polarization properties of spun fiber due to intrinsic birefringence and magneto-optic effects are theoretically analyzed and experimented. The degree of polarization which indicates the intrinsic birefrigence is measured over 0.818, and the variation of output polarization angle with input polarization angle is measured within 9$^{\circ}$. Compared with single mode fiber, spun fiber is found to have very excellent polarization-maintaining property. Implemented current measurement system using spun fiber can linearly measure the magnetic field up to 20,000 A/m generated by solenoid.

  • PDF

Design of Ulta-short Fused Vertical Coupler Switches Composed of Two Sections (두 개의 영역으로 구성된 매우 짧은 길이를 가지는 융합된 수직 방향성 결합 스위치 설계)

  • Cho, Sung-Chan;Seol, Jong-Chol;Kim, Boo-Gyoun
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.10
    • /
    • pp.42-50
    • /
    • 2000
  • We show that both cross and bar states with high extinction ratios larger than 30dB can be achieved at eh same ends of ultra-short fused vertical directional coupler switches with two sections by changing the refractive indices of cores and inner cladding layers less than 1%. Based on the calculation of extinction ratios of cross state and bar state for various refractive index and thickness of inner cladding layer and core using the improved coupled mode theory and beam propagation method, the guidelines for design to achieve large tolerances in refractive indices of core and inner cladding layer in fused vertical directional coupler switches are presented.

  • PDF

Changes of Refractive Correction Value with Different Age Group: A Case for Myopia Control Lens, Single Vision Lens and Reverse Geometry Contact Lens (Myopia Control Lens, Single Vision Lens, Reverse Geometry Contact Lens의 연령에 따른 굴절교정상태 변화에 대한 추적 연구)

  • Yoon, Min-Hwa
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.1
    • /
    • pp.75-84
    • /
    • 2013
  • Purpose: Changes of refractive correction value in different age group were investigated. Regarding the inhibitive effects against myopia progression after wearing reverse geometry contact lenses and myopia control lenses (MC lenses), the effects after wearing single vision lenses were compared. Methods: We organized children between the ages of six and fifteen into three groups by age, and distributed fifty-seven reverse geometry contact lenses, fifty-six MC lenses and seventy-eight single vision lenses among them to be worn. Group 1 consisted of children aged ten and under, Group 2 consisted of children between the ages of eleven and fifteen, and Group 3 represents all of the study participants. The aim of this study was to learn the inhibitive effects against myopia progression attained by changes of refractive correction value and to verify their statistical significance at twelve months and under, thirteen to twenty-four months and twenty-five to thirty-six months. Results: Changes of refractive correction value by each length of use in Group 3 were as follows. For the age group of under twelve months, participants using the reverse geometric contact lens showed no change, while those using the MC or single vision lens had significant changes (P<0.05) of $-0.36{\pm}0.10$ D and $-0.67{\pm}0.52$ D, respectively. Users of all three lens types displayed significant change (P<0.05), in the age group of between thirteen and twenty-four months, of $0.18{\pm}0.49$ D, $0.60{\pm}0.42$ D and $1.37{\pm}0.72$ D for users of the reverse geometry contact lens, the MC lens and the single vision lens, respectively. There were significant changes (P<0.05) of $0.29{\pm}0.61$ D, $0.93{\pm}0.57$ D and $1.72{\pm}0.78$ in the same respective order as the above in the age group of twenty-five to thirty-six months. Refractive correction value showed changes with different age group. Group 1 displayed significant changes (P<0.05) of $0.29{\pm}0.73$ D, $1.07{\pm}0.59$ D and $1.75{\pm}0.74$ D for users of the reverse geometry contact lens, MC lens and single vision lens, respectively, up to thirty-six months of lens wearing; Group 2, also up to thirty-six months, displayed significant changes (P<0.05) of $0.28{\pm}0.42$ D, $0.75{\pm}0.49$ D and $1.70{\pm}0.84$ D in the same respective order, and changes in refractive correction for the age group under ten years was significantly greater (P<0.05) for the age group of eleven and older. Conclusions: The results found in this study demonstrate that there were no changes of refractive correction value for the case of wearing reversing geometry contact lens up to twelve month or less. MC lens showed less changes in variations of visual acuity for all users which might be resulted in inhibiting progression of myoptia. When both reverse geometry contact lens and the MC lens are wearing for the period from 13 to 36 month, both lens showed less changes in variation of visual acuity for all users. The results suggested that the less changes in variation of visual acuity of both lens had an effect on inhibiting progression of myopia.

단열 멀티코팅을 위한 RF Magnetron Sputter로 성장시킨 상온 TiO2의 광학적 특성 연구

  • Lee, Dong Hoon;Park, Eun Mi;Suh, Moon Suhk
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.341.2-341.2
    • /
    • 2014
  • 산화물 반도체는 가시광선 영역인 380~780 nm 부근에서의 투과율이 80% 이상이고, 3.2 eV 이상의 band gap과 높은 mobility를 가지는 물질로서 투명한 스마트 창호필름이나 디스플레이에 유망한 물질로 연구되고 있다. 본 연구에서는 스마트 윈도우에 적용되는 높은 가시광 투과율과 적외선 차단을 위한 필름개발을 목적으로 산화물 반도체인 $TiO_2$ 물질을 RF Sputter를 이용하여 상온에서 박막성장을 하였다. Glass와 PET 위에 동시에 성장시켜 각각의 기판에 성장된 $TiO_2$ 박막의 물리적인 성질 등을 조사하였다. 측정은 Ellipsometry를 이용하여 광학적인 두께와 굴절률을 조사하였고 UV visible spectrometer를 통해 광학적인 투과도를 확인하였다. 100Watt 부터 RF power를 높여가며 Working Pressure 변화변 주었을 때 낮은 RF power와 Working Pressure에서 높은 가시광 투과율을 확인 할 수 있었다.

  • PDF

Variable Optical Attenuator based on Side Polished Fiber Technique (측면 연마 광섬유를 이용한 가변 광 감쇠기)

  • 구숙영;정치섭
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.3
    • /
    • pp.222-228
    • /
    • 2004
  • The variable optical attenuator based on side polished fiber technique was experimentally demonstrated. Various combination mixtures of poly(vinylidene fluoride) and poly(methyl methacrylate) have been used as the overlay waveguide materials for the variable optical attenuator application. A controllable amount of optical power can be extracted via evanescent coupling by changing the temperature of the polymer mixture, thereby changing its refractive index. The VOA under test provides a maximum attenuation of 30 ㏈ and an insertion loss of 0.1 ㏈.

The Change in Corneal Eccentricity on the Correction of Refractive Error using Reverse Geometry Lens (역기하렌즈(Reverse Geometry Lens)의 굴절교정시 각막 편심률(Eccentricity)의 변화)

  • Lee, Seok-Ju;Park, Seong-Jong;Chun, Young-Yun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.2
    • /
    • pp.145-150
    • /
    • 2010
  • Purpose: In this study we investigated the correlation between the effect of myopia correction and the change of corneal eccentricity using reverse geometry lens. Methods: The 23 students (46 eyes) continuously wearing reverse geometry lens during 3 months were divided into Group I and Group II by different parameter fitting methods of wearing Reverse Geometry Lens. We measured a corneal eccentricity for Group I and Group II at $10^{\circ}$, $20^{\circ}$, and $30^{\circ}$ positions from corneal apex before wearing reverse geometry lens, 1 week, 1 month, and 3 months after wearing reverse geometry lens. We also measured an uncorrected visual acuity, a spherical equivalent, and a corneal radius and analyzed the correlation between them and the change of corneal eccentricity using statistical significance test. Results: There were the statistical significances of a change of corneal eccentricity (p=0.03, t=-2.29) for Group I and Group II at 10 position from corneal apex in a week after wearing reverse geometry lens, but were not those (p>0.05) in 1 month, and 3 months after wearing reverse geometry lens. There were the statistical significances of correlation between the change of corneal eccentricity and a corrected visual acuity, and a corneal radius, respectively. Particularly, the high correlation between the change of corneal eccentricity and a corrected visual acuity (r=-0.36, p=0.00, t=6.5), and a spherical equivalent (r=-0.72, p=0.00, t=-70.5) for Group II in a week after wearing reverse geometry lens showed. Conclusions: We knew from these results that the high correlation between the effect of myopia correction and the change of corneal eccentricity in a week after wearing reverse geometry lens represented.

The Investigation of the Changes of Visual Problems in VDT Workers (VDT 작업 전·후 시기능 변화)

  • Gang, Myoung Jin;Choe, Oh Mok
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.2
    • /
    • pp.33-39
    • /
    • 2002
  • The purpose of this study is to evaluate the effects of continuing work on VDT(video display terminal). Therefore, we examined visual fatigue by a questionnaire and measured frequency of blinking, tear film break-up time(BUT), height of palpebral fissure, visual acuity, refraction with retinoscopy and accommodation before and after two hour long VDT work. For the ocular symptoms, the greatest number was tired eyes accounting for 34%. In the visual symptoms, blurred vision was the highest rate of 83% and in case of systemic symptoms, shoulder pain was 38% marked top ranking but other symptoms were also distributed similar rate. The frequency of blinking during VDT work decreased significantly comparing with the one at rest. The average frequency of blinking is 8/min during VDT work and 22/min at rest. The BUT measured immediately after VDT work decreased much more than in the resting state. The average BUT was 7sec immediately after VDT work and 12sec at rest. The height of palpebral fissure during VDT work increased significantly comparing with the value at rest. The average height of palpebral fissure was 7.69mm at rest and 9.04mm during VDT work. The average visual acuity decreased almost 9.5% from 0.63 to 0.57, but refraction with retinoscopy increased about 0.28D to the direction of myopic shift. The amplitude of accommodation decreased approximately 1.49D from 7.98D to 6.49D and this resulted from the prolongation of near point of accommodation. Near point of convergence also was prolongated from 9.45cm to 10.30cm after VDT work.

  • PDF