Study of exhaust stack degin for effective diffusion of atmospheric pollutant (대기오염물질의 효과적인 확산을 위한 굴뚝 설계에 관한 연구)

  • 김종철;김태형
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 1999.10a
    • /
    • pp.250-251
    • /
    • 1999
  • 미국 산업환기 매뉴얼에서 빗물을 가장 효과적으로 방지하는 굴뚝으로 권장하고 있는 이중 굴뚝(Vertical Discharge Stack)을 우리의 기상조건에서 검증하여 그 사용가능성을 검토하고 기존에 우리 나라에서 가장 많이 사용되고 있는 삿갓모양과 "ㄱ" 모양 굴뚝의 불합리성을 지적할 뿐만 아니라 아울러 빗물 유입 방지나 배기저항을 최소화하고 배기확산에도 효과적인 새로운 모양의 굴뚝을 연구해 보고자 한다. (Clarke, J. H, 1965 ; Hama, G. M., 1963 ; ACGIH, 1998)(중략)

  • PDF

Influence of the Entrance and Exit Lengths on the Natural Convection Heat Transfer of a Cylinder in a Duct (도관내 원형관의 자연대류 열전달에서 입구 및 출구 길이 효과)

  • Lim, Chul-Kyu;Chung, Bum-Jin
    • Journal of Energy Engineering
    • /
    • v.21 no.1
    • /
    • pp.18-25
    • /
    • 2012
  • This work investigated the influence of the chimney dimensions(exit and entrance length, and diameter) on the heat transfer of a vertical cylinder in a duct. The measured mass transfer rates for the natural convection of vertical cylinder in a duct were presented for Prandlt number 2,094, Rayleigh number in the range of $4.55{\times}10^9$, $5.79{\times}10^{10}$, and $1.69{\times}10^{11}$. Experiments were performed using a copper sulfate electroplating system to simulate heat transfer based upon the analogy concept. The diameter of the duct was varied from 0.06 m to 0.14 m, and the heights from 0.30 m to 1.10 m. Nusselt numbers measured at open channel condition agreed well with the existing laminar heat transfer correlations for vertical plate developed by Le Fevre. The increase of the exit length enhanced the heat transfer up to a certain duct height but further increase does not affects the heat transfer. The heat transfer decreased with increasing the entrance length up to a certain duct height and was constant at further increase. The Nusselt number decreased with increasing the diameter of duct, until Nusselt number becomes similar to that at open channel beyond a certain diameter.

초고층건물에서 발생되는 굴뚝효과 방지대책

  • 권용일;박명식
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.33 no.12
    • /
    • pp.32-38
    • /
    • 2004
  • 초고층건물의 건설이 증가되고 있지만 건물외파와 출입문의 기밀도가 낮게 유지될 때, 이러한 누설면적과 층별로 구획할 수없는 수직샤프트(계단실 등)와 직렬로 배치될 경우, 필연적으로 발생하게 되는 굴뚝 현상(stack effect)의 발생원인과 차압크기 산정하는 방법 및 예방대책을 소개하고자 한다.

  • PDF

피동형 격납건물 냉각계통 내 돔 효과의 수치적 해석에 관한 연구

  • 전지한;박홍준;이은철
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.05a
    • /
    • pp.298-303
    • /
    • 1997
  • 실제의 격납건물의 구조는 하부 원통형의 구조를 가지는 영역과 상부 돔 형태와 굴뚝 형태의 구조를 가지는 영역으로 나눌 수 있다. 하부 원통형의 구조만을 고려한다면, 고온의 철제 벽면과 콘크리트 벽면 사이의 gap 크기에 비해서 원통의 반지름이 상대적으로 매우 큰 값을 가지기 때문에 2차원 무한평판으로 가정하는 것이 가능하다. 그러나 돔 및 굴뚝 영역에서는 높이가 높아질수록 돔 단면직경이 감소하고 굴뚝 영역도 유동단면적이 작은 원통의 구조를 가져 2차원 무한평판의 가정에 많은 무리가 따른다. 앞에서 명시한 세 가지의 격납건물 형태에 있어서 ASPWR의 경우는 굴뚝을 포함한 영역까지도 무한평판으로 가정하는 것이 가능하나(돔에서의 열전달 단면적이 하부의 열전달 단면적에 비해 매우 작다는 가정을 한다면) 나머지 AP600과 HWRF의 격납건물에 있어서는 상부까지도 무한평판 가정을 사용하는 것에는 무리가 있다. 본 연구에서는 일반적인 유체해석 코드인 FLUENT V4.3을 이용하여 실제 격납건물 구조에 대한 분석을 시도하여 무한평판 구조에 대한 가정이 과도한 열전달량을 예측하고 있음을 확인하였다.

  • PDF

Influence of Stack Effect in High-Rise Buildings on Wind Effect in Jeju (Comparative Analysis of Seoul and Jeju) (제주지역 고층건축물에서의 바람의 영향이 굴뚝효과에 미치는 영향 분석 (서울과 제주지역간의 비교 분석))

  • Lim, Chae-Hyun
    • Fire Science and Engineering
    • /
    • v.29 no.6
    • /
    • pp.6-12
    • /
    • 2015
  • This study used CONTAM modeling to analyzed analyze the stack effect in high-rise buildings for the terrain and weather conditions of Seoul and Jeju. The differential pressure caused by the stack effect is a function of the indoor and outdoor temperature difference and the height of the vertical shaft. Jeju is considered more stable than Seoul, because it is warmer than Seoul in winter. The differential pressure in Jeju is about 60% that of Seoul in for the same height of buildings in winter. However, Jeju is an island and the neutral plane is raised by over 56% by strong winds, although there is less differential pressure caused by the stack effect in Jeju than in Seoul. Due to the raised neutral plane, the region and magnitude of negative pressure in the lower part is larger in Jeju than in Seoul.

Design of Heating Supply System for Facility House using Industrial Chimney Waste Heat (산업용 굴뚝 폐열을 활용한 시설하우스 난방 공급 시스템 설계)

  • Chang-Jo Lee;Jin-Gwang Koh;Sung-Keun Lee
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.4
    • /
    • pp.661-668
    • /
    • 2023
  • A large amount of fuel is required for heating the agricultural facility house, and many farmhouses are experiencing the burden of heating costs due to the recent increase in fuel prices. This paper proposes a supply system that supports heating of agricultural facility houses located nearby by utilizing industrial chimney waste heat, and analyzes the application and effect of a heating cost reduction model. The system was designed based on the chimney waste heat system, and the facility house heating cost reduction model was applied and effect analysis was performed based on the proposed model. It was confirmed that the high-temperature waste heat from the chimney can be used to supply heating to facility houses in nearby farms. If heating is supplied to large-scale facility houses near industrial complexes, it is expected to contribute to improve productivity and competitiveness of domestic farms.

Design for Pressurizing System about Vestibule by Stack Effect & Engineering Analysis - Focused on Case Study - (굴뚝효과와 공학적분석에 의한 부속실 가압시스템 설계 - 사례를 중심으로 -)

  • Kim, Yong-Kwang
    • Fire Science and Engineering
    • /
    • v.23 no.4
    • /
    • pp.145-153
    • /
    • 2009
  • We are generally applicate smoke control only vestibule about special escape staircase, it is one of some smoke control model of NFSC 501A. But there are some point at issue in this system. The smoke control system on supervision field of writer is smoke control only vestibule same as the other resemble field. Writer studied in the concrete to find a solution at this issue, and derived a conclusion the most reasonable system on the field is "same time smoke control for staircase and vestibule" by the engineering analysis considering stack effect.

A Numerical Analysis on the Indoor Air Ventilation by Stack Effect and Outdoor Wind in a High-rise Residential Building (초고층 주거건물에서 굴뚝효과와 외풍영향에 인한 실내 환기 기류해석 및 평가에 관한 연구)

  • Kim, Chi-Wan;Lim, Tae-Kun;Ahn, Young-Chull
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.12
    • /
    • pp.828-835
    • /
    • 2011
  • The purpose of this study is to analyze and evaluate the 3 types of indoor ventilation methods such as natural, mechanical, and hybrid ventilation in high-rise building which is affected by stack effect and outdoor air pressure. For the evaluation of the ventilation capacity, CFD simulation was performed in a typical high-rise residential building. The results of the simulations are as follows: 1) Natural ventilation method is not enough to the regulation. 2) In case of mechanical ventilation, congested area is occurred but meets the regulation. 3) In case of hybrid ventilation with stack effect, all the areas of indoor meet the regulation and congested area is reduced. 4) In case of high-rise building, the differences of ventilation rate among houses in the building are not large because the mechanical ventilation is main factor.

Application of Solar Chimney System for Natural Ventilation in Underground Space (지하공간의 자연환기를 위한 태양 굴뚝 시스템의 응용)

  • Jang, Hyang-In;Suh, Seung-Jik
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.2
    • /
    • pp.87-95
    • /
    • 2010
  • This study analyzed the performance of solar chimney system for natural ventilation in underground space. A mathematical model of the solar chimney was proposed in order to predict its performance under varying parameters and Korea climatic condition. Steady state heat transfer equations were set up using a energy balanced equations and solved using a inverse matrix method. Numerical simulation program to analyze system was developed by using MATLAB. As the results, the ventilation performance of the solar chimney was determined by the temperature difference of air channel and inlet, and the temperature difference was influenced by insolation, stack height and distance of air gab. Also the solar chimney system can provide $262.9m^3/h$ of annual average ventilation rate. Because seasonal differences of ventilation rate was calculated within 25%, the solar chimney system can be used for every season in Korea climatic condition. Through this study, performance of solar chimney system for natural ventilation was verified by numerical method. Consequently, the solar chimney system is proved to be effective device for natural ventilation utilizing at all times, and the additional studies should be made through the experimental method for imagineering and commercialization.

기술개발성공사례 - 한국에너지기술연구소 조순행박사팀

  • Korean Federation of Science and Technology Societies
    • The Science & Technology
    • /
    • v.32 no.1 s.356
    • /
    • pp.90-91
    • /
    • 1999
  • 우리나라는 세계 12위의 이산화탄소 배출국으로 앞으로 기후변화협약에 따라 2000년까지 배출량을 5% 줄여야 한다. 그런데 최근 한국에너지기술연구소의 조순형박사팀은 공장 굴뚝에서 나오는 배기가스에서 이산화탄소를 흡착ㆍ분리하여 회수하는 새로운 기술개발에 성공하는 개가를 올렸다. 이렇게 분리된 이산화탄소는 99.9% 고순도로 공업용 화학원료로 재활용이 가능하여 일석이조의 효과를 얻게 되었다.