• Title/Summary/Keyword: 굴곡 각

Search Result 242, Processing Time 0.02 seconds

Effects of the color components of light-cured composite resin before and after polymerization on degree of conversion and flexural strength (광중합형 복합레진의 중합 전, 후의 색 성분이 중합률과 굴곡강도에 미치는 영향)

  • Yoo, Ji-A;Cho, Byeong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.4
    • /
    • pp.324-335
    • /
    • 2011
  • Objectives: This study investigated the effects of the color components of light-cured composite resin before and after polymerization on degree of conversion (DC) and biaxial flexural strength (FS). Materials and Methods: Four enamel shades (A1, A2, A3, A4) and two dentin shades (A2O, A3O) of Premisa (Kerr Co.) and Denfil (Vericom Co.) were evaluated on their CIE $L^*,\;a^*,\;b^*$ color components using the spectrophotometer before curing, after curing and at 7 day. The DC of same specimens were measured with Near-infrared spectrometer (Nexus, Thermo Nicolet Co.) at 2 hr after cure and at 7 day. Finally, the FS was obtained after all the other measurements were completed at 7 day. The correlations between each color component and DC and FS were evaluated. Results: The light-curing of composite resin resulted in color changes of Premisa in red-blue direction and Denfil in green-blue direction. The DC and FS were affected by product, time and shade (3-way ANOVA, p < 0.05) and product and shade (2-way ANOVA, p < 0.05), respectively. Premisa only showed a significant correlation between the DC and CIE $a^*$ component - before and after polymerization (Pearson product moment correlation, p < 0.05). The FS of Premisa showed significant negative correlations with CIE $a^*$ and CIE $b^*$ components. Conclusions: The DC and FS of the light-curing composite resin were affected by the color components of the material before and after polymerization.

Research on the Bamboo in Korea(Part 10) - On the Bending Test of Phyllostachys reticulata (한국산(韓國産)의 죽류(竹類)에 관(關)한 연구(硏究)(제(第)10보(報)) - Phyllostachys reticulata의 굴곡시험(屈曲侍險)에 대(對)하여 -)

  • Chong, Hyon Pae
    • Journal of Korean Society of Forest Science
    • /
    • v.6 no.1
    • /
    • pp.27-31
    • /
    • 1967
  • The bamboo is a plant whose culm grows straight up. This growing characteristics has been widely utilized in industry and craft. But the developments of handcraft making and horticultural techniques in recent years become to demand the bent bamboo culms. This study has been conducted at the experimental grove located at Hyunnae Ri, Okkye Myun, Myungju Gun, Kangwon Do since 1960. Although it has been known that the secret for which bamboo shoots complet growth within 40 odd days lies in their rhizomes, this writer felt the bamboo culm sheath might be another factor in addition. Hence some were stripped of sheath in this bending study as the following: 1. Time of sheath stripping. 2. Direction of sheath stripped for arbitrary bending. 3. Accuracy of bending following the size (growth) of bamboo shoots. The following results were obtained: 1. Bamboo shoots begin to appear in April. But the bamboo shot up in June showed the best bending result with 68% of bending efficiency. 2. Bending of the culm was facilitated by stripping off the sheath located on the side of the direction toward which bending was desired. By doing this, the culm could be bent as much as 90 degrees. But the culm totally stripped of sheath could be bent in any direction. 3. In order to determine the accuracy of bending of bamboo shoots growing, sheath were stripped off the shoots of which height ranged from 10 centimeter to 150 centimeters. The shoots with height of 110 centimeters showed the best result with 90%.

  • PDF

The effects of the number of times dipped in coloring liquid and final sintering temperature on flexural strength of zirconia ceramics: Zirconia ceramics having improved transparency (착색액 침지 횟수와 최종 소결 온도가 지르코니아 세라믹의 굴곡강도에 미치는 영향)

  • Kong, Moon-Chun;Kim, Kap-Jin;Kown, Tae-Yub;Hong, Min-Ho
    • Korean Journal of Dental Materials
    • /
    • v.44 no.2
    • /
    • pp.171-178
    • /
    • 2017
  • The purpose of this study is to investigate the effect of number of times dipped in coloring liquid and sintering temperature on the flexural strength of zirconia ceramic. In this study, using a zirconia block having improved transparency, specimens with size of $25mm{\times}2mm{\times}1.5mm$ were fabricated. The zirconia ceramic specimens were divided into three groups according to the number of times dipped in coloring liquid by 0, 2 and 4 times, and dyed in the coloring liquid to give color to each specimen. Then, after sintering them at the final temperature of $1,450^{\circ}C$ and $1,600^{\circ}C$, flexural strength was measured using a universal testing machine (total 6 group, n=10 for each group). Also, a scanning electron microscopy (SEM) was performed to observe its microstructure, and the data obtained through the experiment were analyzed with two-way ANOVA. The results of the flexural strength analysis show that the highest value was measured $762.3{\pm}42.3MPa$ in EKL2 group, while the lowest value was $516.4{\pm}77.1MPa$ in EKH4 group. According to the results of the two-way ANOVAs, flexural strength was not related with interaction between sintering temperature and number of times dipped in coloring liquid ($R^2=0.737$). However, there were statistically significant differences in flexural strength depending on sintering temperature (P<0.001). The flexural strength of zirconia ceramics having improved transparency was dependent on sintering temperature. The number of times dipped in the coloring liquid did not affect flexural strength of the zirconia ceramic having improved transparency.

A Study of the Characteristics of the Human External Auditory Canal Using 3-Dimensional Medical Imaging (3차원 의료영상을 이용한 인체 외이도 특징에 관한 연구)

  • Kim, Hyeong-Gyun
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.6
    • /
    • pp.467-473
    • /
    • 2017
  • Using Digital Imaging and Communications in Medicine(DICOM) and a 3D medical imaging program, the characteristics of the external auditory canal(EAC) were compared. Using images of the ears of 63 different male and female subjects of varying age, this study measured and compared EAC transverse axis lengths, internal diameter circumferences, and upper and lower curvature angles. The findings of the study indicated differences in EAC shapes according not only to age and sex but also to the left and right of the same subject. A comparison between the sexes of the subjects (35 males and 28 females) indicated that, on average, the length of the EAC was 4.75mm longer in males. Based on the lower curvature angle, the interior side of the diameter circumference of the EAC was found to be reduced on average by 37.2% compared to the exterior side. Although the upper curvature angle was on average $25.7^{\circ}$ larger than the lower curvature angle, 4 subjects showed a larger lower curvature angle and large differences between the upper and lower curvature angles were observed in 8 subjects of the younger age group (4~14 years old). This indicated changes in EAC curvature shapes during growth. This study presents a method to raise safety and precision by comparing direct measurements taken through physical means and indirect measurements acquired from existing ear samples. This was possible due to technological developments in which 3D medical image representation technology creates images close to reality, and, through further development, this method is expected to be used for standardization research of EAC shapes.

Study on the Change of Nerve Conduction with Wrist Flexion in Carpal Tunnel Syndrome (수근관증후군에서 수근관절굴곡이 신경전도속도에 미치는 영향)

  • Lee, Se-Jin;O, Kyung-Yoon;Park, Mee-Yeong;Hah, Jung-Sang;Byun, Yeung-Ju;Park, Choong-Suh
    • Journal of Yeungnam Medical Science
    • /
    • v.8 no.1
    • /
    • pp.79-85
    • /
    • 1991
  • The author studied 20 healthy adults (20 hands) as a control and 30 patients (40 hands) with carpal tunnel syndrome to evaluate the clinical usefulness of measuring nerve conduction velocity after wrist fiexion in diagnosis of carpal tunnel syndrome. The median nerve conduction velocity over wrist to finger segment was measured before and after wrist flexion for 1, 2 and 5 minutes, using belly-tendon method for motor nerve distal latency(MNDL) and antidromic method for sensory nerve conduction velocity(SNCV). The results were as follows : 1. In control froup, MNDL increased in 1 hand and SNCV decreased in 2 hands after wrist flexion. In patient group, MNDL increased in 2 hands and SNCV decreased in 3 hands after wrist flexion. 2. In both control and patient group, there were no significant changes in mean values of SNCV and MNDL between before and after wrist flexion. 3. Phalen's wrist flexion test was positive in 5 percent of control and 60 percent of patient group. 4. Tinel's sign was present in 10 percent of control and 33 percent of patient group.

  • PDF

Sensitivity of Marker Set and Knee Joint Centre on Knee Angles during Cutting Movement (방향 전환 달리기 동작시 마커 정의에 따른 슬관절각 비교)

  • Park, Sang-Kyoon;Lee, Joong-Sook
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.3
    • /
    • pp.19-31
    • /
    • 2006
  • 이 연구의 목적은 각 분절의 마커세트와 무릎관절 중심 정의가 3차원 무릎 관절각을 산출하는데 얼마나 민감하게 영향을 미치는지를 연구하였다. 자료수집은 1명을 실험대상자로 하여 두 가지 형태의 각기 다른 분절의 정의와 무릎관절의 중심을 나타내는 반사마커들을 동시에 오른쪽 하지에 부착시켜 실험을 실시하였다. 실험대상자의 달리기동작 중 좌측으로 45도 방향전환동작의 지지기를 분석하였다. 이를 위해서 8대의 고속카메라들을 이용하였고 달리기속도는 4m/$sec{\pm}(10%)$로 통제하였다. 하지분절의 발분절에는 하나의 마커세트를, 정강이와 대퇴분절에는 두 가지의 다른 마커세트들을 부착시켰다. 발분절에는 3개의 마커를 신발의 뒷부분에 부착하였고 정강이분절을 정의하기 위하여 첫 번째 마커세트는 경골을 중심으로 3개의 마커들을 두 번째 마커세트는 비골을 중심으로 3개의 마커를 부착하였다. 대퇴분절의 마커세트를 정의하기 위하여 첫 번째 마커세트에는 대퇴골을 중심으로 3개의 마커를 두 번째 마커세트에는 대퇴근육을 중심으로 3개의 마커들을 부착하였다. 무릎관절중심을 정의하는데 두 가지 다른 정의가 적용되었다. 첫 번째 무릎중심을 무릎의 내측과 외측의 마커들을 통해 두 마커의 중심을 무릎관절의 중심으로 정의하였다. 두 번째 무릎중심정의는 무릎의 외측부분과 슬개골의 중심에 부착된 마커들로부터의 교차점을 무릎관절중심으로 산출하였다. 무릎관절의 각도를 산출하기 위해서 JCS(Joint Coordinate System)의 정의가 적용되었고 연구의 결과는 다음과 같았다. 두 가지의 다른 분절마커세트 사이에서 무릎의 신전(extension)과 굴곡(flexion)은 유사한 형태를 나타냈으며 최대 무릎굴곡(peak knee flexion)각에서 $4.746^{\circ}$의 차이를 나타냈다. 다른 분절마커세트 사이의 회전(rotation)각과 내전(adduction)/외전(abduction)에서는 서로 다른 형태를 나타내었고, 두 마커세트간 최대무릎외측회전(peak knee external rotation)각도에서는 $15.628^{\circ}$의 차이를 나타냈다. 또한, 각 분절마커세트 내에서 두 가지의 다른 무릎관절 중심의 정의가 얼마나 무릎도 산출에 영향을 미치는지를 비교했을 때 무릎의 최대외측회전(peak external rotation)각에서 차이를 나타내었다. 첫 번째 분절마커세트의 무릎관절중심정의의 형태변화에 따라 최대외측회전각은 $0.549^{\circ}$의 차이를 나타냈고, 두 번째 분절마커 세트에서 무릎관절중심정의의 형태변화에 따라 최대외측회전각은 $0.309^{\circ}$의 차이를 나타냈다. 이와 같이 분절을 나타내는 마커세트와 무릎관절중심정의의 형태변화에 따라 무릎간을 계산하는데 있어서 결과가 다르게 산출되었다. 즉, 관절각의 계산이 분절에 부착되는 마커의 정의 혹은 위치에 매우 민감하게 영향을 받았다. 따라서 연구자가 여러 실험대상자들을 대상으로 실험시 마커세트 혹은 마커들을 동일한 위치에 가깝게 부착하는 것이 마커부착으로부터 발생하는 실험오차를 줄일 수 있을 것이다.

Characterization of Surfaces by Contact Angle Goniometry - I. Contact Angle Measurement by Laser Beam Projection- (접촉각측정에 의한 표면의 특성연구 - I. 레이저광선 투영에 의한 접촉각의 측정방법-)

  • Park Chung Hee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.15 no.1
    • /
    • pp.70-75
    • /
    • 1991
  • Contact angle measuring device was developed in this laboratory using laser beam projec-tion. The new method allows for rapid and direct determination of stationary, advancing, and receding contact angles on both planar and nonplanar solid surfaces, including fibers with very small diameters. A narrow laser beam impinges on an edge of an interface of liquid and solid. This makes two projected laser beam lines upon and radiating from the center of a protractor scale on a tangent screen. Contact angle is measured by determining the difference in angle on the protractor scale between the two projected laser beam lines. Contact angles measured on Perspex-CQ using this instrument were in agreement with the literature. it was shown that this instrument provides a novel method for the facile and accurate measurement of contact angles.

  • PDF

Control of an Artificial Arm using Flex Sensor Signal (굽힘 센서신호를 이용한 인공의수의 제어)

  • Yoo, Jae-Myung;Kim, Young-Tark
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.17 no.6
    • /
    • pp.738-743
    • /
    • 2007
  • In this paper, a muscle motion sensing system and an artificial arm control system are studied. The artificial arm is for the people who lost one's forearm. The muscle motion sensing system detect the intention of motion from the upper arm's muscle. In sensing system we use flex sensors which is electrical resistance type sensor. The sensor is attached on the biceps brachii muscle and coracobrachialis muscle of the upper arm. We propose an algorithm to classify the one's intention of motions from the sensor signal. Using this algorithm, we extract the 4 motions which are flexion and extension of the forearm, pronation and supination of the arm. To verify the validity of the proposed algorithms we made experiments with two d.o.f. artificial arm. To reduce the control errors of the artificial arm we also proposed a fuzzy PID control algorithm which based on the errors and error rate.

전시회 - 한국만화 100년전

  • Park, Seong-Gwon
    • 프린팅코리아
    • /
    • v.8 no.7
    • /
    • pp.112-113
    • /
    • 2009
  • 한국만화 100년을 조망하는 대규모 기획전시 '만화-한국만화100년'전이 한국만화100주년 위원회(위원장 박재동.김동하.이동수.이홍우)와 국립현대미술관(관장 배순훈) 공동 주최로 국립현대미술관에서 오는 8월 23일까지 개최된다. 이번 전시는 굴곡진 한국 근 현대사와 함께 한 '한국만화 100년의 역사', 풍성한 문화콘텐츠로 발전을 거듭해온 '장르만화', 만화의 예술적 가능성을 살펴본 '크로스오버-미술과 만화의 경계 너머' 등 세 구역으로 나뉘어 진행된다. 또한 한국만화의 각 시대를 대표하는 250여명의 작품 1500여점, 만화적 감성과 상상력으로 작업하는 현대미술작품 60여점이 전시되고 있다.

  • PDF

Flexural strength of various kinds of the resin bridges fabricated with 3D printing (3D 프린팅으로 제작된 여러 종류의 레진브릿지의 굴곡강도에 대한 연구)

  • Park, Sang-Mo;Kim, Seong-Kyun;Park, Ji-Man;Kim, Jang-Hyun;Jeon, Yoon-Tae;Koak, Jai-Young
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.4
    • /
    • pp.260-268
    • /
    • 2017
  • Purpose: Manufacturing with AM (Additive manufacturing) technique has many advantages; but, due to insufficient study in the area, it is not being widely used in the general clinic. In this study, differences of flexural strength among various materials of 3 unit fixed dental prosthesis were analyzed. Materials and Methods: A metal jig for specimens that had a 3-unit-fixed dental prosthesis figure were fabricated. The jigs were made appropriately to the specifications of the specimens. Three different kinds of materials of specimens which were NC (mathacrylic esther based), DP-1 (Bisphenol A epoxy acrylate type oligomer based), and DT-1 (urethane acrylate based) were printed with DLP machine. Five specimens for each kind of material were printed with an angle of $30^{\circ}$ from the horizontal surface. The specimens were placed on the jig and the flexural strength was measured and recorded using Universal testing machine. The recorded data was analyzed in SPSS using One-way ANOVA and Tukey HSD to determine the significance of the differences of flexural strength among the groups. Results: The flexural strengths of each group were the followings: NC, $1119{\pm}305$ N; DP-1, $619{\pm}150$ N; DT-1, $413{\pm}65N$. Using One-way ANOVA and Tukey Honestly Significant Difference test, significant difference was found between NC and the other groups (P < 0.05), but there was no significant difference between DP-1 and DT-1 (P > 0.05). Conclusion: Higher flexural strength was shown in 3-unit-fixed dental prosthesis that were 3D printed using a DLP machine with NC material.