A Study on Change of Plantar Fascia Thickness in Chronic Stroke Patient Based on Spasticity (만성 뇌졸중 환자에서 경직에 따른 족저근막의 두께 변화에 관한 연구)

  • Kim, Tae-Gon;Sim, Ki-Cheol;Kim, Kyung-Yoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.11
    • /
    • pp.5723-5729
    • /
    • 2013
  • The purpose of this study was to investigate the imbalance of muscle tone and frequent exposure to excessive gait training in patients with chronic spasticity due to stroke, the thickness of the plantar fascia to change and to evaluate. The subjects of this study was in 54 patients with chronic stroke from 18 patients Group I(MAS G0), 18 patients Group II(MAS G1), and 18 patients Group III(MAS G2) were selected. Measurement of clinical symptoms and physical examination, MAS(Modified Ashworth Scale), ultrasonographic, ROM(Range of Motion), VAS(Visual Analogue Scale), TUG(Timed Up and Go test) was measured. The study results were each group between the unaffected side and the affected side on plantar fascia thickness was statistically significantly thicker(p<.001). Each group between the unaffected side and the affected side on ankle dorsiflexion ROM was statistically significantly decrease(p<.001), VAS(p<.001), TUG(p<.001) statistically significantly increase(p<.001). In this study, the plantar fascia pathokinesiology ever presented by the contents of gait training in stroke patients is one of the information that you need to consider when presented.

Study on Anti-biofouling Properties of the Surfaces Treated with Perfluoropolyether (PFPE) (Perfluoropolyether (PFPE)로 처리된 표면의 생물오손 방지 특성 연구)

  • Park, Sooin;Kwon, Sunil;Lee, Yeongmin;Koh, Won-Gun;Ha, Jong Wook;Lee, Sang-Yup
    • Applied Chemistry for Engineering
    • /
    • v.23 no.1
    • /
    • pp.71-76
    • /
    • 2012
  • Biofouling by marine organisms such as algae and barnacles causes lots of significant problems in marine systems such as a rise of the maintenance-repair cost for the ship and the marine structures. In this work, a fluoropolymer, perfluoropolyether (PFPE), was applied as an anti-biofouling coating material that prevents the adhesion of marine organisms and facilitates the removal of them. Water contact angles of various surfaces were tested to examine the hydrophobicity of the PFPE-modified surface. The PFPE-modified surface showed the water contact angle of $64.5^{\circ}$ which is a remarkable rise from $46.7^{\circ}$ of amine-treated surface. When the substrate was treated with PFPE, the adhesion on the of the barnacle and other marine organisms were repressed around 15% by the enhanced hydrophobicity. In addition, the removal the of the adhered marine organisms were better comparing to that of the surface prepared by PDMS. Surfaces of the substrate treated by PFPE were characterized through physical and chemical methods to analyze the biofouling results. Degree of biomolecular adhesion to the substrate was quantified by the measurement the fluorescence intensity of marine organisms dyed with green fluorescence. PFPE is expected to be applicable not only to anti-biofouling systems but also to medical devices where the prevention of protein adhesion is required.

The Case Study on Thoraco-lumbar junction and Lumbo-sacral junction Transitional Zone Syndrome. (복합적으로 병발한 등-허리, 허리-엉치 이행부위 증후군에 대한 증례를 통한 고찰)

  • Hwang, Eun-Mi;Jung, Min-Gyu;Park, Young-Hoi;Keum, Dong-Ho
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.5 no.2
    • /
    • pp.113-125
    • /
    • 2010
  • Objectives: We have evaluated the effects of conservative treatment on one patient who was diagnosed to thoraco-lumbar junction and lumbo-sacral junction transitional zone syndrome. so, we investigate thoraco-lumbar junction and Jumbo-sacral junction tranzitional zone syndrome that was suggested by Maigne R. Methods : One patient was diagnosed as T12-L1 herinated intervetebral disc through MRI. We diagnosed the patient to transitional zone syndrome by symptoms and physical examination and used Acupuncture therapy, Cox technique to the patient. We measured Visual Analog Scale(VAS) before and after treatment. Results: After treating Acupuncture therapy, Cox technique in the case, We find out that the patient was improved. VAS score changed from 7 to 2 and physical examinations are improved. Conclusions: We improved the patient who had thoraco-lumbar junction and lumbo-sacral junction transitional zone syndrome by Cox technique and Acupuncture therapy, and we found that thoraco-lumbar junction related lumbo-sacral junction.

  • PDF

PHYSICAL PROPERTIES OF DIFFERENT SELF-ADHESIVE RESIN CEMENTS AND THEIR SHEAR BOND STRENGTH ON LITHIUM DISILICATE CERAMIC AND DENTIN (수종의 자가 접착 레진 시멘트의 물성 및 lithium disilicate ceramic과 상아질에 대한 전단결합강도 비교)

  • Shin, Hye-Jin;Song, Chang-Kyu;Partk, Se-Hee;Kim, Jin-Woo;Cho, Kyung-Mo
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.3
    • /
    • pp.184-191
    • /
    • 2009
  • The purpose of this study was to evaluate the physical properties of different self-adhesive resin cements and their shear bond strength on dentin and lithium disilicate ceramic and compare these result with that of conventional resin cement. For this study, four self-adhesive resin cements (Rely-X Unicem, Embrace Wetbond, Mexcem, BisCem), one conventional resin cement (Rely-X ARC) and one restorative resin composite (Z-350) were used. In order to evaluate the physical properties, compressive strength, diametral tensile strength and flexural strength were measured. To evaluate the shear bond strength on dentin, each cement was adhered to buccal dentinal surface of extracted human lower molars. Dentin bonding agent was applied after acid etching for groups of Rely-X ARC and Z-350. In order to evaluate the shear bond strength on ceramic, lithium disilicate glass ceramic (IPS Empress 2) disks were prepared. Only Rely-X ARC and Z-350 groups were pretreated with hydrofluoric acid and silane. And then each resin cement was adhered to ceramic surface in 2 mm diameter. Physical properties and shear bond strengths were measured using a universal testing machine. Results were as follows 1. BisCem showed the lowest compressive strength, diametral tensile strength and flexural strength. (P<0.05) 2. Self-adhesive resin cements showed significantly lower shear bond strength on the dentin and lithium disilicate ceramic than Rely-X ARC and Z-350 (P<0.05) In conclusion, self-adhesive resin cements represent the lower physical properties and shear bond strength than a conventional resin cement.

Exposure to Dithiopyr Alters Swimming Performance Parameters in Zebrafish (Dithiopyr에 노출이 zebrafish의 유영 행동에 미치는 영향)

  • Oh, Junyoung;Park, Eun-Jin;Kang, Seongeun;Lee, Seungheon
    • Journal of Life Science
    • /
    • v.26 no.2
    • /
    • pp.181-189
    • /
    • 2016
  • The aim of this study was to identify the effects of dithiopyr (DTP), a herbicide, on behavior in zebrafish. The toxicity of DTP has rarely been investigated in fish. In the present study, zebrafish were exposed to different concentrations of DTP in the range of 10-20 μM for 48 h in a test container, in order to measure the value of median lethal concentrations (LC50). Behavioral experiments were performed, including the novel tank test (NTT) and the open field test (OFT), to assess stress responses or locomotion. After exposure to the DTP solution at a sublethal concentration of 2.5–10 μM for 6 min, the behavior of the zebrafish was observed for 6 min. In the acute toxicity test, the LC50 value of DTP showed as 14.49 μM in the zebrafish. The NTT showed that the duration of immobility and the velocity were significantly increased by exposure at a concentration of 5 μM of DTP, compared with a control group (p<0.05). However, compared with the control group, DTP significantly decreased the distance moved and the frequency at the top of the tank, and significantly increased the turn angle and duration at the bottom, in a concentration-dependent manner (p<0.05). In addition, in the OFT, exposure to DTP significantly decreased the distance moved and velocity compared with the control group (p<0.05). Exposure to DTP also significantly increased the duration of immobility, the turn angle, and the meandering movement, in a concentration-dependent manner (p<0.05). Further, exposure to DTP at a low concentration elevated whole-body cortisol levels in the zebrafish. The results of this study thus suggest that DTP induces a toxic response and negative effects on behavior and the endocrine system in zebrafish.

A taxanomic study on sections Foetidae, Arenariae, and Multiflorae of Carex L. in Korea(Cyperaceae) (한국산 사초속 진퍼리사초절, 까락사초절과 괭이사초절에 관한 분류학적 연구)

  • Oh, Yong Cha;Kim, Ji Hye
    • Korean Journal of Plant Taxonomy
    • /
    • v.32 no.3
    • /
    • pp.257-292
    • /
    • 2002
  • Morphological characters of sections Foetidae(one taxon), Arenariae(one taxon) and Multiflorae(six taxa) of genus Carex(Cyperaceae) were reexamined. The epidermal patterns of perigynium, achene and leaf were investigated using by a scanning electron microscope(SEM) and a light microscope(LM). Morphological characters, such as length and width of stem, leaf, leaf sheath, bract, spike, scale, perigynium and beak of perigynium, length of spike peduncle, size and frequency of stomatal complex of leaf, number of bract, shape of stem transection, scale and apex of scale, beak and base of perigynuim, achene, epidermal cell and cell wall of perigynium, achene, leaf epidermal patterns(fundamental epidermal cell and cell wall, silica body, subsidiary cell), hair, papillae present/absent of perigynium, and leaf were useful for the identification of observed eight taxa. According to the current study, examined eight taxa of sections Foetidae, Arenariae and Multiflorae were distinct from each other with respect to length and width of stem, leaf, bract, perigynium, perigynium beak, length of spike peduncle, shape of bract, scale and apex of scale, perigynium, perigynium beak, hair presence/absence of perigynium and leaf. A key based on data was presented here.

Low-cost Prosthetic Hand Model using Machine Learning and 3D Printing (머신러닝과 3D 프린팅을 이용한 저비용 인공의수 모형)

  • Donguk Shin;Hojun Yeom;Sangsoo Park
    • The Journal of the Convergence on Culture Technology
    • /
    • v.10 no.1
    • /
    • pp.19-23
    • /
    • 2024
  • Patients with amputations of both hands need prosthetic hands that serve both cosmetic and functional purposes, and research on prosthetic hands using electromyography of remaining muscles is active, but there is still the problem of high cost. In this study, an artificial prosthetic hand was manufactured and its performance was evaluated using low-cost parts and software such as a surface electromyography sensor, machine learning software Edge Impulse, Arduino Nano 33 BLE, and 3D printing. Using signals acquired with surface electromyography sensors and subjected to digital signal processing through Edge Impulse, the flexing movement signals of each finger were transmitted to the fingers of the prosthetic hand model through training to determine the type of finger movement using machine learning. When the digital signal processing conditions were set to a notch filter of 60 Hz, a bandpass filter of 10-300 Hz, and a sampling frequency of 1,000 Hz, the accuracy of machine learning was the highest at 82.1%. The possibility of being confused between each finger flexion movement was highest for the ring finger, with a 44.7% chance of being confused with the movement of the index finger. More research is needed to successfully develop a low-cost prosthetic hand.

Analysis of alveolar molding effects in infants with bilateral cleft lip and palate when treated with pre-surgical naso-alveolar molding appliance (양측성 순구개열 신생아 환자의 수술전 비치조 정형장치 치료에 의한 치조골 조형(molding) 효과의 분석)

  • Nahm, Dong-Seok;Yang, Won-Sik;Baek, Seung-Hak;Kim, Sukwha
    • The korean journal of orthodontics
    • /
    • v.29 no.6 s.77
    • /
    • pp.649-661
    • /
    • 1999
  • The goals of this study were 1) to present pre-surgical naso-alveolar molding (PNAM) appliance for bilateral cleft lip and palate treatment and 2) to evaluate the effects of the PNAM appliance on the alveolar molding of the premaxilla and the lateral segments. Subjects consisted of 8 bilateral cleft lip and palate infants (7 males and 1 female, mean age at first visit = 61.6 days after birth) who were treated with PNAM appliances in Department of Orthodontics, Seoul National University Dental Hospital. Average alveolar cleft gap between the premaxilla and the lateral segment was $8.09{\pm}5.03mm$ and average duration of alveolar molding treatment was $8.8{\pm}3.1$ weeks. These patients' models were obtained at initial visit (T0) and after alveolar molding (T1). 20 linear and 14 angular variables were measured by using photometry and digital caliper, All statistical analyses were performed by Microsoft Excel 97 program. Paired t-test was used to discriminate the effect of alveolar molding by PNAM appliance. 1. Closure of the alveolar cleft gap in bilateral cleft cases by molding therapy was completed successfully, 2. Alveolar molding inhibited outward growth of lateral segments and produced inward bending of lateral segments. 3. By bending the anterior part of the vomer, the premaxilla could be rotated and moved. posteriorly via alveolar molding. Conclusion This appliance can be applied to bilateral cleft lip and palate infants with satisfactory results before cheiloplasty.

  • PDF

The Kinematics Analysis of the Badminton High Clear Motion in Woman Middle School Student (여자중학생 배드민턴 하이클리어 동작의 운동학적 분석)

  • Kim, Chang-Bum;Ryu, Jae-Kwang
    • Korean Journal of Applied Biomechanics
    • /
    • v.12 no.2
    • /
    • pp.91-107
    • /
    • 2002
  • This research got the following conclusion as result that analyzed high clear action kinematically to 4 C girls' junior high school badminton players who are situated in Chungchong-bukdo. 1. Most of the subject didn't rotate their right shoulder and elbow joint at back swing and moved speedy to shuttle cock. And an cooperation action of joint decreases displaying only a good action on both subject`s specification joint part. 2. When the subject S1 and S2 swing slowly and largely the joint of shoulder and elbow and then the speed of right wrist and racket head is fast, the cooperation action of joint is better than other subject. 3. An angle change of right shoulder showed angle that all subjects are great being caused in softness of joint and angular velocity was exposed that load enough Impact force and increase the speed of racket head as angular velocity decreases rapidly in Impact except subject S3. 4. All subjects of right elbow angle change showed similar form and was exposed that subject S2 sees form of impact stage serious bends from back swing and do not use force effectively in angular velocity. 5. Angle of right wrist appeared that the speed of shuttle cock is decelerated because fast bends of wrist is not formed shortly after Impact because all subject do not accomplish big angle shortly after back swing. Angular velocity can assume that the subject S1 and S4 are using and move fast strong snap shot offering angular velocity value of Impact stage sound (-). 6. While size of Impact stage knee angle accomplishes angle that is big both subject, hip joint angles sees small angle and is playing swing that do on upper body and arm without using strong waist force that is composition action with knee and hip joint.

Autograft Versus Allograft Bone-Patellar Tendon-Bone in Anterior Cruciate Ligament Reconstruction - A Comparison Of Mid-Term Follow-Up Results - (자가 및 동종 골-슬개건-골을 이용한 전방 십자 인대 재건술 -중기 추시 결과의 비교-)

  • Cho, Sung-Do;Cho, Su-Hyun;Woo, Jong-Ken;Yoo, Chang-Hyun;Park, Moon-Su;Lew, Sog-U
    • Journal of the Korean Arthroscopy Society
    • /
    • v.8 no.1
    • /
    • pp.14-18
    • /
    • 2004
  • Purpose: To compare the mid-term follow-up results of anterior cruciate ligament(ACL) reconstruction with the bone-patellar tendon- bone(BTB) autograft to those with the BTB allograft. Materials and Methods: Retrospective study was performed in 59 cases with BTB autograft and 42 cases with BTB allograft. Evaluations include Lysholm score, 2000 IKDC subjective knee score, Shelbourne patello-femoral pain score , Lachman test, pivot shift test, KT-1000 arthrometer test and 2000 IKDC knee examination. Results: There were no significant statistic differences between two groups in Lysholm score and 2000 IKDC subjective knee score of more than 70 (p<0.05). Five cases(8.5%) showed the patello-femoral pain score less than 80 according to Shelboume with autograft group and two cases(4.8%) with allograft group (p<0.05). Lachman test, pivot shift test and KT-1000 arthrometer test showed no significant statistic differences between two groups(P<0.05). Fifty-four cases(91.5%) were normal or nearly normal according to the 2000 IKDC knee examination with autograft group and thirty-eight cases(90.4%) with allograft group(p<0.05).Conclusion: BTB allograft as well as BTB autograft is considered to be an acceptable choice for ACL reconstruction.

  • PDF