• Title/Summary/Keyword: 국제시험표준

Search Result 339, Processing Time 0.028 seconds

Test Standard for Reliability of Automotive Semiconductors: AEC-Q100 (자동차 반도체의 신뢰성 테스트 표준: AEC-Q100)

  • Lee, Seongsoo
    • Journal of IKEEE
    • /
    • v.25 no.3
    • /
    • pp.578-583
    • /
    • 2021
  • This paper describes acceleration tests for reliability of semiconductors. It also describes AEC-Q100, international test standard for reliability of automotive semiconductors. Semiconductors can be used for dozens of years. So acceleration tests are essential to test potential problems over whole period of product where test time is minimized by applying intensive stresses. AEC-Q100 is a typical acceleration test in automotive semiconductors, and it is designed to find various failures in semiconductors and to analyze their causes of occurance. So it finds many problems in design and fabrication as well as it predicts lifetime and reliability of semiconductors. AEC-Q100 consists of 7 test groups such as accelerated environmental stress tests, accelerated lifetime simulation tests, package assembly integrity tests, die fabrication reliability tests, electrical verification tests, defect screening tests, and cavity package integrity tests. It has 4 grades from grade 0 to grade 3 based on operational temperature. AEC-Q101, Q102, Q103, Q104, and Q200 are applied to discrete semiconductors, optoelectronic semiconductors, sensors, multichip modules, and passive components, respectively.

Establish data collection and management system for successful clinical trials of korean medicine (한의학의 성공적인 임상시험을 위한 데이터 수집 및 관리 체계 구축)

  • So, Ji-Ho;Jeon, Young-Ju
    • The Journal of the Convergence on Culture Technology
    • /
    • v.4 no.4
    • /
    • pp.387-392
    • /
    • 2018
  • Clinical trials are an important part of developing new medical devices or developing new drugs. However, it takes many time and expense to conduct clinical trials. In order to solve this problem, it define the standard format of the data collected in clinical trials in major countries and in Korea. Clinical trials are also underway in korean medicine to develop new medical devices. If it define the standards for the data we collect in clinical trials, there are likely to be a variety of ways to use them. If it collect and manage various clinical trial data as one standardized data, you will be able to draw various results. Based on these findings, we established a system for collecting and managing integrated data on clinical trials. And let's look at how to use it.

Application of the Ecotoxicological Standard Method using Population Growth Inhibition of Marine Phytoplankton (식물플랑크톤의 개체군성장저해율을 이용한 해양생태독성 시험방법에 관한 연구)

  • Lee, Sung-Min;Park, Gyung-Soo;An, Kyoung-Ho;Park, Soung-Yun;Lee, Sang-Hee
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.13 no.2
    • /
    • pp.112-120
    • /
    • 2008
  • A series of experiments were conducted to establish a marine ecotoxicological standard method using marine primary producers, Skeletonema costatum, Heterosigma akashiwo, Prorocentrum micans, Isochrysis galbana, Tetraselmis suecica as candidate test species. Marine diatom, S. costatum was selected as standard test species in terms of the ecological roles and international uses as test species. Test methods and test acceptability criteria are as follows; $72{\sim}96$ hr population growth inhibition $EC_{50}$ as endpoint. Static non-renewal method, and population growth rates over 0.04/hr in control as test acceptability criterium. S. costatum is widely distributed in the world ocean and used for standard species of marine toxicity test method by ISO (International Standardization Organization). Possible salinity ranges for this test method are $20{\sim}35\;psu$, and reproducibility and interlaboratory test results were consistent through the calibration tests. Sensitivity of the test method was comparable or better than other toxicity tests such as rotifer neonate mortality, bioluminescent bacterial inhibition, seaweed sporulation and sea urchin fertilization tests.

Construction of AC-DC Magnetic Field Standard Systems and Results of International Key Comparison (직류-교류 자기장 표준 시스템 제작 및 국제비교 결과)

  • Park, Po-Gyu;Kim, Young-Gyun
    • Journal of the Korean Magnetics Society
    • /
    • v.14 no.6
    • /
    • pp.201-206
    • /
    • 2004
  • The AC-DC magnetic field standard systems were constructed for the calibration of magnetometers for low magnetic field and the tests for low magnetic field characteristics of sensors and materials. In the range of 1 mT, the expanded uncertainty of dc is 8${\times}$10$\^$-6/, ac uncertainties are 0.16% in 0.1~1 kHz, 0.26% in 1~5 kHz, and 0.44% in 5~20 kHz. We have been participated in international key comparison(KC) to achieve the equality and the mutual agreement between standard institutes for the results of calibrations and tests. KRISS participating in ac-dc magnetic flux density of KC got equal level of uncertainty results compare with the advanced nations. It confirm that measurement ability of magnetic flux density is high level in the world.

Assessment of Liquefaction Potential on Non-Plastic Silty Soil Layers Using Geographic Information System(GIS) and Standard Penetration Test Results (지리정보시스템 및 표준관입시험 결과를 이용한 비소성 실트질 지반의 액상화 평가)

  • Yoo, Si-Dong;Kim, Hong-Taek;Song, Byung-Woong;Lee, Hyung-Kyu
    • Journal of the Korean GEO-environmental Society
    • /
    • v.6 no.2
    • /
    • pp.5-14
    • /
    • 2005
  • In the present study, the liquefaction potential in the area of the Incheon international airport was assessed by applying the data of both standard penetration tests and laboratory tests to the modified Seed & Idriss method. The analysis was performed against the non-plastic silty soil layer and silty sand soil layer existing within the depth of 20m and under the ground water level, having the standard penetration value(N) of below 20. Also, each set of data was mapped using the GIS(Geographic Information System) and the safety factor against the liquefaction potential ($FS_{liquefaction}$) was obtained by overlapping those layers. Throughout the analysis, it was found that there exists a potential hazard zone for the liquefaction, showing partially that the safety factor against the liquefaction potential is 1.0 to 1.5 below the standard safety factor criterion. It is further thought to be necessary that the liquefaction potential for the corresponding hazard zone be additionally assessed in detail.

  • PDF

Testing in GNSS RTK of ISO standard 17123-8 (ISO17123-8 GNSS RTK 규격의 시험연구)

  • Lee, Young-Jin;Jo, Jun-Rae;Ryu, Su-Hyun;Jung, Rae-Jung
    • Proceedings of the Korean Association of Geographic Inforamtion Studies Conference
    • /
    • 2008.10a
    • /
    • pp.352-353
    • /
    • 2008
  • 국제표준화기구(ISO)에서는 장비에 대한 표준화작업을 ISO/TC172에서 관리하고 있으며 산하의 전문위원회인 SC6에 속해있는 ISO17123 $1{\sim}8$은 주로 측량장비의 정밀도를 참조할 때 인용되는 표준으로 그중에서 ISO17123-8: GNSS field measurement systems in real-time kinematic(RTK)은 GNSS의 RTK 정확도평가방법으로서 약식시험절차와 엄밀시험절차를 규정하고 있다. 본 연구에서는 ISO17123-8의 규격을 분석하고 이 규격에 따라 GPS RTK Test-bed를 시험구축하고 정확도 평가방법에 따라 관측값 Testing하는데 목적이 있다.

  • PDF

Study on Quality Evaluation Model of Bio Information Processing Software (바이오 정보처리 소프트웨어 품질평가 모델 연구)

  • Jeon, Min-Ho;Yang, Hae-Sool
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.3
    • /
    • pp.601-614
    • /
    • 2007
  • Lately, as importance of biometric is recognized, domestic and foreign biometric software market is soaring and the requests of high reliability and quality of biometric software are inclosed. Evaluation items and criteria must be established for the biometric software quality certification. In this paper, we development the evaluation module for biometric software test based on ISO/IEC 12119 that is the standard about package software quality requirement and test, and ISO/IEC 9126 that is the standard about evaluation of software product, and ISO/IEC 14598-6 that is the standard for construction of the evaluation module. We think that this study can be used in establishing the software quality evaluation method of bio information processing software and constructing the basis for quality improvement.

  • PDF

Testing Application of Web Processing Service (WPS) Standard to Satellite Image Processing (웹 처리 서비스(WPS) 표준의 위성영상 정보처리 시험 적용)

  • Yoon, Gooseon;Lee, Kiwon
    • Korean Journal of Remote Sensing
    • /
    • v.31 no.3
    • /
    • pp.245-253
    • /
    • 2015
  • According to wide civilian utilization of multi sensor satellite information, practical needs for fusion processing and interoperable operation with multiple remote sensing imageries within distributed remote server are being increased. For this task, OGC standards with respect to satellite images and its derived products are crucial factors. This study is to present an applicability of WPS through testing implementation of image processing algorithm. Open sources such as Geoserver and OTB were used linked to WPS application for implementation. WPS can be solely used for web service supporting geoprocessing algorithm, but technical consideration compromising with other important standard protocols including WMS, WFS, WCS, or WMTS is necessary to build full featured geo web for remote sensing imageries. It is expected that application of these international standards for geo-spatial information is an important approach to produce value-added results by interoperable processing between interorganizations or information dissemination containing practical satellite image processing functionalities.

Proficiency testing of cadmium and lead in polypropylene resin (폴리프로필렌 수지 중 카드뮴과 납 측정 숙련도시험)

  • Cho, K.H.;Lim, M.C.;Min, H.S.;Han, M.S.;Song, H.J.;Park, C.J.
    • Analytical Science and Technology
    • /
    • v.20 no.3
    • /
    • pp.183-192
    • /
    • 2007
  • The various environmental regulation directives such as RoHS (restriction of hazardous substances in electrical and electronic products) and WEEE (waste from electrical and electronic equipments) are practically used as the technical barrier in international trade (TBT) of vehicles and electrical and electronic products recently. Regarding such an environmental regulation, Korea Research Institute of Standards Science (KRISS) organized a proficiency testing scheme to establish the reliability of measurement results produced by the relevant research institutes and test laboratories in Korea. Participants were 31 laboratories related to production of the electrical and electronic equipments and mobile vehicles. Two polypropylene samples of pellet type were employed as the proficiency testing materials (PTMs). Cadmium and lead were the analytes chosen among six components regulated in European Union (EU) RoHS directive. The PTMs were sent to the participants by post on September $1^{st}$ 2006, and deadline for results submission were October $10^{th}$ 2006. The results of each laboratory were evaluated in comparison with KRISS reference values using Robustic Z-score and Youden plot methods. The results of the various sample digestion methods were also compared. Most of participants reported good agreement within 10 % range of reference values. However, results from several laboratories showed significant biases from reference values. These laboratories should establish the quality assurance system for improvement of the measurement reliability.

Conformance Evaluation Method by Successively Applying Self-Running Test Mode in Active RFID Tag (능동형 RFID 태그에서 자체 시험 모드를 순차적으로 적용한 적합성 평가방법)

  • Song, Tae-Seung;Kim, Tae-Yeon;Lyou, Joon
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.45 no.6
    • /
    • pp.204-212
    • /
    • 2008
  • Active RFID tags are currently used in harbor transportation; they are attached to cargo containers for sea transportation. They are designed to be able to be identified by RFID readers installed at ports in many countries. The international standard ISO/IEC 18047-7 regarding RFID conformance test methods suggests the use of air interface evaluation between an RFID reader and a tag. However, the test method suggested by the international standard is intended to detect a radio signal over only a very short period. Outcomes were uncertain, making it difficult to evaluate the system accurately. This paper proposes a new evaluation method by incorporating a 'self-running test mode' environment into the RFID tags in order to reduce the test time and increase testing accuracy. We found that the application of the suggested method to actual tags improves measurement time and uncertainty over that obtained using existing methods.