• Title/Summary/Keyword: 국부하중

Search Result 355, Processing Time 0.031 seconds

Damage Curves for the Shear Building to the Local Impact (국부충격에 의한 전단건물의 손상곡선)

  • Lee, Sang-Ho;Hwang, Sin-Woo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.8 no.4
    • /
    • pp.247-256
    • /
    • 2004
  • The damage curves for the 2-story shear building to the impulsive rectangular loads were established with the peak load and Impulse ratio producing the critical displacement. The convolution integrations with the Impulse response matrix and the loads were used to find the responses of the building. The impulse response matrix required in the calculations of the convolution integration were found with the mode superposition method It is shown from the established damage curves that the responses of the top and bottom floor are sensitive to the magnitude and the impulse of the loads respectively.

The Mechanical Behavior of Steel Circular Caisson by Horizontal Load (水平載荷에 따른 鋼製圓筒 케이슨의 力學的 擧動)

  • 장정욱
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.10 no.3
    • /
    • pp.141-150
    • /
    • 1998
  • Model tests were performed to examine the mechanical behavior of steel circular caisson by horizontal load. It was generally found that displacements and bottom pressure of the caisson model were increased rapidly at the local plastic load. The maximum displacement was measured at the loading point, whereas the less displacement was measured at the upper part of the caisson model. The bottom pressure was getting higher, as it was nearer the loading side. Furthermore, the increase ratio of the bottom pressure was higher as the load was increased.

  • PDF

한국전력공사 전력연구원 "BOX 구조물자동화 설계시스템(BOXCAD)"에 대한 소개

  • 송영철;우상균
    • Computational Structural Engineering
    • /
    • v.10 no.2
    • /
    • pp.34-39
    • /
    • 1997
  • BOXCAD Vㄷㄱ.2.00의 개발을 통하여 얻은 결론은 다음과 같다. 1) 다양한 설계조건 즉 설계차량하중, 토피, 지하수위, 사용재료의 강도 등의 변화에도 쉽게 자동화설계가 가능하도록 설계시스템이 개발되었다. 2) 개발된 설계시스템은 도로교 표준시방서와 콘크리트 시방서의 하중계수에 의한 방법을 모두 포함하고 있으며, 설계시방서에 따른 변화에도 신속하고 용이하게 대처할 수 있도록 개발되었다. 3) 개발된 본 설계시스템에 국부적인 기하조건, 설계하중, 구조세목만 보완하면 전력구 외에도 발전소의 배수 BOX구조, 도로 및 철도 횡단용 BOX구조, 지하차도 및 보도, 하수도 및 배수 BOX구조, 분류하수관거, 지하철 BOX구조 등의 자동화설계에도 작용할 수 있도록 시스템이 구축되었다. 4) 본 연구에서 개발된 자동설계시스템은 단면의 산정, 설계도면의 제작기능은 물론 설계 정보의 데이터베이스 기능이 있으므로, 실무에서 활용할 경우 설계도면 재료량 산출 및 설계정보의 효율적인 관리가 가능할 것으로 사료된다.

  • PDF

A Study of the Link Strength Design of Converter Suspension System (전로 지지장치 접합부 강도설계에 관한 연구)

  • Lee, Man-Seung;Kim, Hyun-Bae
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2010.04a
    • /
    • pp.322-325
    • /
    • 2010
  • 철강 플랜트 주요 설비인 전로를 지지하는 장치의 접합부 강도설계를 위해 작용하중은 해석적인 방법으로 신뢰성 있게 계산하였고, 정적하중에 의한 응력은 ASME 규정에 따른 허용응력으로 평가하였다. 한편 피로설계 측면에서는 전로와 같은 대형 용접구조물은 강도상 취약부인 용접부에서 다양한 용접비드 형상에 따라 국부응력이 크게 달라지므로 설계단계에서 피로수명 평가에 어려움이 있었다. 따라서 전로 지지장치 접합부 피로설계는 설계단계에서 피로수명을 평가하는 실용적이고 안전측 방법으로 알려진 Hot Spot 응력을 사용하고 공신력을 갖는 설계규정인 ASME와 영국 PD 5500 절차에 의해 평가하였다. 평가결과 두 규정 모두 안전측에서 평가되는 것을 확인할 수 있었고 이 방법은 피로하중이 지배적인 대형구조물의 설계단계에서 유용한 방법으로 활용할 수 있으리라 판단된다.

  • PDF

Damage Estimation for Offshore Tubular Members Under Quasi-Static Loading (준정적하중(準靜的荷重)을 받는 해양구조물(海洋構造物)의 원통부재(圓筒部材)에 대한 손상예측(損傷豫測))

  • Paik, Jeom-K.;Shin, Byung-C.;Kim, Chang-Y.
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.26 no.4
    • /
    • pp.81-93
    • /
    • 1989
  • The present study attempts to develop the theoretical model for the damage estimation of offshore tubular members which are subjected to the accidental impact loads due to collision, falling objects and so on. For the reasons of the simplicity of the problem being considered, however, this paper postulates that the accidental load can be approximated to be the quasi-static one, in which dynamic effects are negelcted. Based upon the theoretical and experimental results which are obtained from the present study as well as the existing literature, the load-displacement relations taking the interaction effect between the local denting and the global bending deformation into account are presented in the explicit form when the concentrated lateral load acts on the tubular member whose end condition is supposed to be rotation ally free and axially restrained, in which membrane forces develop. Thus, the practical estimation of damage deformation for the local denting and the global bending damage of tubular members against the accidental loads is possible and also the collision absorption capability of the member can be calculated by performing the integration of the area below the given load-displacement curves, provided that all the energy is dissipated to the deforming the member itself.

  • PDF

Structural Analysis of Composite Sandwich Panel under Compression Loading (압축하중을 받는 복합재료 샌드위치 패널의 구조해석)

  • Kim, Kwang-Soo;Jang, Young-Soon
    • Aerospace Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.9-16
    • /
    • 2010
  • In this study, structural analyses were carried out on the composite sandwich panel which was tested under compression loading. In the structural analyses, three types of finite element modelling were considered and linear buckling analysis and nonlinear analysis were performed for each FE-model. Through the analyses, it was found that shell elements for face parts and solid elements for core part were appropriate for the better prediction of the buckling load of the panel. If the material failure of the face is critical than overall buckling of the sandwich panel, the use of one shell element through the thickness direction was suitable in the FE-model for the better predictions of failure location and failure load.

Evaluation of Local Effect Prediction Formulas for RC Slabs Subjected to Impact Loading (충격하중이 작용하는 RC 슬래브의 국부손상 산정식에 대한 고찰)

  • Chung, Chul-Hun;Choi, Hyun;Lee, Jung Whee;Choi, Kang Ryong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.6A
    • /
    • pp.543-560
    • /
    • 2010
  • Safety-related concrete structures in a nuclear power plant must be protected against the impact of flying objects, referred to in the profession as missiles. In practice, the structural verification is usually carried out by means of empirical formulas, which relate the velocity of the impinging missile to the wall thickness needed to prevent scabbing or perforation. The purpose of this study is to reevaluate the predictability of the local effect prediction formulas for the penetration and scabbing depths and perforation thickness. Therefore, available formulas for predicting the penetration depth, scabbing thickness, and perforation thickness of concrete structures impacted by solid missiles are summarized, reviewed, and compared. A series of impact analyses is performed to predict the local effects of the projectile at impact velocities varing from 95 to 215 m/s. The results obtained from the numerical simulations have been compared with tests that were carried out at Kojima to validate numerical modelling. The simulation results show reasonable agreement with the Kojima test results for the overall impact response of the RC slabs. From these results, it seems that the Degen equation give a very good estimate of perforation thickness against a tornado projectile for test data. Finally, the results obtained from the impact analysis have been compared with Degen formula to determine the perforation thickness of the RC slab.

Damage Monitoring for Wind Turbine Blade using Impedance Technique (임피던스 기법을 이용한 풍력 블레이드 손상 모니터링)

  • Huh, Yong-Hak;Kim, Jongil;Hong, Seonggu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.5
    • /
    • pp.452-458
    • /
    • 2013
  • Impedance based monitoring technique was investigated to evaluate the damage occurring in wind turbine blade. In this study, PVDF film piezo sensors were patched on the 10 kW wind turbine blade, and impedance was measured over the frequency range of 1~200 MHz under fatigue loading. With applying fatigue loads on the blade, change in maximum deflection of the blade and local strain values could be obtained from the strain gages attached on the blade, and difference of the impedance signatures was also observed. From these data, it could be found that local damage or geometrical change in the blade structure happened. To quantitatively compare the impedance signature patterns, a statistical algorithm, scalar damage metric M was used. It was calculated from the impedance signatures considering fatigue loads and location of the sensors. The metric values were compared to correlate the metrics with damage in the blade.

Vibration Fatigue Analysis for Multi-Point Spot-Welded SPCC Structure Considering Change of Dynamic Response (동적응답의 변화를 고려한 점용접부의 진동피로해석)

  • Kang, Ki-Weon;Chang, Il-Joo;Kim, Jung-Kyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.9
    • /
    • pp.1193-1199
    • /
    • 2010
  • Spot welding is the primary method of joining sheet metals in the automotive industry. As automobiles are subjected to fatigue loading, some spot welds may fracture before the whole system has failed. This local fracture of spot welds may lead to change in the dynamic response and consequently affect fatigue behavior of an automobile. Therefore, this change in dynamic response should be taken into consideration to assess the fatigue life of structures subjected to spectrum loading, such as automobiles. In this study, vibration fatigue analysis was performed by taking into consideration the change in the dynamic response due to accumulated damage at spot-welded parts. Fatigue tests were carried out on tensile-shear spot-welded specimens under constant amplitude loading condition. And the fatigue life of spot welds under spectrum loading was predicted using vibration fatigue analysis method based on finite element analysis.

Evaluating Local Damages and Blast Resistance of RC Slabs Subjected to Contact Detonation (접촉 폭발 하중을 받는 RC 슬래브의 국부 손상 및 내폭 성능 평가)

  • Li, Ling;Lee, Jin Young;Min, Kyung Hwan;Yoon, Young Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.1
    • /
    • pp.37-45
    • /
    • 2013
  • In this study, the resistance of various reinforced concrete (RC) slabs subjected to contact detonation was assessed. In order to enhance the blast resistance, fibers and external FRP sheets were reinforced to RC slabs. In the experiment, the $2,000{\times}1,000{\times}100mm$ sized RC slabs were fabricated using normal concrete (NC), steel fiber reinforced concrete (SFRC), polyvinyl alcohol fiber reinforced cementitious composite (PVA FRCC), and ultra-high performance cementitious composites (UHPCC). The damage levels of RC slabs subjected to contact detonation were evaluated by measuring the diameter and depth of crater, spall and breach. The experimental results were compared to the analyzed data using LS-DYNA program and three different prediction equations. The diameter and depth of crater, spall and breach were able to be predicted using LS-DYNA program approximately. The damage process of RC slabs under blast load was also well expressed. Three prediction equations suggested by other researchers had limitations to apply in terms of empirical approaches, therefore it needs further research to set more analytical considerations.