• Title/Summary/Keyword: 국부하중

Search Result 355, Processing Time 0.03 seconds

Strength Evaluation of Bolt Arrangement in PFRP Bolted Connection with 2 Bolts (2개의 볼트를 가지는 PFRP 볼트연결부의 볼트배치에 따른 강도평가)

  • Lee, Young-Geun;Kim, Sun-Hee;Won, Yong-Seok;Cheon, Jin-Uk;Shin, Kwang-Yeoul;Yoon, Soon-Jong
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.5 no.3
    • /
    • pp.17-22
    • /
    • 2014
  • Fiber reinforced plastic (FRP) structural shapes are readily available in civil engineering applications. Among many manufacturing techniques used for FRP structural shapes, pultrusion process is one of the most widely used techniques in civil engineering applications. Pultrusion is a manufacturing process for producing continuous lengths of reinforced polymeric plastic structural shapes with constant cross-section. Pultruded composites are attractive for structural applications because of their continuous mass production with excellent mechanical properties. This paper presents the results of investigations pertaining to the bolted connection with two bolts for the pultruded FRP (PFRP) structural members. PFRP bolted connection tests were conducted with end distance to bolt diameter ratio ($e_1/d_b$) and two types of bolt pattern such as horizontal (Pattern A) and vertical arrangement (Pattern B). As a result, it is found that the $e_1/d_b$ is recommended as the ratio of 4. In addition, it is also found that the bearing strengths at failure of the Pattern A and Pattern B have a similar value.

Three Dimensional Thermal-Elastic Plastic Analysis of GMAW Considering the Melting of Weld Bead (비드의 용용상태를 고려한 가스메탈 아크용접의 3차원 열탄소성 변형 해석)

  • Jang-Hyun Lee;Jong-Gye Shin;Ji-Hoon Kim
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.39 no.1
    • /
    • pp.49-60
    • /
    • 2002
  • Welding is essential in ship production since welding is very popular method for joining two or more metals. However, welding causes residual stress and distortion and these give a bad influence to the structure strength and assembly of ship blocks. Therefore, prediction and treatment of residual stress and distortion is a key to accuracy control in shipyard. In this paper, a computational procedure, based on thermal-elastic-plastic 3-dimensional FEA, has been suggested to simulate butt and fillet welding process. In the simulation process, temperature distribution at each time step is obtained by heat transfer analysis and then thermal deformation analysis is done with obtained temperature distributions to find the residual stress and distortion. In heat transfer analysis, enthalpy method is used to realize phase change at melting temperature. Also element birth and death method is used to simulate adding of weld metal in both heat transfer analysis and thermal elastic plastic analysis. The proposed procedure is verified by related researches and the results show good agreement with those of related researches.

Pounding Characteristics of a Bridge Superstructure on Rubber Bearings (교량 상부구조물의 탄성받침 설치에 따른 충돌특성 분석)

  • Choi, Hyoung-Suk;Kim, Jung-Woo;Gong, Yeong-I;Cheung, Jin-Hwan;Kim, In-Tae
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.15 no.4
    • /
    • pp.13-21
    • /
    • 2011
  • Seismic structure pounding between adjacent superstructures may induce the destruction of pier and bridge superstructures and cause local damage that leads to the collapse of the whole bridge system. The pounding problem is related to the expansion of joints, gap distance and seismic response of the abutments. In this research, methods of the contact element approach, the linear spring model, the Kelvin-Voigt model and the Hertz model were studied to analyse the pounding characteristics. The shaking table test for a model specimen such as a bridge superstructure with elastomeric bearings was performed to evaluate the contact element approach methods. Relationships between the time history response from the numerical analysis results and the measured response from the shaking table test are compared. The experimental results were not well matched with the numerical analysis results using the existing pounding stiffness models. Therefore, in this study, coefficients are proposed to calculate the appropriate pounding stiffness ratio.

Assessment of Shear Band Characteristics in Granular Soils Using Digital Image Analysis Technique for Plane Strain Tests (평면변형률 시험에서 이미지 해석을 통한 사질토의 전단면 특성 평가)

  • Jang, Eui-Ryong;Jung, Young-Hoon;Kim, Jun-Young;Chung, Choong-Ki
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.4
    • /
    • pp.51-65
    • /
    • 2011
  • Shear banding, the localization of deformation into thin zones, has a quite practical relevance, as stability and deformation characteristics of earth structures are controlled by the soil behavior within the shear band. In this study, for understanding occurrence and developed pattern of shear band, plane strain compression tests were performed on three soils with different particle-size distribution under various conditions. Digital images were captured during the experiments; then, deformation of a specimen was evaluated by digital image analysis technique. The characteristics of a shear band were evaluated from the state shortly after post-peak occurrence to critical state. Additionally, the statistical procedure was developed to determine the reasonable thickness of a shear band.

Seismic Behavior of Nonseismically Detailed Reinforced Concrete Beam-Column Joints (비내진 상세를 가진 RC 보-기둥 접합부의 지진 거동)

  • Woo, Sung-Woo;Lee, Han-Seon
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.6
    • /
    • pp.894-901
    • /
    • 2003
  • The objective of this study is to clarify the seismic capacity and the characteristics in the hysteretic behavior of RC structures with non-seismic detailing. Interior and exterior beam-column subassemblages were selected from a ten-story RC building and six 1/3-scale specimens were constructed with three variables; (1) with and without slab, (2) with and without hoop bars in the joint region, (3) upward and downward direction of anchorage for the bottom bar in beams of exterior beam-column subassemblage. The test results have shown; (1) in case of interior beam-column subassemblage, there is no almost difference between nonseismic and seismic details in the strength and ductility capacity; (2) the Korean practice of anchorage (downward and 25 $d_{b}$ anchorage length) in the exterior joint caused the 10%∼20% reduction of strength and 27% reduction of ductility in comparison with the case of seismic details; and the existence of hoop bars in the joint region shows no effect in shear strain.

A Study on the Minimum Weight Design of Stiffened Cylindrical Shells (보강원통셸의 최소중량화설계 연구)

  • 원종진
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.4
    • /
    • pp.630-648
    • /
    • 1992
  • The minimum weight design for simply-supported isotropic or symmetrically laminated stiffened cylindrical shells subjected to various loads (axial compression or combined loads) is studied by a nonlinear mathematical search algorithm. The minimum weight design in accomplished with the CONMIN optimizer by Vanderplaats. Several types of buckling modes with maximum allowable stresses and strains are included as constraints in the minimum weight design process, such as general buckling, panel buckling with either stingers or rings smeared out, local skin buckling, local crippling of stiffener segments, and general, panel and local skin buckling including stiffener rolling. The approach allows the consideration of various shapes of stiffening members. Rectangular, I, or T type stringers and rectangular rings are used for stiffened cylindrical shells. Several design examples are analyzed and compared with those in the previous literatures. The unstiffened glass/epoxy, graphite/epoxy(T300/5208), and graphite/epoxy aluminum honeycomb cylindrical shells and stiffened graphite/epoxy cyindrical shells under axial compression are analyzed through the present approach.

Experimental Study on Nonlinear Behaviors of A 1:12 Scale 10-Story Reinforced Concrete Frame with Nonseismic Details (비내진 상세를 가진 1:12축소 10층 R.C.골조의 비선형 거동에 관한 실험 연구)

  • Lee, Han-Seon;Kang, Kyi-Yong
    • Magazine of the Korea Concrete Institute
    • /
    • v.11 no.1
    • /
    • pp.255-266
    • /
    • 1999
  • The objective of this experiment is to observe the elastic and inelastic behaviors of high-rise reinforced concrete frames having non-seismic details. To do this, a building frame designed according to Korean seismic code and detailed in the Korean conventional practice was selected. A 1:12 scale plane frame model was manufactured according to similitude law. A reversed lateral load test and a monotonic pushover test were performed under the displacement control. To simulate the earthquake effects, the lateral force distribution was maintained to be an inverse triangle by using a whiffle tree. From the tests, base shears, crack pattern, local rotations in the ends of critical members and the relations between interstory drift versus story shear are obtained. Based on test results, conclusions are drawn on the implications of the elastic and inelastic behaviors of a high-rise reinforced concrete frame having non-seismic details.

Numerical Study on Failure Mechanism of Tunnel Shotcrete Lining (터널 숏크리트 라이닝 파괴 메커니즘에 대한 수치해석적 고찰)

  • Shin, Hyusoung;Shin, Dongin;Bae, Gyujin;Kim, Donggyu
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.7
    • /
    • pp.167-177
    • /
    • 2009
  • This study investigates a failure mechanism of a tunnel shotcrete lining with respect to a concentrated load due to blocky rock mass. First of all, it is carried out to survey relevant researches to shotcrete failures by literature reviews and to numerically re-investigate the failure modes of shotcrete lining given by previous researches. Through this study, the failure modes are relocated with the conditions which induce each failure mode newly proposed by this study. In addition to this, the arching shape of tunnel lining, which has not been considered in the previous research despite of inherent geometrical characteristics in tunnels, is taken into consideration in numerical investigation on lining failure in this study. As a result, it is shown that more simplified failure modes can be found on the tunnel boundary condition and the corresponding failure condition to each mode can be different from ones of the previous study due to a tunnel arching effect.

  • PDF

Distribution of Wind Force Coefficients on the Single-span Arched House (아치형 단동하우스의 풍력계수 분포에 관한 연구)

  • 이석건;이현우
    • Journal of Bio-Environment Control
    • /
    • v.1 no.1
    • /
    • pp.28-36
    • /
    • 1992
  • The wind pressure distributions were analyzed to provide fundamental criteria for the structural design on e single-span arched house according to the wind directions through the wind tunnel experiment. In order to investigate the wind force distributions, the variation of the wind force coefficients, the mean wind force coefficients, the drag force coefficients and the lift force coefficients were estimated by using the experimental data. The results obtained are as follows: 1. When the wind direction was normal to the wall, the maximum positive wind pressure along the height of the wall occurred approximately at two-thirds of the wall height because of the effects of boundary layer flow. 2. When the wind direction was 30$^{\circ}$ to the wall, the maximum positive wind force occurred at the windward edge of the wall. When the wind direction was parallel to the wall, the maximum negative wind force occurred at the windward edge of the wall. 3. The maximum negative wind force along the width of the roof appeared around the width ratio, 0.4, and that along the length of the roof appeared around the length ratio, 0.5. 4. According to the results of the mean wind force coefficients analysis, the maximum negative wind force occurred on the roof at the wind direction of 30$^{\circ}$. 5. The wind forces at the wind direction of 30$^{\circ}$ instead of 0$^{\circ}$ are recommended in the structural design of supports for a house. 6. To prevent partial damage of a house structure by wind forces, the local wind forces should be considered to the structural design of a house.

  • PDF

Accelerated Life Prediction of Ethylene-Propylene Diene Monomer Rubber Subjected to Combined Degradation (복합노화를 받는 EPDM 고무의 가속수명예측)

  • Han, Seung Wook;Kwak, Seung Bum;Choi, Nak Sam
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.5
    • /
    • pp.505-511
    • /
    • 2014
  • The EPDM(ethylene-propylene diene monomer) rubbers used for manufacturing engine radiator hoses can be degraded by locally generated electrical stress in addition to thermal and mechanical stresses. This study presents an accelerated life prediction of the EPDM rubber under electrochemical stresses using the Arrhenius formula under various aging temperatures($60^{\circ}C$, $80^{\circ}C$, and $100^{\circ}C$). The modified life prediction formula considers the relationship between the gradient($E_a/R$) and the Arrhenius constant(C). The effects of tensile strain(5%, 10%) on the life of these rubbers were investigated. The aging temperature influences EPDM rubber life, and tensile strain was predicted. It was confirmed that the modified life prediction was within the data deviation level of the test.