• 제목/요약/키워드: 국부저항계수

검색결과 25건 처리시간 0.024초

도파관 배열에 의한 국부저항계수 산정 (Evaluation of Local Loss Coefficients for Different Waveguide-Below-Cutoff (WBC) Arrays of Electromagnetic Pulse (EMP) Shied in Buildings)

  • 방승기;채영태
    • 설비공학논문집
    • /
    • 제29권7호
    • /
    • pp.366-372
    • /
    • 2017
  • The objective of this study was to characterize Waveguide-Blow-Cutoff (WBC) array for Electromagnetic Pulse (EMP) shield in air duct or water pipe, the typical pathway of pulse in indoor space with critical electronic device. A numerical investigation with three different WBC designs (circular, rectangular, and hexagonal or honeycomb) was conducted to satisfy recommended shielding effectiveness (SE) levels from 80 dB to 140 dB. Pressure drop between upstream and downstream of EMP shields based on WBC arrays was also investigated to understand air flow feature in air duct of HVAC system. Results showed that honeycomb geometry outperformed other shapes in terms of reducing the depth of EMP shield, thus providing better air flow in duct path with lower local loss coefficient in HVAC system under SE requirements.

데크플레이트의 웨브국부좌굴에 관한 내력식 제안 (A Proposal for Strength Formula of Web Crippling in Trapezoidal Sheeting)

  • 신태송
    • 한국강구조학회 논문집
    • /
    • 제13권6호
    • /
    • pp.641-649
    • /
    • 2001
  • 본 논문에서는 데크플레이트의 웨브 국부좌굴에 관한 실용적인 내력식을 제안하고자 한다. 실험에서 유추된 해석모델을 이론적으로 규명한 기존의 연구를 바탕으로 내력에 영향을 미치는 주요 변수들을 조사 분석하여 관련 함수들을 유도한다. 각 변수들을 기존의 실험자료와 종합적으로 비교 분석하여 간편한 내력식을 제안한다. 유럽기준 EC 3 부록 Z 에 따른 통계평가로부터 저항 부분안전계수 ${\gamma}_M$ 을 구하며 목표로 하는 값 1.1과 비교되어진다.

  • PDF

선미선형을 변화시킨 두 척의 KRISO 300K VLCC 모형주위의 유동과 저항추진 특성에 대한 실험적 연구 (Experimental Study on Local Flow Characteristics and Propulsive Performance of Two KRISO 300K VLCCs with Different Stern Shapes)

  • 김우전;반석호;김도현;이춘주
    • 대한조선학회논문집
    • /
    • 제37권3호
    • /
    • pp.11-20
    • /
    • 2000
  • 저속 비대선에서는 추진기면에서의 반류형상이 저항 및 추진성능을 결정하는 중요한 요소가 된다. 그러므로 저속 비대선에서는 선미선형의 형상과 유동현상과의 관계를 파악하는 것이 좋은 선형을 설계하기 위해 필수적이다. 선형 변환을 통해 얻어진 선수부의 모양이 같고 선미부의 모양이 다른 두척의 대형 유조선 선형에 대해 저항 추진 시험과 국부유동 계측 실험을 수행하였다. 이는 우선 선형 변화에 따른 저항 추진 계수의 변화를 정량적으로 제시하고, 이러한 총량적인 계측값과 국부 유동관의 관계를 규명함으로써 선미 선형의 변화에 따른 빌지 보오텍스의 세기의 차이와 이로 인한 저항 및 추진효율의 변화 등을 설명하였다. 또한 계측된 실험 자료는 저속 비대선 주위의 유동에 대한 CFD 계산의 검증 자료로 활용할 수 있으리라 기대된다.

  • PDF

하중저항계수설계법 및 정밀해법에 의한 PFRP I형 단면 압축재의 국부좌굴강도 (Local Buckling Strength of PFRP I-Shape Compression Members Obtained by LRFD Design Method and Closed-Form Solution)

  • 최진우;서수홍;주형중;윤순종
    • 복합신소재구조학회 논문집
    • /
    • 제5권2호
    • /
    • pp.1-8
    • /
    • 2014
  • Fiber reinforced polymeric plastic (FRP) materials have many advantages over conventional structural materials, i.e., high specific strength and stiffness, high corrosion resistance, right weight, etc. Among the various manufacturing methods, pultrusion process is one of the best choices for the mass production of structural plastic members. Since the major reinforcing fibers are placed along the axial direction of the member, this material is usually considered as an orthotropic material. However, pultruded FRP (PFRP) structural members have low modulus of elasticity and are composed of orthotropic thin plate components the members are prone to buckle. Therefore, stability is an important issue in the design of the pultruded FRP structural members. Many researchers have conducted related studies to publish the design method of FRP structures and recently, referred to the previous researches, pre-standard for LRFD of pultruded FRP structures is presented. In this paper, the accuracy and suitability of design equation for the local buckling strength of pultruded FRP I-shape compression members presented by ASCE are estimated. In the estimation, we compared the results obtained by design equation, closed-form solution, and experiments conducted by previous researches.

압력용기강의 파괴저항곡선의 파괴변형률에 관한 연구 (A study on the Relations Between Fracture Strain and Fracture Resistance Curve of nuclear Pressure Vessel Steel)

  • 임만배
    • 한국해양공학회지
    • /
    • 제14권1호
    • /
    • pp.44-51
    • /
    • 2000
  • Safety and integrity are required for reactor pressure vessels because they are operated in high temperature. There are single specimen method multiple specimen method and load ratio analysis method which used as evaluation of safety and integrity for reactor pressure vessels. In this study the fracture resistance curve(J-R curve) elastic-plastic fracture toughness($J_{IC}$) and material tearing modulus ($T_{mat}$) of SA 508 class 3 alloy steel used as reactor pressure vessel steel are measured and evaluated at room temperature 20$0^{\circ}C$ and 30$0^{\circ}C$ according to unloading compliance method and load ration analysis method. And then the comparison with experimental $J_{IC}$ and theoretical$J_{IC}$ by local fracture strain is managed.

  • PDF

유전손실계수를 이용한 고전압설비의 절연특성 분석 (Analysis of Insulation Characteristics for Highvoltage Facilities using Dissipation facter)

  • 오봉근;이광호;최형철;변두균;임기조
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.2017-2018
    • /
    • 2008
  • 고전압설비의 열화상태를 분석하기위해 현장에서 실시하는 대표적인 절연진단시험으로 절연저항, 성극지수, 유전정접, 부분방전시험이 수행되고 있다. 이들 시험중에 부분방전시험은 국부적인 열화진단이 가능하여 현재 가장 신뢰성 있는 진단방법으로 이용되고 있지만, 변압기와 케이블의 경우 우수한 절연특성으로 부분방전 발생량이 미소하고, 현장의 주변노이즈로 인하여 효과적인 측정이 어렵다. 따라서, 본 논문에서는 현장진단에 적용 할 수 있고, 일반적인 절연물의 열화정도분석이 가능한 유전정접시험을 이용하여 실제 산업현장에서 측정한 고전압 변압기와 케이블의 유전손실계수의 경향성을 분석하였다.

  • PDF

홍수터 식생의 물리적 특성을 고려한 흐름저항계수 산정 및 흐름특성 변화 모의 (Evaluation of Flow Resistance Coefficient based on Physical Properties of Vegetation in Floodplains and Numerical Simulation of the Changes in Flow Characteristics)

  • 지운;장은경;안명희;배인혁
    • Ecology and Resilient Infrastructure
    • /
    • 제8권4호
    • /
    • pp.212-222
    • /
    • 2021
  • 본 연구에서는 홍수터 식생의 물리적 특성과 분포 특성을 고려하여 흐름저항계수를 산정하고 이를 2차원 수치모의에 반영하여 홍수터 식생분포가 흐름특성에 미치는 영향을 분석하였다. 홍수터 식생의 물리적 특성을 기존의 식생 흐름저항산정 공식에 적용하기 위해 지상라이다를 이용한 식생의 3차원 포인트 클라우드 분석을 수행하였으며, 홍수터 식생분포는 국부적으로 식생이 존재하는 경우와 홍수터 전체에 식생이 분포하는 경우로 구분하여 모의를 수행하였다. 대상구간의 모의결과, 홍수터 식생의 흐름저항계수는 매닝의 조도계수를 기준으로 계획홍수량이 발생할 경우 주하도 하상 조도계수에 비해 약 5배 이상의 값을 갖는 것으로 나타났으며, 이는 주하도와 홍수터의 수리특성 변화에도 영향을 미치는 것으로 나타났다.

제형 파형강판 복부판의 전단 설계 (Shear Design of Trapezoidally Corrugated Steel Webs)

  • 문지호;이종원;최병호;이학은
    • 대한토목학회논문집
    • /
    • 제28권4A호
    • /
    • pp.497-505
    • /
    • 2008
  • 파형강판은 아코디언 효과로 인하여 전단력에만 저항하는 특징이 있다. 파형강판에 작용하는 전단력으로 인하여 파형강판은 국부, 전체 및 연성 전단 좌굴에 의한 파괴가 발생할 수 있다. 여러 연구자들에 의하여 파형강판의 전단 거동에 관한 연구가 이루어졌으나, 파형강판의 전단 거동에 관한 명확한 규명이 이루어 지지 않아 보수적인 설계 방법이 적용되고 있는 실정이다. 본 연구에서는 파형강판의 전단 좌굴 강도에 대한 연구를 수행하였으며, 연구 결과를 검증하기 위하여 파형강판의 전단 좌굴 실험을 실시하였다. 먼저, 기존 연구자들이 제시하였던 국부, 전체 및 연성 좌굴 응력식을 실 교량 제원을 고려하여 간략하게 나타내었으며, 이 과정에서 전체 및 연성 전단 좌굴 계수와 파형강판의 전단 좌굴 계수를 제시하였다. 이러한 전단 좌굴 계수와 좌굴 곡선을 이용하여 파형강판의 전단 강도를 결정할 수 있다. 실험결과와 기존 연구자들의 결과를 본 연구의 전단 강도와 비교하였으며, 그 결과 제안된 강도는 제형 파형강판의 전단 강도를 합리적으로 평가하는 것으로 나타났다.

휨과 전단을 받는 고강도강 플레이트거더의 극한거동 (Ultimate Behavior of Plate Girders with High Strength Steel in Combined Bending and Shear)

  • 김종민;황민오;강영종
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2010년도 정기 학술발표대회
    • /
    • pp.84.1-84.1
    • /
    • 2010
  • 국내에서는 플레이트거더의 휨 강도 및 전단 강도를 허용응력설계법에 기반한 도로교설계기준(2005)에 근거하여 규정하고 있으며, 국외의 경우 하중저항계수설계법에 근간을 둔 AISC(2005) 등의 규정을 통해 산정하고 있다. 최근에는 인장강도 800MPa 급의 강재가 생산되고 있으나 국내 설계기준에서는 아직까지 상기 인장강도를 갖는 고강도강에 대한 설계기준은 마련되지 않고 있다. 본 연구에서는 휨과 전단이 동시에 작용하는 고강도강 적용 플레이트거더의 극한거동 해석을 통해 국내기준의 적용성을 판단하고, 국외기준인 AISC(2005)와 비교하여 나타내어 허용응력설계법에 근거한 국내기준의 강도산정법의 한계점에 대해 고찰하였다.

  • PDF

마샬 안정도시험기를 이용한 아스팔트 혼합물의 파괴에너지 측정시스템 개발 (Development of Fracture Energy Measurement System of Asphalt Mixture Using Marshall Tester)

  • 김부일;이문섭
    • 한국도로학회논문집
    • /
    • 제11권1호
    • /
    • pp.135-144
    • /
    • 2009
  • 본 연구는 마샬 시험기를 이용하여 아스팔트 혼합물의 균열저항성을 평가할 수 있는 보다 간편하고 합리적인 측정시스템을 개발하는데 목적이 있다. 균열저항성 평가를 위한 파라메타로서 파괴에너지를 이용하였다. 마샬 시험기는 기본적으로 공시체 외부에 거치한 LVDT를 이용하여 수직변형률을 측정하는 시스템이며, 이 같은 외부 수직변형률 측정방식은 하중 스트랩 부분에서 발생하는 국부적인 변형으로 인해 측정오차를 야기할 가능성이 있다. 따라서 추가적인 계측 시스템을 설치하지 않고 기본적인 마샬 시험기를 이용하여 혼합물의 파괴에너지를 측정하기 위해서는 공시체 외부에 거치한 LVDT를 이용한 수직변형률 측정값이 파괴에너지 산정에 적용가능한지 여부를 검증하여야 한다. 이를 위해 본 연구에서는 공시체 중앙부분에서의 수평변형률과 외부에 거치한 LVDT를 이용한 수직변형률을 측정하는 두 가지 방식의 간접인장강도실험을 수행하여 그 차이를 비교 분석하였다. 실험결과, 외부 수직변형률 측정의 문제점으로 지적되었던 하중 스트랩 부분에서 발생하는 국부적인 변형은 파괴시점 이전에는 극히 적은 것으로 나타나 파괴에너지 계산에 오차를 유발하지 않음을 보여주었다. 또한 외부 수직변형률 측정의 실험변동성을 확인한 결과, 변동계수가 15% 이하로 마샬시험기를 이용한 균열저항성 평가시스템에 이용 가능함을 알 수 있었다.

  • PDF