• Title/Summary/Keyword: 국부강도

Search Result 329, Processing Time 0.029 seconds

Seismic Behavior of Concrete-Filled HSS Bracing Members Reinforced by Rib (리브 보강된 콘크리트 충전 HSS 가새부재의 이력 거동)

  • Han, Sang Whan;Yeo, Seung Min;Kim, Wook Tae
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.1 s.74
    • /
    • pp.53-62
    • /
    • 2005
  • The purpose of this study is to improve the seismic behavior of the bracing members. Lee and Goel's (1987) concrete filling in the hollow structural section (HSS) reduced the severity of local buckling and increased the fracture life. However, concrete filling in the HSS did not prevent the occurrence of local buckling in the midsection of the bracing member, which resulted in continuous strength degradation. This study investigated the seismic behavior of the concrete-filled HSS bracing member, which is reinforced by ribs in the midsection of the bracing member. The main variable of the specimens is rib length. The test results showed that buckling mode, cyclic compression strength, and energy dissipation capacity of the bracing members were affected by rib length. Specimen reinforced with ribs with a length of 63% had better structural performance.

Finite Element Analyses on Ultimate Compressive Strength of Longitudinally Stiffened Polygonal Sections (종방향 보강재로 보강된 다각형 단면 기둥구조의 극한강도 해석)

  • Choi, Byung Ho;Park, Seong Mi;Hwang, Min Oh
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.40-40
    • /
    • 2011
  • 현재 일반적으로 활용되고 있는 원통형 쉘구조로 이루어진 타워구조의 대형화가 추진되면서 제작, 운반 편의성, 단면효율성, 경제성 제고를 위해 다각형단면 기둥구조물의 활용이 대두되고 있다. 하지만 다각형 단면 기둥구조의 극한강도에 대한 자료가 충분치 않고 관련 기준이나 지침이 명확히 제시되고 있지 않은 실정이다. 본 연구에서는 원통형 쉘구조물을 다각형구조물로 대체하여 제작될 경우 축방향 압축에 대한 내하력 향상 효과를 수치해석적으로 검토해 보고자 한다. 해석모델은 지름 2m, 두께 20mm인 원형강관 프로토타입 풍력타워 구조를 참고로 하여 이에 내접하도록 결정한 6~12각형 단면 형상으로써 높이 10,000mm인 3차원 기둥모델을 구현하였고 유한요소프로그램인 ABAQUS를 이용하여 해석하였다. 각 subpanel의 중앙에 종방향 보강재를 설치하였을 때 국부좌굴에 대한 내하력 변화를 비교하기 위해 종방향보강재로 보강한 모델을 구성하여 비교 해석을 수행하였다. 종방향 보강재의 제원은 미국 SSRC 제안식을 기준으로 삼았다. 탄성좌굴해석을 통해 탄성좌굴모드 형상을, 비선형비탄성해석을 통해 최종파괴모드 및 극한강도를 얻었다. 보강 전 후의 탄성좌굴 해석 결과로부터 최소모드의 고유치 값을 비교하였다. 각 subpanel 단면 중심부에 한 개의 보강재를 설치한 경우 탄성좌굴강도가 4배 가량 증가하였다. 이로부터, 보강재(n=1) 설치에 따라 유효 폭두께비가 1/2로 감소하는 효과를 확인 할 수 있다. 비선형해석결과로부터 subpanel의 단면중심에 보강재를 설치한 경우 보강재가 위치한 곳에 고정점이 형성되어 이를 중심으로 국부 좌굴모드에 변화가 생기는 것이 확인되었다. 이러한 변화는 다각형 단면 기둥구조의 내하력 성능, 즉 국부좌굴강도에 영향을 준다. 충분한 강성을 갖는 종방향 보강재가 설치된 경우, 극한상태에서도 유효폭두께비가 줄어드는 것과 같은 강도 향상 효과를 확인할 수 있다. 이러한 사실은 각 해석결과 극한강도를 DIN code, Migita와 Fukumoto의 제안식, SSRC 설계제안식 등과의 비교를 통해 확인할 수 있었다.

  • PDF

Review of Fatigue Strength Evaluation on Weld Joints of Hull Structure (선체구조 용접이음부의 피로강도 평가에 대한 검토)

  • 성요경
    • Journal of Welding and Joining
    • /
    • v.12 no.3
    • /
    • pp.26-35
    • /
    • 1994
  • 본 고에서는 VLCC(Very Large Crude Oil Carrier)의 운항중 선체의 구조적 불연속부에서 발생 하는 균열이 피로강도의 부족에 의해 발생하는 피로균열임을 밝히는 당사의 사례에 대해 설명 하고, 국부 구조해석기술을 이용하는 피로설계의 관점에서 선체구조가 충분한 피로강도를 갖고 안전한 구조가 될 수 있도록 선체 용접이음부의 피로강도를 평가하는 체계에 대해 검토하고자 한다.

  • PDF

A Simplified Approach to the Analysis of the Ultimate Compressive Strength of Welded Stiffened Plates (용접된 보강판의 압축 최종 강도의 간이 해석법)

  • C.D. Jang;Seung-Il Seo
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.30 no.2
    • /
    • pp.141-154
    • /
    • 1993
  • In this paper, a method to calculate the ultimate compressive strength of welded one-sided stiffened plates simply supported along all edges is proposed. At first initial imperfections such as distortions and residual stresses due to welding are predicted by using simplified methods. Then, the collapse modes of the stiffened plate are assumed and collapse loads for each mode are calculated. Among these loads, the lowest value is selected as the ultimate strength of the plate. Collapse modes are assumed as follows ; (1) Overall buckling of the stiffened plate$\rightarrow$Overall collapse due to stiffener bending (2) Local buckling of the plate part$\rightarrow$Local collapse of the plate part$\rightarrow$Overall collapse due to stiffener yielding (3) Local buckling of the plate part$\rightarrow$Overall collapse due to stiffener berthing (4) Local buckling of the plate part$\rightarrow$Local collapse of the plate part$\rightarrow$Overall collapse due to stiffener tripping. The elastic large deflection analysis based on the Rayleigh-Ritz method is carried out, and plastic analysis assuming hinge lines is also carried out. Collapse load is defined as the cross point of the two analysis curves. This method enables the utimate strength to be calculated with small computing time and a good accuracy. Using the present method, characteristics of the stiffener including torsional rigidity, bending and tripping can also be clarified.

  • PDF

A Study on the Characteristics of SM570TMC Plates in Compression Members (SM570TMC 강재의 압축재 특성에 관한 연구)

  • Im, Sung Woo;Kim, Yo Suk;Chang, In Hwa
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.3 s.76
    • /
    • pp.357-363
    • /
    • 2005
  • There is a great need for high-strength steel especially for the high-rise steel building structure. High-strength steels, however, may have mechanical properties that are significantly different from those of the conventional steels. The application of high-strength steels to building structures should be reviewed as to whether the inelastic behavior equivalent to that of conventional steels can be attained or not. In this study, SM570TMC steel was tested to evaluate buckling strength under axial compressive force. The comparison tests for local buckling strength evaluation of box-type and H-shaped welded columns were performed with variable width-thickness ratios. As for the experimental check, the maximum strength of stub column was determined by local buckling as far as the limit of width-to-thickness ratio was satisfied with current design codes. Also, the strength of the stub column did not decrease suddenly by local buckling before maximum strength even when the ratio is not satisfied. The buckling strength of SM570TMC steel was higher than both ASD (Allowable Stress Design) and LRFD (Load and Resistance Factor Design) specifications.

Evaluation on Bearing Capacity of End Girder Member with Local Corrosion (지점부 부재의 부식손상에 따른 강거더 단부 지압강도 평가)

  • Ahn, Jin Hee;Lee, Won Hong;Kim, In Tae;Jeong, Young Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.5
    • /
    • pp.74-82
    • /
    • 2017
  • Localized corrosions damages in their structural sections can be occurred affected by installed environment conditions with high temperature as near the coastline and humidity or their poor maintenance situation. In bearing supports of steel bridges, especially, lower web and vertical stiffener in end girder support can be easily corroded because of relatively higher humidity due to the narrow space in the end of girder and the wetted accumulated sediments affected by rain water or antifreezing admixture leaked from expansion joint. It can be related to change in their structural performance. In this study, thus, bearing strength test specimens were fabricated considering corrosion damage in the web and vertical stiffeners and the change in their bearing strengths were experimentally evaluated. From the test results, localized corrosion damage of structural members in the end girder affected the bearing strength of end girder support, especially, localized corrosion damage of the vertical stiffener relatively highly affected their bearing strengths.

Finite Element Post-buckling Analysis of Steel-Concrete Composite Column (철골-콘크리트 합성기둥의 후좌굴 거동에 관한 해석 연구)

  • Oh, Myoung Ho;Kim, Myeong Han;Kim, Sang Dae
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.6
    • /
    • pp.725-735
    • /
    • 2007
  • The local buckling strength and post-local buckling strength of thin steel plates in the steel-concrete composite column were evaluated by nonlinear finite element analyses. The proposed width-to-thickness limit ratio was based on elastic buckling analyses, in which the increased local buckling capacity of the plate due to the in-filled concrete was considered by the boundary conditions of the thin plate. Considering the initial imperfections and residual stresses, we determined the initial local buckling strength and post-local buckling strength of the thin plates with various width-to-thickness ratios. The formula to evaluate the compressive capacity of the steel-concrete composite column based on the effective width of the plate was proposed. For verification, values determined by the formula were compared with the experimental results.

Determination of the Allowable Load for Trussed Web Beam (트러스웹을 가진 보의 허용하중 산정)

  • Kim, Myeong-Han
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.2
    • /
    • pp.1-5
    • /
    • 2010
  • The efficient beam members for modern greenhouse need to be much lightweight with the required flexural and buckling strength. To confirm the applicability and practicality of the trussed web beam recently proposed for column and beam members of greenhouse, the flexural behavior and buckling characteristics were analyzed by the finite element approach. On the basis of analytical studies, the member design process was presented considering the lateral and local buckling behavior. Also, two improved alternatives which were capable of retaining the lateral and local buckling effectively were suggested.

Construction Safety Evaluation of Local Bearing Strength of Hollow Core Slab (중공 슬래브의 국부지압강도에 대한 시공안전성 평가)

  • Hur, Moo-Won;Yoon, Jeong-Hwan;Hwang, Kyu-Seok;Yoon, Sung-Ho;Park, Tae-Won
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.2
    • /
    • pp.8-15
    • /
    • 2018
  • Hollow Core Slab is a very efficient system that can reduce weight and its use has increased. Void slab is a concrete slab that has voids substituted with void material. Because of its saved volume of concrete, void slab can reduce weight of slabs. Also, it can't only save concrete but also can reduce carbon-emission. However, because of the unclear bearing strength at the part of void substituted with voiding material, several problems occur in constructing field. In this study, void slab including void material was built and local bearing strength test was carried out for 3 types of load(truck load, support load and Jack support load). As a result, bearing strength of void neck and upper void material is more than allowable load. And also, bearing strength of specimens with using deck and not using deck are also over allowable loads.

An Experimental Study of the Local Scouring at the Downstream of the Fixed Bed in Open Channel Flow (개수로 흐름 내 고정하상 하류부에서의 국부세굴에 관한 실험 연구)

  • Park, Sung Won;Ahn, Jungkyu;Hwang, Jin Hwan
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.388-392
    • /
    • 2015
  • 본 연구에서는 고정하상 직하류부에서 발생하는 국부세굴현상을 분석하기 위해서 이동상 수리실험을 수행하였다. 순환식 유량공급이 가능한 개수로 실험장치에 아크릴로 제작된 사각형 모형을 설치하고 하류에 균일한 입경의 모래를 설치하여 다양한 수리조건과 시간변화에 따른 하상고의 변화를 측정하였다. 그리고 측정된 하상고 자료로부터 시간별 최대세굴심의 크기를 산정하여 분석하였다. 그 결과 세굴심의 상류부 경사는 일정한 값으로 유지되었고, 최대세굴심과 세굴공 길이, 최대세굴심 발생거리는 시간변화에 따라 증가폭이 점차적으로 감소하였다. 또한 세굴심의 시간변화식의 기울기와 경계지점에서의 수심평균 상대난류강도값과의 관계를 분석하였다. 세굴공 내에서는 하상근처에서 후류가 발생하고, 수심방향으로 유속편차가 극심하게 증가하는 분리전단층이 발생하였다. 본 연구에서 분석된 최대세굴심의 시간적 변화양상과 세굴심 내부에서 발생하는 흐름 및 난류강도 분포특성을 보다 면밀히 분석하여 세굴심의 발달에 영향을 미치는 인자를 이용하여 향후 적절한 세굴심의 예측식을 개발할 수 있고, 최대세굴심을 저감할 수 있는 방안을 제안할 수 있다.

  • PDF