• Title/Summary/Keyword: 구치부 수복

Search Result 189, Processing Time 0.02 seconds

The effect of improperly contoured and poor fitting restorations to patient with oral lichen planus: periodontal and prosthetic treatment (구강 내 불량한 보철물 수복이 편평태선에 미치는 영향에 대한 치주, 보철적 접근)

  • Shin, Jin-Beom;Cho, Jin-Hyun;Lee, Cheong-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.4
    • /
    • pp.371-377
    • /
    • 2015
  • Oral lichen planus (OLP) is a common mucocutaneous disease, which presents as bilateral or multiple lesions. The several factors are implicated in etiology of OLP such as dental restorations, systemic disease, drugs and stress. Especially the influence of dental restorations and plaque control for OLP has been the interest in dentistry. This case is about OLP patient having poor contoured and ill-fitting metal ceramic restorations. The patient in this study has suffered from OLP for a long time, particularly after restoration of metal ceramic restorations on both posterior teeth of maxilla and mandible. This study reported that OLP lesion recovered effectively by improving the contour and fitness of restorations with plaque control.

Three-year follow-up of full mouth rehabilitation with anterior implant surveyed bridges and distal extension removable partial denture (전방 임플란트 써베이드 고정성 보철물과 후방연장 국소의치를 이용한 전악 보철 치료의 3년 경과 관찰 증례)

  • Gil, Ki-Sung;Yi, Hyo-Gyoung;Kim, Kyoung-A;Lee, Jung-Jin;Seo, Jae-Min
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.3
    • /
    • pp.218-226
    • /
    • 2018
  • In partial edentulous patients, implant-assisted removable partial denture which provide additional retention and support by placing a small number of implants in strategic positions might be suitable treatment. This case of patient with loss of maxillary posterior teeth and moderate to severe wear of residual dentition, three implants were placed in the maxillary anterior edentulous area and then surveyed bridges were made including remaining anterior natural teeth. Posterior edentulous area was restored with distal extension removable partial denture (RPD). In addition, the worn mandibular natural teeth were restored with fixed prostheses. As a result, reduced vertical dimension and collapsed occlusal plane were rehabilitated, and improved functionally and aesthetically. The purpose of this case was to report the results of three-year follow-up of full mouth rehabilitation with anterior implant surveyed bridges and distal extension RPD.

Rehabilitation using milled-bar with attachment maxilla overdenture in a patient with peri-implantitis fixed prosthesis: A case report (임플란트 주위염이 발생한 고정성보철 환자에 상악 Milled-bar와 부착장치를 이용한 피개의치로 수복한 증례)

  • Joon-Myung Lee;So-Yeun Kim;Du-Hyeong Lee;Kyu-Bok Lee;Cheong-Hee Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.2
    • /
    • pp.123-130
    • /
    • 2024
  • There are various methods for restoring the dentition of completely edentulous patients. Removable complete dentures have the advantage of being relatively economical, but they can be uncomfortable to wear. With the introduction of implant prosthodontics, various options such as implant-supported overdentures and hybrid prostheses have become available. If there is inadequate remaining ridge or limited financial resources, an overdenture supported by a few implants with additional attachments may be more suitable. In this case, due to severe peri-implantitis and other complications, the implants were removed. Subsequently, four implants (two on each side) were placed in the maxilla and a milled-bar with attachment was fabricated for each side of the maxilla.

Clinical remarks about esthetics in the case of full zirconia restoration utilizing Zirkonzahn Prettau® block (지르코잔 프레타우 블럭을 이용한 Full Zirconia 수복 시 심미에 관한 임상적 소견)

  • Park, Jong-Chan
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.22 no.1
    • /
    • pp.30-46
    • /
    • 2013
  • Porcelain fused to metal crown has been used mostly over the last 50 years for restorations in dentistry. However, the patients' awareness of aesthetic aspect, biocompatibility and the problems such as an allergy to metals led to the growing interest in the 'metal free restoration'. In particular, the price of the precious metals that have been mainly used to date has risen drastically, which made them impossible to play their role as oral restorative materials anymore, and in addition, the PFM restoration has intrinsic problems of chipping and fracture. Therefore, the CAD/CAM has been drawing more attention than ever due to the popular needs for the material that is more aesthetic and stronger for restoration of the molar implant. Considerations in carrying out the full zirconia restoration are as follows: 1) strength, 2) combination work, 3) light penetrability, 4) treatment of cracks, 5) the color reproducibility of the block, 6) the abrasivity of antagonistic tooth, 7) low temperature degradation. In this presentation, the color reproducibility of the block will be discussed. One of the biggest reasons for avoiding the full zirconia restoration is that it is difficult to reproduce the natural color compared to the conventional PFM restoration. Thus, many clinicians show reluctance due to the exposure of the ugly block when the coloring on the surface is removed after occlusal adjustment. From the experience of using blocks by Zirkonzahn for more than 4 years, it is considered that these problems can be addressed to some degrees. Accordingly, how to make restorations that are well in harmony with surrounding prosthesis or natural teeth will be discussed.

MAXILLARY SINUS ELEVATION PROCEDURES: A Report of Six Cases (상악동거상술 및 임플란트매식에 의한 상악 구치부 수복에 관한 임상적 연구)

  • Lee, Dong-Han
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.2
    • /
    • pp.300-316
    • /
    • 1995
  • Methods for restoring the posterior portion of the maxilla with delayed and simultaneous sinus lift, composite graft and placement of TPS cylinder and screw type implants are presented. Sinus grafting is needed because of minimal remaining alveolar bone and supporting posterior maxillary portion, The composite graft material uses a combination of autogeneous bone from tuberosity, dimeneralized freeze dried allogenic bone and hydroxylapatite with saline. Since 1991, feb, 1 sinus graft with delayed implantation of 3 cylinder implants and 5 sinus grafts with simultaneous placement of 4HA coated screw typed, 8 TPS cylinder typed implants have been performed for 6 patients. None of the 15 restored implants have been lost, Temporization of prosthesis was done about 2-5 months before final prosthetic work, None of them shows any severe complication.

  • PDF

Mandibular Posterior Rehabilitation Case after Occlusal Plane Correction using Micro-Implant Anchorage (Micro-Implant를 이용한 교정치료로 교합평면 개선 후 하악 구치부 수복증례)

  • Park, Ju-Mi
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.20 no.2
    • /
    • pp.143-150
    • /
    • 2004
  • Endosseous implants have been used to provide anchorage control in orthodontic treatment without the need for special patient cooperation. However these implants have limitation like space requirement, cost, equipments. Recently titanium micro-implant for orthodontic anchorage was introduced. Micro-implants are small enough to place in any area of the alveolar bone, easy to implant and remove, and inexpensive. In addition, orthodontic force application can begin almost immediately after implantation. The mandibular first, maxillary first, mandibula second, and maxillary second molars were the four most commonly missing teeth in adult sample. In case of posterior molar teeth missing, deflective contacts in any position, over time, has produced pathologic change of occlusal scheme because of extrusion of opposing teeth. This case had interocclusal space deficiency by mandibular right molars missing over time. The micro-implants had been used for intrusion of maxillary right molars for interocclusal space. The micro-implant would be absolute anchorage for orthodontic movement. Therefore, the micro-implant would be effective method for correction of occlusal plane.

Factors affecting fracture of full contour monolithic zirconia dental prosthesis in laboratory process (구치부 심미수복, 풀지르코니아 크라운의 파절원인과 그 해결방안)

  • Lee, Soo Young
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.23 no.2
    • /
    • pp.77-79
    • /
    • 2014
  • There are several factors affected fractures of full contour zirconia (FCZ) dental prosthesis in laboratory process. First, residual moisture can cause zirconia cracks. Complete dry is requisite before zirconia sintering to prevent zirconia cracks. Second, slow cooling rate is essential to prevent cracks during zirconia sintering process. Cracks in bridge pontic area, thick dental implant prosthesis can be prevented by slow cooling rate such as 3 degree Celsius per minute during zirconia sintering. Third, slow heating rate and slow cooling rate during staining and glazing procedure is necessary to inhibit thermal shock of sintered dental zirconia. Lower preheat temperature of porcelain furnace is recommended. Finally, using diamond disc to open embrasure can lead cracks.

AN EXPERIMENTAL STUDY OF MICROLEAKAGE AROUND POSTERIOR ESTHETIC RESTORATIVE MATERIALS (구치부 심미성 수복물의 변연누출에 관한 실험적 연구)

  • Shin, Dong-Hoon;Kwon, Hyuk-Choon
    • Restorative Dentistry and Endodontics
    • /
    • v.15 no.2
    • /
    • pp.122-126
    • /
    • 1990
  • To examine the microleakage of posterior esthetic restorative materials, using 2% methylene blue dye solution, dye penetration was determined with 80 permanent posterior teeth after thermocycling. The following results were obtained. 1. Amalgam group showed the most severe dye penetration of all test groups through the enamel and dentin / cementum margins. 2. Clearfil group showed much more dye penetration than P-50 at the enamel margin and than resin inlay system at the dentin / cementum margin. 3. Through the etched enamel margin, P-50 and resin inlay system groups showed no dye penetration, if any, but through the dentin / cementum margin, all test groups showed dye penetration. 4. Resin inlay system showed the least dye penetration of all test groups through the dentin / cementum margin.

  • PDF

Retrospective study on survival and complication rates of posterior single implant according to the implant diameters, lengths and position (구치부 단일 임플란트의 직경과 길이, 식립 위치에 따른 생존율 및 합병증의 발생률에 대한 후향적 연구)

  • Soo-Young Hong;Seon-Ki Lee;Jin-Han Lee;Jae-In Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.2
    • /
    • pp.101-112
    • /
    • 2023
  • Purpose. This retrospective study was to investigate the survival and complication rates of posterior single implant according to the implant diameters, lengths and position. Materials and methods. Patients who had been restored single implant prosthesis in the posterior area by the three prosthodontists in the department of prosthodontics, Daejeon dental hospital of Wonkwang university, in the period from February 2014 to May 2018 were selected for the study. A total of 505 patients with 697 implants were observed. The survival and complications of implants were investigated using electronic medical records and radiographs. Fixture diameters, lengths, position, patient's sex and age were assessed as possible factor affecting the survival and complications of implants. Results. 3-year cumulative survival rates of posterior single implants were 98.5% and 5-year cumulative survival rates were 94.4%. 5-year cumulative survival rates were higher in implants with diameter > 4.0 mm (97.0%) than implants with diameter ≤ 4.0 mm (89.5%), and in females (98.8%) than males (92.4%). There were statistically significant differences (P < .05). The mechanical complication rate was 20.1% and the biological complication rate was 4.7%. Complications occurred in order of abutment screw loosening (7.5%), decementation (6.3%), proximal contact loss (3.7%) and so on. Abutment screw loosening occurred more frequently in the lower molar region (10.5%), in males (9.5%) than females (5.1%), and in patients aged < 65 years (9.4%) than patients aged ≥ 65 years (5.1%). There were statistically significant differences (P < .05). Conclusion. The 5-year cumulative survival rates were higher in implants with diameter > 4.0 mm than implants with diameter ≤ 4.0 mm and in females than males. Abutment screw loosening which was the most commonly occurring complication occurred more frequently in the lower molar region, in males than females, and in patients aged < 65 years than patients aged ≥ 65 years. There were statistically significant differences.

Comparative Evaluation of the Survival Rates of Zirconia Crown and Stainless Steel Crown for Proximal Caries in Primary Molars: a Retrospective Study (유구치 인접면 우식증 수복 시 지르코니아 전장관과 기성금속관의 생존율 비교 평가: 후향적 연구)

  • Gahui Jeong;Nanyoung Lee;Hyewon Shin;Suhyun Park;Myeongkwan Jih
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.50 no.3
    • /
    • pp.307-317
    • /
    • 2023
  • Due to increasing demand for aesthetics, zirconia crowns have become a popular choice for treating primary molars. However, there is limited literature available comparing the survival rates of zirconia crowns with those of other restorative materials. The objective of this study was to compare the 36-month survival rates of zirconia crowns and stainless steel crowns for proximal caries, as well as to analyze failure types associated with each crown type. Electronic medical records and radiographs of 1,061 primary molars from 498 patients treated with 2 types of prefabricated crowns at Chosun University Dental Hospital and 2 private dental clinics between 2017 and 2019 were collected and analyzed. The survival rate of zirconia crowns was found to be lower compared to that of stainless steel crowns. Regarding the groups without pulp treatment, the survival rate of stainless steel crowns was significantly higher than that of zirconia crowns. However, in the groups that received pulp therapy, no significant difference in the survival rates was observed between the two preformed crowns. Notably, abnormal root resorption or periapical lesions were identified as the primary cause of restorative failure in stainless steel crowns, whereas loss of restoration was the predominant cause in zirconia crowns. This study holds valuable implications for clinicians when selecting preformed crowns for primary molars.