Experimental Study on the Composite Bridge Deck of Hollow Section (중공단면 복합소재 교량 바닥판의 시험을 통한 구조적 특성 분석)

  • Lee, Sung-Woo;Kim, Byung-Suk;Hong, Kee-Jeung
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.19 no.4 s.74
    • /
    • pp.325-335
    • /
    • 2006
  • In this paper, flexural test, girder-connection test and barrier-connection test for the pultruded composite bridge deck of hollow section, were carried out and its structural characteristics were evaluated. In the flexural test specimen, deflection was measured at center of the span and strains were measured at various locations to see the structural behavior up to the failure. In addition, finite element analysis was performed for the flexural test specimen and the results were compared with experiments, and load carrying capacity was evaluated. Also, field load test was conducted for the demonstration plate girder bridge and other field applications were described.

Verification of experimental test for PSC-Steel-PSC hybrid beam using nonlinear FEM analysis (비선형 FEM 해석을 이용한 PSC-Steel-PSC 혼합구조 보의 휨 실험 검증)

  • Kim, Sang-Hyo;Won, Jung-Hun;Park, Se-Jun;Lee, Chan-Gu
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2009.04a
    • /
    • pp.517-520
    • /
    • 2009
  • 본 연구에서는 비선형 FEM 해석을 이용하여 PSC(Prestressed concrete)와 강으로 구성된 혼합구조 보의 휨 실험을 검증하였다. 혼합구조 보의 거동에 가장 큰 영향을 미치는 연결부는 Perfobond rib로 구성된 경우와 스터드로 구성된 경우를 고려하였다. 이종 재료가 접하는 경계면의 상호 작용에 대해 완전합성과 부분합성인 경우를 고려하여 혼합구조 보의 비선형 해석을 수행한 후 해석 결과와 실험 결과를 비교하였다. 하중-처짐관계, 파괴 형상 등의 해석 결과를 실험 결과와 비교한 결과, 부분합성을 고려한 모형이 실험 결과와 유사한 거동을 보였으며 또한 Perfobond rib를 갖는 실험체가 스터드를 갖는 실험체보다 해석 결과와 비교 시 안전측의 결과를 나타냈다.

  • PDF

Global Sensitivity Analysis of Joints for Plug-in Digital Framework (플러그인 디지털 프레임웍을 위한 연결부 전역민감도 해석)

  • Lee, Dooho;Won, Young-Woo;Kwon, Jong-Hyun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.5
    • /
    • pp.483-488
    • /
    • 2016
  • Plug-In Digital Framework is a system response analysis tool that is employed when system components are composed of black-box modules. Generally, the dynamic characteristics of joints between the system components significantly affect system responses, and they lead to displacement- and frequency-dependent stiffness and loss factor. Thus, the sensitivity of each joint parameters should be estimated from a global perspective. In this study, we introduce a global sensitivity analysis procedure under the Plug-In Digital Framework. To efficiently calculate the system responses, we introduce the frequency response function (FRF)-based substructuring method. Using the random balance designs (RBD), we generate the system responses and estimate the global first-order sensitivities for each joint stiffness. We apply the proposed global sensitivity analysis method to an interior noise problem of a passenger car, and we evaluate the efficiency of the global sensitivity analysis method.

Development of Wide Connection Method for Vertical Joints of Precast Concrete Walls (프리캐스트 콘크리트 벽체 수직접합부의 광폭형 연결방식 개발)

  • Choi, Eun-Gyu;Shin, Yeong-Soo
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.5
    • /
    • pp.549-556
    • /
    • 2009
  • This research analyzed the structural efficiency and application by improving the 100 mm width vertical joint to 150 mm and developing three connection methods to reduce the difficulty in assembling and handling PC walls. Moreover, nonlinear finite analysis was used for analyzing. From the analysis results, when double width connection was applied, the PC wall showed larger load capacity and ductility due to the steel bar sharing loads efficiently. Moreover, as the dimension of loops and the number of bars increased, the maximum load capacity increased as well. Also, among the double width connections, the largest capacity showed in the order of welding, ring and C type loop. However, in case of welding type loop connection, the ring type loop is more stable due to changes in different site conditions. Therefore, thorough quality control of welding is necessary.

A Study on the Method of Local Stress Evaluation for the Wind Turbine Tower Flange (풍력발전시스템 타워의 플랜지 국부 응력 평가 기법 연구)

  • Won, Jong-Bum;Lee, Kang-Su;Park, Jong-Vin;Kim, Mann-Eung;Han, Sung-Kon;Lee, Sang-Lae
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2010.04a
    • /
    • pp.200-206
    • /
    • 2010
  • 본 논문은 풍력발전 시스템의 하부 지지 구조물인 타워의 플랜지 연결부 설계 평가를 위한 플랜지 모델건전성 평가 기법에 대해 다룬다. 일반적으로 풍력발전 시스템 타워의 연결부는 Ring-형 플랜지의 형태를 가지고 있다. 이러한 ring-형 플랜지에 대한 설계 기준 및 방법은 풍력 발전 시스템 기술기준 등 에 명시되어있다. 이러한 설계 기준을 따르는 플랜지 연결부에 대해 구조 및 체결 볼트의 건전성 평가를 위해 하중평가 전용 프로그램인 GH-Bladed 3.8를 통해 생성된 하중 데이터를 유한요소 범용 프로그램인 Ansys 12.0에 접목하여 구조해석을 수행 하였다. 해석 방법은 풍력발전시스템의 타워를 셸 요소로 모델링하여 계산한 해석 결과를 플랜지 모델의 경계면에 적용 시켜 해석하는 submodeling 기법과 타워를 빔의 형태로 단순화 화여 계산한 거동 결과를 플랜지 모델에 적용하는 기법을 사용 하였다. 이 두 가지의 해석 기법으로 도출된 결과의 비교를 통하여 해석 결과 신뢰성을 평가하고 효율적이고 합리적인 방법을 제시하고자 하였다.

  • PDF

노스리지 지진하의 강 뼈대 구조물에 대한 사례 연구

  • 김기동
    • Computational Structural Engineering
    • /
    • v.11 no.1
    • /
    • pp.46-57
    • /
    • 1998
  • 노스리지 지진하의 모멘트 저항 강 뼈대 구조물에 대한 사례연구결과를 요약하면 다음과 같다. 1) 탄성과 비탄성 동적해석 방법의 신뢰도가 구조물의 동적거동의 모형화에 크게 영향을 받는다는 것을 알 수 있었고 구조물의 동적거동의 모형화를 위한 보다 개선된 지침과 기준의 필요성이 부각되었다. 2) 비탄성 횡방향 정적해석은 6층높이의 건물까지는 비탄성동적해석과 유사한 결과를 보였으나 10층 이상의 건물에서는 고차 모드 효과를 고려하지 못하여 상당히 상이한 결과를 나타냈다. 3) 응답스펙트럼 해석은 노스리지 지진하에서 탄성 시간이력 해석에 비하여 100%까지 상이한 결과를 보였다. 특정지진에 대한 구조물거동의 상세조사시 응답 스펙트럼 해석 대신 시간이력해석을 수행하는 것이 바람직하다. 4) 탄성 부재력의 저항능력 비와 소성 회전각 등의 거동지수 등은 현존하는 건물의 연결부 손상을 검사하기 위한 지침을 마련하는데 도움을 줄 수 있지만 특정 연결부를 검사에서 배제시키는 유일한 근거로 사용되어서는 안될 것으로 판단된다.

  • PDF

Analysis of Internal Pressure Capacity of Modular Containment Structure for Small Modular Reactor (소형 원자로용 모듈화 격납구조의 내압성능 분석)

  • Park, Woo-Ryong;Yhim, Sung-Soon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.8
    • /
    • pp.362-370
    • /
    • 2019
  • The internal pressure capacity of a modular containment structure requires analysis to prevent the release of radioactive material in the case of an accident. To analyze the capacity, FEM models were prepared while considering the tendon arrangements and the contact surfaces between precast concrete modules, and then static analyses were carried out. The changing characteristics in the displacement and stress under step-wise loading were analyzed, along with the effects of selected parameters. For comparison, the capacity of a monolithic containment structure was also analyzed. Parametric analyses were done to suggest ranges of parameters such as the tendon force, tendon spacing, tendon location in concrete thickness direction, friction coefficient, and concrete thickness. The tendon force and frictional force provide a combined effect between contact surfaces of modules. The same level of internal pressure capacity can be secured even in the modular containment structure as in the monolithic containment structure by increasing the tendon force with additional tendons.

A Study on the Fatigue Crack at Welded Joint for Steel Plate Girder Railway Bridge (강철도 플레이트거더교 용접이음부 피로균열의 평가에 관한 연구)

  • Park, Jin-Eun;Kyung, Kab-Soo;Lee, Sung-Jin;Jo, Yun-Jae
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2010.04a
    • /
    • pp.306-309
    • /
    • 2010
  • 강철도 플레이트거더교의 경우 일반적으로 레일의 폭보다 거더 사이의 폭이 넓기 때문에 거더에 편심이 작용하게 된다. 이러한 편심 영향으로 거더 내측 상부플랜지에 휨변형이 일어나게 되어, 상부플랜지와 수직보강재 용접이음부에 반복하중에 의한 피로균열이 발생되고 있는 것으로 보고되고 있다. 본 연구에서는 공용중인 강철도 플레이트거더교를 대상교량으로 하여 공용하중에 대한 구조해석을 실시하였다. 대상교량에 대한 현장계측을 기초로 구조모델링을 검증하였고, 검증된 구조모델링을 사용하여 열차하중 하에서의 상부플랜지와 수직보강재 용접연결부에서의 피로균열 보강방안에 대한 구조해석을 실시하였다. 또한 상부플랜지와 수직보강재 용접이음부 상세해석을 통하여 피로균열 발생위치를 확인하고 연결이음부의 적절한 보강방안을 제시하고자 한다.

  • PDF

A Load Balancing Method Using Ring Network Structure in the Grid Database (그리드 데이터베이스에서 링 기반 연결 구조를 이용한 부하 분산 기법)

  • Jang Yong-Il;Shin Soong-Sun;Park Soon-Young;Bae Hae-Young
    • Journal of Korea Multimedia Society
    • /
    • v.9 no.9
    • /
    • pp.1107-1117
    • /
    • 2006
  • In this paper, a load balancing method using ring network structure in the Grid database is proposed. In the Grid database, generally, data is replicated for performance and availability. And, user's request is transferred to node and processed in that node which has target data. But, in such environment, a decline of performance can be occurred because unbalanced workload. A traditional research is proposed to solve unbalanced load problem. However, the Grid database has a number of systems and user's request always changes dynamically. Therefore, a traditional research can not be applied. The proposed method connects each node which has a same replicated data through ing network structure. If workload is overflowed in some node, user's request is transferred to a linked node which has a target data. And, this node stops another request processing until workload is decreased. Then, it changes the link structure through sending a message to a previous node, to stop request forwarding from a previous node. This paper shows a proposed method increases performance than existing research through performance evaluation and is more suitable for a complex and dynamic environment.

  • PDF

Seismic Performance of Column-Footing Connection of Modular Pier using CFT (CFT를 이용한 모듈러 교각 기둥-기초 연결부의 내진성능)

  • Kim, Ji Young;Kim, Ki Doo;Ma, Hyang Wook;Chung, Chul-Hun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.1
    • /
    • pp.73-85
    • /
    • 2014
  • The CFT (Concrete Filled steel Tubes) column-footing connection is cast-in-place embedded type which provides simple construction procedure, low cost, and superior structural performance. In this study, CFT column-footing connection of modular pier is proposed and structural performance is evaluated by experimental tests. To evaluate structural performance of the CFT column-footing connection, a series of experimental tests were performed for the 4 specimens with different embedded depth. As a result of the quasi-static test, the specimen with 0.6D (0.6 times the outside diameter of steel tube) embedded depth showed relatively low ductility than other specimens with larger embedded depth due to cone failure of base concrete occurred during the lower loading step. On the contrary, cone failure of the base concrete was not observed in the specimens with larger embedded depth than 0.9D, but typical flexural failure in lower part of CFT column was observed. With the analyses of force-displacement curve, displacement ductility, and energy dissipation capacity, it is concluded that the rational range of embedded depth of the CFT column-footing connection is from 0.9D to 1.2D in view of good seismic performance.