• Title/Summary/Keyword: 구조 연결부

Search Result 846, Processing Time 0.035 seconds

Structure Analysis and Scale Model Test for Strength Performance Evaluation of Submersible Mooring Pulley Installed on Floating Offshore Wind Turbine (부유식 해상풍력발전기용 반잠수식 계류 풀리의 강도 성능평가를 위한 구조해석과 축소 모형시험)

  • Chang-Yong Song
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.5
    • /
    • pp.479-487
    • /
    • 2023
  • Recently, the destructive power of typhoons is continuously increasing owing to global warming. In a situation where the installation of floating wind turbines is increasing worldwide, concerns about the huge loss and collapse of floating offshore wind turbines owing to strong typhoons are deepening. A new type of disconnectable mooring system must be developed for the safe operation of floating offshore wind turbines. A new submersible mooring pulley considered in this study is devised to more easily attach or detach the floating of shore wind turbine with mooring lines compared with other disconnectable mooring apparatuses. To investigate the structural safety of the initial design of submersible mooring pulley that can be applied to an 8MW-class floating type offshore wind turbine, scale-down structural models were developed using a 3-D printer and structural tests were performed on the models. For the structural tests of the scale-down models, tensile specimens of acrylonitrile butadiene styrene material that was used in the 3-D printing were prepared, and the material properties were evaluated by conducting the tensile tests. The finite element analysis (FEA) of submersible mooring pulley was performed by applying the material properties obtained from the tensile tests and the same load and boundary conditions as in the scale-down model structural tests. Through the FEA, the structural weak parts on the submersible mooring pulley were reviewed. The structural model tests were conducted considering the main load conditions of submersible mooring pulley, and the FEA and test results were compared for the locations that exceeded the maximum tensile stress of the material. The results of the FEA and structural model tests indicated that the connection structure of the body and the wheel was weak in operating conditions and that of the body and the chain stopper was weak in mooring conditions. The results of this study enabled to experimentally verify the structural safety of the initial design of submersible mooring pulley. The study results can be usefully used to improve the structural strength of submersible mooring pulley in a detailed design stage.

A Study on the Vibration Reduction Method for Main steam Piping in Nuclear Power Plant (원자력발전소 주증기관의 진동감쇠 연구)

  • Kim, Yeon-Whan;Kim, Jong-Yeob;Lee, Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1996.04a
    • /
    • pp.215-220
    • /
    • 1996
  • 원자력발전소의 주증기관은 증기발생기와 터빈을 연결하는 주요 계통으로서 여기서 발생하는 배관진동은 주요기기의 연결부, 밸브, 배관지지물과 건물 등에 복합적인 반복하중을 가하여 관련 지지물 및 구조물에 열화현상을 발생시켜 발전소의 안전운전에 심각한 영향을 초래할 가능성을 항상 내포하고 있다. 그럼에도 불구하고 배관진동 대책은 대부분 지지물을 추가로 설치하여 진동준위만 낮추고 있는 실정이다. 따라서 구체적인 배관진동의 예측, 측정 및 평가, 감쇠방안에 이르는 종합적이고 체계적인 연구가 요구되고 있다. 본 연구에서는 지지물의 열화현상 및 부분적인 파손으로 진동준위가 높아진 것으로 추정되는 원자력발전소 주증기관의 진동특성 및 요인을 분석하여 진동감쇠 방안을 도출하고 검증함으로써 배관 및 주변 구조물의 건전성을 확보하고 설비의 신뢰성을 확보하고자 하였다. 이를 위하여 주증기관을 모델링하여 해석하였으며, 발전소의 기동 및 정상운전시의 진동준위를 측정하였다. 또한 발전소의 정진기간중 일부 배관계에 대한 실험적 모우드 해석을 수행하였다. 여러가지 진동감쇠 방안을 검토하여 탄성지지 및 에너지 흡수효과를 동시에 발휘할 수 있는 특수 지지물(WEAR$_{TM}$)을 설치하는 방안을 도출하였으며, 현장에 설치한 후 배관의 진동상태를 확인함으로서 효과적인 방안임을 검증하였다.

  • PDF

Behavior of Reinforced Concrete Slabs Connected with Hinge Joints of Remodelling Buildings (리모델링 건물의 활절점에 의하여 연결된 철근콘크리트 바닥판의 거동 평가)

  • Sim Kyu-Kwan;Kim Sang-Sik;Lee Jung-Yoon;Choi kwang-Ho;Im Juhyeuk
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.5 s.89
    • /
    • pp.761-768
    • /
    • 2005
  • Lately outmoded and functionally obsolete buildings constructed in 1960s and 1970s are often remodelled and restored. Even though there are not serious structural defects in the existing buildings, many old buildings have been reconstructed to improve residence quality or to extend residence area of the buildings. The experimental or theoretical research on plane expansion of RC apartments is quite scare. In this research, 12 specimens and 19 RC slabs connected by hinged joints were tested. The new slab was connected to the existing slab by hinge joints injecting dowel bars between two slabs. Main parameters of the slabs are types of the dowel bars (D13 and D19), spacing of the dowel bars (150mm, 300mm, and 450mm), and the locations of the steel bars in the existing slabs. The test results indicated that the shear strength of the RC test slabs having various types of dowel bars was about twice that calculated by the ACI 318-02 code. All slabs failed in concrete spatting and the dowel steel bars did not reach their yield strengths.

A case Study on Vibration Characteristic Variation Due to Connective Degree of Freedom of Structure in FRE Synthesis Method (전달함수함성법에서 연결자유도 변화에 따른 구조물 진동특성 변화에 대한 연구)

  • Kim, Kuk-Su;Choi, Su-Hyun;Jo, Sung-Je;Jin, Bang-Man
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.684-691
    • /
    • 2005
  • 본 연구는 전달함수 합성법을 이용하여 보강후 구조물의 진동특성을 예측하는 방법이다. 이 방법은 보강후 구조물의 진동특성을 보강전 구조물의 전달함수를 이용하여 예측하는 기술로, 이에 관한 이론은 많이 알려져 있다. 하지만 실제 실험으로 전달함수를 계측할 경우 회전자유도에 대한 전달함수를 계측하기가 어렵다. 따라서 병진자 유도만으로 전달함수 합성법을 적용할 경우 발생하는 고유진동수 추정 오차를, 전체 자유도를 이용한 경우와 간단한 구조물의 수치해석을 통해서 비교해 보고자 한다.

  • PDF

An Experimental Study on the Automatic Interlinking of Meaning for the LOD Construction of Record Information (기록정보 LOD 구축을 위한 의미 상호연결 자동화 실험 연구)

  • Ha, Seung-rok;An, Dae-Jin;Yim, Jin-hee
    • Journal of Korean Society of Archives and Records Management
    • /
    • v.17 no.4
    • /
    • pp.177-200
    • /
    • 2017
  • In a new technological environment such as big data and AI, LOD will link record information resources with various data from both inside and outside. At the heart of this connection is the interlinking technology, and interlinked LOD will realize the opening of record information as the highest level of open data. Given the ever-increasing amount of records, automation through interlinking algorithms is essential in building LODs. Therefore, this paper analyzed the structure of record information interlinking with the external data and characteristics of the record information to be considered when interconnecting. After collecting samples from the CAMS data of the National Archives, we constructed a record information's LOD. After that, we conducted a test bed that automatically interlinks the personal information of the record metadata with DBPedia. This confirms the automatic interlinking process and the performance and accuracy of the automation technology. Through the implications of the testbed, we have identified the considerations of the record information resources of the LOD interlinking process.

Inelastic Time History Analysis of a Five-Story Steel Framed Structure Considering Rigidity of TSD Connection (TSD 접합부의 강성을 고려한 5층 철골골조구조물의 비탄성 시간이력해석)

  • Kang, Suk-Bong;Lee, Jae-Hwan
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.3
    • /
    • pp.281-291
    • /
    • 2010
  • In this study, a five-story steel frame was designed in accordance with KBC2005 to evaluate the effects of the beam-column connection on the structural behavior. The connections were designed as fully rigid and semi-rigid. The fiber model was used to describe the moment-curvature relationship of the steel beam and the column, the power model for the moment-rotation angle of the semi-rigid connection and the three-parameter model for the hysteretic behavior of the steel beam, column, and connection. The structure was idealized as separate 2-D frames and as connected 2-D frames. The peak ground accelerations of four earthquake records were modified in a time-history analysis for the levels of the mean return period and for the maximum base-shear force in a pushover analysis. The top story displacement, base-shear force, story drift, demanded ductility ratio for the semi-rigid connection, maximum bending moment of the column, beam, and connection, and distribution of the plastic hinge were examined in the time-history analysis. The frame with the semi-rigid connection yielded a lower base-shear force, less magnitude, and increasing ratio in the bending moment of the column, beam, and connection than the frame with a fully rigid connection. The TSD connection was deemed to have secured the economy and safety of the sample structure that was subjected to seismic excitation for the Korean design level.

Design of Inverted-F Antenna Using a Coupling Feed (커플링 급전 구조를 사용한 역 F형 안테나의 설계)

  • Kim, Sang-Won;Choi, Hak-Keun;Park, Jae-Hyun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.7
    • /
    • pp.726-733
    • /
    • 2010
  • This paper propose the printed inverted-F antenna using the coupling feed for the mobile phone. The coupling feed can normally leads the additional capacitances in the antenna, so the high inductive reactance of the antenna can be partly compensated. In this paper, it is shown that the bandwidth of the proposed antenna using the coupling feed is improved at $824{\sim}960$ MHz and $1,710{\sim}2,390$ MHz. Then it is compared with the simple direct feed to confirm the improvement of the bandwidth. The proposed antenna covers GSM850/GSM950/DCS/USPCS/WCDMA/Wibro and has the maximum gain of -$4.794{\sim}1.648$ dBi and shows omnidirectional patterns over the operating bands.

Dynamic response of segment lining due to train-induced vibration (세그먼트 라이닝의 열차 진동하중에 대한 동적 응답특성)

  • Gyeong-Ju Yi;Ki-Il Song
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.25 no.4
    • /
    • pp.305-330
    • /
    • 2023
  • Unlike NATM tunnels, Shield TBM tunnels have split linings. Therefore, the stress distribution of the lining is different even if the lining is under the same load. Representative methods for analyzing the stress generated in lining in Shield TBM tunnels include Non-joint Mode that does not consider connections and a 2-ring beam-spring model that considers ring-to-ring joints and segment connections. This study is an analysis method by Break-joint Mode. However, we do not consider the structural role of segment lining connections. The effectiveness of the modeling is verified by analyzing behavioral characteristics against vibration loads by modeling with segment connection interfaces to which vertical stiffness and shear stiffness, which are friction components, are applied. Unlike the Non-joint mode, where the greatest stress occurs on the crown for static loads such as earth pressure, the stress distribution caused by contact between segment lining and friction stiffness produced the smallest stress in the crown key segment where segment connections were concentrated. The stress distribution was clearly distinguished based on segment connections. The results of static analysis by earth pressure, etc., produced up to seven times the stress generated in Non-joint mode compared to the stress generated by Break-joint Mode. This result is consistent with the stress distribution pattern of the 2-ring beam-spring model. However, as for the stress value for the train vibration load, the stress of Break-joint Mode was greater than that of Non-joint mode. This is a different result from the static mechanics concept that a segment ring consisting of a combination of short members is integrated in the circumferential direction, resulting in a smaller stress than Non-joint mode with a relatively longer member length.

Design of a Neuro-Fuzzy System Using Union-Based Rule Antecedent (합 기반의 전건부를 가지는 뉴로-퍼지 시스템 설계)

  • Chang-Wook Han;Don-Kyu Lee
    • The Transactions of the Korea Information Processing Society
    • /
    • v.13 no.2
    • /
    • pp.13-17
    • /
    • 2024
  • In this paper, union-based rule antecedent neuro-fuzzy controller, which can guarantee a parsimonious knowledge base with reduced number of rules, is proposed. The proposed neuro-fuzzy controller allows union operation of input fuzzy sets in the antecedents to cover bigger input domain compared with the complete structure rule which consists of AND combination of all input variables in its premise. To construct the proposed neuro-fuzzy controller, we consider the multiple-term unified logic processor (MULP) which consists of OR and AND fuzzy neurons. The fuzzy neurons exhibit learning abilities as they come with a collection of adjustable connection weights. In the development stage, the genetic algorithm (GA) constructs a Boolean skeleton of the proposed neuro-fuzzy controller, while the stochastic reinforcement learning refines the binary connections of the GA-optimized controller for further improvement of the performance index. An inverted pendulum system is considered to verify the effectiveness of the proposed method by simulation and experiment.

Failure behavior analysis of a penetration type pile head stiffener (관통형 말뚝두부 보강의 파괴거동해석)

  • Park, Jun-Hwa;Moon, Keun-Ho;Lee, Gye-Hee
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2009.04a
    • /
    • pp.446-449
    • /
    • 2009
  • 본 연구에서는 강관말뚝과 기초와의 연결시 보강에 사용되는 관통형 말뚝두부보강에 대한 파괴거동을 파악하기 위한 구조해석을 수행하였다. 구조물의 관공부에 대한 해석에서 철근의 인장파괴시 발생하는 관통부의 응력을 검토하고 철근의 파괴형상과 실험에서 얻어진 철근의 파괴형상을 비교하였다. 대상구조물의 전체적인 파괴거동은 인장, 압축, 전단, 휨모멘트에 대하여 파괴가 발생할 때까지 변위를 증가시키고 이때 발생하는 반력과 구조물의 파괴거동을 파악하였다. 이 때 강재의 비선형 거동 및 충진콘크리트의 비선형및 균열거동이 고려되었다. 해석의 결과로 대상구조물의 파괴거동 및 극한하중 저항능력이 평가되었다.

  • PDF