• Title/Summary/Keyword: 구조 연결부

Search Result 846, Processing Time 0.031 seconds

A Heuristic Load Balancing Algorithm by using Iterative Load Transfer (반복적인 부하 이동에 의한 휴리스틱 부하 평형 알고리즘)

  • Song Eui-Seok;Oh Ha-Ryung;Seong Yeong-Rak
    • The KIPS Transactions:PartA
    • /
    • v.11A no.7 s.91
    • /
    • pp.499-510
    • /
    • 2004
  • This paper proposes a heuristic load balancing algorithm for multiprocessor systems. The algorithm minimizes the number of idle links to distribute load traffic and reduces its communication cost. Each processor iteratively tries to transfer unit load to/from every neighbor processors. However, real load transfer is collectively done after complete load traffic calculation to minimize useless traffic. The proposed algorithm can be employed in various interconnection topologies with slight modifications. In this paper, it is applied to both hypercube and mesh environments. For performance evaluation, simulation studies are performed. The performance of proposed algorithm is compared to those of two well-known algorithms. The results show that the proposed algorithm always balances the loads perfectly. Furthermore, it reduces the communication costs by $70{\%}{\~}90{\%}$ in the hypercube ; and it reduces the cost by $\75{\%}$ in the mesh, compared to existing algorithms.

Nonlinear Analysis of Cyclically Loaded Concrete-Steel Structures Using an Anchor Bond-Slip Model (앵커 부착-미끄러짐 모형을 이용한 콘크리트-강재 구조물의 비선형 반복하중 해석)

  • Lim, Ju Eun;Lee, Jee Ho
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.5A
    • /
    • pp.495-501
    • /
    • 2009
  • In this paper, a numerical anchor bond-slip model is proposed to improve the numerical simulation of concrete-steel structures connected with steel anchor bolts and subjected to extreme cyclic loading. The suggested bond-slip model is composed of a group of nonlinear uniaxial connector elements and its parameters can be determined by calibrating the model with pull-out test data. Numerical analysis results from simulating a concrete foundation-steel column structure using the proposed bond-slip anchor model, which is implemented based on Abaqus elements, and the perfect-bond anchor model are compared with the experimental results. It is concluded that a reasonable anchor bond-slip model is required to realistically simulate concrete-steel structures subjected to extreme cyclic loading, and the proposed anchor bond-slip model shows acceptable performance in the present numerical analysis.

Natural Period Estimation for the Buildings of Upper Wall and Lower Frame Type (상부벽식-하부골조를 가진 복합구조물의 고요주기예측)

  • 박기수;김희철;김종헌
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.4 no.4
    • /
    • pp.1-13
    • /
    • 2000
  • 상부벽식 하부골조를 가진 복합구조물은 부족한 대지를 효율적으로 활용하기 위하여 건설되고 있다. 이러한 복합건물은 상부벽식-하부골조를 가지는 구조로써 일반적으로 전이보 또는 전이판으로 상하부를 연결하고 있다. 따라서 상하부 구조사이의 강성과 질량에 많은 차이가 발생하게 된다. 구보물의 고유주기는 지진하중과 밑면전단력을 결정하기 위한 중요한 변수이다. 그러나 현재 국내 규준에서 제안하는 고유주기 산정식은 이러한 건물에는 적용할 수 없다. 본 연구에서는 상부벽식-하부골조를 가진 복합구조물의 고유주기의 산정에 영향을 미치는 변수들 중 가장 큰 영향을 미치는 건물의 상하부 층수에 따른 변수만을 고려하여 고유주기산정식을 제안하였다. 하부는 2~5개 층을 가지고, 상부는 10~18개 층을 가지는 15~20층의 건물이면 정형적인 평면을 가지는 복합구조물로 한정하였다. 건물 내부의 채움벽에 대한 효과를 고려한 고유주기 제안식은 다음과 같다. 장변 방향 : $T_{L}$=($0.20H_{h}+0.05H_{i}$)/$sqrt{B}$-0.42 단변 방향 :$T_{S}$=($0.07H_{h}+0.12H_{i}$)/$sqrt{B}$-0.40

  • PDF

Engineering Properties of Sewage Polymer Concrete Culvert (폴리머 콘크리트를 적용한 하수암거의 공학적 특성)

  • Kwon, Seung Jun;Min, Byung Yoon;Park, Sang Soon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.6
    • /
    • pp.9-17
    • /
    • 2012
  • Concrete sewage culvert shows degradation with time since it is always exposed to various harmful ions, and deterioration of concrete culvert propagates to structural safety problems. After reclamation, maintenance for concrete sewage culvert is very difficult so that high durable and structural performance are essential for the sewage concrete culvert. Recently polymer concrete has been used to improve mechanical properties and durability performance. In this paper, engineering properties are evaluated for sewage culvert made with polymer concrete, and leakage and adhesive strength between joints are evaluated with small-scale models. The polymer sewage culvert shows high compressive strength over 100MPa with low water permeability and chloride penetration. Furthermore, high resistances to chemical and biological attack are evaluated. Through tests for leakage and adhesive, unification of joints is verified with evaluation of no leakage and high adhesive strength. Precast polymer sewage culvert in this paper can be actively used for severe conditions like sewage lines.

A Study for Improved Design Criteria of Composite Pile Joint Location based on Case Analysis (사례 분석을 통한 복합말뚝 이음위치의 설계 기준식 개선 연구)

  • Hwang, Uiseong
    • Journal of the Korean GEO-environmental Society
    • /
    • v.20 no.3
    • /
    • pp.21-30
    • /
    • 2019
  • Composite pile, which is composed of the steel pipe pile in which the large horizontal force acts and the PHC pile in which the small horizontal force acts by a special connecting devices, is being commercialized as a base material for civil engineering structures. The core of such a composite pile can be said to be a design criterion for estimating the joint position and stability of the connection device between steel pipe pile and PHC pile. In Korea, there is no precise specification for the location of composite pile joints. In the LH Design Department (Korea Land & Housing Corporation, 2009), "Application of composite pile design and review of design book marking" was made with reference to Road Design Practice Volume 3 (Korea Expressway Corporation, 2001). this is used as a basis of the design of the composite pile. It can not be regarded as a section change of the composite pile, so it has a limitation in application. Therefore, In this study, we propose a design criterion for the location of the section of the composite pile (joint of steel pipe pile and PHC pile) and evaluate the stability and economical efficiency of it by using experimental method and analytical method. Analysis of composite pile design data installed in 79 domestic bridges abutment showed that the stresses, bending moments, and displacements acting on the pile body and connection of the pile were analyzed. Through the redesign process, it was confirmed that the stresses generated in the connecting device occur within the allowable stress values of the connecting device and the PHC pile. In conclusion, the design proposal of composite pile joint location through empirical case study in this study is an improved design method considering both stability and economical efficiency in designing composite pile.

A Study on the Tear Behavior of Woven Fabric with Wire Mesh (매쉬 직물을 이용한 직물의 인열 거동 연구)

  • ;Seung-Yun Lee
    • Proceedings of the Korean Fiber Society Conference
    • /
    • 2003.04a
    • /
    • pp.130-131
    • /
    • 2003
  • 산업용 직물은 다른 건축재료에 비해 유연성이 크고 재료무게에 비해 카버하는 면적이 넓어서 장기적인 고정 건축물이 아닌 경우에 그 이용도가 늘어나고 있다. 이러한 산업용 직물의 주 기능은 예정 사용기간 동안 직물 양면사이의 압력을 견디는 일이 주 부하 모드이며 이 이차원구조를 유지하는 부분은 이 구조를 잡고 있는 부분이다. 그러나 직물의 일부가 파손되어 압력차를 유지하지 못하면 공압을 이용한 건축물의 순간적인 파괴로 연결된다. (중략)

  • PDF

머리 계측 부위에 대한 연구

  • 안영실;서미아
    • Proceedings of the Costume Culture Conference
    • /
    • 2004.04a
    • /
    • pp.75-77
    • /
    • 2004
  • 머리형태의 근간이 되는 두개골의 형태는 두개골이 나타내는 선에 따라 인종적 특징을 뚜렷이 나타낼 뿐 아니라 같은 집단 내에서도 개인차가 크며 복잡한 곡면구조를 가지고 있다. 더욱이 머리 형태는 두개부 뿐만 아니라 얼굴부위와 연결되어 매우 세밀하고 복잡한 구조를 지니고 있을 뿐 아니라, 인간의 생명과 직결된 매우 중요한 부위이다. 그러므로 모자와 헬멧을 비롯하여 고글, 안전모, 안경 등 머리 및 얼굴에 착용되는 산업제품의 안전하고 유용한 설계를 위하여 이러한 부위들의 정확한 치수와 형태파악을 필요로 한다. (중략)

  • PDF

Designing Index for Assessing Structural Vulnerability of Supply Chain considering Risk Propagation (위험 전파 모형을 고려한 공급사슬의 구조적 취약성 평가 지표 설계)

  • Moon, Hyangki;Shin, KwangSup
    • The Journal of Society for e-Business Studies
    • /
    • v.20 no.2
    • /
    • pp.125-140
    • /
    • 2015
  • It is general that the impact of supply chain risk spread out to the whole network along the connected structure. Due to the risk propagation the probability to exposure a certain risk is affected by not only the characteristics of each risk factor but also network structure. It means that the structural connectivity among vertices should be considered while designing supply chain network in order to minimize disruption cost. In this research, the betweenness centrality has been utilized to quantitatively assess the structural vulnerability. The betweenness centrality is interpreted as the index which can express both the probability of risk occurrence and propagation of risk impact. With the structural vulnerability index, it is possible to compare the stability of each alternative supply chain structure and choose the better one.

Analysis of the effect of leakage on water head reduction in the pilot scale pipeline connected to the field pipeline. (현장 관망과 연결된 Pilot 스케일 관로에서 누수가 수두감쇠에 미치는 영향 분석)

  • Lee, Jeongseop;Ko, Dongwon;Lee, Taekwan;Yun, Seokjun;Choi, Dooyong;Kim, Sanghyun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.400-400
    • /
    • 2022
  • 관로 내 빈번히 발생하는 수격압의 발생은 관망 구조물에 피로가 누적되고 관벽에 손상을 발생시켜, 관로 내 누수가 다양한 형태로 생성된다. 관 내 누수가 발생되는 경우 관 내부의 수격압의 발생 시 생성되는 부압으로 인하여 외부 물질이 관으로 흡수되거나 혼합되어 스케일과 미생물의 생성되는 등 관 내의 수질에 악영향을 끼치며 마찰을 증가시켜 통수능이 감소하고 관리에 추가적인 비용을 발생시킨다. 이러한 영향을 방지하기 위해 관 내에서 생성되는 누수를 탐지하기 위하여 수격압을 발생시켜 압력파를 분석하거나 추적을 수행하는 여러 가지 연구들이 수행되었다. 본 연구에서는 현장 관망과 연결된 100A 대구경 관로에 관로 수압 발생장치를 연결하여 기존의 수격압을 발생시켜 분석하는 방법 대신 안전하고 용이한 방법인 압력파를 주입하여 실험을 수행하였다. 실험을 통해 획득한 데이터를 시간상에서 분석하고 Fourier 변환을 통한 빈도상 분석과 Wavelet 분석으로 신호주기에서 누수가 미치는 영향을 파악하였다. 실험 결과에서는 누수에 의한 영향으로 반사파가 직접적으로 변형되는 형태보다 시스템 전체에서 반영되어 수두가 감쇠되는 형태로 나타났다. Fourier 변환을 통해 무누수 조건과 누수조건의 비교에서 누수의 유무에 따른 신호의 형태가 차이를 보였다. 앞선 연구들에서의 누수의 특정한 위치를 찾아내는 형태 대신 신호처리 후 분석을 통해 시스템 전체에서 일어나는 감쇠를 통해 누수 존재 유무를 판별하고자 한다.

  • PDF

Safety Assessment for the Solar Cell Structure using Finite Element Analysis (유한요소법을 이용한 태양광 집전기 구조물에 대한 안전성 평가)

  • Lee, Yang-Chang;Lee, Joon-Seong;Lee, En-Chul;Lee, Ho-Jung
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.12a
    • /
    • pp.881-884
    • /
    • 2009
  • 태양열을 이용한 발전은 신재생에너지 사업으로 현재 각광을 받고 있는 분야 중의 하나이다. 본 논문에서는 3kv급 태양열 집전기를 유한요소법을 이용하여 돌풍이 불 때 풍하중에 의한 안전성을 평가하였다. 태양열 집전기는 옥외에 설치가 되므로 바람에 대한 영향을 가장 많이 받게 되는데 풍하중은 특히 강한 태풍이 불 때에 가장 높은 설계변수로 자중이나 프레임이 태양을 트레킹 할 때 생기는 동역학적인 변수보다도 크게 된다. 기존에 풍압력에 대한 산술식이 있지만 구조에 따라 적용하는 방법이 다르므로 돌풍이 불 때의 풍속을 적용, 유한요소법을 이용하여 우선 플레이트 프레임 표면에 발생하는 표면 압력을 계산하였다. 구한 표면 압력으로부터 플레이트 부분에 작용하는 하중으로 환산을 구조물에 대입하였고, 구조물이 크고 Mesh수에 문제로 인해 프레임을 두 부문으로 나누어서 포스트 부문과 플레이트 부분에 적용하여 해석하였다. 포스트의 경우에는 플레이트에서 받은 풍하중을 벡터로 나누어서 적용하였고 플레이트 부분에서 작용하는 자중을 고려하여 적용하였다. 플레이트의 경우 돌풍에 안정적이라 하더라도 변형량이 높을 경우를 적용하였다. 포스트 부분과 플레이트 연결부에서도 보강을 통하여 적정범위의 응력이 집전기에 문제가 발생할 수 있으므로 적정한 범위의 변형량을 유지하기 위해 설계변경 하여 안전한 구조물이 되도록 하였다.

  • PDF