• Title/Summary/Keyword: 구조적 평가

Search Result 10,963, Processing Time 0.036 seconds

Evaluation of Residual Stress using IITC of Experimental Stress Analysis on Concrete Structure (실험적 응력해석의 IITC 방식에 의한 콘크리트 구조물 잔류응력 평가)

  • Lee, Ho Beom;Han, Sang Hee;Jang, Il Young
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.2
    • /
    • pp.415-424
    • /
    • 2014
  • The carrying capacity of existing concrete structures is evaluated by the measured data from displacement and strain gauges for given loads and the results of numerical analysis that are compared with the measured ones. Consequently, this process could be accomplished in doing the direct measurement of residual stress on existing concrete. This study is concerned with the development of IITC (Instrumented Indentation Technique for Concrete) system which is based on the experimental stress analysis technique using non-destructive test method to evaluate the residual stress of concrete structures depending on the types of applied loadings in analysing indentation load - indentation depth curve derived experimentally on concrete surface. As a result, in this paper, almost all of systematized H/W and S/W were newly developed to estimate the residual stresses of concrete structures. Thus, the creation of new experimental equations for deriving residual stresses and automatical calculations of residual stresses using the empirical formula can lead to evaluate the structural resistances conveniently in the structures from construction phase to maintenance stage.

Assessment of flood control effects considering reservoir dam heightening and operation methods (저수지 운영기법을 고려한 저수지 둑높이기에 따른 홍수조절 효과 분석)

  • Kim, Si Nae;Hwang, Soon Ho;Jun, Sang Min;Kim, Ji Hye;Kang, Moon Seong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.258-258
    • /
    • 2020
  • 홍수기시 저수지 방류량으로 인한 피해를 저감하기 위한 방법으로는 구조적인 방법과 비구조적인 방법이 있으며, 구조적인 방법으로는 저수지 제체를 증고하는 등의 방법이 있고, 비구조적인 방법으로는 홍수 관리 수리시설물의 홍수기시 효율적인 운영 등이 있다. 그동안 둑높이기 저수지를 평가하는 다양한 연구에서는 제체의 증고를 통한 홍수조절능력 평가가 주를 이뤄왔으나 홍수기시 수공구조물의 운영방법별 홍수조절효과를 다각적으로 비교 연구한 연구는 부족한 실정이다. 따라서 본 연구에서는 황룡강 유역의 장성저수지를 대상으로 빈도별 홍수량을 산정하고, 둑높이기 전후의 수공구조물 운영 방법별 홍수조절능력을 평가하였으며, 효율적인 홍수조절방법을 검토하였다. 본 연구에서는 대상지구인 장성저수지의 지배관측소인 광주관측소의 과거 기상자료를 수집하였으며 HEC-HMS (Hydrologic Modeling System)을 이용하여 50년, 100년, 200년 빈도 및 PMF 유입시 설계홍수량을 산정하였다. 각 설계홍수량의 유입 시 저수지 운영 모의에는 HEC-5 (Hydrologic Engineering Center-5) 모형을 이용하였으며, 저수지 운영기법으로 Auto ROM 과 Rigid ROM 방식을 적용하였다. 또한 둑 높이기 전후 홍수조절능력 평가는 지체시간, 시간별 홍수위, 첨두홍수량, 홍수조절률 등 다양한 평가 지표를 고려하여 수행하였다. 본 연구에서 모의한 저수지 운영기법별 둑높이기 전 후의 홍수조절효과 평가를 통해 저수지의 최적 운영방안을 도출하고 둑높이기 저수지의 하류하천에 대한 치수계획의 수립 및 보완에 활용될 수 있을 것으로 기대된다.

  • PDF

A Study on Evaluation Method for Structural Suitability of Constructed Wetlands in Dam Reservoirs as an Ecological Water Purification System (생태적 수질정화시설로서 댐 저수지 인공습지의 구조 적정성 평가방안)

  • Bahn, Gwon-Soo
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.50 no.2
    • /
    • pp.23-40
    • /
    • 2022
  • Many constructed wetlands have been installed in dam reservoirs nationwide for ecological purification of watershed pollutants, but aging and reduced efficiency are becoming issues. To improve the management of constructed wetlands, an objective evaluation of structural suitability is required. This study evaluated 39 constructed wetlands of 15 dams. First, through fogus group interview(FGI), survey analysis, and analytic hierarchy process(AHP), eight evaluation items in the physical and vegetative aspects were selected and the evaluation criteria applied with weights were prepared. Second, as a result of the structural suitability evaluation, the average score of the overall constructed wetlands was 80.8, with 10 sites rated as 'good grade(91~100)', 22 sites rated as 'normal grade(71~90)' and 7 sites rated as 'poor grade(70 or less)'. The average score of physical structure evaluation was 52.6, with 14 sites rated as 'good', 21 sites as 'normal' and 4 sites as 'poor'. The suitability of location was good level in most constructed wetlands, but the water supply system, depth of water, ratio of length-to-width, and slope of flow channel were evaluated as 'normal' or less in constructed wetlands of 50% or more. Therefore, it was found that overall improvement was necessary for stable flow supply and flow improvement in the constructed wetland. The average score of vegetative structure evaluation was 28.2, and about 84% of them were identified as 'normal' or lower. As a result of analyzing the Spearman's correlation coefficient between the physical structure evaluation score and the vegetation structure evaluation score, there was a significant correlation(r = 0.728, p < 0.001), and it was found that each evaluation factor also influences each other. As a result of the case review of 6 constructed wetlands, the appropriateness of the evaluation results was confirmed, and it was found that the location, flow rate supply, and type of wetland had a great influence on the efficiency and operation of the wetland. Through this study, it will be possible to derive structural weaknesses of constructed wetlands in dam reservoirs as a nature-based solution, to prepare types and practical alternatives for improved management of each constructed wetland in the future, and to contribute to enhancing various environmental functions.

A Study on the Structural Analysis of Controllability in Chemical Processes (화학 공정의 제어성의 구조적 분석에 관한 연구)

  • Lee Byung Woo;Kim Yoon Sik;Yoon En Sup
    • Journal of the Korean Institute of Gas
    • /
    • v.3 no.1
    • /
    • pp.27-32
    • /
    • 1999
  • Chemical processes are highly nonlinear, multivariable systems and have complex structures. However, the controllability evaluation procedures are complicated, and the required information is very often unknown at the early design stage. Therefore, it is necessary to develop a procedure to evaluate and enhance controllability while designing processes and plants. To evaluate controllability in the design stage, it is most efficient to analyze process structure. Relative order can be used as a measure of 'physical closeness' between input and output variable. Structural controllability analysis using relative order is shown to be effective in a case study of heat exchanger network synthesis.

  • PDF

Expert System for FMECA Using Minimal Cut Set and Fuzzy Theory (최소절단집합과 퍼지이론을 이용한 FMECA 전문가 시스템)

  • Kim, Dong-Jin;Kim, Jin-O;Kim, Hyung-Chul
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.3
    • /
    • pp.342-347
    • /
    • 2009
  • Failure Mode Effects and Criticality Analysis (FMECA) is one of most widely used methods in modern engineering system to investigate potential failure modes and its severity upon the system. While performing FMECA, the experts evaluates criticality and severity of each failure mode and visualize the risk level matrix putting those indices to column and row variable respectably. Which results uncertainty in the result. In order to handle the uncertainty and conclude risk level matrix, this paper proposes a new FMECA procedure using minimal cut set (MCS) and fuzzy theory. Severity is calculated by proposed structural importance while criticality is determined by typical equipment failure rate data from IEEE Std 493. Finally, the risk level is compounded of these indices.

Electrical and Structural Properties of $CaF_2$ Film for TFT Applications (TFT응용을 위한 $CaF_2$ 박막의 전기적, 구조적 특성)

  • Kim, Do-Young;Choi, Suk-Won;Yi, Jun-Sin
    • Proceedings of the KIEE Conference
    • /
    • 1998.07d
    • /
    • pp.1355-1357
    • /
    • 1998
  • TFT의 게이트 절연막으로 사용되는 절연체는 우수한 절연특성과 낮은 계면포획전하밀도($D_{it}$)를 요구한다. 이에 본 연구에서는 우수한 절연특성을 가지며, 격자상수가 Si과 유사한 $CaF_2$의 증착 특성을 연구하였다. 진공증착법을 이용하여 p형 Si(100) 기판위에 $CaF_2$의 기판온도, 두께를 변화시켜 전기적, 구조적 특성을 평가하였다. 또한 Si 기판에 방향에 따른 박막의 특성을 조사하였다. 구조적 특성분석으로부터 Si(100) 기판의 경우 $CaF_2$는 (200)방향으로 주도적인 성장을 하였으며 기판온도를 상승시킴에 따라 (220)방향으로도 성장을 하는 것으로 나타났다. 열처리 전후의 구조적 특성은 SEM을 통해서 확인 할 수 있었다. 열처리 전후의 특성 변화로부터 저온($100^{\circ}C$이하)에서는 기판과의 성장방향과 동일하였으며 고온($200^{\circ}C$이상)에서는 기판방향과는 다른 방향 성장 결과를 얻었다. 전기적 특성평가를 위하여 C-V 특성을 평가하였다. C-V 특성으로부터 Si(100) 기판의 온도가 $100^{\circ}C$, $1455\AA$ 두께로 증착한$CaF_2$ 박막의 $D_{it}$$1.8{\times}10^{11}cm^{-1}eV^{-1}$로 낮은 값을 가지 고 있었으며 0.1MV/cm에서 누설전류밀도가 $10^{-8}A/cm^2$ 이었다.

  • PDF

Self Healing Bolted Joints System Using Shape Memory Alloy Washer (형상기억합금 와셔를 이용한 볼트접합부 자가치유 시스템)

  • Chang, Ha-Joo;Park, Seung-Hee;Lee, Chang-Gil;Kim, Tae-Heon;Nam, Min-Jun
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.315-318
    • /
    • 2011
  • 본 논문에서는 구조물 연결부의 실시간 손상 검색을 통해 이상이 감지되었을 경우 자가치유까지 가능한 지능형 볼트접합부 시스템에 관한 실험적 연구결과가 제시되었다. 지능형 센서인 PZT센서의 전기-역학적 커플링 특성을 이용한 전기역학적 임피던스 기반의 구조물 건전성 평가 방법이 사용되었다. 전기역학적 임피던스의 측정을 통한 계측값을 베이스라인 값과 비교하는 손상 평가를 통해 구조물 볼트접합부의 볼트풀림 손상을 진단하고, 손상은 손상지수 RMSD를 통하여 정량화되었다. 볼트접합부의 손상이 감지되었을 경우 형상기억합금(SMA) 와셔에 부착되어있는 히팅 필름에 전원을 가함으로써 형상기억합금에 열을 가하고, 가열된 형상기억합금 와셔는 축방향으로 팽창을 함으로써 잃었던 볼트의 토크력을 회복시켜주었다. 실험 결과, 제안된 전기역학적 임피던스 기반의 구조물 건전성 평가기법과 형상기억합금 와셔 기반의 볼트접합부 자가치유 시스템의 성능 평가와 검증이 이루어졌다.

  • PDF

System Reliability-Based Load-Carrying Capacity Evaluation of Steel Cable-Stayed Bridges (체계신뢰성방법에 기초한 강사장교의 내하력평가)

  • 조효남;임종권;박경훈
    • Computational Structural Engineering
    • /
    • v.11 no.4
    • /
    • pp.341-350
    • /
    • 1998
  • 본 논문은 교통하중에 대한 강사장교의 체계신뢰성에 기초한 체계적이며 실용적인 내하력평가 및 여용성평가 모형을 제안하였다. 고량 주형과 주탑의 조합상관 한계상태에 기초한 내하력평가를 위하여 개선된 조합상관식에 기초한 LRFR(Load and Resistance Factor Rating) 방법과 신뢰성에 기초한 시스템수준의 평가를 위해서 목표체계신뢰성지수의 항으로 표현되는 등가시스템저항강도에 의한 접근방법을 제안하였다. 또한 시스템의 여용성을 정의하기 위해서 체계신뢰성해석의 결과와 내하력평가 결과를 이용한 실제적인 시스템여용성 평가방법을 적용하였다. 제안한 체계신뢰성에 기초한 평가방법은 기존의 요소신뢰성 방법에 비해 구조물의 여용성을 충분히 반영하는 상당히 합리적이며 실제적인 결과를 보여주는 실용적인 방법으로 판단된다.

  • PDF

Structural Damage Evaluation of Large Span Roof Structure using Artificial Neural Network (인공신경망을 이용한 대공간구조물 구조손상평가)

  • Cho, Ja-Ock;Kim, Ji-Young;Yu, Eun-Jong;Kim, Mi-Jin;Kim, Dae-Young
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2010.04a
    • /
    • pp.335-338
    • /
    • 2010
  • 구조물의 상태평가는 구조물 고유의 동특성을 분석함으로써 평가할 수 있다. 구조물은 태풍, 지진 및 기타 외적 환경 등에 의하여 손상이 발생하고 이러한 구조물의 손상은 강성의 변화로 이어져 구조물의 동특성에 변화를 일으킨다. 따라서 손상 발생 전후의 동적응답을 각각 계측한 후 구조물 식별(Structural System Idetification)을 통하여 고유진동수 및 모드형상을 추출하고 수학적인 기법을 사용하여 구조물을 구성하고 있는 개별 부재 혹은 부재 그룹의 강성을 비교함으로써 손상의 발생여부 및 손상정도를 추정할 수 있다. 본 연구에서는 지붕트러스 구조물에 대하여 손상평가를 수행하고 이를 검증할 수 있는 Mock-up 구조물을 설계 및 시공하였다.

  • PDF

Convergence Effect of Simulation Training on Bleeding Amount Estimation in Trauma (시뮬레이션 교육이 외상성 출혈의 출혈량 추정에 미치는 융합적 영향)

  • Yang, Hyun-Mo;Kim, Gyoung-Yong
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.4
    • /
    • pp.69-76
    • /
    • 2021
  • The purpose of the study is to examine the visual evaluation of bleeding amount in hemorrhagic shock in paramedic students. Through manikin simulation training, paramedic students were able to have confidence with estimation of bleeding amount in the prehospital settings. Three rescue training manikins were placed in supine position and artificial blood was poured between the abdomen and pelvis. The bleeding evaluations of 700 mL, 1200 mL, and 1700 mL were performed before and after simulation training. Paramedic students underestimated the amount of bleeding in the trauma situation, and it was found that it was difficult for the students to evaluate the accurate amount of bleeding with a single simulation.