• Title/Summary/Keyword: 구조적 안정도

Search Result 5,265, Processing Time 0.036 seconds

A Study of Recycling Lithium-ion Battery Graphite by Eco-friendly Citric Acid Treatment Method (친환경 구연산처리를 통한 폐흑연 재활용 연구)

  • Dong-kyu Son;Won Jin Park;Jun Young Kim;Ji Hui Yun;Jung Eun Hyun
    • Korean Chemical Engineering Research
    • /
    • v.62 no.3
    • /
    • pp.246-252
    • /
    • 2024
  • In this study, impurities such as Li and F were removed from waste graphite through citric acid treatment, and changes in structural properties, capacity, and cycle stability of regenerated graphite were observed accordingly. Regenerated graphite pretreated in a nitrogen atmosphere was treated with citric acid, and its structure and characteristics were analyzed through SEM (Scanning Electron Microscope), FT-IR (Fourier Transform Infrared spectroscopy), XRD (X-ray Diffraction), and XPS (X-ray Photoelectron Spectroscopy). Waste graphite that was not treated with acid had a rapid decrease in capacity before 70 cycles, but graphite that had been treated with citric acid showed a capacity of 302.9 mAh g-1 and a capacity retention rate of 93.1% at 100 cycles. In addition, despite changes in current density in rate performance, samples treated with citric acid showed 340.2 mAh g-1 performance at 1.0C without change in capacity. As a result, it was confirmed that citric acid treatment not only effectively removed impurities and showed a high capacity retention rate, but also showed stability even at high current densities.

An Experimental Study on Dynamic Behavior Evaluation of Transitional Track (접속부 궤도의 동적거동분석을 위한 실험적 연구)

  • Cho, Sung-Jung;Choi, Jung-Youl;Chun, Dae-Sung;Kim, Man-Cheol;Park, Yong-Gul
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.1379-1385
    • /
    • 2007
  • In domestic transitional zone design, there is regulation to prevent generation of irregular substructure behaviors that negatively influence in prevention of plasticity settlement on approach section and contact section as well as relieve overall track rigidity by reducing sectional foundation and track stiffness difference, but design guideline that considers dynamic behavior of transitional track in actual service line is very insignificant. Therefore in this study, characteristics of transitional track dynamic behaviors by substructure stiffness are researched and measured dynamic response of transitional track by substructure stiffness in order to prove correlation between substructure and track and calculate elasticity(stiffness) and track load of transitional track by using measurement and formula to provide basic information for developing design guideline considering dynamic behavior of service line transitional track.

  • PDF

Anaerobic Organic Wastewater Treatment and Energy Regeneration by Utilizing E-PFR System (E-PER 반응기를 이용한 유기성 폐기물의 혐기성 처리와 재생에너지 생산에 관한 연구)

  • Kim, Burmshik;Choi, Hong-Bok;Lee, Jae-Ki;Park, Joo Hyung;Ji, Duk Gi;Choi, Eun-Ju
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.16 no.2
    • /
    • pp.57-65
    • /
    • 2008
  • Wastewater containing strong organic matter is very difficult to treat by utilizing general sewage treatment plant. but the wastewater is adequate to generate biomass energy (bio-gas; methane gas) by utilizing anaerobic digestion. EcoDays Plug Flow Reactor (E-PFR), which was already proved as an excellent aerobic wastewater treatment reactor, was adapted for anaerobic food wastewater digestion. This research was performed to improve the efficiency of bio-gas production and to optimize anaerobic wastewater treatment system. Food wastewater from N food waste treatment plant was applied for the pilot scale experiments. The results indicated that the efficiency of anaerobic wastewater treatment and the volume of bio-gas were increased by applying E-PFR to anaerobic digestion. The structural characteristics of E-PFR can cause the high efficiency of anaerobic treatment processes. The unique structure of E-PFR is a diaphragm dividing vertical hydraulic multi-stages and the inversely protruded fluid transfer tubes on each diaphragm. The unique structure of E-PFR can make gas hold-up space at the top part of each stage in the reactor. Also, E-PFR can contain relatively high MLSS concentration in lower stage by vertical up-flow of wastewater. This hydraulic flow can cause high buffering capacity against shock load from the wastewater in the reactor, resulting in stable pH (7.0~8.0), relatively higher wastewater treatment efficiency, and larger volume of bio-gas generation. In addition, relatively longer solid retention time (SRT) in the reactor can increase organic matter degradation and bio-gas production efficiency. These characteristics in the reactor can be regarded as "ideal" anaerobic wastewater treatment conditions. Anaerobic wastewater treatment plant design factor can be assessed for having 70 % of methane gas content, and better bio-gas yielding and stable treatment efficiency based on the results of this research. For example, inner circulation with generated bio-gas in the reactor and better mixing conditions by improving fluid transfer tube structure can be used for achieving better bio-gas yielding efficiency. This research results can be used for acquiring better improved regenerated energy system.

  • PDF

Characteristics and Status of Roof Tile Buildings of Pungnaptoseong Fortress (풍납토성 기와건물지의 성격과 위상)

  • SO Jaeyun
    • Korean Journal of Heritage: History & Science
    • /
    • v.56 no.3
    • /
    • pp.46-59
    • /
    • 2023
  • Various Baekje ground-level building sites have been identified, in Pungnaptoseong Fortress, including Mirae Village's site E-1. However, building site E-1 is the only one with excavated roof tiles that are directly connected to the building site. As for building sites E-2, D-1, and D-2, which are comparable to site E-1, it is very possible that they had tiles on the roof based on their jeoksim (blocking facilities for roof slopes) and building structures. Also, although they are semi-underground pit structures, pit building sites A-30 and modern apartment site A-5, as well as the No.44 remains of Gyeongdang District, which is closer to a ground-level type, the buildings with tiles may have been constructed in the form of partial tile roofs rather than full-face tile roofs. Therefore, there may be several reasons behind the use of tiles on roofs in the early days, but the primary background of the building's authoritative function would have been considered first. Considering that China and Japan started using tiles on nationally important buildings such as palaces, temples, and ritual buildings, it may be presumed that Baekje began using tiles from the time it centralized power. It is believed that Baekje's early roof tile buildings evolved from rudimentary residential architecture to advanced public architecture, taking into consideration fire prevention and structural stability in large buildings. It is difficult to find similar cases in Korea with structural features such as the elevated foundations or underground stone foundations that can be found in Mirae Village building site E-1. Rather, similar architectural techniques can be found in China and Japan. In China, similar construction techniques were discovered in buildings of worship that were primarily built in the palace surroundings, such as Jangan Castle. Based on this, it appears that roof tile building sites, such as site E-1, that have been discovered have a strong correlation with the characteristics of buildings of worship, and ground type buildings, such as sites D-1 and D-2, are important facilities that are related to important public facilities such as state-run warehouses. This provides many implications regarding the early Baekje city structure.

Development of Light-weight Fire Protection Materials Using Fly Ash and Light-weight Aggregate (플라이애시 및 경량골재를 활용한 경량 내화성 마감재료 개발)

  • Song, Hun;Chu, Yong-Sik;Lee, Jong-Kyu;Lee, Sea-Hyun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.6 no.4
    • /
    • pp.95-102
    • /
    • 2012
  • The serious issue of tall building is to ensure the fire resistance of high strength concrete. Therefore, Solving methods are required to control the explosive spalling. The fire resistant finishing method is installed by applying a fire resistant material as a light-weight material to structural steel and concrete surface. This method can reduce the temperature increase of the reinforcement embedded in structural steel and concrete at high temperature due to the installation thickness control. This study is interested in identifying the effectiveness of light-weight fire protection material compounds including the inorganic admixture such as fly ash, meta-kaolin and light-weight aggregate as the fire resistant finishing materials through the analysis of fire resistance and components properties at high temperature. Also, this paper is concerned with change in microstructure and dehydration of the light-weight fire protection materials at high temperatures. The testing methods of fire protection materials in high temperature properties are make use of SEM and XRD. The study results show that the light-weight fire resistant finishing material composed of fly ash, meta-kaolin and light-weight aggregate has the thermal stability of the slight decrease of compressive strength at high temperature. These thermal stability is caused by the ceramic binding capacity induced by alkali activation reaction by the reason of the thermal analysis result not showing the decomposition of calcium hydrate. Developed light-weight fire protection materials showed good stability in high Temperatures. Thus, the results indicate that it is possible to fireproof panels, fire protection of materials.

  • PDF

Anatomical characteristics of the midpalatal suture area for miniscrew implantation using CT image (정중구개봉합부의 해부학적 구조에 관한 전산화 단층촬영을 이용한 연구)

  • Park, Young-Chel;Lee, Jong-Suk;Kim, Doo-Hyung
    • The korean journal of orthodontics
    • /
    • v.35 no.1 s.108
    • /
    • pp.35-42
    • /
    • 2005
  • There is lack of data for the amount of vertical bone in the midpalatal region for miniscrew implantation. The purpose of this study was to measure the structure of the midpalatal suture area using CT image and V-works 4.0 program (Cybermed Inc, Seoul, Korea). CT images of 14 male and 14 female adults were reconstructed. In detail, it was 1) to measure the length of maxilla on the midsagittal plane 2) to measure vertical bone height in the midpalatal area 3) to establish the zone of safety for miniscrew implantation. The following results were obtained. The mean length of ANS-PNS was 51.08mm in males and 47.34mm in females. There was a statistically significant difference between males and females (p<0.05). The vertical bone height of the midpalatal suture area was above 0mm except for 6mm posterior from the central Point of ANS-PNS in males The zone of safety was located 19.43mm posterior from the ANS in males while it was 17.62mm in females along the palatal plane. These results support that the safety zone of the midpalatal area is suitable for screw implantation. Midpalatal miniscrew implantation is a powerful tool in modern orthodontics Through many applications. it can expand the modern orthodontic field.

Uplift Testing and Load-transfer Characteristics of Model Drilled Shafts in Compacted Weathered Granite Soils (화강풍화토 지반에 타설된 소형 현장 타설 말뚝의 인발시험 및 하중 전이 특성)

  • 임유진;서석현
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.4
    • /
    • pp.105-117
    • /
    • 2002
  • In the design of foundations for the super-structures such as transmission towers and oil-platforms, the foundations must be considered as a medium to resist cyclic tensile forces. In this study, the uplift capacity of the drilled shaft used as the medium resisting to this pattern of forces is investigated by performing cyclic uplift test of a small model-drilled shaft constructed in compacted granite soil in a steel chamber. In this test, the behavioral difference between a pile loaded on the top of the pile and a pile loaded at the bottom of the pile was investigated intensively. The load transfer curves obtained from the test were investigated by changing the confining pressure in the chamber. The load tests also included creep test and cyclic test. It is found from the tests that uplift capacity of the shaft loaded at the bottom is greater than that of the shaft loaded on the top of the pile. It is found also from the creep test that the pile loaded at the bottom was more stable than the shaft loaded on the top. If a pile loaded at the bottom is pre-tensioned, the pile will be most effective to the creep displacement. It is found also from the cyclic tests that apparent secant modulus obtained in a cycle of the load increases with the number of cycles.

Establishment of Urban Flood Prevention System of Cheongna District (청라지구 도시홍수방어체계 수립 방안)

  • Park, Jong-Pyo;Park, Chang-Youl;Yu, Chang-Hwan;Lee, Sang-Ho
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.1519-1523
    • /
    • 2009
  • 비상대처계획수립을 위한 홍수방어체계 구축은 방재적 측면에서 가능최대강수량 유입시 댐 붕괴 조건에 대한 하류지역의 침수범람지도와 대피경로 작성에 관한 내용이 주된 관심사였다. 그러나, 현재 국내에서 계획되고 있는 자연형하천 조성사업, 물순환시스템 조성공사 등에서는 기존의 비상대처계획수립과는 차별화된 홍수시 이용자 대피계획 및 각종 수리구조물의 운영에 대한 비상경보 발령체계 수립을 요구하고 있다. 본 연구는 청라지구 중앙호수와 공촌천, 심곡천 연결부의 하천 배수문 운영, 내부수로 수위조절을 위한 배수펌프 계획과 연계한 상황별 홍수조절 방안을 수립하고 강우, 수위 관측에 의한 비상시 경보발령 기준을 제시하였다. 하천배수문 운영에 따른 중앙호수 저류시설 활용효과 분석을 위하여 100년, 200년빈도 홍수 유입시 조위조건별 내수위 변화를 계산하였다. 수치모의는, 공촌천-중앙호수-심곡천을 연계운영을 위하여 HEC-RAS의 Full Network를 이용하였으며 심곡천, 공촌천과 중앙호수를 연결하는 하천배수문은 계획홍수위 El. 3.75m 이상인 경우 개별적으로 개방하도록 하였다. 모형 수행결과, 계획빈도 홍수시 하천배수문 개방을 통한 중앙호수 저류지 활용방안은 200년빈도, 약최고고조위 내습시에도 청라지구 전체의 치수안정성을 확보할 수 있다. 그러나, 200년빈도 고극조위 이상의 기상조건인 경우에는 심곡천 홍수위가 계획제방고 El. 4.55m를 넘어 비상대처계획 수립이 필요하다. 분석결과를 바탕으로 도시홍수방어체계 구축을 위하여 3단계의 치수안정성 확보 계획을 수립하였으며 하천배수문 개방 차단계획을 고려하여 계획빈도이하 홍수, 계획빈도이상 홍수, 비상상황시로 구분하여 상황별 홍수조절방안을 제시하였다. 또한, 500년빈도 홍수시 폭풍해일을 고려한 하천 수위 분석을 통하여 비상경보 발령체계를 정량적으로 분석하였다. 비상경보발령은 공촌천 수위 El. 3.85 m, 심곡천 수위 El. 3.73 m, 강우강도 39.7mm/hr 이상시이다. 본 연구는 홍수시 모니터링시스템에 의한 비상경보 발령체계 수립을 위한 수위 및 강우조건을 정량적으로 제시하여 차후 개발되는 신도시 물순환시스템의 상황별 홍수조절 방안 및 모니터링 시스템에 의한 경보발령 기준 수립시 활용가능 할 것으로 기대된다.

  • PDF

A Study on the Distribution of Underground Plant Biomass and its Effect on the Stream Bank Stability (농촌 소 하천 제방 상의 식물 근계 분포 현황에 따른 제방 지지 역할에 관한 연구 - 경남 진주시 농촌 소하천 유역의 대나무와 잔디를 대상으로 -)

  • Lee, Chun-Seok;Kim, Jung-Uk
    • Journal of Korean Society of Rural Planning
    • /
    • v.5 no.1 s.9
    • /
    • pp.95-103
    • /
    • 1999
  • The purpose of this study is to find out the distribution of underground biomass and its soil stabilizing effects. Bamboo and grass were examined and compared. 1. Thirty 'soil & root' samples were collected to the depth of 30cm with Impact-corer, and then divided into three sections(0-10cm, 10-20cm, 20-30cm). Each piece had a volume of $950cm^3$ and the underground biomass was separated from the soil particles by washing with flowing water. The average underground biomass rates of bamboo and grass were 10.8% and 4% of each sample, respectively. The rate of grass root biomass declined with depth, but the bamboo root biomass was at peak at around 20cm depth. 2. The shear strength was measured with con-penetration tester at each sample collecting site. Three measurements were made at each depth(0-10cm, 10-20cm, 20-30cm) and were compared with the impact counts needed to insert the corer to the depth of 30cm. The shear strength has clear correlations with underground biomass. The more underground biomass, the higher shear strength. The shear strength of bamboo was about three times larger than the grass.

  • PDF

EC-STM Studies on Electrochemical Preparation of Si(111)-H Surfaces (Si(111)-H 표면의 전기화학적 제조에 관한 전기화학적 주사터널링현미경법 연구)

  • Bae, Sang-Eun;Lee, Chi-Woo
    • Journal of the Korean Electrochemical Society
    • /
    • v.5 no.3
    • /
    • pp.111-116
    • /
    • 2002
  • Electrochemical scanning tunneling microscopy was employed to study the evolution of surface morphology during electrochemical preparation of Si(111)-H from Si(111) oxide. Anodic dark current of cyclic voltammogram in 0.2M $NH_4F$ solution (pH 4.7) decreased as the number of cycles increased and remained nearly constant after the second cycle. Then, the Si(111) oxide was entirely stripped, which was followed by H termination on the Si(111) surface. Hydrides at kink and step sites were etched more rapidly than on the terrace, which remained triangle pits with [112] oriented steps where existed stable monohydride. Then, triangle pits deepened. During chronomamperometry at 0.4V anodic dark current shoulder appeared and decreased slowly, indicated the stripping of Si(111) oxide and the formation of stable (112) oriented steps with monohydride. Additionally, the etching mechanism of Si(111)-H in 0.2M $NH_4F(pH 4.7)$ solution at +0.4V was discussed.