• Title/Summary/Keyword: 구조적 손상

Search Result 1,829, Processing Time 0.031 seconds

Linkage of Damage Evaluation to Structural System Reliability (손상평가와 구조물 신뢰성과의 연계)

  • Park, Soo Yong
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.1
    • /
    • pp.41-50
    • /
    • 2003
  • Nondestructive Damage Evaluation (NDE) techniques yield the damage location and its size from the modal characteristics of pre-damaged and post-damaged structures. To predict the system reliability of the aging structure, results from the NDE are integrated into the element/component failure probabilities. The element/component failure probabilities can be calculated from failure functions for each element/component with the aid of techniques from a structural reliability analysis. In this paper, a method to estimate the system reliability of a structure that is based on the reliabilities of elements/components in a given structure is presented. The efficacy of the combination of the nondestructive damage detection and the structural reliability evaluation is demonstrated using pre-damaged and post-damaged modal data obtained from numerical simulations of a rigid frame.

Damage monitoring scheme of caisson-type breakwaters (Caisson식 방파제의 손상 모니터링 기법)

  • 박재형;이병준;이용환;김주영;김정태
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.151-156
    • /
    • 2004
  • 최근 국내외에서 국제무역 물량의 증대에 따라 대규모 항만 건설 공사가 진행되고 있으며, 이에 경제성, 시공성이 뛰어난 Caisson 형식의 구조물이 많이 사용되어지고 있다. 특히 항만 및 어항의 외곽시설인 방파제는 계류선박의 안전과 하역 및 적화를 용이하게 하는 중요한 구조물이다. 따라서, 본 연구에서는 Caisson식 방파제에 태풍, 충격력과 같은 몇 가지 외력 조건에 대하여 구조 해석을 실시하여 손상메커니즘을 분석하였다 이러한 손상 메커니즘에 따라 손상을 인위적으로 발생시켜 손상 위치 탐색을 수행하였다.

  • PDF

Structural Restoration for the Electric Power Transmission Tower Damaged by Foundation Settlements (기초침하에 의해 손상된 송전철탑 구조물의 구조성능개선)

  • Lee, Ho Beom;Park, Jong Kwon;Kim, Il Soo;Jang, Il Young;Song, Jae Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.2
    • /
    • pp.83-93
    • /
    • 2013
  • Generally the capacities of electric power transmission tower's members are improved by increasing their stiffness nature through injection of grout or attachment of other structural stiffeners. Those are for upgrading their axial strength by fulfillment of proper materials into pipe members, increment of member dimension by addition of section, or a combination of the two. However the use of innovative and unusual procedures would be positively recommended for getting more stable state. It is that buckled members are replaced with lengthened and strengthened members. In providing the structural restoration procedures for the existing electric power transform tower whose main members have been damaged due to unequal foundation settlement, structural damage inspection works and numerical analyses for the damaged one and the restored one were done in detail at first. secondarily member-exchanging works using a newly-generated jacking system and strengthened members were achieved. This figures are to point clearly to inherent advantages attending the management of the towers.

Diagnostics of Truss Structures via Vibration Monitoring (진동감시를 통한 트러스 구조물의 진단)

  • Park, Soo-Yong;Kim, Jeong-Tae;Kim, Yeon-Bok
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.1 no.2 s.2
    • /
    • pp.63-74
    • /
    • 2001
  • In this paper the feasibility of Nondestructive Damage Detection (NDD) in large structures is demonstrated via simulating vibration monitoring of such structures. The theory of NDD for truss type structures is formulated. To examine the feasibility of the theory, a finite element model of a 3-D truss structure, which consists of sixteen bays and includes 246 elements, is developed to simulate damage. Four damage cases are simulated numerically and the cases range from the structure being damaged in one location to the structure being damaged in three locations. For the given modal parameters, this study reveals very good results for small amounts of damage as well as large damage.

  • PDF

Damage Detection of Shear Building Structures Using Dynamic Response (동적응답신호를 이용한 전단형 건물의 손상추정)

  • Yoo, Suk-Hyeong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.3
    • /
    • pp.101-107
    • /
    • 2014
  • Damage location and extent of structure could be detected by the inverse analysis on dynamic response properties such as frequencies and mode shapes. The dynamic response of building structures has many noise and affected by nonstructural members and, above all, the behavior of building structure is more complex than civil structure and this makes the damage detection difficult. In recent researches the damage is detected by the indirect index such as sensitivity or assumed values. However, for the more reasonable damage detection, it needs to use the damage index directly induced from dynamic equation. The purpose of this study is to provide the damage detection method on shear building structures by the damage index directly induced from dynamic equation. The provided damage index could be estimated from measured mode shape of undamaged structure and frequency difference between undamaged and damaged structure. The damage detection method is applied to numerical analysis model such as MATLAB and MIDAS GENw for the verification. The damage index at damaged story represents (-) sign and 15 times than other undamaged sories.

Temperature Compensation Using Principal Component Analysis for Impedance-based Structural Health Monitoring (주성분 분석을 이용한 임피던스 기반 구조물 건전성 모니터링의 온도보상기법)

  • Shim, Hyo-Jin;Min, Ji-Young;Yun, Chung-Bang
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.32-35
    • /
    • 2011
  • 전기역학적 임피던스(electromechanical impedance)를 이용한 구조물 건전성 모니터링(structural health monitoring; SHM) 기술은 구조물의 주요 부재에 압전센서를 부착하여 이로부터 획득한 임피던스 신호의 변화를 관찰함으로써 구조물의 국부적 상태를 실시간으로 진단하는 것이다. 임피던스는 손상뿐만 아니라 외부 온도에도 민감하게 반응하기 때문에 구조물 진단 결과에 상당한 오차를 유발할 수 있으므로 이에 대한 보상을 수행해야 한다. 따라서 본 논문에서는 온도변화가 임피던스 기반 진단 결과에 미치는 영향을 PZT 센서를 사용하여 실험적으로 연구하였다. 리액턴스(reactance)의 주성분 분석(Principal Component Analysis; PCA)을 통해 도출된 첫번째 주성분과 저항(resistance)으로부터 계산된 손상지수 사이의 관계를 분석함으로써, 온도변화에 의해 구별되지 않았던 손상을 보다 확연하게 구별 할 수 있음을 확인하였다.

  • PDF

Understanding the Asymptotic Convergence of Domain of Attraction in Extreme Value Distribution for Establishing Baseline Distribution in Statistical Damage Assessment of a Structure (통계적 구조물 손상진단에서 기저분포 구성을 위한 극치분포의 점근적 수렴성 이해)

  • Kang, Joo-Sung;Park, Hyun-Woo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.2 s.54
    • /
    • pp.231-242
    • /
    • 2009
  • The baseline distribution of a structure represents the statistical distribution of dynamic response feature from the healthy state of the structure. Generally, damage-sensitive dynamic response feature of a structure manifest themselves near the tail of a baseline statistical distribution. In this regard, some researchers have paid attention to extreme value distribution for modeling the tail of a baseline distribution. However, few researches have been conducted to theoretically understand the extreme value distribution from a perspective of statistical damage assessment. This study investigates the asymptotic convergence of domain of attraction in extreme value distribution through parameter estimation, which is needed for reliable statistical damage assessment. In particular, the asymptotic convergence of a domain of attraction is quantified with respect to the sample size out of which each extreme value is extracted. The effect of the sample size on false positive alarms in statistical damage assessment is quantitatively investigated as well. The validity of the proposed method is demonstrated through numerically simulated acceleration data on a two span continuous truss bridge.

Rapid demolition of locally damaged steel truss bridge (국부손상 철골 교량 구조물의 긴급해체 사례)

  • Park, Hoon;Noh, You-Song;Suk, Chul-Gi
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2017.11a
    • /
    • pp.197-198
    • /
    • 2017
  • 인공재해와 자연재해로 인해 발생하는 비정상 하중에 의해 국부손상이 발생된 철골 교량 구조물은 추가적인 2차 붕괴의 위험요소들을 내재하고 있어 신속한 전면 해체가 요구된다. 본 시공 사례는 건설실패와 태풍 및 지진으로 국부손상이 발생된 철골 트러스 구조의 교량의 긴급해체를 위해 발파해체 공법을 적용한 사례이다. 철골 부재의 절단을 위해 성형폭약이 필요하지만 현지에서 수급이 불가능한 상태이기 때문에 장약용기를 직접 제작하고 에멀젼 폭약을 충전하여 만든 성형폭약을 이용하여 발파해체에 적용하였다. 직접 제작한 성형폭약을 이용하여 발파해체한 결과 철골 부재가 정확히 절단되면서 교량의 중앙부가 수직자유낙하하고, 교량의 양 끝단은 지지부를 중심으로 회전낙하 하였다. 또한 존치 구조물 및 주변에 피해가 발생하지 않았으며, 발파 후 파쇄 상태는 매우 양호하였다. 이로 인해 직접 제작한 성형폭약의 절단 성능을 확인할 수 있었으며, 신속하고 안전하게 국부손상이 발생된 구조물을 해체하였다.

  • PDF

Multiple Damage Detection of Pipeline Structures Using Statistical Pattern Recognition of Self-sensed Guided Waves (자가 계측 유도 초음파의 통계적 패턴인식을 이용하는 배관 구조물의 복합 손상 진단 기법)

  • Park, Seung Hee;Kim, Dong Jin;Lee, Chang Gil
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.3
    • /
    • pp.134-141
    • /
    • 2011
  • There have been increased economic and societal demands to continuously monitor the integrity and long-term deterioration of civil infrastructures to ensure their safety and adequate performance throughout their life span. However, it is very difficult to continuously monitor the structural condition of the pipeline structures because those are placed underground and connected each other complexly, although pipeline structures are core underground infrastructures which transport primary sources. Moreover, damage can occur at several scales from micro-cracking to buckling or loose bolts in the pipeline structures. In this study, guided wave measurement can be achieved with a self-sensing circuit using a piezoelectric active sensor. In this self sensing system, a specific frequency-induced structural wavelet response is obtained from the self-sensed guided wave measurement. To classify the multiple types of structural damage, supervised learning-based statistical pattern recognition was implemented using the damage indices extracted from the guided wave features. Different types of structural damage artificially inflicted on a pipeline system were investigated to verify the effectiveness of the proposed SHM approach.

Tensile Strength Change of Circular Structural member with Artificial Sectional Surface Damage (인위적 표면 단면손상 수준에 따른 원형 부재의 인장성능 변화)

  • Ha, Min-Gyun;Kwon, Tae-Yun;Lee, Won-Hong;Ahn, Jin-Hee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.3
    • /
    • pp.100-109
    • /
    • 2021
  • This study was examined the tensile strength change of a circular tubular member with artificial sectional damage on its surface to consider surface sectional damage by corrosion. The tensile strength tests were conducted using circular tubular specimens with artificial sectional damage considering sectional damaged height and width on its surface according to the corrosion level. From the tensile strength test results, it is confirmed that tensile strength of the circular tubular specimens was affected by the damaged circumference (damaged width), not damaged length (damaged height) and their tensile failures were appeared at the minimum section of the artificial sectional damage part. Nonlinear finite-element analyses were conducted considering equivalent sectional damage effect on sectional damaged part in tensile specimens to examine the change in the tensile strength of tubular specimens with artificial sectional damage since it is difficult to estimate the sectional damaged surface condition of the specimens clearly. From the nonlinear finite element analysis results for the tensile test specimens, tensile strengths of test specimens with irregular sectional damaged surface were relatively evaluated to be highly decreased than these of FE analysis model with equivalent sectional damage. Therefore, residual tensile strengths of tensile members with irregular sectional damage as local corrosion can be evaluated and predicted using correlation coefficient between tensile test results and FE analysis results with equivalent sectional damage.