• Title/Summary/Keyword: 구조시험(structural test)

Search Result 1,295, Processing Time 0.03 seconds

Design and Evaluation of Volute Casings for a Liquid Rocket Turbopump (액체로켓 터보펌프 벌류트 케이징의 구조설계 및 시험)

  • Yoon, Suk-Hwan;Jeon, Seong-Min;Kim, Jin-Han
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.775-776
    • /
    • 2010
  • Volute casings for a liquid rocket turbopump are designed and evaluated in a structural point of view. After the design step volute casings are manufactured by metal casting process, and then they are subjected to burst test for verification. In the burst test strains at several points are measured and compared with predicted values.

  • PDF

A Study of Accelerated Corrosion Test and Chloride Penetration Analysis with Artificial Seawater Immersion Condition (인공해수 침지조건에 따른 부식촉진시험과 염화물침투해석에 대한 연구)

  • Park, Sang-Soon;Jeong, Ji-Won
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.1
    • /
    • pp.93-100
    • /
    • 2014
  • Steel reinforcement buried in concrete structure in submerged zone does not easily become corroded due to lack of dissolved oxygen. For that reason, accelerated corrosion test in submerged state is performed with an electrochemical method, which is not suitable for actual corrosion mechanism and makes it difficult to find relevance with long-term behavior. In this study, accelerated corrosion test was performed with the temperature and chloride concentration as main variables in order to establish a method for accelerated corrosion test in submerged zone. Corrosion was determined by the result of reinforcement corrosion monitoring based on galvanic potential measurement and half-cell potential method. The accelerated corrosion test result showed that temperature had the most dominant influence. To determine the chloride content, chloride concentration by depth in the test sample was measured. With the same conditions, chloride penetration interpretation was performed by DuCOM, a FEM durability interpretation program. Also, a test was performed to measure dissolved oxygen according to soaking conditions of artificial seawater, which was used for verifying the validity of the accelerated corrosion test result.

Centrifuge-Shaking Table Test for Seismic Performance Evaluation of Subway Station (지하역사의 내진성능평가를 위한 원심모형 진동대 시험)

  • Kim, Jin Ho;Shin, Min Jung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.3
    • /
    • pp.99-105
    • /
    • 2011
  • When a certain magnitude earthquake occurs, serious damage for human and properties is a major concern for most of the subway stations which were not applied for earthquake resistant design. Consideration and experimental verification for ground and structural behavior based on soil-structure interaction relation are required to evaluate seismic performance of the subway station as embedded structures. For 1/60 scaled subway station model, centrifuge modeling shaking table test is performed using Kobe and Northridge earthquakes. Compare to displacements and moments of the underground and structure obtained by soil response analysis and response displacement method based on experimental results, this paper shows how to evaluate seismic performance of subway station.

Pullout and Flexural Performance of Structural Synthetic Fibers by Geometry and Sectional Area Change (구조용 합성섬유의 형상 및 단면적 변호에 따른 부착 및 휨 성능)

  • Won, Jong-Pil;Back, Chul-Woo;Park, Chan-Gi;Han, Il-Yeong;Kim, Bang-Lae
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.5
    • /
    • pp.643-649
    • /
    • 2003
  • The purpose of this study were evaluated to flexural and bond performance by sectional area and geometry change through bond and flexural test of a structural synthetic fiber. Six deformed structural synthetic fibers were investigated and pullout and flexural test was conducted. Included parameters is three different geometries of fiber and two of fiber sectional area. The test result shows that the cycles and amplitude of structural synthetic fiber increased, pullout load and pullout fracture energy decreased and flexural strength increased, if sectional area is same. The sectional area increased, pullout load and pullout fracture energy increased and flexural strength decreased, if cycles and amplitude of structural synthetic fiber is same. Based on test results, structural performance of the concrete could know that is influence by pullout performance of fiber as well as various factor (fiber number, material properties etc).

Development of Main Wing Structure of Long Endurance Electric Powered UAV (24시간 장기체공 전기 동력 무인항공기 주익 구조 개발)

  • Park, Sang Wook;Shin, Jeong Woo;Park, Ill Kyung;Lee, Mu-Hyoung;Woo, Dae Hyun;Kim, Sung Joon;Ahn, Seok Min
    • Aerospace Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.1-9
    • /
    • 2013
  • In order to increase endurance flight efficiency of long endurance electric powered UAV with solar cell, the light weight airframe design techniques are important. In this paper, the design of the main wing of electric powered UAV manufactured using Mylar film and fiber reinforced composite was conducted in order to achieve weight reduction and structural integrity of the structure. The shape of spar and size were determined using beam theory analysis. The finite element analysis of the wing was performed under various load condition derived from flight environment of EAV-2H. Finally, the static strength test of the main wing was conducted to verify structural integrity. It was found that the developed main wing weigh less than 42% than the previous EAV-2 and the main wing passed static strength test under ultimate load.

Structural Design and Proof Test of a 2MW Wind Trubine Blade (2MW 로터 블레이드 구조설계 및 인증시험)

  • Bang, Jo-Hyug;Kim, Yang-Soo;Ryu, Ji-Yune;Kim, Doo-Hoon;Park, Sun-Ho;Park, Byoung-Jun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.349-352
    • /
    • 2007
  • A GFRP based composite blade was developed for a 2MW wind energy conversion system of type class IIA. The blade sectional geometry was designed to have a general shell-spar and shear web structure. The load cases specified in the IEC61400-1 international specification were considered. For withstanding all relevant extreme loads, the structural analysis for the complete blade was performed using a commercial FEM code. The static load carrying capacity, blade tip deflection and natural frequencies were evaluated to satisfy the strength and stability requirements in accordance with the IEC61400-1 and GL Regulations. The prototype blade was passed the structural proof test for GL certification.

  • PDF

An Experimental Study on the Fatigue Behavior of H & Channel-Type Lining Board (H형 복공판과 Channel형 복공판의 피로거동에 관한 실험적 연구)

  • Lee, Seung-Soo;Kim, Doo-Hwan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.9 no.4
    • /
    • pp.209-216
    • /
    • 2005
  • The objective of this paper is to investigate the H & Channel type lining board's capacity by using the fatigue test. The accumulated test result will be used to analyze the relation between the cause of crack occurrence and the behavior of structure. H type lining boards was comfortable behaved in over one million recycled. loading test. In case of channel type lining board specimens occurred the fatigue fracture in about one hundred thousand recycled loading test, and then could not secured endurance life that used servicing load.

Structural analysis of liquid rocket thrust chamber regenerative cooling channel using visco-plastic model (점소성 모델을 이용한 액체로켓 연소기 재생냉각 채널 구조해석)

  • Ryu Chul-Sung;Choi Hwan-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.151-155
    • /
    • 2006
  • Elastic-viscoplastic structural analysis is performed for regenerative cooling chamber of liquid rocket thrust chamber using Bodner-Partom visco-plastic model. Strain rate test was also conducted for a copper alloy at various temperatures in order to get material constants of visco-plastic model used in the structural analysis. Material constants of visco-plastic model were obtained from strain rate test results and visco-plsstic model was incorporated into finite element program, Marc, by means of user subroutine. The structural analysis results indicate that the deformation of cooling channel is mostly caused by thermal loading rather than pressure loading and confirmed structural stability of the cooling channel under operating condition.

  • PDF

Structural Design and Analysis of Sandwich Composite Structure for Floor Board Structure (샌드위치 복합재 바닥 구조물의 구조 설계 및 해석)

  • Park, Hyunbum
    • Journal of Aerospace System Engineering
    • /
    • v.11 no.6
    • /
    • pp.64-67
    • /
    • 2017
  • This work dealt with structural safety analysis about sandwich composite structure of automotive floor board. In this work, structural design and analysis of sandwich composite structure for automobile floor board were performed. Firstly, structural design requirement of automobile floor board was investigated. After structural design, the structural analysis of the automobile floor board were performed by the finite element analysis method. It was performed that the stress and displacement analysis at the applied load condition. After structural test of target structure, structural test results were compared with analysis results. Through the structural analysis, it was confirmed that the designed floor board structure is safety.

월성 3호기 격납건물 압력시험을 통한 구조건전성 평가

  • 백용락;이성규;이상국;신재철
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05b
    • /
    • pp.831-836
    • /
    • 1998
  • 원자로 격납건물은 그 기능적 중요성 때문에 건설종료후 반드시 원자로 가상사고를 가정한 조건에 대해 구조적 건전성을 입증하여야 한다. 본 논문은 이러한 요건에 따라 수행된 월성 3호기 원자로 격납건물 구조건전성 시험(SIT : Structural Integrity Test)의 개요와 결과를 분석한 것으로 시험결과 월성 3호기는 설계시 고려한 허용범위내에서 거동하였으며 사고시 압력하중이 큰 경수로형 원자로와 달리 시험기간중 외기 온도 변화에 민감한 변화를 보인 것으로 확인되었다. 아울러 시험결과의 정확한 평가를 위해서는 시험전 충분한 기간동안 온도변화가 계측되어야 하며, 계측기 출력의 안정화가 계측성과의 신뢰도를 높이는 필수인자임이 확인되었다.

  • PDF