• Title/Summary/Keyword: 구조설계해석

Search Result 5,396, Processing Time 0.037 seconds

Evaluation on the Compression Capacity of Transfer Slab Systems according to the Variation of Column Length (기둥의 길이변화에 따른 전이슬래브 시스템의 압축성능 평가)

  • Sim, Yeon-Ju;Choi, Chang-Sik
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.6
    • /
    • pp.695-702
    • /
    • 2016
  • This paper presents compression capacity of transfer system in pilotis subjected to axial load. Recently, transfer system is usually used in low floors of wall-typed apartments when members' sections are suddenly changed between upper walls and bottom columns. It can help transfer loads from the walls to the columns. Especially, a transfer girder system is usually used as one of transfer systems applied to a pilotis. However, the transfer girder system has low constructability and economics. Therefore, the other transfer system with transfer slab was suggested and has been studied. In this paper, to evaluate the compression capacity of transfer slab, tests were conducted on pilotis transfer slab systems subjected to axial load. First of all, two specimens were determined by FEM. The main parameter is length of the bottom columns. The lengh of the bottom columns were 40% and 50% of length of upper walls in the tranfer slab specimens. Results showed that the compression capacity of piloti transfer systems subjected to axial load was affected by length of bottom columns. The compression capacity is 52% higher than design strength for specimen with the bottom column's length of 40% of length of the upper wall and 46% for specimen with the bottom column's length of 50% of length of the upper wall.

Experimental Evaluation of Bi-directionally Unbonded Prestressed Concrete Panel Blast Resistance Behavior under Blast Loading Scenario (폭발하중 시나리오에 따른 2방향 비부착 프리스트레스트 콘크리트 패널부재의 폭발저항성능에 대한 실험적 거동 평가)

  • Choi, Ji-Hun;Choi, Seung-Jai;Cho, Chul-Min;Kim, Tae-Kyun;Kim, Jang-Ho Jay
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.6
    • /
    • pp.673-683
    • /
    • 2016
  • In recent years, frequent terror or military attack by explosion, impact, fire accidents have occurred. Particularly, World Trade Center collapse and US Department of Defense Pentagon attack on Sept. 11 of 2001. Also, nuclear power plant incident on Mar. 11 of 2011. These attacks and incidents were raised public concerns and anxiety of potential terrorist attacks on major infrastructures and structures. Therefore, the extreme loading researches were performed of prestressed concrete (PSC) member, which widely used for nuclear containment vessel and gas tank. In this paper, to evaluate the blast resistance capacity and its protective performance of bi-directional unbonded prestressed concrete member, blast tests were carried out on $1,400{\times}1,000{\times}300mm$ for reinforced concrete (RC), prestressed concrete without rebar (PSC), prestressed concrete with rebar (PSRC) specimens. The applied blast load was generated by the detonation of 55 lbs ANFO explosive charge at 1.0 m standoff distance. The data acquisitions not only included blast waves of incident pressure, reflected pressure, and impulse, but also included displacement, acceleration, and strains at steel, concrete, PS tendon. The results can be used as basic research references for related research areas, which include protective design and blast simulation under blast loading.

A Study on the Statistical GIS for Regional Analysis (지역분석을 위한 웹 기반 통계GIS 연구)

  • 박기호;이양원
    • Spatial Information Research
    • /
    • v.9 no.2
    • /
    • pp.239-261
    • /
    • 2001
  • A large suite of official statistical data sets has been compiled for geographical units under the national directives, and it is the quantitative regional analysis procedures that could add values to them. This paper reports our attempts at prototyping a statistical GIS which is capable of serving over the Web a variety of regional analysis routines as well as value-added statistics and maps. A pilot database of some major statistical data was ingested for the city of Seoul. The baseline subset of regional analysis methods of practical usage was selected and accommodated into the business logic of the target system, which ranges from descriptive statistics, regional structure/inequality measures, spatial ANOVA, spatial (auto) correlation to regression and residual analysis. The leading-edge information technologies including the application server were adopted in the system design and implementation so that the database, analysis modules and analytic mapping components may cooperate seamlessly behind the Web front-end. The prototyped system supports tables, maps, and files of downloadable format for input and output of the analyses. One of the most salient features of out proposed system is that both the database and analysis modules are extensible via the bi-directional interface for end users; The system provides users with operators and parsers for algebraic formulae such that the stored statistical variables may be transformed and combined into the newly-derived set of variables. This functionality eventually leads to on-the-fly fabrication of user-defined regional analysis algorithms. The stored dataset may also be temporarily augmented by user-uploaded dataset; The extension of this form, in essence, results in a virtual database which awaits for users commands as usual. An initial evaluation of the proposed system confirms that the issues involving the usage and dissemination of information can be addressed with success.

  • PDF

A Study on the Thermo-Mechanical Stress of MEMS Device Packages (마이크로 머신(MEMS) 소자 패키지의 열응력에 대한 연구)

  • Jeon, U-Seok;Baek, Gyeong-Uk
    • Korean Journal of Materials Research
    • /
    • v.8 no.8
    • /
    • pp.744-750
    • /
    • 1998
  • Unlike common device, MEMS(micro-electro-mechanical system) device consists of very small mechanical structures which determine the performance of the device. Because of its small mechanical structure inside. MEMS device is very sensitive to thermal stress caused by CTE(coefficient of thermal expansion) mismatch between its components. Therefore, its characteristics are affected by material properties. process temperature. and dimensions of each layer such as chip, adhesive and substrate. In this study. we investigated the change of the thermal stress in the chip attached to a substrate. With computer-aided finite element method (FEM), the computer simulation of the thermal stress was conducted on variables such as bonding material, process temperature, bonding layer thickness and die size. The commercial simulation program, ABAQUS ver5.6, was used. Subsequently 3-layer test samples were fabricated, and their degree of bending were measured by 3-D coordinate measuring machine. The experimental results were in good agreement with the simulation results. This study shows that the bonding layer could be the source of stress or act as the buffer layer for stress according to its elastic modulus and CTE. Solder adhesive layer was the source of stress due to its high elastic modulus, therefore high compressive stress was developed in the chip. And the maximum tensile stress was developed in the adhesive layer. On the other hand, polymer adhesive layer with low elastic modulus acted as buffer layer, and resulted in lower compressive stress. The maximum tensile stress was developed in the substrate.

  • PDF

Analysis on Pool Temperature Variation along Pool Water Management System Operation in Research Reactor (연구용원자로에서 수조수관리계통 운전에 따른 수조수 온도 해석)

  • Choi, Jungwoon;Lee, Sunil;Park, Ki-Jung;Seo, KyoungWoo
    • Transactions of the KSME C: Technology and Education
    • /
    • v.5 no.2
    • /
    • pp.135-143
    • /
    • 2017
  • The domestic unique research reactor, HANARO (Hi-flux Advanced Neutron Application ReactOr), has been constructed with the open-pool, the core is submerged in, for the multi-purpose neutron application. The reactor has a primary cooling system to remove the fission heat from the core and its connected fluidic systems. Since the works are required at the reactor pool top as a characteristic of the research reactor, the radiation shall be minimized with the operation of the hot water layer system to avoid unnecessary radiation exposure on the workers during work at the pool top. Moreover, the pool water management system is connected to the reactor pool to maintain the pool temperature below $50^{\circ}C$ to minimize the uprising radioactive gas or impurity from the colder pool bottom. For the efficient flow rate of the PWMS, the thermal capacity of heat exchanger is selected with 260 kW in the normal operation condition. In this paper, the modeling is formulated to figure out whether or not each pool temperature maintains below the temperature limit and the calculation results show that the designed PWMS heat exchanger has enough capacity with the design margin regardless of the reactor operation mode.

A Experimental Analysis on the Relationship between the Angle of a Locker and the Clamping Force of Wedge Type Rail Clamp (Locker의 물림각과 쐐기형 레일클램프의 압착력에 관한 실험적 고찰)

  • Han Dong-Seop;Shim Jae- Joon;Han Geun- Jo;Lee Kwon-Hee
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2005.10a
    • /
    • pp.247-252
    • /
    • 2005
  • The wedge type rail clamp has the operating mechanism: First, the jaw pad clamps a rail with small clamping force Next as the wind speed increases, the clamping force of the jaw pad is increased by the wedge. In order to design the wedge type rail clamp, we need to determine the proper wedge angle to minimize the sliding distance of a roller and the proper clamping angle of a locker to generate the initial clamping force of a jaw pad. The researches for the proper wedge angle have conducted, and in this study we conducted the investigation to determine the proper clamping angle of a locker in the rail clamp with wedge angle of $10^{\circ}$. Because the initial damping force of the jaw pad was determined by the clamping angle of the locker, in order to carry out the clamping force of a jaw pad, we measured the locking force applied to a locker with respect to the clamping angle of a locker, such as $3^{\circ},\;4^{\circ},\;5^{\circ},\;6^{\circ},\;$ using a pressure gauge, and compared the results with the FEA results.

  • PDF

A study on the correlation between the degree of elasticity uniformity and the dynamic performance in the overhead contact lines (전차선로 탄성도 불균일율과 동역학적 성능과의 관계에 대한 연구)

  • Park, Sa-Hoon;Kwon, Sam-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.502-502
    • /
    • 2007
  • A catenary system should be designed to have an uniform elasticity over a span in order to maintain the lowest possible loss of contact between a pantograph and a contact wire. A elasticity uniformity of a catenary can be regarded as a important design factor used for predicting the current collection performance for a catenary. There are a couple of formulas to calculate the degree of elasticity uniformity of a catenary according to the literature survey. The effectiveness of these formulas is reviewed by performing catenary elasticity and loss of contact analysis for various different configurations of catenary systems using a beam element based FEM program. The results reveals that these formulas are not suitable to predict the current collection performance for a catenary. Therefore, a new formula based on the standard deviation of the elasticity over a span is proposed in this study. The analysis results show that the new formula for an elasticity uniformity of a catenary is very effective in predicting the current collection performance for a catenary.

  • PDF

Elevation Water Stage Accuracy Analysis for Quality Improvement of Water Stage data (수위자료 품질향상을 위한 해발수위 정확도 분석)

  • Lee, Chung-Dae;Kim, Jeong-Yup;Chol, Hyuk-Joon;Kim, Chi-Young;Cho, Hyo-Seob
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.691-695
    • /
    • 2012
  • 수위표의 영점에서 수면까지의 높이로 정의되는 해발수위는 유량 및 유사량 등과 같은 관련 수문자료를 생산하는데 기본이 되는 자료이며, 하천 및 수공구조물의 설계 등에 기초자료로 이용될 뿐만 아니라 수자원의 효율적인 관리 및 수문순환 해석을 위한 가장 중요한 기초자료로서 국가 차원의 올바른 수자원 계획과 정책을 수립하는데 널리 활용된다. 이와 같이 해발수위자료의 이용 분야가 다양하고 그 자체로서도 중요한 의미를 가지는 점을 고려할 때 무엇보다도 중요한 것은 자료의 품질이 확보되어야 하는 것이다. 그러나 영점표고검정수준점 및 기준 수위표의 설치 이후 오랜 시간이 경과됨에 따라 노후화와 수위관측소 주변의 환경변화가 발생하게 되어 자료의 정확도가 매우 낮아지고 있다. 본 연구에서는 해발수위 자료의 품질향상을 위해 수위관측소의 영점표고검정수준점 및 수위표 영점표고에 대하여 수준측량 및 RTK(Real Time Kinematic) GPS(Global Positioning System) 측량을 병행하여 수행하였으며, 조사측량된 값을 활용하여 기존에 측량된 영점표고검정수준점 및 수위표 영점표고에 대한 검토를 수행하였다. 금강 및 삽교천 수계에 위치한 50개 수위관측소 대하여 기존 측량값과 비교 검토한 결과 영점표고검정수준점은 0.10m 이하(54.0%), 0.10m 초과 ~ 0.50m 이하(26.0%), 0.50m 초과 ~ 1.00m 이하(6.0%), 1.00m초과 ~ 1.50m 이하(2.0%), 1.50m 초과 ~ 2.00m 이하(2.0%), 2.00m 초과 ~ 3.00m 이하(4.0%), 3.00m 초과(6.0%)의 값을 나타냈으며, 수위표 영점표고는 0.10m 이하(50.0%), 0.10m 초과 ~ 0.50m 이하(32.0%), 0.50m 초과 ~ 1.00m 이하(10.0%), 1.00m초과 ~ 1.50m 이하(2.0%), 1.50m 초과 ~ 2.00m 이하(2.0%), 2.00m 초과 ~ 3.00m 이하(2.0%), 3.00m 초과(2.0%)의 값을 가졌다. 이와 같이 기존과 금회 측량자료를 비교 검토한 결과 대부분이 안정적으로 유지되고 있으나 일부 수위관측소에서 변동량이 크게 발생한 원인은 영점표고검정수준점의 노후화, 기준 수위표의 교체 및 위치 변동, 인위적인 하천공사 등으로 인하여 발생한 것으로 판단된다.

  • PDF

Shear Behavior of Rough Granite Joints Under CNS Conditions (일정 수직강성 조건하 화강암 인장절리의 전단거동 특성)

  • Park, Byung-Ki;Lee, Chang-Soo;Jeon, Seok-Won
    • Tunnel and Underground Space
    • /
    • v.17 no.3 s.68
    • /
    • pp.203-215
    • /
    • 2007
  • Stability and mechanical deformation behavior of rock masses are highly dependent on the mechanical characteristics of contained discontinuities. Therefore, mechanical characteristics of the discontinuities should be considered in the design of tunnel and underground structures. In this study, direct shear tests for rough granite joints were carried out under constant normal stiffness conditions. Effects of initial normal stress, shear velocity, and surface roughness on the characteristics of shear strength and deformation behaviors were examined. Results of shear testing under constant normal stiffness conditions reveal that shear behaviors could be classified into two categories, based on the amount of decrease in shear stress at the Int peak shear stress. With initial normal stiffness increasing, it turned out that shear displacement at peak stress and the first peak shear stress increased, however friction angle and friction coefficient showed decrease. In case of shear stiffness and average friction coefficient, it turned out that they are not dependent on the initial normal stress. Minor effects of shear velocity on rough joints were observed in several shear quantities. However, the effects of shear velocity were insignificant regardless of the normal stress increase. Change of shear strength and deformation characteristics on joint roughness were examined, however, it turned out that the variations were attributed to deviation of shear test specimens.

Discharging Performance in Length of Hard Labyrinth and Pressure of Cylinder Type Drip Irrigation Hose (원통형 점적기의 압력과 경질미로의 길이에 따른 토출 특성)

  • Kim, Jin Hyun;Woo, Man Ho;Kim, Dong Eok
    • Journal of agriculture & life science
    • /
    • v.52 no.6
    • /
    • pp.103-109
    • /
    • 2018
  • The performance of drip irrigation devices depends on flow uniformity related to the function of pressure compensation. The flow uniformity can be secured when the internal fluid pressures at the positions of the flow holes are maintained uniformly. The pressure compensation effect of the drip irrigation devices can be optimized with the combination of soft silicon and labyrinth structures. However, for a drip irrigation devices composed of only hard labyrinth structures, the flow rate is changed largely with the length and the internal geometry of the labyrinth structure. Although a drip irrigation devices with only hard labyrinth structures can be fabricated simply, the changes of flow rates with internal fluid pressures are much larger than those of the drip irrigation devices with soft silicon. Because the drip irrigation devices with only labyrinth structures can be utilized widely through the optimization of the fluid pressure, the length of the structures, and the cross-sectional area of them, the study on the optimization can play an important role for enhancing the performance of the drip irrigation devices. In this study, experimental and numerical studies for investigating the performance of the drip irrigation devices had been conducted. In the experiments and numerical calculations(CFD), the variable parameters were the lengths of the labyrinth structures(#1~#8) and the fluid pressures(0.5~3.0 bar).