• Title/Summary/Keyword: 구조벽체

Search Result 587, Processing Time 0.023 seconds

Evanescent-mode Waveguide Band-pass Filter Applied by Novel Metal Post Capacitor (새로운 금속막대 커패시터를 적용한 감쇄모드 도파관 대역통과 여파기)

  • Kim, Byung-Mun;Yun, Li-Ho;Lee, Sang-Min;Hong, Jae-Pyo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.5
    • /
    • pp.775-782
    • /
    • 2022
  • In this paper, a novel small-diameter cylindrical post capacitor inserted into an evanescent-mode rectangular waveguide (EMRWG) is proposed for easier tuning. In order to feed the EMRWG, the proposed structure uses a single ridge rectangular waveguide with the same width and height as the waveguide at the input and output ends. The inserted post capacitor are made up a circular groove formed in the center of the lower part of the broad wall of the EMRWG, and a concentric cylindrical post inserted into the upper part. First, the equivalent circuit model for the proposed structure is presented. When the EMRWG and the single ridge waveguide are combined, the joint susceptance and the turns ratio of the ideal transformer are calculated by two simulations using HFSS (3d fullwave simulator, Ansoft Co.) respectively. The susceptance and resonance characteristics of the inserted post were analyzed by using the obtained parameters and the characteristics of the EMRWG. A 2-post filter with a center frequency of 4.5 GHz and a bandwidth of 170 MHz was designed using a WR-90 waveguide, and the simulation results by using the HFSS and CST, equivalent circuit model were in good agreement.

Analysis of effect of hydrogen jet fire on tunnel structure (수소 제트화염이 터널 구조체에 미치는 영향 분석)

  • Park, Jinouk;Yoo, Yongho;Kim, Whiseong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.23 no.6
    • /
    • pp.535-547
    • /
    • 2021
  • A policy to expand the hydrogen economy has been established in Korea and the supply of FCEV is being expanded to realize a hydrogen society. Therefore, the supply of FCEV is expected to increase rapidly, and a solution to respond to accidents of FCEV is required. In this study, an experimental study was conducted to analyze the effect of the hydrogen jet flame generated by a FCEV on the inner wall of the tunnel and the characteristics of the internal radiant heat. For the experiment, the initial pressure of hydrogen tank was set to 700 bar, and the injection nozzle diameter was set to 1.8 mm in order to make the same as the conditions generated in the FCEV. In addition, a tunnel fire resistance test specimen having the same strength as the compressive strength of concrete applied to general tunnels of 40 MPa was manufactured and used in the experiment. The results were analyzed for the separation distance (2 m and 4 m) between the hydrogen release nozzle and the tunnel fire resistance test concrete. As the result, the maximum internal temperature of the test concrete was measured to 1,349.9℃ (2 m separation distance), and the radiant heat around the jet flame was up to 39.16 kW/m2.

A Study on the Development of Construction Production Rates System for Estimating Proper Construction Expenses of Off-Site Construction (OSC) Based PC Structure Factory-Built Assembly (OSC기반 PC구조 공장제작 적정 공사비 산정을 위한 품셈체계 개발 연구)

  • Lee, Jeongwook;Lee, Hansoo;Lee, Chiho;Noh, Hyunseok
    • Korean Journal of Construction Engineering and Management
    • /
    • v.23 no.6
    • /
    • pp.89-100
    • /
    • 2022
  • The development of the Construction Production Rates System for appropriate construction cost calculation has recently come to the fore as a means of invigorating OSC based PC structure which currently needs institutional frameworks. PC structure based construction expenses consist of the factory-built assembly, transportation and on-site installation. Recently, in the field of transportation and site installation, research on product structure development is being conducted, such as presenting the standard product calculation system reflecting the results of field survey for each subsidiary materials (Lee et al., 2021). On the other hand, there is no ongoing research on estimating construction expenses of Factory-built assembly. This study suggests Construction Production Rates System which can be used for PC subsidiary materials based Factory-built assembly cost estimations. For the research, work types for the construction procedures have been categorized, and the standard input manpower suitable for the corresponding work characteristics has been derived from analyzing the associated Construction Standard Production Rates for each work type. Also, as the research referred PC subsidiary materials (such as columns, beams, walls, and slab, as well as on-site installation) and the standard number of workforce based on work types, one can calculate direct labor cost, using what the research shows. In addition, it suggests that the size of individual subsidiary materials be the extra cost factor, by using the characteristics that productivity changes depending on the size(m3) of subsidiary materials. It is expected that the research can contribute to objectively verifying factory-built assembly cost through of PC structure, which currently relies on estimates.

A Study on Structural Maintenance of 'Old Wall' Designated as National Registered Cultural Heritage (국가등록문화재로 지정된 옛 담장의 정비 양상)

  • So, Hyun-Su;Jeong, Myeong-Seok
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.41 no.1
    • /
    • pp.21-34
    • /
    • 2023
  • This study identified the materials and construction methods of 'Old Wall' in 13 villages which were designated as National Registered Cultural Heritage at the time of designation and examined the their structural changes based on field survey. The results are as follows: First, the 'Old Wall' consisted of 10 Soil-Stone Wall and 5 Stone Wall. At the time of designation, Stone Wall, which was built irregularly by dry-construction of natural stones, is similar in shape, but Soil-Stone Wall showed difference by the construction method of making used stones, joints, and faces. Second, the study extracted the changes of 'Old Wall' by repair and examined the changes of construction methods as well as the substitution and addition of materials of structure. The wall-roof was built with cement roof-tile and asbestos slate which have the advantage improve durability and cost-effectiveness. In addition, tile-mouth soil was added to korean traditional roof-tile to prevent rainwater from flowing in. Besides, to improve constructional convenience, the natural stone of the wall-body was replaced with blast stone, float stone and cut stone. Cement block, cement brick and cement mortar were frequently used to repair as well. As Soil-Stone Wall was transformed from irregular pattern-construction to comb pattern-construction and wet-construction was changed to dry-construction, it caused landscape and structural problems. Also, the layer of cement mortar applied to wall-foundation blocked the flow of rainwater that was induced by dry-construction of natural stones. Third, the study regarded that the problem with the repair of 'Old Wall' may occur as it is located in living space, because the owner of the wall could repair for the minor damages without technical knowledge. In addition, it is difficult for repair companies in charge of maintenance of Cultural Heritage to supply local materials, and it is differential construction specifications are not applied.

Evaluation of Local Effect Prediction Formulas for RC Slabs Subjected to Impact Loading (충격하중이 작용하는 RC 슬래브의 국부손상 산정식에 대한 고찰)

  • Chung, Chul-Hun;Choi, Hyun;Lee, Jung Whee;Choi, Kang Ryong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.6A
    • /
    • pp.543-560
    • /
    • 2010
  • Safety-related concrete structures in a nuclear power plant must be protected against the impact of flying objects, referred to in the profession as missiles. In practice, the structural verification is usually carried out by means of empirical formulas, which relate the velocity of the impinging missile to the wall thickness needed to prevent scabbing or perforation. The purpose of this study is to reevaluate the predictability of the local effect prediction formulas for the penetration and scabbing depths and perforation thickness. Therefore, available formulas for predicting the penetration depth, scabbing thickness, and perforation thickness of concrete structures impacted by solid missiles are summarized, reviewed, and compared. A series of impact analyses is performed to predict the local effects of the projectile at impact velocities varing from 95 to 215 m/s. The results obtained from the numerical simulations have been compared with tests that were carried out at Kojima to validate numerical modelling. The simulation results show reasonable agreement with the Kojima test results for the overall impact response of the RC slabs. From these results, it seems that the Degen equation give a very good estimate of perforation thickness against a tornado projectile for test data. Finally, the results obtained from the impact analysis have been compared with Degen formula to determine the perforation thickness of the RC slab.

Numerical Analysis of Wave Transformation of Bore in 2-Dimensional Water Channel and Resultant Wave Loads Acting on 2-Dimensional Vertical Structure (2차원수조내에서 단파의 변형과 구조물에 작용하는 단파파력에 관한 수치해석)

  • Lee, Kwang Ho;Kim, Chang Hoon;Kim, Do Sam;Hwang, Young Tae
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.5B
    • /
    • pp.473-482
    • /
    • 2009
  • This study numerically discusses wave forces acting on a vertical wall such as breakwaters or revetments, subjected to incident undular or turbulent bores. Due to the complex hydrodynamics of bore, its wave forces have been predicted, mainly through laboratory experiments. Numerical simulations in this paper were carried out by CADMAS-SURF(CDIT, 2001), which is based on Navier-Stokes momentum equations and VOF method (Hirt and Nichols, 1981) for tracking free water surface. Its original source code was also partly revised to generate bore in the numerical water channel. Numerical raw data computed by CADMAS-SURF included great strong spike phenomena that show the abrupt jumps of wave loads. To resolve this undesired noise of raw data, the band-pass filter with the frequency of 5Hz was utilized. The filtered results showed reasonable agreements with the experimental results performed by Matsutomi (1991) and Ramsden (1996). It was confirmed that CADMASSURF can be applied to the design of coastal structures against tsunami bores. In addition, the transformation process and propagation speed of bores in the same 2-d water channel were discussed by the variations of water level for time and space. The numerical results indicated that the propagation speed of bore was changed due to the nonlinear interactions between negative and reflected waves.

Development of Solar Warehouse for Drying and Storing the Agricultural Products (농산물(農産物) 건조(乾燥) 및 저장(貯藏)을 위(爲)한 태양열(太陽熱) 저장고(貯藏庫)의 개발(開發)에 관(關)한 연구(硏究))

  • Kim, Man Soo;Chang, Kyu Seob;Kim, Soung Rai;Jeon, Byeong Seon
    • Korean Journal of Agricultural Science
    • /
    • v.9 no.1
    • /
    • pp.357-370
    • /
    • 1982
  • Recent concern regarding price and availability of fossil fuels has spurred the interest in alternative sources for farm crop drying. Among the available options such as biomass energy, wind power, nuclear energy and solar energy etc., the increasing attention is being directed to the utilization of heat from solar energy especially for farm crop drying. Even though solar energy is dispersed over a large land area and only a relatively small amount of energy can be simply collected, the advantages of solar energy is that the energy is free, non-polluting. The study reported here was designed to help supply the informations for the development of simple and relatively inexpensive solar warehouse for farm crop drying and storage. Specifically, the objectives of this study were to determine the performance of the solar collector fabricated, to compare solar supplemented heat drying with natural air drying and to develop a simulation model of temperature in stored grain, which can be used to study the effects due to changes in ambient air temperature. For those above objectives, solar collector was fabricated from available materials. Corrugated steel galvanized sheet, painted flat black, was used as absorbers and clear 0.2mm polyethylene sheet was the cover material. The warehouse for rough rice drying and storage was constructed with concrete block, and the solar collector was used as the roof of warehouse instead of original roofing system of it. The results obtained in this study were as follows: 1. The thermal efficiency of the solar collector was average 26 percent and the overall heat transfer coefficient of the collector was approximately $25kJ/hr.m^2\;^{\circ}K$. 2. Solar heated air was sufficient to dry one cubic meter of rough rice from 23.5 to 15.0 percent in 7 days and natural air was able to dry the same amount of rough rice from 20.0 to 5 percent in l2 days. 3. Drying with solar heat reduced the required drying time to dry the same amount of rough rice into a half compared to natural air drying, but overdrying problems of the bottom layer were so severe that these problems should be thoroughly analyzed. 4. Simulation model of temperature in stored grain was developed and the results of predicted temperature agreed well with test results. 5. Based on those simulated temperature, changes in the grain-temperature were a large at the points of the wallside and the damage of the grain would be severe at the contact area of wall.

  • PDF

The Investigation and Conservation of Central Asia Wall Painting (No. 4074 and 4096) (중앙(中央) 아세아(亞細亞) 벽화(壁畵) 보존처리(保存處理)(I) - 벽화(壁畵)(본(本)4074, 본(本)4096)의 상웅조사(狀熊調査) -)

  • Kang, Hyung-tae;Yi, Yong-hee;Yu, Hei-sun;Kim, Yeon-mi;Jo, Yeon-tae;Aoki, Shigo;Yamamoto, Noriko;Ohbayashi, Kentaro
    • Conservation Science in Museum
    • /
    • v.3
    • /
    • pp.43-50
    • /
    • 2001
  • This article is about a joint project carried out by the National Museum of Korea and the Tokyo Cultural Properties Research Institute for the conservation of central Asia Wall painting that has been selected for the exhibition at the new Seoul National Museum of Korea at Yongsan. The investigation of the wall painting revealed very useful information. This includes the condition of the object, and the identification of evident damage, such as cracks, loss of pigment, plus materials and methods employed during the object's creation, as well as previous conservation treatment. The object was mainly made by applying plaster to the body (wall) that consisted of a mixture of soils and rice straws. Then, on the surface of the wall-painting, pigments were used to draw and to colour it. As a part of the investigation, radiocarbon dating was conducted using straw samples taken from the object. The result indicates that the object is probably dated form between the end of the 10th Century and the beginning of the 13th Century. The result of X-ray diffraction also revealed the composition of the pigments used on the surface. These are 1. gypsom [Ca(SO4)·2H2O], CaSO4 and Calcite (CaCO3) and Calcite (CaCO3) that were used for the white background. 2. Pb3O4 and led Arsenate [Pb(As2O6) that were used for the red colouring. 3. Cuprite (Cu2O), Arsenolite (As2O3) and Arsenic Oxide (As2O4) that were used for the green colouring.

The Study on the Wave Pressure of the Tsunami Acting on the Permeable Structure (투과성구조물에 작용하는 지진해일파압에 관한 연구)

  • Lee, Kwang-Ho;Choi, Hyun-Seok;Kim, Chang-Hoon;Kim, Do-Sam;Cho, Sung
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.23 no.1
    • /
    • pp.79-92
    • /
    • 2011
  • In this study, wave pressure of short-period gravity waves and tsunami acting on the upright section of the horizontal-slit type caisson placed on the impermeable or permeable seabed, which is a well-known permeable breakwater with a good wave controlling ability, are investigated via numerical simulations. Further, the permeable seabed was modeled as the porous media with porosity of 0.4. Using the numerical results, the effects of the seabed conditions on the wave pressure on the front wall and inside wall of the chamber have been studied. In the numerical simulations, short-period gravity waves and tsunami(solitary wave or bore) with the same amplitude to the gravity wave are considered. A numerical wave tank is used, which is able to consider a gas-liquid two-phase flow in the same calculation zone. Numerical results show that the wave pressure of the tsunami was 3~5 times higher than the short-period gravity waves acting on the front wall and it was 2~4 times higher than the short-period gravity waves acting on the inner wall.

Analysis & Design Electronic Commerce System Interface for The Blind (시각장애 사용자를 위한 전자상거래 인터페이스 분석 및 설계)

  • 박성제;강영무
    • Proceedings of the Korea Association of Information Systems Conference
    • /
    • 2001.12a
    • /
    • pp.413-426
    • /
    • 2001
  • 본 연구는 첫째, 정보통신기술의 발달이 시각장애인 복지 증진에 미칠 수 있는 가능성에 대한 이론적인 부분을 고찰하였다. 둘째, 우리나라 시각장애인 정보화의 문제점과 해결책을 도출하였고 셋째, 시각장애 사용자를 위한 전자상거래 인터페이스 디자인의 분석 및 설계를 통해 전자상거래에서 시각장애 사용자들이 큰 제약없이 사용할 수 있는 방안을 제시하고자 한다. 현재 시각장애인들의 웹 사용을 보면 시각장애 전용 S/W의 보조 하에 사용을 하고 있다. 그러한 보조 도구의 실정에 맞도록 텍스트 버전 및 Non-Frame버전, Alt-Text 옵션, 캡션 등을 넣어 접근성을 확보하고 인터넷을 큰 제약을 받지않고 이용할 수 있도록 웹 페이지의 설계가 필요한 실정이다. 이를 위하여 먼저 시각장애에 대한 개념과 원인 및 종류 그리고 특성을 통해 시각장애인에 대한 이론적 배경을 파악하였다. 그리고 시각장애인의 정보화 환경과 이용 현황과 시각장애인의 정보 접근을 제도적, 기기 및 소프트웨어 개발 측면에서 분석을 하였고, 장애인을 위한 정보통신기술 중 대표적인 사례를 검토해 보았다. 다음으로 국내외의 대표적인 전자상거래 사이트에서의 인터페이스를 화면구성(Layout), 텍스트(Text), 그래픽(Graphic), 멀티미디어(MultiMedia) 측면에서 분석을 하였다. 분석한 내용을 바탕으로 시각장애 사용자의 입력(User Input) 부분을 고려한 인터페이스 방향을 제시하고 프로토타입을 개발하여 시험 대상 사이트와의 만족도를 시각장애 사용자를 통해 비교 ·분석하였다. 결론부분에서는 정보불평등을 해소하고, 정보통신기술이 장애인의 복지향상에 기여하도록 하기 위해 전자상거래 싸이트에서의 시각 장애인들을 위한 방향을 제시하고자 한다.박의 표현, 등록 및 색인방법 (c) 공급 선박의 분류와 표현 방법 (d) 에이전트의 정보 수집을 위한 메시지 표현 방법 (e) 수집된 선박정보의 데이터베이스 저장 표현방법 (f) 요구 선박을 찾아주는 정보제공 서비스가 요구된다.동을 보여 조사대상 5호분, 6호분, 7호분, 중 가장 심한 거동을 보이고 있다. 이는 고분 벽돌의 깨짐이 6호분이 가장 심하다는 사실과 무관하지 않은 것으로 판단된다. 봉분내부의 토양층구조에 대한 지오레이다 영상단면을 분석한 결과 무령왕릉 연도상부의 누수지방지층이 심하게 균열되어 있음을 발견하였다. 이 곳은 고분내부로 직접누수가 발생하는 곳이다. 직접누수와 지하수 형태로 유입된 침투수는 고분군 주위의 지반의 함수비를 증가시켜 지반의 지지력을 약화시키고 또한 고분내로 서서히 유입되어 고분내부의 습도를 100%로 유지시키는 주된 원인이다. 이러한 높은 습도는 고분내의 남조류의 번식을 가져왔으며 남조류의 번식은 현재 6호분이 가장 심각하고 7호분이 우려되는 수준이며 5호분은 문제가 없는 것으로 판단된다. 이와 같이 고분군의 발굴후 인위적인 환경변화와 지속적인 강우침투 및 배수 불량의 영향은 고분군의 안정성에 상당한 위험을 초래하였으며, 현 상태는 각 고분에 대한 보강이 불가피한 것으로 판단된다. 고분 벽돌의 깨짐, 고분 벽체의 거동, 조류의 서식등을 포함하여 송산리 고분군에서 발생되고 있는 보존상의 제반 문제점들을 일차적으로 누수 및 침투수에 의한 결과이다. 그러므로 무엇보다도 고분군 내부 및 고분 주변으로의 강우 및 지하수 침투를 막는 차수 대책이 시급한 것으로 판단된다. 또한 이미 발생한 변위가 더 이상 진행되지 않도록 하중을 경감하고 토압의 균형을 이루는 보강대책이 시급한 실정이다. 고분군

  • PDF