• Title/Summary/Keyword: 구조물의 에너지

Search Result 1,485, Processing Time 0.03 seconds

Structural Intensity Analysis of Local Ship Structures Using Finite Element Method (유한요소법을 이용한 선체 국부 구조물의 진동인텐시티 해석)

  • Dong-Hwan Lee;Dae-Seung Cho
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.38 no.3
    • /
    • pp.62-73
    • /
    • 2001
  • The interest in evaluation of structural intensity arises for practical reasons, because net energy flow distribution offers information of energy transmission path, positions of sources, and sinks of vibration energy. In this paper, structural intensity analysis of local ship structures using finite element method(FEM) is carried out. The purpose of this analysis is to evaluate the relative accuracy according to mesh fineness. The structural intensity of unstiffened and stiffened plates varying their mesh fineness is analyzed and the results are compared with those obtained by the assumed mode method. As results, the proper mesh size in qualitative/quantitative structural intensity analysis of plate structures is proposed. In addition, the propagation phenomenon of vibration energy is investigated for the thickness-varying flat plate, L-type plate, and box-girder structures.

  • PDF

Comparison of Energy Demand in Multi-Story Buckling Restrained Braced Frame and Equivalent SDOF System (다층 비좌굴 가새골조와 등가 단자유도계의 에너지 요구량의 비교)

  • 김진구;원영섭
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.16 no.2
    • /
    • pp.173-182
    • /
    • 2003
  • In equivalent static nonlinear analysis and in energy-based design, the structures are generally transformed into an equivalent SDOF system. In this study the seismic energy demands in multi story structures, such as three-, eight-, and twenty-story steel moment-resisting frames(MRF), buckling restrained braced frames(BRBF) and a damage tolerant braced frame(DTBF), are compared with those of equivalent single degree of freedom(ESDOF) systems. Sixty earthquake ground motions recorded In different soil conditions, which are soft rock, soft soil, and neat fault, were used to compute the input and hysteretic energy demands in model structures. In case the modal mass coefficient is less than 0.8, the effects of higher modes are considered in the process of converting into ESDOF According to the analysis results, the hysteretic and input energies obtained from 3 story and 8 story MRF and DTBF agreed well with the results from analysis of equivalent SDOF systems. However in the 20 story BRBF the results from ESDOF underestimated those obtained from the original structures.

Investigation of Gas Hydrate Crystallization and Structure Analysis by $^{13}C$ NMR with Surfactant (계면활성제 첨가에 따른 가스하이드레이트 생성 결정과 $^{13}C$ NMR 구조 분석 고찰)

  • Cho, Byoung-Hak;Lee, Young-Chul;Shin, Myung-Uk;Lee, Sung-Han
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.395-398
    • /
    • 2006
  • 동일한 조건에서 순수한 물과 계면활성제인 DBS(dodecyl bezebe sulfonic acid) 25ppm을 첨가한 물에 대해 천연가스 하이드레이트를 제조시 가스의 함유량은 각각 80배와 160배로 2배의 차이가 발생한다. 이에 대해 본 연구에서는 결정 생성 형태의 관찰 및 $^{13}C$ NMR을 사용한 분광학적 구조 분석으로부터 이의 원인을 찾고자 하였다. 순수한 물과 DBS를 미량 함유한 물을 사용하여 whiskery 결정을 생성시킨 결과, 순수한 물을 사용한 경우보다 섬유 다발 형태가 매우 활발한 형태의 결정 형태로 가스하이드 레이트가 생성됨을 알 수 있었다. 또한 400MHz의 NMR을 사용한 분광학적 구조 분석으로부터 천연가스하이드레이트는 구조-I과 구조-II가 혼재된 결정 구조를 이루고 있음을 알 수 있었다. 또한 DBS를 함유한 물에 의해 제조된 천연가스하이드레이트는 arge cage를 많이 생성시키는 역할을 하는 분석 결과를 보였고 이것이 가스 함유량을 증대시키는 원인 중의 하나임을 알 수 있었다.

  • PDF

Seismic Energy Response of Steel Moment Resisting Frames with Mass Irregularity (질량비정형을 갖는 강 모멘트 저항 골조의 지진에너지 반응)

  • Choi, Byong-Jeong;Song, In-Hawn
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.09a
    • /
    • pp.213-220
    • /
    • 2003
  • 고층의 강 모멘트저항골조에 대한 지진 반응을 살펴보기 위해서 동적해석을 실시하였다. 구조물은 세가지의 다른 설계절차로 의도적으로 설계하였고 그 세가지의 개념은 강도 지배설계, 강기둥-약보 지배설계, 횡변위 지배설계이다. 그렇게 설계한 구조물이 각각 질량비정형이 존재하도록 하여 힁변위, 소성힌지, 이력에너지 입력 및 요구응력에 대해서 토론하였다. 미래에 설계에의 응용을 위해서 최대 지반가속도로 표현한 두 등급의 지진 하중을 이용해서 이력에너지 입력요구 곡선을 제시하였다.

  • PDF

Analysis of a Non-proportionally Damped Structure Equipped with Viscoelastic Dampers Subjected to Stationary Wind Loads (점탄성감쇠기를 설치한 비비례 감쇠 구조물의 풍응답 해석)

  • 김진구;이창용
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.12 no.4
    • /
    • pp.649-659
    • /
    • 1999
  • 본 연구에서는 점탄성감쇠기가 설치된 비비례 감쇠 구조물의 바람에 대한 확률적 응답을 진동수영역에서 구하였다. 복소수 고유치 및 고유백터를 바탕으로 모드중첩법을 이용하여 응답의 RMS 값을 구하고 그것을 근사적인 방법인 모드 변형에너지법에서 얻은 결과와 비교하였다. 또한, 가력 진동수에 따라서 변하는 점탄성감쇠기의 강성 및 감쇠 계수를 상수로 모형화하였을 때의 풍응답 해석 결과의 정확성을 진동수영역에서 검증하였다. 해석결과에 의하면 감쇠기의 진동수 의존 특성은 구조물의 1차 고유 진동수에 의해서 비교적 정확하게 표현되었고, 모드 변형에너지법은 대체로 정확한 결과를 도출하였지만, 가속도 응답을 구할 때에는 다소 큰 오차를 유발하였다.

  • PDF

Prediction of Wave Energy Absorption Efficiency and Wave Loads of a Three-Dimensional Bottom-Mounted OWC Wave Power Device (착저식 OWC 파력발전장치의 파에너지 흡수효율 및 파랑하중 계산)

  • Hong, Do-Chun;Hong, Key-Yong
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.13 no.1
    • /
    • pp.47-52
    • /
    • 2010
  • The wave energy absorption efficiency and the first-order and the time-mean second-order wave loads of a three-dimensional bottom-mounted oscillating water column (OWC) chamber structure are studied. The potential problem is solved by making use of a hybrid Green integral equation associated with the finite-waterdepth free-surface Green function outside a twin chamber and the Rankine Green function inside taking account of the fluctuating air pressure inside the chamber. Numerical results of the primary wave energy converting efficiency and the oscillating and steady wave loads of a three-dimensional bottom-mounted OWC pilot plant have been presented.

Application Technique to Piezoelectric Smart Structures of Statistical Energy Analysis (압전 지능 구조물의 통계적 에너지 해석 기법 적용에 관한 연구)

  • Kim Jung Ha;Kim Jae Hwan
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.415-420
    • /
    • 1999
  • 본 연구의 목적은 SEA모델링 기법을 이용하여 시스템 응답 특성을 예측 하는데 있어서 연견 손실 계수(coupling loss factor). 내부 손실 계수(internal loss factor)와 같은 주요 변수의 값을 압전 지능 구조물을 이용하여 도출 하는 .것이다. 관심 주파수 대역에서 임피던스(impedance) 해석기를 이용해 압전 지능 구조물의 임피던스를 측정하고 랜덤 가진 시 압전 지능 구조물의 부하전압을 측정, 시스템에 가해지는 전기적 파워를 구하였다. 이 값을 전기-기계적 연결 계수(electro-mechanical coupling coefficient)를 이용 기계적 파워로 상사 시키고 이때 시스템에 저장되는 에너지를 가속도계를 이용해 측정 하였다. 이 결과 값을 이용하여 연결 손실 계수와 내부 손실 계수를 구하여 보았다. 또한 이론식을 이용하여 얻은 이론 값과 기존의 가진기(shaker)를 이용하여 얻은 실험 값과 비교 분석 하였다.

  • PDF

Inelastic Energy Absorption Factor for the Seismic Probabilistic Risk Assessment of NPP Containment Structure (확률론적 지진위험도 분석을 위한 원전 격납건물의 비탄성에너지 흡수계수 평가)

  • 최인길;서정문
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.5 no.5
    • /
    • pp.47-56
    • /
    • 2001
  • In order to assure the safety of NPP structures, margin of safety or conservatism is incorporated in each design step. Seismic risk evaluation of NPP structures is performed based on the realistic capacity and response of structure eliminated the safety margin and conservatism. In this study, the comparative study on the various evaluation methods of the inelastic energy absorption capacity was performed. The inelastic energy absorption capacity due to the nonlinear behavior of structures has significant effect on the results of seismic probabilistic risk assessment. And the comparison study of the HCLPF(high confidence of low probability of failure) values according to the inelastic energy absorption factors was performed. As a conclusion, the inelastic energy absorption factor of NPP containment structure is estimated about 1.5~1.75. It is essential to estimate the nonlinear behavior of structure and its ductility factor correctly for the seismic risk assessment.

  • PDF

Temperature-dependent Diffusion Coefficient of Chloride Ion in UAE Concrete (UAE 콘크리트에 대한 염화물 확산의 온도의존성)

  • Ji-Won Hwang;Seung-Jun Kwon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.28 no.4
    • /
    • pp.48-54
    • /
    • 2024
  • NPP (Nuclear power plant) structures have been constructed near to the sea shore line for cooling water and exposed to steel corrosion due to chloride attack. Regarding NPP structures built in the UAE, chloride transport may be more rapid than those in the other regions since the temperature near to the coast is high. In this study, concrete samples with 5,000psi (35MPa) design strength grade were manufactured with the materials and mix proportions, which were the same as used in the UAE NPP structures, then chloride diffusion coefficients were evaluated considering temperature and curing age. The compressive strength and the diffusion coefficient were evaluated and analyzed for the samples with 28 and 91 curing days. In addition, chloride diffusion tests for 91-day-cured condition were carried out in the range of 20℃ to 50℃. The activation energy was obtained through converting the temperature slope to a logarithmic function and it was compared with the previous studies. The proposed activation energy can be useful for a reasonable durability design by using actual temperature-dependent chloride diffusion coefficient.

Nondestructive Damage Identification in a Truss Structure Using Time Domain Responses (시간영역의 응답을 사용한 트러스 구조물의 비파괴 손상평가)

  • Choi, Sang-Hyun;Park, Soo-Yong
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.7 no.4
    • /
    • pp.89-95
    • /
    • 2003
  • In this paper, an algorithm to locate and size damage in a complex truss structure using the time domain response is presented. Sampled response data for specific time interval is spatially expanded over the structure to obtain the mean train energy for each element of the structure. The mean strain energy for each element is, in turn, used to build a damage index that represents the ratio of the stiffness parameter of the pre-damaged to the post-damaged structure. The validity of the methodology is demonstrated using data from a numerical example of a space truss structure with simulated damage. Also in the example, the effects of noisy data on the proposed algorithm are examined by adding random noised to the response data.