• Title/Summary/Keyword: 교환전류밀도

Search Result 27, Processing Time 0.019 seconds

Effect of Current Density and pH of Electrolyte on Anion-Exchange Membrane Fouling (전류밀도와 전해질의 pH가 음이온교환막의 막 오염에 미치는 영향)

  • Choi, Jae-Hwan
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.9
    • /
    • pp.965-969
    • /
    • 2005
  • Current density is an important operating parameter in the ion-exchange membrane process. We observed the effects of fouling of a Neosepta AMX anion-exchange membrane(Tokuyama Soda, Japan) in 0.02 M NaCl solution containing 100 mg/L sodium humate. Membrane fouling was analyzed by measuring the change in the electrical resistance in the under- and over-limiting current density regions. The experimental results found that membrane fouling was negligible at under-limiting current densities, but was increased significantly when an over-limiting current was supplied. After the fouling experiments, the current-voltage curves for the fouled membranes were measured. From the curves, we observed increased electric resistance and reduced limiting current density(LCD), caused by the accumulation of humic acid on the membrane surface. Furthermore, membrane fouling increased as the acidity of the electrolyte solution containing humic acid increased. This occurred because the fouling of an anion-exchange membrane is affected more by the physicochemical properties of the humic substance than by the surface charge of the humate.

Analysis of Current-Voltage Characteristics Caused by Electron Injection in Metal-Oxide-Semiconductor Devices (전자주입에 의해 야기되는 MOS 소자의 전류-전압 특성 분석)

  • Jeon Hyun-Goo;Choi, Sung-Woo;Ahn, Byung-Chul;Roh, Yong-Han
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.11
    • /
    • pp.25-35
    • /
    • 2000
  • A simple two-terminal cyclic current0voltage(I-V) technique was used to measure the current-transients in metal-oxide-semiconductor capacitors. Distinct charging/discharging currents were measured and analyzed as a function of the hold time, the delay time, the gate polarity during the FNT electron injection, the injection fluence and the annealing time after the injection had stopped. The charge-exchange current was distinguished from total current-transients containing the displacement current components. Charging/discharging current caused by the charge exchange was strongly dependent not only on the density of positive charges in the $SiO_2$, but also on the density of interface traps generated during the FNT electron injection. Several tentative mechanisms were suggested.

  • PDF

Modeling and parametric studies of PEM fuel cell performance (운전 조건에 따른 PEM 연료전지 모델링 및 성능 분석)

  • Noh, Young-Woo;Kim, Sae-Hoon;Jeong, Kwi-Seong;Son, Ik-Jae;Han, Kook-Il;Ahn, Byung-Ki
    • Journal of Hydrogen and New Energy
    • /
    • v.19 no.3
    • /
    • pp.209-216
    • /
    • 2008
  • In the present study, a mathematical model has been formulated for the performance of polymer electrolyte fuel cells. Modify the concentration polarization equation using concentration coefficient that represents the characteristics of bipolar plate reactant distribution. The model predictions have been compared with experimental results and good agreement has been demonstrated for the cell polarization curves. The effects of operating parameters on the performance of fuel cells have been studied. Increases of operation pressure reduce the effect of temperature on the performance.

Scale Formation in the Concentrate Compartment of an Electrodialysis Stack During Desalination of Brackish Water (염수의 탈염을 위한 전기투석 농축실에서의 스케일 형성)

  • Moon Seung-Hyeon;Yang Jung-Hoon;Yeon Kyeong-Ho
    • Membrane Journal
    • /
    • v.15 no.2
    • /
    • pp.175-186
    • /
    • 2005
  • An electrodialysis process was operated for a long period to investigate the scale formation on the membrane surface. During the desalination process, concentration of $Ca^{2+}$ and $SO_4^{2-}$ ions increased continuously in the concentrate compartment and eventually caused precipitation on the cation exchange membrane (Neosepta CMX) surface. During the initial scale formation, the performance of the process and membrane characteristics did not show significant changes, except the decrease in limiting current density of the CMX membrane occurring due to increase in the salt concentration in the concentrate compartment. Eventually, the limiting current density of the fouled CMX membrane dropped significantly to $300\;A/m^2$ as water dissociation occurred in the CMX membrane. It was concluded that the fouling was caused mainly by the scale formation on the cation exchange membrane surface in the concentrate and consequent water dissociation. Also the scale formation was reasonably predicted by the solubility of $CaSO_4$.

Application of Pine Peroxidase to the Amperometric Determination of Hydrogen Peroxidase (과산화수소의 전류법적 정량을 위한 소나무 과산화효소의 활용)

  • Yoon, Kil-Joong
    • Journal of the Korean Chemical Society
    • /
    • v.57 no.3
    • /
    • pp.329-334
    • /
    • 2013
  • A pine needle-embedded graphite enzyme electrode, of which bonding agent is CSM rubber, was newly designed and its electrochemistry was studied based on the amperometry. It involved a ground green leaves of pine tree as a zymogen together with electrochemical mediator, ferrocene within the paste. The plots of ln($i(1-e^{nf{\eta}})$) vs. ${\eta}$ and Lineweaver-Burk at the low potential (-100 to -500 mV) showed good linearities indicating that the amperometric response is by the catalytic power of pine peroxidase. Electrochemical parameters obtained, symmetry factor (${\alpha}$, 0.17), limiting current ($i_1$, 1.99 $A/cm^2$), exchange current density ($i_0$, $5.86{\times}10^{-5}\;A/cm^2$), Michaelis constant ($K_M$, $1.68{\times}10^{-3}$ M) and many others showed that pine peroxidase discharges the role of catalyst quantitatively on the electrode surface. Those proved that the practical use of pine peroxidase is promising in place of the marketed.

Concentration Polarization Phenomena in Ion-Exchange Membranes (이온교환막에서의 농도분극 현상)

  • 최재환;문승현
    • Membrane Journal
    • /
    • v.12 no.3
    • /
    • pp.143-150
    • /
    • 2002
  • Electrodialysis(ED) is a reliable and effective process for the separation and concentration of ionic compounds. However, commercial uses of ED are often hindered by the cost of the stack that mainly resulted from the ion-exchange membrane cost. In order to minimize the membrane cost, it is desired to operate ED at the highest practicable current density. In an actual ED system the high current operation is limited by the concentration polarization phenomenon. This article illustrates the transport phenomena of ions through ion exchange membranes using current-voltage relations as a characterizing method. Also recent studies on electroconvection and water-spitting phenomena caused by concentration polarization were reviewed.

Electrochemical determination of hydrogen peroxide using carbon paste biosensor bound with butadiene rubber (부타디엔 고무로 결합된 탄소반죽 바이오센서를 이용한 과산화수소의 전기화학적 정량)

  • Yoon, Kil-Joong
    • Analytical Science and Technology
    • /
    • v.23 no.5
    • /
    • pp.505-510
    • /
    • 2010
  • When polybutadiene dissolved in toluene was a binder of carbon powder, the volatility of solvent just after electrode fabrication assured the mechanical solidity of the carbon paste electrode. This characteristic met the qualifications for practical use of carbon paste electrodes. A new enzyme electrode bound with butadiene rubber was constructed. In order to confirm whether it shows quantitative electrochemical behaviors or not, its electrochemical kinetic parameters, e.g. the symmetry factor, the exchange current density, the capacitance of double layer, the time constant, the maximum current, the Michaelis constant and other factors were investigated. These experimental facts showed that butadiene rubber is a recommendable binder for practical use of a carbon paste electrode.

Preparation of Anion Exchange Membranes of Cross-linked Poly((vinylbenzyl)trimethylammonium chloride-2-hydroxyethyl methacrylate)/Poly(vinyl alcohol) (가교결합한 Poly((vinylbenzyl)trimethylammonium chloride-2-hydroxyethyl methacrylate)/poly(vinyl alcohol) 음이온 교환막 제조)

  • Kim, Mi-Yang;Kim, Kwang-Je;Kang, Ho
    • Applied Chemistry for Engineering
    • /
    • v.21 no.6
    • /
    • pp.621-626
    • /
    • 2010
  • Anion exchange membranes can be used for reverse electrodialysis for electric energy generation, and capacitive deionization for water purification, as well as electrodialysis for desalination. In this study, anion exchange membranes of poly((vinylbenzyl) trimethylammonium chloride-2-hydroxyethyl methacrylate)/poly(vinyl alcohol) were prepared through the polymerization of (vinylbenzyl)trimethylammonium chloride and 2-hydroxyethyl methacrylate in aqueous poly(vinyl alcohol) solutions, esterification with glutaric acid, and cross-linking reaction with glutaraldehyde. We investigated electrochemical properties for the anion exchange membranes prepared according to experimental conditions. Ion exchange capacity and electrical resistance for the membranes were changed with a variation in the monomer ratio in polymerization. Water uptake and conductivity for the membranes decreased with an increase in the content of glutaric acid in esterification. The change in the time of crosslinking reaction with the formed film and glutaraldehyde affected electrochemical properties such as water uptake, conductivity, or transport number for the membranes. Chronopotentiometry and limiting current density for the anion exchange membranes prepared were measured.

Amperometric Kinetics of Hydrogen Peroxide Biosensor Bound with Natural Rubber (천연고무로 결합된 과산화수소 정량 바이오센서의 전류법 속도론)

  • Rhyu, Keun-Bae;Yoon, Kil-Joong
    • Applied Chemistry for Engineering
    • /
    • v.21 no.6
    • /
    • pp.689-693
    • /
    • 2010
  • When natural rubber dissolved in toluene comes into use as a binder of carbon powder, the volatilization of solvent just after the construction of biosensor brought the mechanical robustness on the paste. This characteristic satisfied the pre-requisite condition for the practical use of carbon paste electrode and a biosensor for the determination of hydrogen peroxide was designed. In order to evaluate its electrochemical qualitative and quantitative behaviors, various electrochemical kinetic parameters of the electrode, e.g. the symmetry factor (${\alpha}$, 0.37), the exchange current density ($i_0$, $0.075mAcm^{-2}$), the capacitance of double layer ($C_d$, $9.7{\times}10^{-3}F$), the time constant (${\tau}_A$, 0.92 s), the maximum current ($i_{max}$, $5.92{\times}10^{-7}Acm^{-2}$), the Michaelis constant ($K_M$, $1.99{\times}10^{-3}M$) and others were investigated. Results show that natural rubber is a promising binder of carbon powder.

Study on a Separator for the Zn-Br Redox Flow Battery (Zn-Br 레독스 흐름 전지용 격막에 관한 연구)

  • Na, Il-Chae;Jo, Hong-Sic;Ryu, Cheol-Hwi;Hwang, Gab-Jin
    • Membrane Journal
    • /
    • v.24 no.5
    • /
    • pp.386-392
    • /
    • 2014
  • Two commercial membranes (porous membrane and cation exchange membrane) were evaluated as a separator in the Zn-Br redox-flow battery (ZBRFB). The performance properties of ZBRFB were test in the current density of $20mA/cm^2$. The electromotive forces (OCV at SOC 100%) of ZBRFB using SF-600 (porous membrane) and Nafion 117 (cation exchange membrane) were 1.87 V and 1.93 V, respectively. The cycle performance of ZBRFB using each membrane was evaluated during 7 cycles. The performance of ZBRFB using SF-600 membrane was 89.76%, 83.46% and 74.88% for average current efficiency, average voltage efficiency and average energy efficiency, respectively. The performance of ZBRFB using Nafion117 membrane was 97.7%, 76.33% and 74.56% for average current efficiency, average voltage efficiency and average energy efficiency, respectively.