Park, Minhyuk;Park, Sang-Won;Lim, Hyun-Pil;Park, Chan;Yun, Kwi-Dug
The Journal of Korean Academy of Prosthodontics
/
v.58
no.3
/
pp.257-267
/
2020
The goal of suction denture is to enhance retention of dentures by the formation of negative pressure between the denture base and the underlying tissue and sealing around the denture by the mucosa. This patient has been converted to a completely edentulous state after the extraction of residual teeth. Fabrication of suction denture was planned because it was estimated that the conventional compete would be hard to achieve retention due to the absorption of residual ridge and lack of sublingual fold. Through appropriate clinical and laboratory technique such as preliminary impression on the mandibular rest position, provisional vertical dimension determination with Centric Tray® (Ivoclar Vivadent AG, Schaan, Liechtenstein), closed mouth definitive impression and jaw relation record using individual tray with Gnathometer M® (Ivoclar Vivadent AG, Schaan, Liechtenstein), artificial teeth arrangement considering stability of the denture, and proper polymerization technique that minimizes polymerization shrinkage, restoring the patient with suction denture resulted in satisfaction throughout the function and asesthetics.
Journal of Dental Rehabilitation and Applied Science
/
v.27
no.2
/
pp.233-245
/
2011
With the use of computed tomography (CT), computer-aided design/computer-assisted machining (CAD/CAM) technology and internet, the implant dentistry has been evolved. The surgical templates made by CAD/CAM technology and precise installation of implants, permit restorations to be inserted immediately after implants have been placed. The advantages of CAD/CAM guided implant procedures are flapless, minimally invasive surgery and shorter surgery time. With this technique, less postoperative morbidity and delivery of prosthesis for immediate function would be possible. A patient with an edentulous maxilla and mandible received 7 implants in mandible using CAD/CAM surgical templates. Prefabricated provisional fixed prostheses were connected immediately after implant installation. Provisional prostheses were evaluated for aesthetics and function during 6 months. Definitive prostheses were fabricated. At 6 months recall appointment, patient's occlusion was slightly changed. To prevent additional adverse effect, regular check-up and occlusal adjustment would be needed.
Journal of Dental Rehabilitation and Applied Science
/
v.32
no.4
/
pp.263-273
/
2016
In the implant prosthetic procedure, the soft tissue reaction was varied with the material and surface treatment of the abutment. It may be the cause of the peri-implantitis, and hence it can affect the long-term prognosis of the implant prosthesis. Titania and zirconia abutment presented superior biocompatibility and stable soft tissue reaction, while gold alloy abutment showed unfavorable reaction sometimes. A soft tissue reaction can be differed by the surface characteristics even in the same material type. Because rougher surface induces a bacterial attachment, the part contacting a soft tissue should have smooth surface. Additional surface treatment can enhance the cellular response without increasing bacterial attachment. Repeated removal and insertion of the abutment and the shape of the abutment may affect the soft tissue reaction, also. Ultrasonic cleaning and argon plasma cleaning are effective way to clean the retained micro-dust on the customized abutment.
All-on-six concept can be used as one of the treatment options to maximize the use of available residual alveolar bone for implant-supported fixed prosthesis on edentulous patients. But this process is complex and cumbersome. Digital system can be used at multiple steps, from implantation to prosthetic restoration, to overcome this shortcoming. In this case of a maxillary edentulous patient aged 76, digital system was used for restoration of 1-piece design, screw retained fixed prosthesis from diagnosis, implant surgery to fabrication of provisional and final prosthesis. For preoperative diagnosis and treatment planning stage, intra-oral information of a patient was digitalized by direct intra-oral scan. Surgical guide and immediate provisional prosthesis was designed based on this digitalized data. Patient's inconvenience was minimized by applying immediate provisional prosthesis, which was delicately fabricated according to the location data of six implants on most suitable residual alveolar bone. Then, final prosthesis was designed and fabricated going through new interim prosthesis which was newly designed and fabricated, considering patient's requests, stable vertical dimension and occlusion, and esthetic factors using digital system. We hereby report a case successfully applying digital system to multiple steps including implant surgery to fabricating prosthesis, to simplify existing complicated implant treatment procedure to an edentulous patient.
Kim, Minji;Song, Ji-Soo;Shin, Teo Jeon;Hyun, Hong-Keun;Kim, Young-Jae;Kim, Jung-Wook;Lee, Sang-Hoon;Jang, Ki-Taeg
The Journal of Korea Assosiation for Disability and Oral Health
/
v.15
no.1
/
pp.45-49
/
2019
Bartter syndrome is an inherited renal tubular disorder characterized by hypokalemia, hypochloremic metabolic alkalosis, hyperreninemia, hyperprostaglandinism, and normal blood pressure. Bartter syndrome is classified by neonatal and classic type. Clinical manifestation of Bartter syndrome considered in dental treatment include tendency to dehydration, vomiting and erosion, attrition and abrasion of the teeth. A 2-year-4 month old boy with Bartter syndrome type III was referred to the Seoul National University Dental Hospital for dental evaluation and treatment. He showed hypokalemic hypochloremic metabolic alkalosis and had been treated with indomethacin and potassium chloride. He had hypocalcified teeth with or without multisurface caries lesions in all dentition and the erosion of maxillary teeth was detected. Dental procedure under general anesthesia was scheduled due to multiple caries and his medical condition. The dental procedure was successfully performed. This case suggests that electrolyte imbalances need to be treated prior to dental treatment and complete coverage restoration is necessary to protect the eroded teeth. An appropriate management plan for the patients with Bartter syndrome should include considerations of the need for close interaction with the pediatrician for pre- and post-operative care. General anesthesia may be recommendable to manage the patients having multiple caries with Bartter syndrome.
Journal of Dental Rehabilitation and Applied Science
/
v.35
no.3
/
pp.113-122
/
2019
Tooth wear is gradually increasing with increasing life expectancy. In particular, it is important to establish a treatment plan in the early stages so that it does not proceed to moderate or severe wear stages. It is essential to diagnose tooth wear accurately in order to plan a treatment for it. There are many risk factors including age, diet, and drugs which affects tooth wear. For the diagnosis of a tooth wear, appropriate index and evaluation method should be used. There were various tooth wear indices such as TWI, Lussi index, BEWE, and TWES. The evaluation method includes clinical examination, dental cast examination and clinical photographs. Recently, a 3D scanner is being used to assess tooth wear. The risk factors, tooth wear evaluation system, the methods of measuring tooth wear, and related literature were reviewed. The strengths and weaknesses of each index and evaluation methods were compared to derive a proper way to diagnose tooth wear.
Park, Se-Hyun;Sung, Han-Gyul;Ko, Kyung-Ho;Huh, Yoon-Hyuk;Park, Chan-Jin;Cho, Lee-Ra
The Journal of Korean Academy of Prosthodontics
/
v.59
no.3
/
pp.359-369
/
2021
Implant prostheses and removable partial dentures are mainly used as treatment methods for partial edentulous patients who have lost a number of teeth. The implant-assisted removable partial denture (IARPD) is strategically selected. The defect in maxillofacial structure due to osteomyelitis, a type of facial bone infection, causes dysfunction such as mastication, swallowing, and pronunciation, as well as social and psychological effects, so a removable restoration is required to restore the supporting tissue. Design of abutment and partial dentures is an essential factor in the success of treatment. In this case, IARPD, which has superior retention and stability compared to traditional removable partial dentures, can have a good prognosis. In a partial edentulous patient with bone defects due to osteomyelitis treatment, the stability of the denture was secured with IARPD restoration. Moreover, maintenance problem that may occur in the future was minimized by providing an appropriate denture design and occlusal scheme through several provisional restorations. This case can be expected to have a favorable prognosis in the long term.
Journal of Dental Rehabilitation and Applied Science
/
v.37
no.1
/
pp.1-15
/
2021
Additive manufacturing (AM) for dental materials can produce more complex forms than conventional manufacturing methods. Compared to milling processing, AM consumes less equipment and materials, making sustainability an advantage. AM can be categorized into 7 types. Polymers made by vat polymerization are the most suitable material for AM due to superior mechanical properties and internal fit compared to conventional self-polymerizing methods. However, polymers are mainly used as provisional restoration due to their relatively low mechanical strength. Metal AM uses powder bed fusion methods and has higher fracture toughness and density than castings, but has higher residual stress, which requires research on post-processing methods to remove them. AM for ceramic use vat polymerization of materials mixed with ceramic powder and resin polymer. The ceramic materials for AM needs complex post-processing such as debinding of polymer and sintering. The low mechanical strength and volumetric accuracy of the products made by AM must be improved to be commercialized. AM requires more research to find the most suitable fabrication process conditions, as the mechanical properties and surface of any material will vary depending on the processing condition.
Park, Chan-Ho;Ko, Kyung-Ho;Park, Chan-Jin;Cho, Lee-Ra;Huh, Yoon-Hyuk
Journal of Dental Rehabilitation and Applied Science
/
v.37
no.4
/
pp.177-185
/
2021
Clinical applications of translucent zirconia as well as traditional zirconia (3 mol% yttria stabilized tetragonal zirconia polycrystal, 3Y-TZP) are increasing. For this reason, studies on factors affecting the optical properties of dental zirconia have been continuously reported. The optical effect of dental zirconia may vary depending on the yttria content, the thickness of the prosthesis, the sintering process, polishing, glazing and cementation in laboratory and clinical procedures. Increasing the yttria concentration can reduce the masking effect. Translucency decreases as the thickness of the restoration increases, but the required thickness may vary depending on the properties of the zirconia block. The high-speed sintering method can shorten the manufacturing time, but in some cases, the translucency of the prosthesis may decrease. In addition, the optical properties can be affected by the surface roughness of zirconia and the polishing process. The use of an appropriate colored cement can help with the masking effect of zirconia and can be useful for color matching for more esthetic results.
Recently with the advance in digital dentistry, the fabrication of dentures using computer-aided design and computer-aided manufacturing (CAD-CAM) is on the rise. The denture designed through a CAD software can be produced in a 3-dimensional manufacturing process. This process includes a subtractive processing method such as milling and an additive processing method such as 3D printing and in which it can be applied efficiently in more complex structures. In this case, complete dentures were fabricated using Stereolithography (SLA)-based 3D printing to shorten the production time and interval of visits in patient with physical disabilities due to cerebral infarction. For definitive impression, the existing interim denture was digitally replicated and used as an individual tray. The definitive impression obtained with polyvinyl siloxane impression material was including information about the inclination and length of the maxillary anterior teeth, vertical dimension, and centric relation. In addition, facial scan data with interim denture was obtained so that it can be used as a reference in determination of the occlusal plane and in arrangement of artificial teeth during laboratory work. Artificial teeth were arranged through a CAD program, and a gingival festooning was performed. The definitive dentures were printed by SLA-based 3D printer using a FDA-approved liquid photocurable resin. The denture showed adequate retention, support, and stability, and results were satisfied functionally and aesthetically.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.