• Title/Summary/Keyword: 교합기

Search Result 295, Processing Time 0.027 seconds

DIFFERENCE IN BOND STRENGTH ACCORDING TO FILLING TECHNIQUES AND CAVITY WALLS IN BOX-TYPE OCCLUSAL COMPOSITE RESIN RESTORATION (박스 형태의 복합레진 수복시 충전법 및 와동벽에 따른 결합력 차이에 관한 연구)

  • Ko, Eun-Joo;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.4
    • /
    • pp.350-355
    • /
    • 2009
  • Bond strength depends on characteristics of bonding surface and restorative technique. The majority of studies dealing with dentin bond strength were carried out on flat bonding surface, therefore, difference of bond strength between axial wall and pulpal wall is not clear yet. This study evaluated bonding difference between cavity walls in class I composite resin restoration with different filling techniques. Twenty extracted caries-free human third molars were used. Cavities were prepared in 6 ${\times}$4 ${\times}$3 mm box-type and divided into four groups according to filling technique and bonding surface: Group I; bulk filling - pulpal wall, Group II; bulk filling - axial wall, Group III; incremental filling - pulpal wall, Group IV; incremental filling - axial wall. Cavities were filled with Filtek $Z250^{(R)}$(3M/ESPE., USA) and Clearfill SE $bond^{(R)}$(Kuraray, Japan). After 24 hour-storage in $37^{\circ}C$water, the resin bonded teeth were sectioned bucco-lingualy at the center of cavity. Specimens were vertically sectioned into 1.0 ${\times}$1.0 mm thick serial sticks perpendicular to the bond surface using a low-speed diamond saw (Accutom 50, Struers, Copenhagen, Denmark) under water cooling. The trimmed specimens were then attached to the testing device and in turn, was placed in a universal testing machine (EZ test, Shimadzu Co., Kyoto, Japan) for micro-tensile testing at a cross-head speed of 1 mm/min. The results obtained were statistically analyzed using 2-way ANOVA and t-test at a significance level of 95%. The results were as follows: 1. There was no significant difference between bulk filling and incremental filling. 2. There was no significant difference between pulpal wall and axial wall, either. Within the limit of this study, it was concluded that microtensile bond strength was not affected by the filling technique and the site of cavity walls.

Comparison of adhesive strength of resinous teeth splinting materials according to enamel surface treatment (법랑질 표면 처리방법에 따른 레진계 치아 고정재료의 접착강도 비교)

  • Lee, Ye-Rim;Kim, Soo-Yeon;Kim, Jin-Woo;Park, Se-Hee;Cho, Kyung-Mo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.35 no.2
    • /
    • pp.72-80
    • /
    • 2019
  • Purpose: The purpose of this study is to compare and analyze the shear bond strength and fracture pattern in different enamel tooth surface treatments for resin splinting materials. Materials and Methods: G-FIX and LightFix were used as tooth splinting materials. Twenty bovine mandibular incisors were used for the preparation of the specimens. The exposed enamel surface was separated into four parts. Each tooth was treated with 37% phosphoric acid, 37% phosphoric acid + adhesive resin, 37% phosphoric acid + G-premio bond, and G-premio bond for each fraction. Shear bond strength was measured using a universal testing machine. After measuring the shear bond strength, the fractured surface of the specimen was magnified with a microscope to observe the fracture pattern. Two-way ANOVA was used to verify the interaction between the material and the surface treatment method. One-way ANOVA was used for comparison between the surface treatment methods of each material and post-hoc test was conducted with Scheffe's test. An independent t-test was conducted to compare shear bond strengths between materials in each surface treatment method. All statistics were conducted at 95% significance level. Results: G-FIX, a tooth splinting resin, showed similar shear bonding strength when additional adhesive resins were used when material was applied after only acid etching, and LightFix showed the highest shear bonding strength when additional adhesive resins were used after the acid etching. In addition, both G-FIX and LightFix showed the lowest shear bond strength when only self-etching adhesive was applied without additional acid etching. Verification of interactions observed interconnection between resins and surface treatment methods. Most of the mixed failure was observed in all counties. Conclusion: When using G-FIX and LightFix, which are tooth-splinting materials, it is considered that sufficient adhesion will be achieved even after applying only acid etching as instructed by the manufacturer.

Effect of storage condition of resin cement on shear bond strength of the orthodontic bracket (레진시멘트의 보관 조건이 치열교정용 브라켓의 전단접착강도에 미치는 영향)

  • Seul-Gi, Yi;Jin-Woo, Kim;Se-Hee, Park;Yoon, Lee;Eung-Hyun, Kim;Kyung-Mo, Cho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.4
    • /
    • pp.189-195
    • /
    • 2022
  • Purpose: For orthodontic bracket bonding, light curing resin cement is widely used because the process is convenient, and it can be polymerized at the desired time. This study compared the difference of bonding strength of orthodontic resin cement according to storage condition. Materials and Methods: After acid etching the bovine enamel surface with 37% phosphoric acid, 15 orthodontic brackets for mandible incisors were bonded with Ortho Connect and Orthomite LC according to following three conditions; 1) Immediate after 4℃ refrigeration for 3 months (IR), 2) One day room temperature after 4℃ refrigeration for 3 months (OR), 3) Room temperature for 3 months (RT). The shear bond strength was measured with a universal material tester and failure pattern of the specimen was observed. Two-way ANOVA and One-way ANOVA were used at the 95% significance level. Results: Ortho Connect that was applied immediately after refrigeration showed the maximum shear bond strength. Orthomite that was applied immediately after refrigeration showed the lowest shear bond strength, and the group stored at room temperature for three months showed the highest shear bond strength, and the difference between the two groups was significant. Conclusion: Ortho Connect can be used without worrying about bond strength even if it is used immediately after refrigeration, but Orthomite should be kept at room temperature sufficiently after refrigeration.

The influence of fitness and type of luting agents on bonding strength of fiber-reinforced composite resin posts (섬유강화 복합레진 포스트의 결합강도에 대한 포스트 공간 적합도 및 접착 시멘트의 영향)

  • Kkot-Byeol Bae;Hye-Yoon Jung;Yun-Chan Hwang;Won-Mann Oh;In-Nam Hwang
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.39 no.4
    • /
    • pp.187-194
    • /
    • 2023
  • Purpose: A mismatched size in the post and post space is a common problem during post-fixation. Since this discordance affects the bonding strength of the fiber-reinforced composite resin post (FRC Post), a corresponding luting agent is required. The aim of this study was to evaluate the bonding strength of the FRC post according to the fitness of the fiber post and the type of luting agent. Materials and Methods: Thirty mandibular premolar were endodontic-treated and assigned to two groups according to their prepared post space: Fitting (F) and Mismatching (M). These groups were further classified into three subgroups according to their luting agent: RelyX Unicem (ReX), Luxacore dual (Lux), and Duolink (Duo). A push-out test was performed to measure the push-out bond strengths. The fractured surfaces of each cross-section were then examined, and the fracture modes were classified. Results: In the ReX and Duo subgroups, the F group had a higher mean bond strength; however, the Lux subgroup had no significant difference between the F and M groups. In the analysis of the failure modes, the ReX subgroup had only adhesive failures between the cement and dentin. Conclusion: The result of this study showed that the bond strength of an FRC post was influenced by the type of luting agent and the mismatch between the diameter of the prepared post space and that of the post.

An Analysis of Morphological Variation in Abies koreana Wilson and A. nephrolepis (Traut.) Maxim. of Korea (Pinaceae) and Their Phylogenetic Problems (한국산(韓國産) 분비나무와 구상나무의 형질분석(形質分析)과 종간유연관계(種間類緣關係))

  • Chang, Chin-Sung;Jeon, Jeong Ill;Hyun, Jung Oh
    • Journal of Korean Society of Forest Science
    • /
    • v.86 no.3
    • /
    • pp.378-390
    • /
    • 1997
  • Ten total populations of Korean fir (Abies koreana Wilson) and Manshurian fir [A. nephrolepis (Traut.) Maxim.] were sampled from south Korea to investigate patterns of intraspecific variation in these species and to evaluate a recognition of the two species. Principal components analysis and cluster analysis were performed both on seed-cone data and on needle morphology data. The characters that contributed most to the separation between A. koreana and A. nephrolepis along three principal components axis were leaf width, length of seed, width of seed wing, length of seed wing, cone width, width of scale, and length of bract tip, but these characters were not diagnostic because of overlap in reality. Therefore, all these characters were not reliable in distinguishing these two taxa including bract position (exerted and recurved vs. exerted and straight). The individuals of A. koreana from Mt. Chi-ri appeared quite unique probably on account of its larger cone size and longer scale tip, while those from Mt. Hal-la of A. koreana were generally distinct from others in terms of their larger seed and seed wing and longer scale width. The Mt. Duk-yu specimens of A. korecana appeared somewhat smaller but more data were needed due to the small sampling size. Generally, the gradual clinal geographic trends made evident by the position of resin ducts in leaves of A. koreana can be detected. The southern populations, Mt. Hal-la (an insular population) were generally distinct from the northern populations (Mt. Chi-ri, Mt. Ga-ya and Mt. Duk-yu) in terms of their position of resin duct (medial, within mesophyll vs marginal, close to epidermis : 100% vs 75 or 50%). Although no sharp boundary separating these two species could be detected based on cone and needle morphology, the observed clinal pattern was distinct in northern populations of A. koreana and southern population of A. nephrnlepis. In a preceding study of the flavonoids variation of 20 species in eastern Asia, flavanone (5-deoxyflavanone) was found to be characteristic of A. faxoniana Rehder et Wilson, A. georgei Orr of China and A. koreana of Korea. A. faxoniana, which is assumed to be primitive species, has position of resin duct relative to both the medial and the marginal, while A. georgei and A. koreana are identified by marginal position of resin duct. With respect of foliar flavonoids chemistry, A. koreana was distinct from A. nephrolepis : the southmost samples (Mt. Hal-la and Mt. Chi-ri) contained additional flavonoids derivatives (mainly flavanone) that were not found in the northmost samples of A. nephrolepis except a few individuals from Mts. Seo-rak and Tae-bak populations of Kwang-won province. The presence of A. koreana type flavonoids in two Chinese species suggested that position of resin duct may be a phyletic character. Abies koreana including two Chinese taxa, exhibited the most elaborate and specialized flavonoids profile within the Abies in eastern Asia. Contrary to our initial expectations, the apparent intermediates between A. nephrolepis and A. koreana in Duk-yu and Ga-ya mountains were found. The pattern of variation on position of resin duct and flavonoids chemistry in these populations of A. kareana suggested that genetic interchange or natural hybridization had occurred between these two species. The evidence needed to resolve the status of this taxon is still inconclusive in our opinion until intermediate individuals from Mts. Duk-yu and Ga-ya show indication of hybridization between the two species.

  • PDF