• 제목/요약/키워드: 교정 호선

검색결과 53건 처리시간 0.019초

호선에 부여한 loop와 교정용 고무가 치궁만곡도 개선에 미치는 영향에 관한 광탄성학적 연구 (A PHOTOELASTIC STUDY OF THE EFFECT OF LOOPS IN ARCH WIRE AND ORTHODONTIC ELASTICS IN RELIEF OF CURVE OF SPEE)

  • 이병태
    • 대한치과교정학회지
    • /
    • 제23권4호
    • /
    • pp.485-492
    • /
    • 1993
  • Multiloop Edgewise Archwire(MEAW) is effective in relief the Curve of Spee in mandibular arch but up Sl down orthodontic elastics must be used with it. The purpose of this study was to analyse the effect of orthodontic elastics, like as up & down elastics, Class II elastics, and Class III elastics, and the effect of L loop in Multioop Edgewise Archwire. 1. Intrusive force of MEAW in anterior teeth was reduced and uprighting force in premolars was increased by up & down elastics. 2. Uprighting force was significintly increased with Class III elastics in multiple L loop arch wire. 3. The force of Class II elastics made molars tip mesially and Curve of Spee deep.

  • PDF

상악 절치부-토크에 의한 치아 이동과 응력 분포에 관한 유한요소법적 연구 (Three-dimensional finite element analysis on the effect of maxillary incisor torque)

  • 윤현주;임용규;이동렬;조영수
    • 대한치과교정학회지
    • /
    • 제35권2호
    • /
    • pp.137-147
    • /
    • 2005
  • 본 연구는 상악 절치부에 active 토크가 가해졌을 경우, 교정력을 직접 받은 치아와 인접 치아의 반응을 알아보고자, 상악 치아 및 치조골의 유한요소 모델을 제작하고, stainless steel NiTi, TMA 세 종류의 각형 호선을 육면체 요소로 모델링하여 유한요소 모델을 완성하였다. 호선이 브라켓에 삽입되었을 때 브라켓에 발생하는 반력과 모멘트를 구하였고, 이것을 유한 요소 모델에 적용하여 각 치아의 변위와 응력 분포를 측정하였다 브라켓에 발생하는 반력은 근원심 방향과, 협설 방향으로의 힘은 0에 가까우며, 중절치, 측절치, 견치의 브라켓 근심측에서는 정출력이 원심측에서는 압하력이 발생하였다. 힘과 모멘트의 크기는 측절치에서 최대였고 중절치. 견치 순으로 감소하였고, 소구치 부위와 대구치 부위에서는 급격히 감소하였다. 중절치와 측절치는 치관 협측, 원심 경사 이동과 압하를 보였으며 견치는 치관 설측 원심 경사와 정출을 보였고. 제1소구치는 치관 설측 경사이동을 보였다. $019\times025SS$을 사용하여 상악 절치부에 토크를 부여하는 경우에는 측절치에 과도한 힘이 집중되므로, 임상에서 토크를 조절 할 경우에는 NiTi나 TMA 호선을 사용하는 것이 바람직하리라고 생각된다.

토오크 양에 따른 세라믹 브라켓의 파절 저항성 (Fracture resistance of ceramic brackets to arch wire torsional force)

  • 한정흠;장민희;임용규;이동렬
    • 대한치과교정학회지
    • /
    • 제37권4호
    • /
    • pp.293-304
    • /
    • 2007
  • 본 연구에서는 임상에서 쓰이는 수종의 치과교정용 세라믹 브라켓에 교정용 호선으로 토오크 적용 시 파절에 저항하는 정도를 비교하고 그 파절 양상을 관찰하였다. $022\;{\times}\;028-inch$ slot을 가진 상악 중절치 세라믹 브라켓에 $0215\;{\times}\;027-inch$ 스테인레스 강 교정용 호선에서 발생하는 설측 치근 토오크를 적용시켜 각 15개씩 7종의 브라켓을 시험하였다. 파절 시험용 장치를 제작하고 토오크 각도를 증가시키면서 만능시험기로 세라믹 브라켓이 파절되는 순간의 토오크 값을 측정하였다. 또한 세라믹 브라켓의 파절 양상을 알아보고자 토오크 값 측정 후 파절이 일어난 부위를 관찰하고 그 위치를 기록한 주사전자현미경으로 파절면을 관찰하였다. 나타난 결과를 토대로 볼 때 세라믹 브라켓의 결정구조와 제조 방법이 파절 저항성에 크게 영향을 주는 것으로 나타났다. 단결정 알루미나 (Inspire) 브라켓이 InVu를 제외한 다결정 알루미나 브라켓에 비하여 토오크에 대한 파절 저항성이 유의성 있게 크게 나타났다 (p < 0.05). Metal slot이 삽입된 브라켓은 그렇지 않은 브라켓과 토오크에 대한 저항성에서 유의한 차이를 보이지 않았다 (p >0.05). 파절 양상에 관한 관찰에서는 metal slot이 있는 다결정 알루미나 브라켓인 Clarity는 모두 절단측 slot base에서 부분적으로만 파절이 일어났고 다른 종류의 브라켓들은 다양한 부위에서 파절이 일어났다. 본 연구 결과, 실험에 사용한 모든 세라믹 브라켓에서 파절이 일어난 순간의 토오크 값과 토오크 각은 실제로 상악 중절치의 치근을 이동하는데 필요한 토오크보다 큰 것이었으므로, 실제 임상 치료 시 적절한 파절 저항을 나타낼 것으로 보였다.

브라켓과 탄선 간의 마찰 전후 표면 변화 분석 - 원자현미경을 이용한 예비연구 (Changes in surface roughness of bracket and wire after experimental sliding - preliminary study using an atomic force microscopy)

  • 이태희;박기호;전지윤;김수정;박헌국;박영국
    • 대한치과교정학회지
    • /
    • 제40권3호
    • /
    • pp.156-166
    • /
    • 2010
  • 브라켓과 호선 간에 발생하는 마찰은 치아 이동의 효율에 상당한 영향을 미친다. 마찰력에 기여하는 요소 중 특히 브라켓과 호선의 표면조도는 중요한 요소이다. 본 연구는 브라켓과 탄선을 실험적으로 마찰시킨 후, 원자현미경 (atomic force microscope, AFM)을 사용하여 브라켓 슬롯과 교정용 탄선의 표면 조도 변화를 정성적, 정량적으로 측정하고 비교 평가하여 브라켓과 호선 간의 마찰이 각각의 표면 변화에 미치는 영향을 규명하고자 시행되었다. 스테인리스 스틸 브라켓과 세라믹 브라켓에 각각 스테인리스 스틸 탄선과 TMA 탄선을 실험적으로 활주마찰시킨 후 각각을 원자현미경을 이용하여 표면을 관찰하였다. 실험결과 브라켓보다는 교정용 탄선에서 활주마찰 후에 더 많은 표면 변화가 나타났다. 또한 활주마찰 후에 스테인리스 스틸 브라켓은 표면 조도의 유의한 변화가 없었으나 세라믹 브라켓은 표면 조도가 감소하였다. 그리고 교정용 탄선은 모두 활주마찰 후에 표면 조도가 증가하였으며 이러한 표면 변화는 스테인리스 스틸 브라켓보다 세라믹 브라켓과의 활주마찰 후에 더 큰 것으로 관찰되었다. 본 실험으로 원자현미경은 브라켓 슬롯과 탄선의 표면 조도를 정량적으로 측정하는 데에 유용한 수단임을 알 수 있었다.

치아교정용 호선의 굽힘 영향 예측 (Prediction of the Bending Effect of an Archwire for Orthodontics)

  • 이기준;조영수;김시범;이권희
    • 한국기계가공학회지
    • /
    • 제9권6호
    • /
    • pp.95-100
    • /
    • 2010
  • For orthodontic treatment, most commonly, an archwire is inserted into orthodontic brackets that can be made from stainless steel. Then, the archwires interact with the brackets to move teeth into the desired positions. However, the activation of an archwire may induce undesirable rotation of a tooth due to the moment application. An appropriate magnitude of the gable bends of an archwires prevents its rotation. However, it is not easy to predict the relationship between the rotation and the gable bend. This study presents the numerical approach to predict the rotation of a tooth with respect to the gable bend in the activation of an archwire. To predict the rotation of a tooth, the kriging interpolation method is introduced.

전치부 반대 교합을 동반한 골격성 3급 부정교합 환자의 치료에 관한 연구 (A STUDY ON THE EFFECT OF TREATMENT IN THE SKELETAL CLASS III MALOCCLUSION PATIENT WITH ANTERIOR CROSSBITE)

  • 문윤식
    • 대한치과교정학회지
    • /
    • 제23권4호
    • /
    • pp.475-483
    • /
    • 1993
  • The purpose of this study was to investigate the treatment effects on anterior crossbite patients using chin cap and labiolingual arch appliance. In the present study, I statistically evaluated measurement values on a cephalogram before and after treatment form twenty anterior crossbite cases. The results were as follows: 1. In the craniofacial patterns, cranial base increased after treatment. 2. In the maxillo-mandibular relationship, ANB and Facial convexity significantly increased. 3. In the denture patterns, occlusal plane, Ul to FH and Overjet significantly increased. On the contrary overbite decreased significantly. Lower incisors inclined lingually. 4. In the soft tissue profile changes, lower lip protrusion was signifacantly improved.

  • PDF

브라켓 각도 변화에 따른 세라믹 브라켓의 마찰력 측정 (Evaluation of friction of ceramic brackets in various bracket-wire combinations)

  • 차정열;김경석;김동춘;황충주
    • 대한치과교정학회지
    • /
    • 제36권2호
    • /
    • pp.125-135
    • /
    • 2006
  • 최근 사용되고 있는 세라믹 브라켓의 마찰력을 측정하고 비교하고자 실험군으로 3종의 세라믹 브라켓(Crystaline $V^{(R)}$, Tomy, Tokyo, Japan; $Clarity^{(R)}$, 3M Unitek, CA; $Inspire^{(R)}$, Ormco, CA)을 사용하였으며 대조군으로 컴퍼짓 레진브라켓($Spirit^{(R)}$, Ormco, CA)과 메탈브라켓($Kosaka^{(R)}$, Tomy, Tokyo, Japan)을 사용하였다. 활주 시 마찰력은 4개의 브라켓-교정선 경사$(0^{\circ},\;5^{\circ},\;10^{\circ},\;15^{\circ})$에서 각각 측정되었으며 두 종의 교정선 [1. 스테인레스 스틸(Stainless Steel, SDS Ormco, Glendora, CA), 2. 베타-타이타늄(TMA, SDS Ormco, Glendora, CA)]이 사용되었다. 22 mil 브라켓을 만능시험기기에 부착한 후 $.021{\times}.025$ 크기의 교정선에 고무결찰한 후 $34^{\circ}C$의 건조상태에서 5 mm/min 속도로 교정 선을 활주시켰다. TMA 교정선은 스테인레스 스틸 교정선보다 높은 마찰력을 발생시켰으며 모든 브라켓 호선과의 조합에서 브라켓-교정선의 각도가 증가함에 따라 정적, 동적 마찰력이 증가하였다. $0^{\circ}{\sim}5^{\circ}$ 구간에서 마찰력의 크기는 스테인레스 스틸 교정선과 레진 브라켓 조합이 가장 낮게 측정되었으며 다음으로 Crystaline V, 금속 브라켓, Clarity, Inspire의 순으로 나타났다. TMA 교정선에서는 Crystaline V와의 조합이 가장 낮은 마찰력을, 다음으로 컴퍼짓 브라켓, Clarity, 금속 브라켓, Inspire 순으로 나타났다. $5^{\circ}$ 이상에서 마찰력이 급격하게 증가하였으며 스테인레스 스틸 교정선에서 레진 브라켓, Clarity, Crystaline V, 금속 브라켓, Inspire순으로 나타났다. TMA 교정선에서는 레진 브라켓, Crystaline V, Clarity, Inspire, 금속 브라켓 순으로 나타났다. 이때 호선 브라켓 조합에 대한 마찰력은 일반적으로 증가하였으나 마찰력 증가율의 차이로 인해 그룹간 마찰력의 순위가 서로 뒤바뀌는 경우가 관찰되었다. 실리카-삽입 세라믹 브라켓은 기존의 세라믹 브라켓보다 낮은 마찰력을 보여줄 뿐 아니라 브라켓-교정선의 경사도의 증가에서도 비교적 낮은 마찰력 증가율을 나타내어 세라믹 브라켓의 높은 마찰력을 감소시키는데 큰 역할을 할 수 있다고 생각된다.

상악 제1 및 제2소구치의 발치공간 폐쇄기전에 대한 3차원 유한요소 해석의 비교 연구 (Comparison of finite element analysis of the closing patterns between first and second premolar extraction spaces)

  • 고신애;임원희;박선형;전윤식
    • 대한치과교정학회지
    • /
    • 제37권6호
    • /
    • pp.407-420
    • /
    • 2007
  • 교정 치료에서 발치공간 폐쇄는 치열을 이루는 모든 치아의 연속적인 이동으로 이루어지므로 그 기전은 복잡하다. 특히 전치부 치축을 적절히 유지하면서 구치부 고정원을 조절하는 과정은 정교함을 요하기 때문에 입체적 분석을 통한 치아이동 양상에 대한 이해가 필요하다. 지금까지의 유한요소 분석은 초기 응력분포를 관찰하여 치아 이동양상을 예측해 보는데 그쳤지만 이러한 양상만으로 정확한 치아이동 결과를 추정하는 데에는 한계가 있었다. 따라서 본 연구에서는 3차원 유한요소 모델을 이용하여 상악 제1소구치 및 제2소구치 발치공간 폐쇄 시 전치부와 구치부의 입체적인 이동 양상을 단계별로 비교하여 그 기전을 규명하고자 하였다. 자연치의 크기 및 형태를 갖는 상악 치아들과 브라켓, 교정용 호선 및 치조골부를 3차원 레이저 스캐너로 스캐닝한 후 사면체 요소의 유한요소 모델을 제작하였다 $0.017"{\times}0.025"$ 스테인레스 강 호선에 제작된 bull 루프 후방에 $10^{\circ}$ gable bend를 부여하고 한 번에 2 mm씩 12회 활성화시켜 발치공간을 폐쇄시켰다. 그 결과 제1소구치를 발치한 경우 제2소구치 발치에 비해 전치부의 후방 이동량이 많았으며 구치부의 전방 이동량은 더 적게 나타났다. 전치부에서는 제f, 2소구치 발치 모두 비슷한 미약한 정출을 동반하였고 치축의 변화량은 제1소구치 발치에서 더 크게 나타났다. 또한 제2소구치 발치 시 고정원의 협측 이동량이 더 크게 나타났다

심미 브라켓의 종류와 브라켓-호선 각도에 따른 마찰 저항에 대한 연구 (Evaluation of friction of esthetic brackets according to different bracket-wire angulations)

  • 제영지;장민희;임용규;이동렬
    • 대한치과교정학회지
    • /
    • 제37권5호
    • /
    • pp.341-350
    • /
    • 2007
  • 본 실험은 마찰력을 줄이고 물리적 성질을 개선하여 최근에 개발된 수 종의 심미 브라켓들과 교정 탄선간에 발생하는 마찰력의 크기를 측정, 비교해 보고자 하였다. 일반 슬롯의 세라믹 브라켓인 Inspire, Signature III와 Cristaline V, 스테인레스 스틸 (SS) 슬롯을 가진 세라믹 브라켓인 Clarity, 골드 슬롯을 가진 Luxi II, polyoxymethylene 계열의 플라스틱 브라켓인 Brillant, SS 슬롯을 가진 컴파짓 브라켓인 Spirit MB, 금속 브라켓인 Integra를 사용하여 018"원형의 교정 탄선에 $0^{\circ}$, $4^{\circ}$, $8^{\circ}$의 tip angulation을 부여하고 elastic module로 결찰한 뒤 인공 타액 상태에서 활주이동 할 때의 운동 마찰력을 측정하였다. 연구 결과 슬롯에 silica 처리된 세라믹 브라켓 (CR)이 유의하게 낮은 마찰력을 보였고 (p < 0.05), 단결정 세라믹 브라켓이 (IN) 유의하게 큰 마찰력을 보였다 (p < 0.05). 플라스틱 브라켓인 polyoxymethylene 계열의 BR이 낮은 마찰력 양상을 보였고 이는 금속 브라켓과 유사하였다. 모든 브라켓에서 브라켓-탄선 각도가 증가함에 따라 유의하게 마찰력이 증가하였으나 주사전자현미경상에서 탄선이나 브라켓에 손상은 발견되지 않았다. 마찰력의 양상이 브라켓의 재질로 추측할 수 있는 것과는 다르게 나타난 결과로 보건대 심미 브라켓이 스테인레스 스틸 브라켓에 비해 마찰력 면에서는 오히려 우수하거나 큰 차이가 없으므로 임상적으로는 마찰력은 크게 고려하지 않아도 되겠다.

교정용 와이어의 비틀림 모멘트 (Torsional moment of orthodontic wires)

  • 최광철;김경호;박영철;강창수
    • 대한치과교정학회지
    • /
    • 제30권4호
    • /
    • pp.467-473
    • /
    • 2000
  • 각형 호선이 edgewise 브라켓에 삽입되면 first, second order는 bending에 의해, third order는 torsion(비틀림)에 의해 3차원적인 force system이 발생한다. Bending에 관하여는 분석적 그리고 실험적인 많은 연구가 보고 되어 있는 반면 비틀림에 관해서는 상대적으로 많은 연구가 이루어 지지 않았다. 본 연구의 목적은 각형 와이어의 재료와 단면의 형태가 와이어의 비틀림 모멘트에 어떻게 영향을 주는지를 이론적, 실험적으로 밝혀서 임상적으로 적절한 모멘트를 가할 때 호선의 재료와 굵기를 합리적으로 선택할 수 있도록 하는데 있다. 실험재료로는 third order조절을 위해 가장 많이 사용하는 호선을 사용하였다. 크기별로 0.016x0.022, 0.017x0.025, 0.019x0.025인치 그리고 재료로는 stainless steel (Ormco), TMA(Ormco), NiTi(Ormco), 그리고 braided stainless steel(DentaFlex, Dentauum) 네 가지를 사용하여 총 12개의 조합을 사용하였다. Torsion formula를 이용하여 비틀림 강성 (torque/twist rate)을 계산하였고 torque gauge를 이용하여 비틀림 강성, 항복 비틀림 모멘트 (yield torsional moment), 그리고 최대 비틀림 모멘트 (ultimate torsional moment)를 측정하였다. Torsion formula에 의하면 비틀림 강성 (T/$\theta$)은 재료적인 특성(G)과 호선의 단면의 특성(J)에 비례하고 호선의 길이(L)에 반비례한다. 대부분의 실험치는 이론적인 값과 비슷하게 나타났다.

  • PDF