• Title/Summary/Keyword: 교정치료 후

Search Result 702, Processing Time 0.02 seconds

Changes of Polyamine Metabolism and Delayed Neuronal Degeneration of Hippocampus after Transient Cerebral Ischemia in Mongolian Gerbils (뇌허혈 손상에 있어서 Polyamine 대사의 변동이 해마신경세포의 지연성괴사에 미치는 효과에 관한 연구)

  • Shin, Kyung-Ho;Shin, Hwa-Jung;Lee, Young-Jae;Kim, Hyung-Gun;Choi, Sang-Hyun;Chun, Yeon-Sook;Chun, Boe-Gwun
    • The Korean Journal of Pharmacology
    • /
    • v.32 no.3
    • /
    • pp.323-334
    • /
    • 1996
  • Male Mongolian gerbils $(60{\sim}80g)$ were given DL-difluoromethylornithine (DFMO; 250mg/kg, ip) and methylglyoxal bis(guanylhydrazone) (MGBG; 50 mg/k, ip), respectively, 1 h prior to transient (7 min) occlusion of bilateral common carotid arteries (OBC7) and a daily dose of one of them for 6 days after recirculation, and the polyamine contents, activities of ornithine and S-adenosylmethionine decarboxylases (ODC and SAM-DC), and light microscopic findings of the hippocampus were evaluated. The hippocampal putrescine (PT) levels of the control gerbils treated with saline (STGr), markedly increased after OBC7, showing a peak level at 24 h after recirculation. The peak PT level was reduced in DFMO treated gerbils (DTCr) and in MGBG treated gerbils (MTGr). And 7 days after recirculation, the PT level of DTGr was decreased to about 75% of the PT level in the sham operated group (nonTGr) and to about 55% of the STGr level, respectively. The hippocampal spermidine (SD) level of STGr tended to decline, showing the lowest value at 8 h after recirculation. But the spermidine (SD) level of DTGr was somewhat higher at 8 h after OBC7 than those of STGr and MTGr The hippocampal spermine (SM) levels of all the experimental groups were little changed for 7 days after OBC. OBC7 markedly increased the hippocampal ODC activity. reaching a maximum (about 3 times higher than preischemic level) at 8 h and rapidly recovered to the control value by 24 h in STGr gerbils, and the OBC7-induced increase of ODC activity was significantly attenuated by DFMO or MGBG treatment. Whereas OBC7 induced a rapid decrease of the hippocampal SAMDC activity follwed by gradual recovery to the preischemic level, and the decrease of the SAMDC activity was slightly attenuated by DFMO or MGBG treatment. 7 Days after OBC7 the histological finding of the hippocampal complex stained with cresyl violet showed an extensive delayed neuronal damage in the CA1 region and to a lesser extent, in the dentate gyrus, sparing the CA3 region. And the neuronal death was aggevated by DFMO but significantly attenuated by MGBG. The immunochemical reactivity of hippocampus to anti-GFAP antibody was significantly increased in the CA1 region and to a lesser extent, in the dentate gyrus 7 days after OBC7, but was little changed in the CA3. And the increase of the anti-GFAP immunoreactivity was moderately enhanced by DFMO and significantly suppressed by MGBG. These results suggest that the polyamine metabolism may play a modulatory role in the ischemic brain damage.

  • PDF

Variation on Estimated Values of Radioactivity Concentration According to the Change of the Acquisition Time of SPECT/CT (SPECT/CT의 획득시간 증감에 따른 방사능농도 추정치의 변화)

  • Kim, Ji-Hyeon;Lee, Jooyoung;Son, Hyeon-Soo;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.2
    • /
    • pp.15-24
    • /
    • 2021
  • Purpose SPECT/CT was noted for its excellent correction method and qualitative functions based on fusion images in the early stages of dissemination, and interest in and utilization of quantitative functions has been increasing with the recent introduction of companion diagnostic therapy(Theranostics). Unlike PET/CT, various conditions like the type of collimator and detector rotation are a challenging factor for image acquisition and reconstruction methods at absolute quantification of SPECT/CT. Therefore, in this study, We want to find out the effect on the radioactivity concentration estimate by the increase or decrease of the total acquisition time according to the number of projections and the acquisition time per projection among SPECT/CT imaging conditions. Materials and Methods After filling the 9,293 ml cylindrical phantom with sterile water and diluting 99mTc 91.76 MBq, the standard image was taken with a total acquisition time of 600 sec (10 sec/frame × 120 frames, matrix size 128 × 128) and also volume sensitivity and the calibration factor was verified. Based on the standard image, the comparative images were obtained by increasing or decreasing the total acquisition time. namely 60 (-90%), 150 (-75%), 300 (-50%), 450 (-25%), 900 (+50%), and 1200 (+100%) sec. For each image detail, the acquisition time(sec/frame) per projection was set to 1.0, 2.5, 5.0, 7.5, 15.0 and 20.0 sec (fixed number of projections: 120 frame) and the number of projection images was set to 12, 30, 60, 90, 180 and 240 frames(fixed time per projection:10 sec). Based on the coefficients measured through the volume of interest in each acquired image, the percentage of variation about the contrast to noise ratio (CNR) was determined as a qualitative assessment, and the quantitative assessment was conducted through the percentage of variation of the radioactivity concentration estimate. At this time, the relationship between the radioactivity concentration estimate (cps/ml) and the actual radioactivity concentration (Bq/ml) was compared and analyzed using the recovery coefficient (RC_Recovery Coefficients) as an indicator. Results The results [CNR, radioactivity Concentration, RC] by the change in the number of projections for each increase or decrease rate (-90%, -75%, -50%, -25%, +50%, +100%) of total acquisition time are as follows. [-89.5%, +3.90%, 1.04] at -90%, [-77.9%, +2.71%, 1.03] at -75%, [-55.6%, +1.85%, 1.02] at -50%, [-33.6%, +1.37%, 1.01] at -25%, [-33.7%, +0.71%, 1.01] at +50%, [+93.2%, +0.32%, 1.00] at +100%. and also The results [CNR, radioactivity Concentration, RC] by the acquisition time change for each increase or decrease rate (-90%, -75%, -50%, -25%, +50%, +100%) of total acquisition time are as follows. [-89.3%, -3.55%, 0.96] at - 90%, [-73.4%, -0.17%, 1.00] at -75%, [-49.6%, -0.34%, 1.00] at -50%, [-24.9%, 0.03%, 1.00] at -25%, [+49.3%, -0.04%, 1.00] at +50%, [+99.0%, +0.11%, 1.00] at +100%. Conclusion In SPECT/CT, the total coefficient obtained according to the increase or decrease of the total acquisition time and the resulting image quality (CNR) showed a pattern that changed proportionally. On the other hand, quantitative evaluations through absolute quantification showed a change of less than 5% (-3.55 to +3.90%) under all experimental conditions, maintaining quantitative accuracy (RC 0.96 to 1.04). Considering the reduction of the total acquisition time rather than the increasing of the image acquiring time, The reduction in total acquisition time is applicable to quantitative analysis without significant loss and is judged to be clinically effective. This study shows that when increasing or decreasing of total acquisition time, changes in acquisition time per projection have fewer fluctuations that occur in qualitative and quantitative condition changes than the change in the number of projections under the same scanning time conditions.